{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,8]],"date-time":"2025-11-08T22:36:46Z","timestamp":1762641406327,"version":"build-2065373602"},"reference-count":34,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2011,3,16]],"date-time":"2011-03-16T00:00:00Z","timestamp":1300233600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This work describes the use of an array of potentiometric sensors and an artificial neural network response model to determine perchlorate and sulfide ions in polluted waters, by what is known as an electronic tongue. Sensors used have been all-solid-state PVC membrane selective electrodes, where their ionophores were different metal-phtalocyanine complexes with specific and anion generic responses. The study case illustrates the potential use of electronic tongues in the quantification of mixtures when interfering effects need to be counterbalanced: relative errors in determination of individual ions can be decreased typically from 25% to less than 5%, if compared to the use of a single proposed ion-selective electrode.<\/jats:p>","DOI":"10.3390\/s110303214","type":"journal-article","created":{"date-parts":[[2011,3,16]],"date-time":"2011-03-16T07:24:32Z","timestamp":1300260272000},"page":"3214-3226","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Potentiometric Electronic Tongue to Resolve Mixtures of Sulfide and Perchlorate Anions"],"prefix":"10.3390","volume":"11","author":[{"given":"Deivy","family":"Wilson","sequence":"first","affiliation":[{"name":"Sensors and Biosensors Group, Department of Chemistry, Universitat Aut\u00f2noma de Barcelona, 08193 Bellaterra, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammed N.","family":"Abbas","sequence":"additional","affiliation":[{"name":"Analytical Laboratory, National Research Centre, Dokki, Cairo, Egypt"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abdel Latief A.","family":"Radwan","sequence":"additional","affiliation":[{"name":"Analytical Laboratory, National Research Centre, Dokki, Cairo, Egypt"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1032-8611","authenticated-orcid":false,"given":"Manel del","family":"Valle","sequence":"additional","affiliation":[{"name":"Sensors and Biosensors Group, Department of Chemistry, Universitat Aut\u00f2noma de Barcelona, 08193 Bellaterra, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2011,3,16]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Patnaik, P (1999). A Comprehensive Guide to the Hazardous Properties of Chemical Substances, Wiley. [2nd ed].","DOI":"10.1021\/jm990484d"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1016\/j.snb.2006.02.036","article-title":"Perchlorate selective membrane electrodes based on synthesized platinum(II) complexes for low-level concentration measurements","volume":"120","author":"Soleymanpour","year":"2007","journal-title":"Sens. Actuat. B"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1016\/S0039-9140(00)00421-5","article-title":"Analytical strategies for the detection of sulfide: A review","volume":"52","author":"Lawrence","year":"2000","journal-title":"Talanta"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1016\/j.snb.2005.03.003","article-title":"Perchlorate-selective polymeric membrane electrode based on a cobaloxime as a suitable carrier","volume":"113","author":"Zanjanchi","year":"2006","journal-title":"Sens. Actuat. B"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.aca.2004.03.101","article-title":"Electrochemical determination of hydrogen sulfide at carbon nanotube modified electrodes","volume":"517","author":"Lawrence","year":"2004","journal-title":"Anal. Chim. Acta"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.aca.2003.10.030","article-title":"Improving the lower detection limit of potentiometric sensors by covalently binding the ionophore to a polymer backbone","volume":"503","author":"Vigassy","year":"2004","journal-title":"Anal. Chim. Acta"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1002\/(SICI)1521-4109(200002)12:3<178::AID-ELAN178>3.0.CO;2-Z","article-title":"One-step synthesis of K+-selective methacrylic-acrylic copolymers containing grafted ionophore and requiring no plasticizer","volume":"12","author":"Heng","year":"2000","journal-title":"Electroanalysis"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1965","DOI":"10.1351\/pac200577111965","article-title":"Nonspecific sensor arrays (\u201celectronic tongue\u201d) for chemical analysis of liquids","volume":"77","author":"Vlasov","year":"2005","journal-title":"Pure Appl. Chem"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1002\/elan.201000013","article-title":"Electronic tongues employing electrochemical sensors","volume":"22","year":"2010","journal-title":"Electroanalysis"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1016\/j.snb.2005.09.024","article-title":"A flow injection voltammetric electronic tongue applied to paper mill industrial waters","volume":"115","author":"Cespedes","year":"2006","journal-title":"Sens. Actuat. B"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.aca.2008.12.034","article-title":"Study of the influence of micro-oxygenation and oak chip maceration on wine composition using an electronic tongue and chemical analysis","volume":"642","author":"Rudnitskaya","year":"2009","journal-title":"Anal. Chim. Acta"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1128","DOI":"10.3390\/s6091128","article-title":"Electronic tongue for qualitative analysis of aqueous solutions of salts using thick-film technology and metal electrodes","volume":"6","author":"Gil","year":"2006","journal-title":"Sensors"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1016\/S0925-4005(97)00169-X","article-title":"Multicomponent analysis on polluted waters by means of an electronic tongue","volume":"44","author":"Macagnano","year":"1997","journal-title":"Sens. Actuat. B"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1016\/j.envsoft.2009.12.003","article-title":"A review of the use of the potentiometric electronic tongue in the monitoring of environmental systems","volume":"25","author":"Mimendia","year":"2010","journal-title":"Environ. Modell. Softw"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"3665","DOI":"10.3390\/s8063665","article-title":"Disposable e-tongue for the assessment of water quality in fish tanks","volume":"8","author":"Chang","year":"2008","journal-title":"Sensors"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1039\/b705107g","article-title":"Sensor arrays for liquid sensing\u2014Electronic tongue systems","volume":"132","author":"Ciosek","year":"2007","journal-title":"Analyst"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2481","DOI":"10.1039\/c0an00292e","article-title":"Recent advances in electronic tongues","volume":"135","author":"Riul","year":"2010","journal-title":"Analyst"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1007\/s00216-006-0530-2","article-title":"A sequential injection electronic tongue employing the transient response from potentiometric sensors for anion multidetermination","volume":"385","author":"Cortina","year":"2006","journal-title":"Anal. Bioanal. Chem"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.snb.2007.07.015","article-title":"Potentiometric electronic tongue based on integrated array of microelectrodes","volume":"127","author":"Ciosek","year":"2007","journal-title":"Sens. Actuat. B"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"923","DOI":"10.1351\/pac200274060923","article-title":"Potentiometric selective coeffcients of ion selective electrodes. Part II. Inorganic anions","volume":"74","author":"Umezawa","year":"2002","journal-title":"Pure Appl.Chem"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1007\/s00216-006-0512-4","article-title":"A novel thiocyanate-selective electrode based on a zinc\u2013phthalocyanine complex","volume":"385","author":"Xu","year":"2006","journal-title":"Anal. Bioanal. Chem"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1002\/elan.200704059","article-title":"Novel polymeric membrane sensors based on Mn(III) porphyrin and Co(II) phthalocyanine ionophores for batch and flow injection determination of azide","volume":"20","author":"Hassan","year":"2008","journal-title":"Electroanalysis"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"995","DOI":"10.2116\/analsci.19.995","article-title":"Novel membrane potentiometric sulfate ion sensor based on zinc-phtalocyanine for the quick determination of trace amounts of sulfate","volume":"19","author":"Ganjali","year":"2003","journal-title":"Anal. Sci"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1016\/0925-4005(93)85046-D","article-title":"Construction and development of ion-selective electrodes responsive to anionic surfactants","volume":"15","author":"Alonso","year":"1993","journal-title":"Sens. Actuat. B"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1023\/B:JOSL.0000035359.00943.14","article-title":"Determination of hydrogen single ion activity coefficients in aqueous HCl solutions at 25 \u00b0C","volume":"33","author":"Schneider","year":"2004","journal-title":"J. Soln. Chem"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1563","DOI":"10.1134\/S1070427210090119","article-title":"Comparison of the analytical potential of individual sensors and a multisensor system of the electronic tongue type for the example of determination of the perchlorate ion","volume":"83","author":"Polshin","year":"2010","journal-title":"Russian J. Appl. Chem"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1007\/s00604-007-0894-9","article-title":"Electronic tongue for the determination of alkaline ions using a screen-printed potentiometric sensor array","volume":"163","author":"Gutierrez","year":"2007","journal-title":"Microchim. Acta"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1533","DOI":"10.1002\/1521-4109(200211)14:22<1533::AID-ELAN1533>3.0.CO;2-T","article-title":"Multivariate data analysis in electroanalytical chemistry","volume":"14","author":"Richards","year":"2002","journal-title":"Electroanalysis"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"2893","DOI":"10.1081\/AL-120026410","article-title":"Determination of ammonium ion employing an electronic tongue based on potentiometric sensors","volume":"36","author":"Gallardo","year":"2003","journal-title":"Anal. Lett"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.jpba.2007.09.013","article-title":"Automated electronic tongue based on potentiometric sensors for the determination of a trinary anionic surfactant mixture","volume":"46","author":"Cortina","year":"2008","journal-title":"J. Pharm. Biomed. Anal"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"157R","DOI":"10.1039\/a805562i","article-title":"Neural networks in multivariate calibration","volume":"123","author":"Despagne","year":"1998","journal-title":"Analyst"},{"key":"ref_32","unstructured":"Alegret, S, and Merko\u00e7i, A (2007). Electrochemical Sensor Analysis, Elsevier."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1002\/elan.200303097","article-title":"Use of an electronic tongue based on all-solid-state potentiometric sensors for the quantitation of alkaline ions","volume":"17","author":"Gallardo","year":"2005","journal-title":"Electroanalysis"},{"key":"ref_34","unstructured":"Demuth, H, and Beale, M (1992). Neural Network Toolbox, for Use with MATLAB, Mathworks Inc."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/3\/3214\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:55:33Z","timestamp":1760219733000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/3\/3214"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,3,16]]},"references-count":34,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2011,3]]}},"alternative-id":["s110303214"],"URL":"https:\/\/doi.org\/10.3390\/s110303214","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2011,3,16]]}}}