{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,23]],"date-time":"2026-11-23T09:35:15Z","timestamp":1795426515353,"version":"4.10.3"},"reference-count":34,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2011,3,28]],"date-time":"2011-03-28T00:00:00Z","timestamp":1301270400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>An approach to an inhibition bioelectronic tongue is presented. The work is focused on development of an automated flow system to carry out experimental assays, a custom potentiostat to measure the response from an enzymatic biosensor, and an inhibition protocol which allows on-line detections. A Multi-commuted Flow Analysis system (MCFA) was selected and developed to carry out assays with an improved inhibition method to detect the insecticides chlorpyrifos oxon (CPO), chlorfenvinfos (CFV) and azinphos methyl-oxon (AZMO). The system manifold comprised a peristaltic pump, a set of seven electronic valves controlled by a personal computer electronic interface and software based on LabView\u00ae to control the sample dilutions into the cell. The inhibition method consists in the injection of the insecticide when the enzyme activity has reached the plateau of the current; with this method the incubation time is avoided. A potentiostat was developed to measure the response from the enzymatic biosensor. Low limits of detection of 10 nM for CPO, CFV, and AZMO were achieved.<\/jats:p>","DOI":"10.3390\/s110403791","type":"journal-article","created":{"date-parts":[[2011,3,28]],"date-time":"2011-03-28T10:46:42Z","timestamp":1301309202000},"page":"3791-3802","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["An Approach to an Inhibition Electronic Tongue to Detect On-Line Organophosphorus Insecticides Using a Computer Controlled Multi-Commuted Flow System"],"prefix":"10.3390","volume":"11","author":[{"given":"Gustavo A.","family":"Alonso","sequence":"first","affiliation":[{"name":"Centro de Investigaci\u00f3n y de Estudios Avanzados del Intituto Politecnico Nacional, Av. Instituto Polit\u00e9cnico Nacional 2508, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rocio B.","family":"Dominguez","sequence":"additional","affiliation":[{"name":"Centro de Investigaci\u00f3n y de Estudios Avanzados del Intituto Politecnico Nacional, Av. Instituto Polit\u00e9cnico Nacional 2508, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Louis","family":"Marty","sequence":"additional","affiliation":[{"name":"Universit\u00e9 de Perpignan Via Domitia, IMAGES EA4218, Centre de Phytopharmacie, 52 Avenue Paul Alduy, 66860 Perpignan Cedex, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roberto","family":"Mu\u00f1oz","sequence":"additional","affiliation":[{"name":"Centro de Investigaci\u00f3n y de Estudios Avanzados del Intituto Politecnico Nacional, Av. Instituto Polit\u00e9cnico Nacional 2508, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2011,3,28]]},"reference":[{"key":"ref_1","first-page":"145","article-title":"Flow injection analysis. Part I. A new concept of fast continuous flow analysis","volume":"78","author":"Ruzicka","year":"1975","journal-title":"Anal. Chim. Acta"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1016\/j.trac.2008.03.004","article-title":"Retro-review of flow-injection analysis","volume":"27","author":"Ruzicka","year":"2008","journal-title":"TrAC Trends Anal. Chem"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1016\/S0003-2670(00)83937-9","article-title":"Sequential injection: A new concept for chemical sensors, process analysis and laboratory assays","volume":"237","author":"Ruzicka","year":"1990","journal-title":"Anal. Chim. Acta"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1039\/b106791p","article-title":"Sequential injection analysis","volume":"127","author":"Lenehan","year":"2002","journal-title":"Analyst"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.trac.2006.07.010","article-title":"How flow-injection analysis (FIA) over the past 25 years has changed our way of performing chemical analyses","volume":"26","author":"Hansen","year":"2007","journal-title":"TrAC Trends Anal. Chem"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1161","DOI":"10.3390\/s6101161","article-title":"Trends in flow-based biosensing systems for pesticide assessment","volume":"6","author":"Andreescu","year":"2006","journal-title":"Sensors"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1002\/1521-4109(200101)13:1<79::AID-ELAN79>3.0.CO;2-4","article-title":"On-line analysis of mercury by Sequential Injection Stripping Analysis (SISA) using a chemically modified electrode","volume":"13","author":"Turyan","year":"2001","journal-title":"Electroanalysis"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"53","DOI":"10.2174\/157341210790780195","article-title":"Multicommutation in flow systems: A useful tool for pharmaceutical and clinical analysis","volume":"6","author":"Barrales","year":"2010","journal-title":"Curr. Pharm. Anal"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1002\/elan.201000013","article-title":"Electronic tongues employing electrochemical sensors","volume":"22","year":"2010","journal-title":"Electroanalysis"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1109\/19.137366","article-title":"A potentiostat based on a voltage-controlled current source for use with amperometric gas sensors","volume":"41","author":"Fidler","year":"1992","journal-title":"IEEE Trans. Instrum. Meas"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1109\/JSSC.1987.1052753","article-title":"A CMOS potentiostat for amperometric chemical sensors","volume":"22","author":"Turner","year":"1987","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_12","unstructured":"Kakerow, R, Kappert, H, Spiegel, E, and Manoli, Y (1995, January 25\u201329). Low-power single-chip CMOS potentiostat. Stockholm, Sweden."},{"key":"ref_13","unstructured":"Bandyopadhyay, A, Mulliken, G, Cauwenberghs, G, and Thakor, N (2002, January 26\u201329). VLSI potentiostat array for distributed electrochemical neural recording. Phoenix-Scottsdale, AZ, USA."},{"key":"ref_14","unstructured":"Frey, A, Jenkner, M, Schienle, M, Paulus, C, Holzapfl, B, Schindler-Bauer, P, Hofmann, F, Kuhlmeier, D, Krause, J, Albers, J, Gumbrecht, W, Schmitt-Landsiedel, D, and Thewes, R (2003, January 25\u201328). Design of an integrated potentiostat circuit for CMOS bio sensor chips. Bangkok, Thailand."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1016\/j.snb.2003.09.002","article-title":"A micropower amperometric potentiostat","volume":"97","author":"Steinberg","year":"2004","journal-title":"Sens. Actuat. B"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1694","DOI":"10.1016\/j.bios.2006.07.036","article-title":"A portable potentiostat for the bilirubin-specific sensor prepared from molecular imprinting","volume":"22","author":"Huang","year":"2007","journal-title":"Biosens. Bioelectron"},{"key":"ref_17","unstructured":"(2001). Decision No. 2455\/2001\/EC of the European Parliament and of the Council of 20 November 2001 establishing the list of priority substances in the field of water policy and amending Directive 2000\/60\/EC (Text with EEA relevance). Official J. Europ. Communities, 15, 1\u20135."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/S0003-2670(02)00518-4","article-title":"Immobilization of acetylcholinesterase on screen-printed electrodes: Comparative study between three immobilization methods and applications to the detection of organophosphorus insecticides","volume":"464","author":"Andreescu","year":"2002","journal-title":"Anal. Chim. Acta"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.aca.2004.03.100","article-title":"Enzyme immobilization procedures on screen-printed electrodes used for the detection of anticholinesterase pesticides: Comparative study","volume":"523","author":"Jeanty","year":"2004","journal-title":"Anal. Chim. Acta"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.bioeng.2006.01.001","article-title":"Twenty years research in cholinesterase biosensors: From basic research to practical applications","volume":"23","author":"Andreescu","year":"2006","journal-title":"Biomol. Eng"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1002\/elan.200704087","article-title":"Electronic tongue using an enzyme inhibition biosensor array for the resolution of pesticide mixtures","volume":"20","author":"Cortina","year":"2008","journal-title":"Electroanalysis"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1103","DOI":"10.1016\/j.bios.2008.06.022","article-title":"Automated resolution of dichlorvos and methylparaoxon pesticide mixtures employing a Flow Injection system with an inhibition electronic tongue","volume":"24","author":"Fournier","year":"2009","journal-title":"Biosens. Bioelectron"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/0006-2952(61)90145-9","article-title":"A new and rapid colorimetric determination of acetylcholinesterase activity","volume":"7","author":"Ellman","year":"1961","journal-title":"Biochem. Pharmacol"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1016\/j.talanta.2007.07.004","article-title":"Sensitive amperometric biosensor for dichlorovos quantification: Application to detection of residues on apple skin","volume":"74","author":"Fournier","year":"2008","journal-title":"Talanta"},{"key":"ref_25","unstructured":"Z\u00fa\u00f1iga, M, Monsalve, L, and Valdivieso, M (2007). Bioingenieria Tomo VI, Universidad de Antioquia."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1028","DOI":"10.1021\/bi00534a031","article-title":"Determination of the rate constant of enzyme modification by measuring the substrate reaction in the presence of the modifier","volume":"21","author":"Tian","year":"1982","journal-title":"Biochemistry"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1042\/bj2570419","article-title":"Analysis of kinetic data for irreversible enzyme inhibition","volume":"257","author":"Gray","year":"1989","journal-title":"Biochem. J"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1007\/s00604-010-0317-1","article-title":"Biosensors based on cholinesterase inhibition for insecticides, nerve agents and aflatoxin B1 detection (review)","volume":"170","author":"Arduini","year":"2010","journal-title":"Microchim. Acta"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"(1978). IUPAC Nomenclature, symbols, units and their usage in spectrochemical analysis-II. Data interpretation Analytical chemistry division. Spectrochim. Acta Part B: At. Spectrosc, 33, 241\u2013245.","DOI":"10.1016\/0584-8547(78)80044-5"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1093\/clinchem\/40.7.1233","article-title":"Limit of detection (LQD)\/limit of quantitation (LOQ): Comparison of the empirical and the statistical methods exemplified with GC-MS assays of abused drugs","volume":"40","author":"Armbruster","year":"1994","journal-title":"Clin. Chem"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1007\/s00216-002-1336-5","article-title":"Flow-injection amperometric determination of pesticides on the basis of their inhibition of immobilized acetylcholinesterases of different origin","volume":"373","author":"Jeanty","year":"2002","journal-title":"Anal. Bioanal.Chem"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1914","DOI":"10.1016\/j.bios.2004.08.048","article-title":"Sonochemically fabricated acetylcholinesterase micro-electrode arrays within a flow injection analyser for the determination of organophosphate pesticides","volume":"20","author":"Law","year":"2005","journal-title":"Biosens. Bioelectron"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1016\/j.bios.2007.06.022","article-title":"Highly sensitive detection of organophosphorus insecticides using magnetic microbeads and genetically engineered acetylcholinesterase","volume":"23","author":"Istamboulie","year":"2007","journal-title":"Biosens. Bioelectron"},{"key":"ref_34","unstructured":"(2007). IFEN Pesticides in Water, Fifth Annual Report No. 9. 9, 1\u201336."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/4\/3791\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:55:40Z","timestamp":1760219740000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/4\/3791"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,3,28]]},"references-count":34,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2011,4]]}},"alternative-id":["s110403791"],"URL":"https:\/\/doi.org\/10.3390\/s110403791","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,3,28]]}}}