{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:36:35Z","timestamp":1760243795994,"version":"build-2065373602"},"reference-count":23,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2011,6,3]],"date-time":"2011-06-03T00:00:00Z","timestamp":1307059200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This study provides a general framework to analyze the effects on correlation radiometers of a generic quantization scheme and sampling process. It reviews, unifies and expands several previous works that focused on these effects separately. In addition, it provides a general theoretical background that allows analyzing any digitization scheme including any number of quantization levels, irregular quantization steps, gain compression, clipping, jitter and skew effects of the sampling period.<\/jats:p>","DOI":"10.3390\/s110606066","type":"journal-article","created":{"date-parts":[[2011,6,3]],"date-time":"2011-06-03T14:58:56Z","timestamp":1307113136000},"page":"6066-6087","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["A General Analysis of the Impact of Digitization in Microwave Correlation Radiometers"],"prefix":"10.3390","volume":"11","author":[{"given":"Xavier","family":"Bosch-Lluis","sequence":"first","affiliation":[{"name":"Remote Sensing Lab, Signal Theory and Communications Department, Building D3, Universitat Polit\u00e8cnica de Catalunya and IEEC CRAE\/UPC, E-08034 Barcelona, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Isaac","family":"Ramos-Perez","sequence":"additional","affiliation":[{"name":"Remote Sensing Lab, Signal Theory and Communications Department, Building D3, Universitat Polit\u00e8cnica de Catalunya and IEEC CRAE\/UPC, E-08034 Barcelona, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9514-4992","authenticated-orcid":false,"given":"Adriano","family":"Camps","sequence":"additional","affiliation":[{"name":"Remote Sensing Lab, Signal Theory and Communications Department, Building D3, Universitat Polit\u00e8cnica de Catalunya and IEEC CRAE\/UPC, E-08034 Barcelona, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nereida","family":"Rodriguez-Alvarez","sequence":"additional","affiliation":[{"name":"Remote Sensing Lab, Signal Theory and Communications Department, Building D3, Universitat Polit\u00e8cnica de Catalunya and IEEC CRAE\/UPC, E-08034 Barcelona, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Enric","family":"Valencia","sequence":"additional","affiliation":[{"name":"Remote Sensing Lab, Signal Theory and Communications Department, Building D3, Universitat Polit\u00e8cnica de Catalunya and IEEC CRAE\/UPC, E-08034 Barcelona, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0031-0802","authenticated-orcid":false,"given":"Hyuk","family":"Park","sequence":"additional","affiliation":[{"name":"Remote Sensing Lab, Signal Theory and Communications Department, Building D3, Universitat Polit\u00e8cnica de Catalunya and IEEC CRAE\/UPC, E-08034 Barcelona, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2011,6,3]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1063\/1.1770483","article-title":"The measurement of thermal radiation at microwave frequencies","volume":"17","author":"Dicke","year":"1946","journal-title":"Rev. Sci. Instr"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2040","DOI":"10.1109\/TGRS.2007.898092","article-title":"Aquarius: An instrument to monitor sea surface salinity from space","volume":"45","author":"Lagerloef","year":"2007","journal-title":"IEEE Trans. Geosci. Remot. Sens"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1029\/RS013i004p00677","article-title":"The accuracy of water vapor and cloud liquid determination by dual frequency ground-based microwave radiometry","volume":"32","author":"Westwater","year":"1978","journal-title":"Radio Sci"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1109\/TGRS.2008.916264","article-title":"SMOS: The mission and the system","volume":"46","author":"Barre","year":"2008","journal-title":"IEEE Trans. Geosci. Remot. Sens"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2050","DOI":"10.1109\/TMTT.2005.848815","article-title":"Very low-noise differential radiometer at 30 GHz for the PLANCK LFI","volume":"53","author":"Aja","year":"2005","journal-title":"IEEE Trans. Microw. Theor. Tech"},{"key":"ref_6","first-page":"1099","article-title":"Digital radiometer","volume":"49","author":"Weinreb","year":"1961","journal-title":"Proc. IEEE"},{"key":"ref_7","first-page":"521","article-title":"Correlators with two-bit quantization","volume":"23","author":"Cooper","year":"1970","journal-title":"Aust. J. Phys"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1109\/PROC.1966.4567","article-title":"The spectrum of clipped noise","volume":"54","author":"Middleton","year":"1966","journal-title":"Proc. IEEE"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1109\/TIT.1958.1057444","article-title":"A useful theorem for nonlinear devices having Gaussian inputs","volume":"4","author":"Price","year":"1958","journal-title":"IRE Trans. Inform. Theory"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1029\/RS008i008p00775","article-title":"Digital-correlation techniques in radio science","volume":"8","author":"Hagen","year":"1973","journal-title":"Radio Sci"},{"key":"ref_11","first-page":"2830","article-title":"Advances in microwave digital radiometry","volume":"7","author":"Piepmeier","year":"2000","journal-title":"Proc. IEEE Int. Geosci. Remot. Sens. Symp"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2172","DOI":"10.1109\/36.789614","article-title":"Sensitivity of a 1.4 GHz direct sampling digital radiometer","volume":"37","author":"Fischman","year":"1999","journal-title":"IEEE Trans. Geosci. Remot. Sens"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1222","DOI":"10.1109\/36.469486","article-title":"Digital correlators for synthetic aperture interferometric radiometry","volume":"33","author":"Ruf","year":"1995","journal-title":"IEEE Trans. Geosci. Remot. Sens"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1109\/TGRS.2002.1000326","article-title":"How digital correlation affects the fringe washing function in L-band aperture synthesis radiometry","volume":"40","author":"Fischman","year":"2002","journal-title":"IEEE Trans. Geosci. Remot. Sens"},{"key":"ref_15","first-page":"2975","article-title":"L-band aperture synthesis radiometry: Hardware requirements and system performance","volume":"7","author":"Corbella","year":"2000","journal-title":"Proc. IEEE Int. Geosci. Remot. Sens. Symp"},{"key":"ref_16","unstructured":"Papoulis, A (1991). Probability, Random Variables, and Stochastic Processes, McGraw-Hill."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1049\/el:19990125","article-title":"Automatic calibration of channels frequency response in interferometric radiometers","volume":"35","author":"Camps","year":"1999","journal-title":"Electron. Lett"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1109\/TAP.1964.1138345","article-title":"Radio astronomy receivers","volume":"12","author":"Tiuri","year":"1964","journal-title":"IEEE Trans. Antenn. Propag"},{"key":"ref_19","unstructured":"Thompson, AR, Moran, JM, and Swenson, GW (2007). Interferometry and Synthesis in Radio Astronomy, Wiley-VCH. [2nd ed]."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"6131","DOI":"10.3390\/s90806131","article-title":"Calibration of correlation radiometers using pseudo-random noise signals","volume":"9","author":"Camps","year":"2009","journal-title":"Sensors"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"812","DOI":"10.1049\/el:19970526","article-title":"Threshold and timing errors of 1 bid2 level digital correlators in earth observation synthetic aperture radiometry","volume":"33","author":"Camps","year":"1997","journal-title":"Electron. Lett"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1109\/81.847872","article-title":"Phase noise in oscillators: A unifying theory and numerical methods for characterization","volume":"47","author":"Demir","year":"2000","journal-title":"IEEE Trans. Circ. Syst. Fund. Theor. Appl"},{"key":"ref_23","unstructured":"Kobayashi, H, Morimura, M, Kobayashi, K, and Onaya, Y (1999, January 28\u201330). Aperture jitter effects in wideband ADC systems. Iwate, Japan."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/6\/6066\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:56:18Z","timestamp":1760219778000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/6\/6066"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,6,3]]},"references-count":23,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2011,6]]}},"alternative-id":["s110606066"],"URL":"https:\/\/doi.org\/10.3390\/s110606066","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2011,6,3]]}}}