{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,15]],"date-time":"2025-10-15T17:25:13Z","timestamp":1760549113578,"version":"build-2065373602"},"reference-count":16,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2011,7,4]],"date-time":"2011-07-04T00:00:00Z","timestamp":1309737600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This paper presents a micro-fluid gathering tool for a versatile capsular endoscope that employs a solid chemical propellant, azobisisobutyronitrile (AIBN). The proposed tool consists of a micro-heater, an AIBN matrix, a Venturi tube, a reservoir, an inlet, and an outlet. The micro-heater heats the AIBN matrix to be decomposed into by-products and nitrogen gas. This nitrogen gas generates negative pressure passing through the Venturi tube. The generated negative pressure inhales a target fluid from around the inlet into the reservoir. All the parts are designed to be embedded inside a cylindrical shape with a diameter of 17 mm and a height of 2.3 mm in order to integrate it into a versatile developmental capsular endoscope without any scaledown. Two sets of the proposed tools are fabricated and tested: one is made of polydimethylsiloxane (PDMS) and the other is made of polymethylmethacrylate (PMMA). In performance comparisons, the PDMS gathering tool can withstand a stronger pulling force, and the PMMA gathering tool requires a less negative pressure for inhaling the same target fluid. Due to the instant and full activation of the thin AIBN matrix, both types of gathering tool show analogous performance in the sample gathering evaluation. The gathered volume is approximately 1.57 \u03bcL using approximately 25.4 \u03bcL of AIBN compound.<\/jats:p>","DOI":"10.3390\/s110706978","type":"journal-article","created":{"date-parts":[[2011,7,4]],"date-time":"2011-07-04T15:06:10Z","timestamp":1309791970000},"page":"6978-6990","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Fabrication of a Micro-Fluid Gathering Tool for the Gastrointestinal Juice Sampling Function of a Versatile Capsular Endoscope"],"prefix":"10.3390","volume":"11","author":[{"given":"Kyo-in","family":"Koo","sequence":"first","affiliation":[{"name":"Inter-University Semiconductor Research Center and Automation System Research Institute, School of Electrical Engineering and Computer Science, Seoul National University, 599 Gwanak-ro Gwanak-gu, 151-744, Seoul, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sangmin","family":"Lee","sequence":"additional","affiliation":[{"name":"Inter-University Semiconductor Research Center and Automation System Research Institute, School of Electrical Engineering and Computer Science, Seoul National University, 599 Gwanak-ro Gwanak-gu, 151-744, Seoul, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8040-5803","authenticated-orcid":false,"given":"Dong-il Dan","family":"Cho","sequence":"additional","affiliation":[{"name":"Inter-University Semiconductor Research Center and Automation System Research Institute, School of Electrical Engineering and Computer Science, Seoul National University, 599 Gwanak-ro Gwanak-gu, 151-744, Seoul, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2011,7,4]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1109\/MEMB.2002.1016851","article-title":"Golden accomplishments in biomedical engineering","volume":"21","author":"Nebeker","year":"2002","journal-title":"IEEE Eng. Med. Biol. Mag"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1067\/mge.2000.110204","article-title":"The development of the swallowable video capsule (M2A)","volume":"6","author":"Meron","year":"2000","journal-title":"Gastrointest. Endosc"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1002\/rcs.13","article-title":"The development and application of wireless capsule endoscopy","volume":"1","author":"Glukhovsky","year":"2004","journal-title":"Int. J. Med. Robot. Comput. Assist. Surg"},{"unstructured":"Olympus. Company Profile: Medical Systems Business. Available online: http:\/\/www.olympus.com (accessed on 29 June 2011).","key":"ref_4"},{"unstructured":"SmartPill Corp. The Measure of GI Health Homepage. Available online: http:\/\/www.smartpillcorp.com (accessed on 16 May 2011).","key":"ref_5"},{"unstructured":"Vector. Available online: http:\/\/www.vector-project.com (accessed on 14 March 2011).","key":"ref_6"},{"unstructured":"Development of a Capsule Endoscope. Available online: http:\/\/www.kist.re.kr (accessed on 29 June 2011).","key":"ref_7"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"R35","DOI":"10.1088\/0960-1317\/14\/6\/R01","article-title":"A review of micropumps","volume":"14","author":"Laser","year":"2004","journal-title":"J. Micromech. Microeng"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/j.cej.2004.01.017","article-title":"MEMS-based components of a miniature fuel cell\/fuel reformer system","volume":"101","author":"Tanaka","year":"2004","journal-title":"Chem. Eng. J"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1002\/1521-4087(200106)26:3<118::AID-PREP118>3.0.CO;2-0","article-title":"On the potimization of GAP-based ducted rocket fuels from gas generator exhaust characterization","volume":"26","author":"Ringuette","year":"2001","journal-title":"Propell. Explos. Pyrotech"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1039\/b306116g","article-title":"A functional on-chip pressure generator using solid chemical propellant for disposable lab-on-a-chip","volume":"3","author":"Hong","year":"2003","journal-title":"Lab Chip"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1002\/(SICI)1097-0126(200004)49:4<412::AID-PI395>3.0.CO;2-J","article-title":"Effect of stannous octoate on the thermal decomposition of 2,2\u2032-azobis(isobutyronitrile)","volume":"49","author":"Tabka","year":"2000","journal-title":"Polym. Int"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1101","DOI":"10.1016\/S0016-2361(99)00246-X","article-title":"Development of a model system to study fuel autoxidation in supercritical media: Decomposition kinetics of 2,2\u2032-azobis(isobutyronitrile) in supercritical carbon dioxide","volume":"79","author":"Morris","year":"2000","journal-title":"Fuel"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1016\/j.ijthermalsci.2006.08.002","article-title":"Fabrication, modeling and testing of a thin film Au\/Ti microheater","volume":"46","author":"Zhang","year":"2007","journal-title":"Int. J. Therm. Sci"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1548","DOI":"10.1039\/b610567j","article-title":"PDMS bonding by means of a protable, low-cost corona system","volume":"6","author":"Haubert","year":"2006","journal-title":"Lab Chip"},{"unstructured":"Park, K, Yarng, S, Kim, J, Kim, TS, and Yoon, E.-S (2009, January 2\u20136). Improvement of locomotive performance of capsular microrobot moving in GI tract using position based feedback control. Minneapolis, MN, USA.","key":"ref_16"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/7\/6978\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:56:39Z","timestamp":1760219799000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/7\/6978"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,7,4]]},"references-count":16,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2011,7]]}},"alternative-id":["s110706978"],"URL":"https:\/\/doi.org\/10.3390\/s110706978","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2011,7,4]]}}}