{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,12]],"date-time":"2026-02-12T13:00:35Z","timestamp":1770901235528,"version":"3.50.1"},"reference-count":48,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2011,9,13]],"date-time":"2011-09-13T00:00:00Z","timestamp":1315872000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The construction and characterization of a new ion-selective electrode for the determination of the antipsychotic ziprasidone in mixed solvents is presented. The electrode contains a plasticized polymeric membrane based on a ziprasidone-tetraphenylborate ion-exchanger. The influence of membrane composition on the electrode response towards ziprasidone in hydroalcoholic solutions was studied. The electrode displayed a stable response in a 2:3 (v\/v) methanol\/water medium from a ziprasidone concentration of 3 \u00d7 10\u22126 M with a fast response time of less than 20 s. The electrode also showed good selectivity towards ziprasidone over common inorganic and organic compounds and several species with pharmacological activity. The electrode was successfully applied to the determination of ziprasidone in pharmaceuticals and human urine and serum.<\/jats:p>","DOI":"10.3390\/s110908813","type":"journal-article","created":{"date-parts":[[2011,9,15]],"date-time":"2011-09-15T16:44:05Z","timestamp":1316105045000},"page":"8813-8825","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Use of a New Ziprasidone-Selective Electrode in Mixed Solvents and Its Application in the Analysis of Pharmaceuticals and Biological Fluids"],"prefix":"10.3390","volume":"11","author":[{"given":"M\u00aa Soledad","family":"Garc\u00eda","sequence":"first","affiliation":[{"name":"Department of Analytical Chemistry, Faculty of Chemistry, University of Murcia, E-30100 Murcia, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joaqu\u00edn A.","family":"Ortu\u00f1o","sequence":"additional","affiliation":[{"name":"Department of Analytical Chemistry, Faculty of Chemistry, University of Murcia, E-30100 Murcia, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mar\u00eda","family":"Cuartero","sequence":"additional","affiliation":[{"name":"Department of Analytical Chemistry, Faculty of Chemistry, University of Murcia, E-30100 Murcia, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mustafa Salem","family":"Abuherba","sequence":"additional","affiliation":[{"name":"Department of Analytical Chemistry, Faculty of Chemistry, University of Murcia, E-30100 Murcia, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2011,9,13]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/S0378-5173(02)00334-4","article-title":"Solubilization by cosolvents. Establishing useful constants for the log-linear model","volume":"245","author":"Millard","year":"2002","journal-title":"Int. J. Pharm"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2029","DOI":"10.1351\/pac198355122029","article-title":"Applications of ion-selective electrodes in nonaqueous and mixed-solvents","volume":"55","author":"Pungor","year":"1983","journal-title":"Pure Appl. Chem"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1021\/cr00103a009","article-title":"Applications of potentiometric ion sensors in the characterization of nonaqueous solvents","volume":"90","author":"Coetzee","year":"1990","journal-title":"Chem. Rev"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1039\/ai9953200263","article-title":"Neutral carrier and organic resin based membranes as sensors for uranyl ions","volume":"32","author":"Jain","year":"1995","journal-title":"Anal. Proc"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1039\/ai9953200099","article-title":"Copper(II)-selective electrodes based on macrocyclic compounds","volume":"32","author":"Jain","year":"1995","journal-title":"Anal. Proc"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"938","DOI":"10.1002\/elan.1140081017","article-title":"A PVC-Based Benzo-15-Crown-5 membrane sensor for cadmium","volume":"8","author":"Srivastava","year":"1996","journal-title":"Electroanalysis"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1272","DOI":"10.1021\/ac9507000","article-title":"PVC-based 2,2,2-cryptand sensor for zinc ions","volume":"68","author":"Srivastava","year":"1996","journal-title":"Anal. Chem"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1039\/a608421d","article-title":"Macrocycle based membrane sensors for the determination of cobalt(II) ions","volume":"122","author":"Jain","year":"1997","journal-title":"Analyst"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/S0003-2670(97)81609-1","article-title":"Porphyrins as carrier in PVC based membrane potentiometric sensors for nickel(II)","volume":"355","author":"Gupta","year":"1997","journal-title":"Anal. Chim. Acta"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1002\/(SICI)1521-4109(199906)11:8<573::AID-ELAN573>3.0.CO;2-Z","article-title":"Determination of uranyl ions using poly(vinyl chloride) based 4-tert-butylcalix[6]arene membrane sensor","volume":"11","author":"Gupta","year":"1999","journal-title":"Electroanalysis"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1039\/a901162e","article-title":"Chromium(III)-selective electrode based on a macrocyclic compound","volume":"124","author":"Singh","year":"1999","journal-title":"Analyst"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/S0003-2670(99)00154-3","article-title":"Cadmium(II)-selective sensors based on dibenzo-24-crown-8 in PVC matrix","volume":"389","author":"Gupta","year":"1999","journal-title":"Anal. Chim. Acta"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1127","DOI":"10.1002\/1521-4109(200208)14:15\/16<1127::AID-ELAN1127>3.0.CO;2-7","article-title":"Pb(II) selective potentiometric sensor based on 4-tert-butylcalix[4]arene in PVC matrix","volume":"14","author":"Gupta","year":"2002","journal-title":"Electroanalysis"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"125","DOI":"10.3390\/s40800125","article-title":"Samarium (III) selective membrane sensor based on tin (IV) boratophosphate","volume":"4","author":"Mittal","year":"2004","journal-title":"Sensors"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"801","DOI":"10.1016\/j.talanta.2003.10.001","article-title":"PVC-based dicyclohexano-18-crown-6 sensor for La(III) ions","volume":"62","author":"Mittal","year":"2004","journal-title":"Talanta"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.aca.2004.06.059","article-title":"Polymeric membrane sensor for potentiometric determination of vanadyl ions","volume":"527","author":"Moghimi","year":"2004","journal-title":"Anal. Chim. Acta"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.aca.2005.08.016","article-title":"Ni(II)-selective ion sensors of salen type Schiff base chelates","volume":"553","author":"Jain","year":"2005","journal-title":"Anal. Chim. Acta"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.aca.2006.07.022","article-title":"Potentiometric membrane sensor based on 6-(4-nitrophenyl)-2,4-diphenyl-3,5-diaza-bicyclo[3.1.0]hex-2-ene for detection of Sn(II) in real samples","volume":"579","author":"Arvand","year":"2006","journal-title":"Anal. Chim. Acta"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"2547","DOI":"10.1016\/j.electacta.2005.07.040","article-title":"A comparative study of Pb2+ selective sensors based on derivatized tetrapyrazole and calix[4]arene receptors","volume":"51","author":"Jain","year":"2006","journal-title":"Electrochim. Acta"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1016\/j.aca.2006.05.090","article-title":"A cerium(III) selective polyvinyl chloride membrane sensor based on a Schiff base complex of N,N\u2032-bis[2-(salicylideneamino)ethyl]ethane-1,2-diamine","volume":"575","author":"Gupta","year":"2006","journal-title":"Anal. Chim. Acta"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/j.aca.2006.11.074","article-title":"Chromium(III) selective membrane sensors based on Schiff bases as chelating ionophores","volume":"585","author":"Singh","year":"2007","journal-title":"Anal. Chim. Acta"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1016\/j.aca.2006.10.039","article-title":"Schiff bases as cadmium(II) selective ionophores in polymeric membrane electrodes","volume":"583","author":"Gupta","year":"2007","journal-title":"Anal. Chim. Acta"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1016\/j.talanta.2007.04.049","article-title":"Ni2+ selective sensors based on meso-tetrakis-{4-[tris-(4-allyldimethylsilylphenyl)silyl]phenyl}porphyrin and (sal)(2)triene in poly(vinyl chloride) matrix","volume":"73","author":"Gupta","year":"2007","journal-title":"Talanta"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/j.aca.2008.06.054","article-title":"Ni(II) selective sensors based on Schiff bases membranes in poly(vinyl chloride)","volume":"624","author":"Gupta","year":"2008","journal-title":"Anal. Chim. Acta"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"33","DOI":"10.2116\/analsci.25.33","article-title":"Development and application of ion-selective electrodes in nonaqueous solutions","volume":"25","author":"Nakamura","year":"2009","journal-title":"Anal. Sci"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.aca.2005.02.008","article-title":"Anion recognition through modified calixarenes: A highly selective sensor for monohydrogen phosphate","volume":"538","author":"Gupta","year":"2005","journal-title":"Anal. Chim. Acta"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1016\/j.talanta.2004.07.041","article-title":"Anion recognition through novel C-thiophenecalix[4]resorcinarene: PVC based sensor for chromate ions","volume":"65","author":"Jaina","year":"2005","journal-title":"Talanta"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.aca.2004.05.017","article-title":"Membrane electrode sensitive to a cationic surfactant in aquo-organic media","volume":"518","author":"Patil","year":"2004","journal-title":"Anal. Chim. Acta"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1299","DOI":"10.1039\/an9871201299","article-title":"Development of ion-selective electrodes for use in the titration of ionic surfactants in mixed-solvent systems","volume":"112","author":"Dowle","year":"1987","journal-title":"Analyst"},{"key":"ref_30","first-page":"13","article-title":"Celecoxib, a cox-2-specific inhibitor: The clinical data","volume":"28","author":"Fort","year":"1999","journal-title":"Am. J. Orthop"},{"key":"ref_31","first-page":"223","article-title":"Spectrophotometric methods for the determination of ziprasidone hydrochloride monohydrate in bulk and capsules","volume":"31","author":"Reddy","year":"2005","journal-title":"Acta Ciencia Indica Chem"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1155\/2006\/643624","article-title":"Spectrophotometric determination of Ziprasidone in pharmaceutical formulations","volume":"3","author":"Srinubabu","year":"2006","journal-title":"E-J. Chem"},{"key":"ref_33","first-page":"819","article-title":"UV spectrophotometric determination of ziprasidone hydrochloride in pore and pharmaceutical formulation","volume":"19","author":"Chauhan","year":"2007","journal-title":"Asian J. Chem"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1002\/bmc.299","article-title":"Stability indicating reversed-phase high-performance liquid chromatographic and thin layer densitometric methods for the determination of ziprasidone in bulk powder and in pharmaceutical formulations","volume":"18","author":"Rashed","year":"2004","journal-title":"Biomed. Chromatogr"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1016\/j.jpba.2007.11.010","article-title":"Determination of ziprasidone in pharmaceutical formulations by capillary zone electrophoresis","volume":"46","author":"Farin","year":"2008","journal-title":"J. Pharm. Biomed. Anal"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1016\/j.talanta.2010.04.036","article-title":"Electroanalytical characteristics of antipsychotic drug ziprasidone and its determination in pharmaceuticals and serum samples on solid electrodes","volume":"82","author":"Kul","year":"2010","journal-title":"Talanta"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1016\/0378-4347(95)00071-P","article-title":"Development and validation of a high-sensitivity assay for an antipsychotic agent, CP-88,059, with solid-phase extraction and narrow-bore highperformance liquid chromatography","volume":"668","author":"Janiszewski","year":"1995","journal-title":"J. Chromatogr. B"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/j.jchromb.2003.10.027","article-title":"Determination of ziprasidone using liquid chromatography with fluorescence detection","volume":"799","author":"Suckow","year":"2004","journal-title":"J. Chromatogr. B"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1097\/01.ftd.0000150879.36296.4d","article-title":"Automated determination of ziprasidone by HPLC with column switching and spectrophotometric detection","volume":"27","author":"Sachse","year":"2005","journal-title":"Ther. Drug Monit"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1002\/bmc.571","article-title":"Rapid liquid chromatography-tandem mass spectrometry method for quantification of ziprasidone in human plasma","volume":"20","author":"Aldirbashi","year":"2006","journal-title":"Biomed. Chromatogr"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.jchromb.2006.10.024","article-title":"Determination of ziprasidone in human plasma by liquid chromatography-electrospray tandem mass spectrometry and its application to plasma level determination in schizophrenia patients","volume":"847","author":"Aravagiri","year":"2007","journal-title":"J. Chromatogr. B"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1563","DOI":"10.1007\/s00216-009-2699-7","article-title":"Application of a trazodone-selective electrode to pharmaceutical quality control and urine analyses","volume":"394","author":"Albero","year":"2009","journal-title":"Anal. Bioanal. Chem"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"1175","DOI":"10.1016\/j.talanta.2008.01.014","article-title":"PVC membrane electrode for the potentiometric determination of Ipratropium bromide using batch and flow injection techniques","volume":"75","author":"Hassouna","year":"2008","journal-title":"Talanta"},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Koryta, J, and Stulik, K (1983). Ion-Selective Electrodes, Cambridge University Press. [2nd ed].","DOI":"10.1017\/CBO9780511897610"},{"key":"ref_45","unstructured":"Senike, T, and Hasegawa, Y (1977). Solvent Extraction Chemistry Fundamentals and Applications, Marcel Dekker."},{"key":"ref_46","unstructured":"Swartz, ME, and Krull, IS (1997). Analytical Method Development and Validation, Marcel Dekker."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"1","DOI":"10.2174\/1874065001005010001","article-title":"The role of and the place of method validation in drug analysis using electroanalytical techniques","volume":"5","author":"Gumustas","year":"2011","journal-title":"Open Anal. Chem. J"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"1851","DOI":"10.1351\/pac200072101851","article-title":"Selectivity coefficients of ion-selective electrodes","volume":"72","author":"Umezawa","year":"2000","journal-title":"Pure Appl. Chem"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/9\/8813\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:57:22Z","timestamp":1760219842000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/9\/8813"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,9,13]]},"references-count":48,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2011,9]]}},"alternative-id":["s110908813"],"URL":"https:\/\/doi.org\/10.3390\/s110908813","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,9,13]]}}}