{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:37:38Z","timestamp":1760243858664,"version":"build-2065373602"},"reference-count":17,"publisher":"MDPI AG","issue":"10","license":[{"start":{"date-parts":[[2011,10,12]],"date-time":"2011-10-12T00:00:00Z","timestamp":1318377600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Finite element method analysis was applied to the characterization of the biomolecular interactions taking place in a microfluidic assisted microarray. Numerical simulations have been used for the optimization of geometrical and physical parameters of the sensing device. Different configurations have been analyzed and general considerations have been derived. We have shown that a parallel disposition of the sensing area allows the homogeneous formation of the target molecular complex in all the active zones of the microarray. Stationary and time dependent results have also been obtained.<\/jats:p>","DOI":"10.3390\/s111009658","type":"journal-article","created":{"date-parts":[[2011,10,12]],"date-time":"2011-10-12T10:41:24Z","timestamp":1318416084000},"page":"9658-9666","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Numerical Optimization of a Microfluidic Assisted Microarray for the Detection of Biochemical Interactions"],"prefix":"10.3390","volume":"11","author":[{"given":"Emanuele","family":"Orabona","sequence":"first","affiliation":[{"name":"Institute for Microelectronics and Microsystems, Naples Unit, National Research Council, Via P. Castellino 111, 80131 Napoli, Italy"},{"name":"Department of Physics, University of Naples \u201cFederico II\u201d, Via Cinthia, 80128 Napoli, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ilaria","family":"Rea","sequence":"additional","affiliation":[{"name":"Institute for Microelectronics and Microsystems, Naples Unit, National Research Council, Via P. Castellino 111, 80131 Napoli, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ivo","family":"Rendina","sequence":"additional","affiliation":[{"name":"Institute for Microelectronics and Microsystems, Naples Unit, National Research Council, Via P. Castellino 111, 80131 Napoli, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luca De","family":"Stefano","sequence":"additional","affiliation":[{"name":"Institute for Microelectronics and Microsystems, Naples Unit, National Research Council, Via P. Castellino 111, 80131 Napoli, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2011,10,12]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"6623","DOI":"10.3390\/s100706623","article-title":"Microfluidic systems for biosensing","volume":"10","author":"Liu","year":"2010","journal-title":"Sensors"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1002\/jbio.200810018","article-title":"Microfluidics and photonics for Bio-System-on-a-Chip: A review of advancements in technology towards a microfluidic flow cytometry chip","volume":"1","author":"Godin","year":"2008","journal-title":"J. Biophotonics"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"822","DOI":"10.1364\/OE.18.000822","article-title":"Rotational dynamics of optically trapped nanofibers","volume":"18","author":"Neves","year":"2010","journal-title":"Opt. Express"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"7515","DOI":"10.1021\/nn1018126","article-title":"Brownian motion of graphene","volume":"4","author":"Bonaccorso","year":"2010","journal-title":"ACS Nano"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/j.ymeth.2005.05.011","article-title":"Microcantilever biosensors","volume":"37","author":"Hansen","year":"2005","journal-title":"Methods"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1007\/s00216-003-2101-0","article-title":"Present and future of surface plasmon resonance biosensors","volume":"377","author":"Homola","year":"2003","journal-title":"Anal. Bioanal. Chem"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"214","DOI":"10.3390\/s7020214","article-title":"DNA optical detection based on porous silicon technology: From biosensors to biochips","volume":"7","author":"Arcari","year":"2007","journal-title":"Sensors"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"014513","DOI":"10.1063\/1.3273410","article-title":"Fabrication and characterization of a porous silicon based microarray for label-free optical monitoring of biomolecular interactions","volume":"107","author":"Rea","year":"2010","journal-title":"J Appl Phys"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2062","DOI":"10.1039\/b813350f","article-title":"Effect of volume- and time-based constraints on capture of analytes in microfluidic heterogeneous immunoassays","volume":"8","author":"Parsa","year":"2008","journal-title":"Lab Chip"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"3233","DOI":"10.1021\/nl801559m","article-title":"Numerical characterization and optimization of the microfluidics for nanowire biosensors","volume":"8","author":"Kim","year":"2008","journal-title":"Nano Lett"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"113904","DOI":"10.1063\/1.2784941","article-title":"Two dimensional simulation on immunoassay for a biosensor with applying electrothermal effect","volume":"91","author":"Yang","year":"2007","journal-title":"Appl. Phys. Lett"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"6456","DOI":"10.3390\/s90806456","article-title":"A novel design of grooved fibers for fiber-optic localized plasmon resonance biosensors","volume":"9","author":"Huang","year":"2009","journal-title":"Sensors"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1403","DOI":"10.1016\/j.bios.2006.06.017","article-title":"Modeling micropatterned antigen-antibody binding kinetics in a microfluidic chip","volume":"22","author":"Hu","year":"2007","journal-title":"Biosens. Bioelectron"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1163","DOI":"10.1039\/b605507a","article-title":"Recirculating flow accelerates DNA microarray hybridization in a microfluidic device","volume":"6","author":"Lee","year":"2006","journal-title":"Lab Chip"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1016\/j.snb.2009.04.071","article-title":"Microfluidic reactor array device for massively parallel in situ synthesis of oligonucleotides","volume":"140","author":"Srivannavit","year":"2009","journal-title":"Sens. Actuat. B"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1002\/(SICI)1099-1352(199911\/12)12:6<390::AID-JMR482>3.0.CO;2-8","article-title":"Survey of the 1998 optical biosensor literature","volume":"12","author":"Myszka","year":"1999","journal-title":"J. Mol. Recognit"},{"key":"ref_17","unstructured":"Bruus, H (2007). MIC\u2013Supplementary Lecture Notes, Technical University of Denmark. [2nd ed]."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/10\/9658\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:57:39Z","timestamp":1760219859000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/11\/10\/9658"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,10,12]]},"references-count":17,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2011,10]]}},"alternative-id":["s111009658"],"URL":"https:\/\/doi.org\/10.3390\/s111009658","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2011,10,12]]}}}