{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T04:53:52Z","timestamp":1790398432618,"version":"4.1.0"},"reference-count":22,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2011,12,22]],"date-time":"2011-12-22T00:00:00Z","timestamp":1324512000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This paper addresses the challenging problem of ultrasonic non-destructive evaluation (NDE) imaging with adaptive transducer arrays. In NDE applications, most materials like concrete, stainless steel and carbon-reinforced composites used extensively in industries and civil engineering exhibit heterogeneous internal structure. When inspected using ultrasound, the signals from defects are significantly corrupted by the echoes form randomly distributed scatterers, even defects that are much larger than these random reflectors are difficult to detect with the conventional delay-and-sum operation. We propose to apply adaptive beamforming to the received data samples to reduce the interference and clutter noise. Beamforming is to manipulate the array beam pattern by appropriately weighting the per-element delayed data samples prior to summing them. The adaptive weights are computed from the statistical analysis of the data samples. This delay-weight-and-sum process can be explained as applying a lateral spatial filter to the signals across the probe aperture. Simulations show that the clutter noise is reduced by more than 30 dB and the lateral resolution is enhanced simultaneously when adaptive beamforming is applied. In experiments inspecting a steel block with side-drilled holes, good quantitative agreement with simulation results is demonstrated.<\/jats:p>","DOI":"10.3390\/s120100042","type":"journal-article","created":{"date-parts":[[2011,12,22]],"date-time":"2011-12-22T12:22:42Z","timestamp":1324556562000},"page":"42-54","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":38,"title":["Ultrasound Nondestructive Evaluation (NDE) Imaging with Transducer Arrays and Adaptive Processing"],"prefix":"10.3390","volume":"12","author":[{"given":"Minghui","family":"Li","sequence":"first","affiliation":[{"name":"Centre for Ultrasonic Engineering, Department of Electronic and Electrical Engineering, University of Strathclyde, 204 George Street, Glasgow G1 1XW, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gordon","family":"Hayward","sequence":"additional","affiliation":[{"name":"Centre for Ultrasonic Engineering, Department of Electronic and Electrical Engineering, University of Strathclyde, 204 George Street, Glasgow G1 1XW, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2011,12,22]]},"reference":[{"key":"ref_1","unstructured":"Chen, C.H. (2007). Ultrasonic and Advanced Methods for Non-Destructive Testing and Material Characterization, World Scientific Publishing Co."},{"key":"ref_2","unstructured":"Dube, N. (2005). Introduction to Phased Array Ultrasonic Technology Applications: R\/D Tech Guideline, R\/D Tech Co.. Advanced Practical NDT Series;."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1109\/58.294109","article-title":"Analytical evaluation of sampled aperture ultrasonic imaging techniques for NDE","volume":"41","author":"Chiao","year":"1994","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1596","DOI":"10.1109\/TUFFC.2002.1049742","article-title":"Capacitive micormachined ultrasonic transducers: Next generation array for acoustic imaging","volume":"49","author":"Oralkan","year":"2002","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1016\/j.ndteint.2005.04.002","article-title":"Post-processing of the full matrix of ultrasonic transmit-receive array data for non-destructive evaluation","volume":"38","author":"Holmes","year":"2005","journal-title":"NDT E Int"},{"key":"ref_6","unstructured":"Kremkau, F. (2002). Diagnostic Ultrasound: Principles and Instruments, WB Saunders Company."},{"key":"ref_7","unstructured":"Mann, J.A., and Walker, W.F. (2002, January 8\u201311). A Constrained Adaptive Beamformer for Medical Ultrasound: Initial Results. Munich, Germany."},{"key":"ref_8","unstructured":"Sasso, M., and Cohen-Bacrie, C. (2005, January 19\u201323). Medical Ultrasound Imaging Using the Fully Adaptive Beamformer. Philadelphia, PA, USA."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1308","DOI":"10.1109\/TMI.2005.857222","article-title":"Time-delay- and time-reversal-based robust Capon beamformers for ultrasound imaging","volume":"24","author":"Wang","year":"2005","journal-title":"IEEE Trans. Med. Imag"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1868","DOI":"10.1109\/TUFFC.2009.1263","article-title":"Benefits of minimum-variance beamforming in medical ultrasound imaging","volume":"56","author":"Synnevag","year":"2009","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"958","DOI":"10.1109\/TUFFC.2009.1128","article-title":"Phase coherence imaging","volume":"56","author":"Camacho","year":"2009","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1109\/TUFFC.2007.247","article-title":"Optimal apodization design for medical ultrasound using constrained least squares. Part I: Theory","volume":"54","author":"Guenther","year":"2007","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1109\/TUFFC.2007.248","article-title":"Optimal apodization design for medical ultrasound using constrained least squares. Part II: Simulation results","volume":"54","author":"Guenther","year":"2007","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1109\/7.366309","article-title":"Nonlinear apodization for side lobe control in SAR imagery","volume":"31","author":"Stankwitz","year":"1995","journal-title":"IEEE Trans. Aerosp. Electron. Syst"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1109\/T-UFFC.1986.26848","article-title":"Analysis and comparison of some frequency compounding algorithms for the reduction of ultrasonic clutter","volume":"33","author":"Amir","year":"1986","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1408","DOI":"10.1109\/PROC.1969.7278","article-title":"High-resolution frequency-wavenumber spectrum analysis","volume":"57","author":"Capon","year":"1969","journal-title":"Proc. IEEE"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1002\/wcm.228","article-title":"Accurate direction-of-arrival estimation of multiple sources using a genetic approach","volume":"5","author":"Li","year":"2005","journal-title":"Wirel. Commun. Mob. Comput"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1813","DOI":"10.1016\/j.sigpro.2004.06.009","article-title":"Improving the performance of GA-ML DOA estimator with a resampling scheme","volume":"84","author":"Li","year":"2004","journal-title":"Sign. Process"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1361","DOI":"10.1109\/TAES.2009.5310304","article-title":"Source bearing and steering-vector estimation using partially calibrated arrays","volume":"45","author":"Li","year":"2009","journal-title":"IEEE Trans. Aerosp. Electron. Syst"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1109\/TAES.2008.4655365","article-title":"Maximum likelihood DOA estimation in unknown colored noise fields","volume":"44","author":"Li","year":"2008","journal-title":"IEEE Trans. Aerosp. Electron. Syst"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1109\/TAES.2006.1603408","article-title":"Dimension reduction for array processing with robust interference cancellation","volume":"42","author":"Li","year":"2006","journal-title":"IEEE Trans. Aerosp. Electron. Syst"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1702","DOI":"10.1109\/TSP.2003.812831","article-title":"On robust Capon beamforming and diagonal loading","volume":"51","author":"Li","year":"2003","journal-title":"IEEE Trans. Sign. Process"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/12\/1\/42\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:58:27Z","timestamp":1760219907000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/12\/1\/42"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,12,22]]},"references-count":22,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2012,1]]}},"alternative-id":["s120100042"],"URL":"https:\/\/doi.org\/10.3390\/s120100042","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,12,22]]}}}