{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T17:15:02Z","timestamp":1785604502526,"version":"3.56.0"},"reference-count":94,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2011,12,28]],"date-time":"2011-12-28T00:00:00Z","timestamp":1325030400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Implanted medical devices are very important electronic devices because of their usefulness in monitoring and diagnosis, safety and comfort for patients. Since 1950s, remarkable efforts have been undertaken for the development of bio-medical implanted and wireless telemetry bio-devices. Issues such as design of suitable modulation methods, use of power and monitoring devices, transfer energy from external to internal parts with high efficiency and high data rates and low power consumption all play an important role in the development of implantable devices. This paper provides a comprehensive survey on various modulation and demodulation techniques such as amplitude shift keying (ASK), frequency shift keying (FSK) and phase shift keying (PSK) of the existing wireless implanted devices. The details of specifications, including carrier frequency, CMOS size, data rate, power consumption and supply, chip area and application of the various modulation schemes of the implanted devices are investigated and summarized in the tables along with the corresponding key references. Current challenges and problems of the typical modulation applications of these technologies are illustrated with a brief suggestions and discussion for the progress of implanted device research in the future. It is observed that the prime requisites for the good quality of the implanted devices and their reliability are the energy transformation, data rate, CMOS size, power consumption and operation frequency. This review will hopefully lead to increasing efforts towards the development of low powered, high efficient, high data rate and reliable implanted devices.<\/jats:p>","DOI":"10.3390\/s120100297","type":"journal-article","created":{"date-parts":[[2011,12,28]],"date-time":"2011-12-28T12:01:29Z","timestamp":1325073689000},"page":"297-319","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":88,"title":["Modulation Techniques for Biomedical Implanted Devices and Their Challenges"],"prefix":"10.3390","volume":"12","author":[{"given":"Mahammad A.","family":"Hannan","sequence":"first","affiliation":[{"name":"Department of Electrical, Electronic & Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM Bangi Selangor, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saad M.","family":"Abbas","sequence":"additional","affiliation":[{"name":"Department of Electrical, Electronic & Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM Bangi Selangor, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Salina A.","family":"Samad","sequence":"additional","affiliation":[{"name":"Department of Electrical, Electronic & Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM Bangi Selangor, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aini","family":"Hussain","sequence":"additional","affiliation":[{"name":"Department of Electrical, Electronic & Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM Bangi Selangor, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2011,12,28]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1109\/MEMB.2009.933571","article-title":"From Frankenstein to the Pacemaker: A Profile of the Bakken Museum","volume":"28","author":"Rhees","year":"2009","journal-title":"IEEE Eng. Med. Biol. Mag"},{"key":"ref_2","unstructured":"Yekeh, K., and Kohno, R. (2007, January 11\u201314). Wireless Communications for Body Implanted Medical Devices. Bangkok, Thailand."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1109\/TBCAS.2008.2005295","article-title":"Power-Efficient Impedance-Modulation Wireless Data Links for Biomedical Implants","volume":"2","author":"Madal","year":"2008","journal-title":"IEEE Trans. Biomed. Circ. Syst"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1109\/MEMB.2005.1511503","article-title":"Thermal Effects of Bio-Implants","volume":"24","author":"Lazzi","year":"2005","journal-title":"IEEE Eng. Med. Biol. Mag"},{"key":"ref_5","first-page":"47","article-title":"Effect of Low Frequency Pulsed DC on Human Skin In Vivo: Resistance Studies in Reverse Lontophoresis","volume":"104","author":"Kathuroju","year":"2009","journal-title":"Sens. Transduc. J"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Asgarian, F., and Sodagar, A.M. (2009, January 2\u20136). A Low-Power Non Coherent BPSK Demodulator and Clock Recovery Circuit for High-Data-Rate Biomedical Applications. Minneapolis, MN, USA.","DOI":"10.1109\/IEMBS.2009.5332664"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1109\/TBCAS.2010.2044573","article-title":"HermesD: A high-Rate Long-Range Wireless Transmission System for Simultaneous Multichannel Neural Recording Applications","volume":"4","author":"Miranda","year":"2010","journal-title":"IEEE Trans. Biomed. Circ. Syst"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Atluri, S., and Ghovanloo, M. (2007, January 27\u201330). Incorporating Back Telemetry in a Full-Wave CMOS Rectifier for RFID and Biomedical Applications. New Orleans, LA, USA.","DOI":"10.1109\/ISCAS.2007.378007"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"785","DOI":"10.3390\/s110100785","article-title":"Optical Microspherical Resonators for Biomedical Sensing","volume":"11","author":"Soria","year":"2011","journal-title":"Sensors"},{"key":"ref_10","first-page":"57","article-title":"Advances in Cochlear Implant Implementation","volume":"2","author":"Bhoir","year":"2009","journal-title":"Int. J. Recent Trend. Eng"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1277","DOI":"10.3390\/s110201277","article-title":"Energy Efficiency Analysis of a Distributed Queuing Medium Access Control Protocol for Biomedical Wireless Sensor Networks in Saturation Conditions","volume":"11","author":"Otal","year":"2011","journal-title":"Sensors"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"150","DOI":"10.3390\/jlpea1010150","article-title":"Data-Driven Approaches for Computation in Intelligent Biomedical Devices: A Case Study of EEG Monitoring for Chronic Seizure Detection","volume":"1","author":"Verma","year":"2011","journal-title":"J. Low Power Electron. Appl"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"7022","DOI":"10.3390\/s110707022","article-title":"An Asynchronous Multi-Sensor Micro Control Unit for Wireless Body Sensor Networks (WBSNs)","volume":"11","author":"Chen","year":"2011","journal-title":"Sensors"},{"key":"ref_14","unstructured":"Kopparthi, S., and Ajmera, P.K. (2004, January 2\u20134). Power Delivery for Remotely Located Microsystems. Norman, OK, USA."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Ma, Q., Haider, M.R., Song, Y., and Islam, S.K. (2010, January 1\u20134). Power-Oscillator Based High Efficiency Inductive Power-Link for Transcutaneous Power Transmission. Seattel, WA, USA.","DOI":"10.1109\/MWSCAS.2010.5548748"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1109\/TBCAS.2008.918284","article-title":"A Frequency Control Method for Regulating Wireless Power to Implantable Devices","volume":"2","author":"Si","year":"2008","journal-title":"IEEE Trans. Biomed. Circ. Syst"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2010","DOI":"10.1109\/TUFFC.2009.1277","article-title":"Power Harvesting Using PZT Ceramics Embedded in Orthopedic Implants","volume":"56","author":"Chen","year":"2009","journal-title":"IEEE Trans. Ultras. Ferroelectr. Freq. Control"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"638","DOI":"10.3390\/s110100638","article-title":"Sensing Movement: Microsensors for Body Motion Measurement","volume":"11","author":"Zeng","year":"2011","journal-title":"Sensors"},{"key":"ref_19","first-page":"75","article-title":"Wireless Sensor Network for Brain Computer Interface","volume":"8","author":"Baporikar","year":"2009","journal-title":"Int. J. Adv. Eng. Sci. Tech"},{"key":"ref_20","unstructured":"Inoue, K., Shiba, K., Shu, E., Koshiji, K., Tsukahara, K., Ohu-mi, T., Masuzawa, T., Tatsumi, E., Taenaka, Y., and Takano, H. (November, January 30). Transcutaneous Optical Telemetry System Investigation on Deviation Characteristics. Chicago, IL, USA."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1109\/JMEMS.2004.839650","article-title":"A Wireless Microsystem for the Remote Sensing of Pressure, Temperature, and Relative Humidity","volume":"14","author":"DeHennis","year":"2005","journal-title":"J. Microelectromech. Syst"},{"key":"ref_22","unstructured":"Ziemer, R.E., and Tranter, W.H. (2010). Principles of Communications Systems, Modulation, and Noise, John Wily & Sons."},{"key":"ref_23","unstructured":"Klaus, F. (2003). RFID Handbook: Fundamentals and Applications in Contactless Smart Cards and Identification, Wiley & Sons. [2nd ed]."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1109\/86.372900","article-title":"Electronic Design of a Cochlear Implantant for Multi-Channel High Rate Pulsatle Stimulation Strategies","volume":"3","author":"Zierhofer","year":"1995","journal-title":"IEEE Trans. Rehab. Eng"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"598","DOI":"10.1093\/ietcom\/e89-b.2.598","article-title":"An ASK Modulator and Antenna Driver for 13.56 MHz RFID Readers and NFC Devices","volume":"89","author":"Cho","year":"2006","journal-title":"IEICE Trans. Commun"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1638","DOI":"10.1109\/TCOMM.2003.818103","article-title":"M-Ary Amplitude Shift Keying OFDM System","volume":"51","author":"Xiong","year":"2003","journal-title":"IEEE Trans. Commun"},{"key":"ref_27","unstructured":"Taub, H., and Schilling, D.L. (1999). Principle of Communication System, McGraw-Hill Companies."},{"key":"ref_28","unstructured":"Wang, C.-C., Hsueh, Y.-H., Chio, U.F., and Hsiao, Y.-T. (2004, January 23\u201326). A C-Less ASK Demodulator Implantable Neural Interfacing. Vancouver, BC, Canada."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Li, H., and Li, W. (2007, January 21\u201325). A High-Performance ASK Demodulator for Wireless Recovery System. Shanghai, China.","DOI":"10.1109\/WICOM.2007.307"},{"key":"ref_30","unstructured":"Yu, H, and Najafi, K. (2003, January 10\u201312). Low-Power Interface Circuits for Bio-Implantable Microsystems. San Francisco, CA, USA."},{"key":"ref_31","unstructured":"Djemouai, A., and Sawan, M. (2004, January 23\u201326). New CMOS Current-Mode Amplitude Shift Keying Demodulator (ASKD) Dedicated for Implantable Electronic Devices. Vancouver, BC, Canada."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Yu, H., and Basirullah, R. (2006, January 10\u201313). A Low Power ASK Clock and Data Recovery Circuit for Wireless Implantable Electronics. San Jose, CA, USA.","DOI":"10.1109\/CICC.2006.321005"},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Yu, H., Li, Y., Jiang, L., and Ji, Z. (2010, January 6\u20138). A 31 \u03bcw ASK Clock and Data Recovery Circuit for Wireless Implantable System. Chengdu, China.","DOI":"10.1109\/ISPACS.2010.5704714"},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Naghmouchi, F., Ghorbel, M., Hamida, A.B., and Samet, M. (2004, January 21\u201324). CMOS ASK System Modulation Dedicated to Cochler Prosthesis. Hammamet, Tunisia.","DOI":"10.1109\/ISCCSP.2004.1296276"},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Yan, H., Wu, D.-C., Liu, Y., Wang, D.-H., and Hou, C.-H. (2010, January 1\u20134). A Low-Power CMOS ASK Clock and Data Recovery Circuit for Cochlear Implants. Shanghai, China.","DOI":"10.1109\/ICSICT.2010.5667407"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1487","DOI":"10.1109\/4.871327","article-title":"A Neuro-Stimulus Chip with Telemetry Unit for Retinal Prosthetic Device","volume":"35","author":"Liu","year":"2000","journal-title":"IEEE J. Solid State Circuits"},{"key":"ref_37","unstructured":"Gudnason, G. (2000, January 19\u201321). A Low-Power ASK Demodulator for Inductively Coupled Implantable Electronics. Stockholm, Sweden."},{"key":"ref_38","unstructured":"Li, H., and Zhang, Y. (2008, January 8\u201310). Low Power Wireless Receiver in CMOS Mixed-Signal for Bio-Telemetry Implantable System. Hong Kong."},{"key":"ref_39","unstructured":"Han, S., Chi, B., and Wang, Z. (2006, January 11\u201313). 8.0-mW 1-Mbps ASK Transmitter for Wireless Capsule Endoscope Applications. San Francisco, CA, USA."},{"key":"ref_40","unstructured":"Djemouai, A., and Sawan, M. (2003, January 27\u201330). Integrated ASK Demodulator Dedicated to Implantable Electronic Devices. Cairo, Egypt."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1023\/A:1008328228307","article-title":"A Chip for an Implantable Neural Stimulator","volume":"22","author":"Gudnason","year":"1999","journal-title":"Analog Integr. Circ. Sign. Process"},{"key":"ref_42","unstructured":"Yu, H., and Najafi, K. (2001, January 25\u201328). Circuitry for a Wireless Microsystem for Neural Recording Microprobes. Istanbul, Turkey."},{"key":"ref_43","unstructured":"Dong, M., Zhang, C., Wang, Z., and Li, D. (2004, January 1\u20133). A Neurostimulus Chip with Telemetry Unit for Cochlear Implant. Singapore."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"2526","DOI":"10.1109\/TCSI.2005.857770","article-title":"An Implantable Wireless Bidirectional Communication Microstimulator for Neuromuscular Stimulation","volume":"52","author":"Lee","year":"2005","journal-title":"IEEE Trans. Circ. Syst"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1109\/TBME.2008.2003262","article-title":"A Wireless Bio-MEMS Sensor for C-Reactive Protein Detection Based on Nanomechanics","volume":"30","author":"Chen","year":"2009","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Gong, C.-S.A., Wu, C.-L., Ho, S.-Y., Chen, T.-Y., Huang, J.-C., Su, C.-W., Su, C.-H., Chang, Y., Cheng, K.-H., Lo, Y.-L., and Shiue, M.-T. (2006, January 10\u201313). Design of Self-Sampling Based ASK Demodulator for Implantable Microsystem. Nice, France.","DOI":"10.1109\/ICECS.2006.379674"},{"key":"ref_47","unstructured":"Liang, B., Yang, Z., and Liu, W. (2009, January 3\u20136). An ASK Demodulator for Data Telemetry in Biomedical Application. Minneapolis, MN, USA."},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Lee, T.-J., Lee, C.-L., Ciou, Y.-J., Huang, C.-C., and Wang, C.-C. (2007, January 26\u201328). C-Less and R-Less Low-Frequency ASK Demodulator for Wireless Implantable Devices. Singapore.","DOI":"10.1109\/ISICIR.2007.4441934"},{"key":"ref_49","first-page":"474","article-title":"All-MOS ASK Demodulator for Low-Frequency Applications","volume":"55","author":"Lee","year":"2008","journal-title":"IEEE Trans. Circ. Syst"},{"key":"ref_50","unstructured":"Huang, C.-C., Chen, C.-C, and Wang, C.-C. (2008, January 24\u201325). R-Less and C-Less Self-Sampled ASK Demodulator for Lower ISM Band Applications. Busan, Korea."},{"key":"ref_51","first-page":"1464","article-title":"Truly Low-Cost High-Efficiency ASK Demodulator Based on Self-Sampling Scheme for Bio-Implantable Applications","volume":"55","author":"Gong","year":"2008","journal-title":"IEEE Trans. Circ. Syst"},{"key":"ref_52","unstructured":"Kao, C.-H., and Tang, K.-T. (2009, January 9\u201310). Wireless Power and Data Transmission with ASK Demodulator and Power Regulator for a Biomedical Implantable SOC. Lissa Bethesda, MD, USA."},{"key":"ref_53","first-page":"265","article-title":"Self-Sampled All-MOS ASK Demodulator for Lower ISM Band Applications","volume":"57","author":"Wang","year":"2010","journal-title":"IEEE Trans. Circ. Syst"},{"key":"ref_54","doi-asserted-by":"crossref","unstructured":"Daoud, D., Ghorbel, M., Ben, H.A., and Tomas, J. (2011, January 22\u201325). Fully Integrated CMOS Data and Clock Recovery for Wireless Biomedical Implants. Sousse, Tunisia.","DOI":"10.1109\/SSD.2011.5767400"},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Proakis, J. (2002). Encyclopedia of Telecommunications, John Wiley & Sons, Inc.","DOI":"10.1002\/0471219282"},{"key":"ref_56","unstructured":"Lee, H.-K., and Park, D.-C. (2000, January 23\u201328). Bio-Medical FM-FM-FSK Radio Telemetry System for Multi-Signal Transmission. Chicago, IL, USA."},{"key":"ref_57","unstructured":"Ghovanloo, M., and Najafi, K. (2003, January 25\u201328). A High-Rate Frequency Shift Keying Demodulator Chip for Wireless Biomedical Implants. Bangkok, Thailand."},{"key":"ref_58","unstructured":"Chen, Z., Zhang, Z., and Lau, J. (July, January 29). A CMOS 2- and 4-FSK Demodulator for Direct-Conversion Radio Paging Receivers. Chengdu, China."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"1976","DOI":"10.1109\/JSSC.2004.835822","article-title":"Fully Integrated Wideband High-Current Rectifiers for Inductively Powered Devices","volume":"39","author":"Ghovanloo","year":"2004","journal-title":"IEEE J. Solid State Circ"},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"2374","DOI":"10.1109\/TCSI.2004.838144","article-title":"A Wideband Frequency-Shift Keying Wireless Link for Inductively Powered Biomedical Implants","volume":"51","author":"Ghovanloo","year":"2004","journal-title":"IEEE Trans. Circ. Syst"},{"key":"ref_61","doi-asserted-by":"crossref","unstructured":"Sodagar, A.M., and Najafi, K. (2006, January 6\u20139). Wireless Interfaces for Implantable Biomedical Microsystems. San Juan, Puerto Rico.","DOI":"10.1109\/MWSCAS.2006.382262"},{"key":"ref_62","unstructured":"Tekin, A., Yuce, M.R., Shabani, J., and Liu, W. (2006, January 17\u201319). A Low-Power FSK Modulator\/Demodulator for an MICS Band Transceiver. San Diego, CA, USA."},{"key":"ref_63","doi-asserted-by":"crossref","unstructured":"Wend, R.-M., Li, S.-Y., and Wang, J.-C. (2006, January 17\u201319). Low Power Frequency-Shift Keying Demodulators for Biomedical Implants. Tainan, Taiwan.","DOI":"10.1109\/EDSSC.2007.4450315"},{"key":"ref_64","doi-asserted-by":"crossref","unstructured":"Zhu, K., Haider, M.R., Yuan, S., and Islam, S.K. (2010, January 5\u20137). A Sub-1 \u03bcA Low-Power FSK Modulator for Biomedical Sensor Circuits. Lixouri, Greece.","DOI":"10.1109\/ISVLSI.2010.74"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1109\/TNSRE.2005.853625","article-title":"Wireless Multichannel Biopotential Recording Using an Integrated FM Telemetry Circuit","volume":"13","author":"Mohseni","year":"2005","journal-title":"IEEE Trans. Neural Syst. Rehab. Eng"},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1109\/JSSC.2006.886567","article-title":"A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System","volume":"42","author":"Harrison","year":"2007","journal-title":"IEEE J. Solid State Circ"},{"key":"ref_67","doi-asserted-by":"crossref","unstructured":"Haider, M.R., Mostafa, S., and Islam, S.K. (2008, January 10\u201313). A Low-Power Sensor Read-Out Circuit with FSK Telemetry for Inductively-Powered Implant System. Knoxville, TN, USA.","DOI":"10.1109\/MWSCAS.2008.4616833"},{"key":"ref_68","unstructured":"El-Gabaly, A., Jackson, B.R., and Saavedra, C.E. (August, January 30). An L-Band Direct Digital QPSK Modulation in CMOS. Montreal, QC, Canada."},{"key":"ref_69","doi-asserted-by":"crossref","unstructured":"Sonkusale, S., and Luo, Z. (2008, January 20\u201324). A Complete Data and Power Telemetry System Utilizing BPSK and LSK Signalling for Biomedical Implants. Vacouver, BC, Canada.","DOI":"10.1109\/IEMBS.2008.4649888"},{"key":"ref_70","unstructured":"Hu, Y., and Sawan, M. (2004, January 25\u201328). A Fully-Integrated Low-Power BPSK Based Wireless Inductive Link for Implantable Medical Devices. Hiroshima, Japan."},{"key":"ref_71","unstructured":"Lu, Z., and Sawan, M. (2008, January 18\u201321). An 8 Mbps Data Rate Transmission by Inductive Link Dedicated to Implantable Devices. Seattle, WA, USA."},{"key":"ref_72","first-page":"714","article-title":"Fullly Digital BPSK Demodulator and Multi Level LSK Back Telemetry for Biomedical Implant Transceivers","volume":"56","author":"Xu","year":"2009","journal-title":"IEEE Trans. Circ. Syst. II"},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1109\/TBCAS.2011.2126570","article-title":"A Low-Power Bidirectional Telemetry Device with a Near-Field Charging Feature for a Cardiac Microstimulator","volume":"5","author":"Lee","year":"2011","journal-title":"IEEE Trans. Biomed. Circ. Syst"},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"2552","DOI":"10.1109\/TCSI.2005.858163","article-title":"A Fully Integrated Low-Power BPSK Demodulator for Implantable Medical Devices","volume":"52","author":"Hu","year":"2005","journal-title":"IEEE Trans. Circ. Syst"},{"key":"ref_75","unstructured":"Deng, S., Hu, Y., and Sawan, M. (2006, January 21\u201324). A High Data Rate QPSK Demodulator for Inductively Powered Electronics Implants. Kos, Greece."},{"key":"ref_76","first-page":"1478","article-title":"A Novel BPSK Demodulator for Biological Implants","volume":"55","author":"Luo","year":"2008","journal-title":"IEEE Trans. Circ. Syst. Part I"},{"key":"ref_77","unstructured":"Zhou, M., Liu, W., Wang, G., Sivaprakasam, M., Yuce, M.R., Weiland, J.D., and Humayun, M.S. (September, January 30). A Transcutaneous Data Telemetry System Tolerant to Power Telemetry Interference. New York, NY, USA."},{"key":"ref_78","doi-asserted-by":"crossref","unstructured":"Zhou, M., and Liu, W. (2007, January 11\u201315). A Non-Coherent PSK Receiver with Interference-Canceling for Transcutaneous Neural Implants. San Francisco, CA, USA.","DOI":"10.1109\/ISSCC.2007.373635"},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"2003","DOI":"10.1109\/JSSC.2008.2001881","article-title":"A Non-Coherent DPSK Data Receiver with Interference Cancellation for Dual-Band Transcutaneous Telemetries","volume":"43","author":"Zhou","year":"2008","journal-title":"IEEE J. Sold State Circ"},{"key":"ref_80","doi-asserted-by":"crossref","unstructured":"Gong, C.-S.A., Yao, K.-W., Shiue, M.-T., Lin, P.-Y., and Huang, C.-N. (2008, January 16\u201318). A Miniaturized PSK Demodulation Device fo Short-Range Wireless Neural Prosthetic Systems. Shanghai, China.","DOI":"10.1109\/ICBBE.2008.720"},{"key":"ref_81","doi-asserted-by":"crossref","unstructured":"Kim, J., Chae, M.S., Wu, L., and Liu, W. (2008, January 20\u201322). A Fully Integrated DPSK Demodulator for High Density Biomedical Implants. Baltimore, USA.","DOI":"10.1109\/BIOCAS.2008.4696882"},{"key":"ref_82","doi-asserted-by":"crossref","unstructured":"Li, C.P., Wu, Z.H., and Li, B. (2010, January 15\u201317). A New Integrated Low-Power BPSK Demodulator for Wireless Implantable Neural Recording System. Hong Kong.","DOI":"10.1109\/EDSSC.2010.5713742"},{"key":"ref_83","doi-asserted-by":"crossref","unstructured":"Sonkusale, S., and Luo, Z. (2007, January 28\u201331). A Wireless Data and Power Telemetry System Using Novel BPSK Demodulator for Non-Destructive Evaluation of Structures. Atlanta, GA, USA.","DOI":"10.1109\/ICSENS.2007.4388396"},{"key":"ref_84","unstructured":"Xu, W., Luo, Z., and Sonkusale, S. (2009, January 3\u20135). Biomedical Implant Transceiver with Novel Multi Level LSK Back Telemetry and Fully Digital BPSK Demodulation. Cambridge, MA, USA."},{"key":"ref_85","doi-asserted-by":"crossref","unstructured":"Elamary, G., Chester, G., and Neasham, J. (2009, January 13\u201316). An Analysis of Wireless Inductive Coupling for High Data Rate Biomedical Telemetry Using a New VHDL n-PSK Modulator. Yasmine Hammamet, Tunisia.","DOI":"10.1109\/ICECS.2009.5410977"},{"key":"ref_86","unstructured":"Elamary, G., Chester, G., and Neasham, J. (2009, January 1\u20133). A Simple Digital VHDL QPSK Modulator Designed Using CPLD\/FPGAs for Biomedical Devices Applications. London, UK."},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"2324","DOI":"10.1587\/transcom.E92.B.2324","article-title":"Phase-Silence-Shift-Keying for Power-Efficient Modulator","volume":"E92-B","author":"Kim","year":"2009","journal-title":"IEICE Trans. Commun"},{"key":"ref_88","unstructured":"Asgarian, F., and Sodagar, A.M. (May, January 29). A High-Data-Rate Low-Power BPSK Demodulator and Clock Recovery Circuit for Implantable Biomedical Devices. Antalya, Turkey."},{"key":"ref_89","doi-asserted-by":"crossref","unstructured":"Asgarian, F., and Sodagar, A.M. (2010, January 3\u20135). A Carrier-Frequency-Independent BPSK Demodulator with 100% Data-Rate-to-Carrier-Frequency Ratio. Paphos, Cyprus.","DOI":"10.1109\/BIOCAS.2010.5709563"},{"key":"ref_90","doi-asserted-by":"crossref","first-page":"2006","DOI":"10.1016\/j.athoracsur.2011.02.068","article-title":"Safety of Magnetic Resonance Imaging in Patients with Implanted Cardiac Prostheses and Metallic Cardiovascular Electronic Devices","volume":"91","author":"Baikoussis","year":"2011","journal-title":"Ann. Thorac Surg"},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1749-8090-5-41","article-title":"Baseline Cerebral Oximetry Values in Cardiac and Vascular Surgery Patients: A Prospective Observational Study","volume":"5","author":"Baikoussis","year":"2010","journal-title":"J. Cardiothorac. Surg"},{"key":"ref_92","unstructured":"He, X. (2004). Fully Integrated Transceiver Design in SOI Process, Ph.D. Thesis,."},{"key":"ref_93","unstructured":"Maymandi-Nejad, M., and Sachdev, M. (December, January 29). A Novel Auto-Zero Technique for a Bio-Implantable Blood Pressure Monitoring Device. London, UK."},{"key":"ref_94","doi-asserted-by":"crossref","unstructured":"Ershadi, M.H., Poudeh, M.B., and Eshtehardiha, S. (2008, January 9\u201311). Fuzzy Logic Controller Based Genetic Algorithm on the Step-Down Converter. Goyang-si, Korea.","DOI":"10.1109\/ICSMA.2008.4505667"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/12\/1\/297\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:58:31Z","timestamp":1760219911000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/12\/1\/297"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,12,28]]},"references-count":94,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2012,1]]}},"alternative-id":["s120100297"],"URL":"https:\/\/doi.org\/10.3390\/s120100297","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,12,28]]}}}