{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T10:07:31Z","timestamp":1777457251557,"version":"3.51.4"},"reference-count":17,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2012,1,11]],"date-time":"2012-01-11T00:00:00Z","timestamp":1326240000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>There is a need for low-cost, high-accuracy measurement of water content in various materials. This study assesses the performance of a new microwave swept frequency domain instrument (SFI) that has promise to provide a low-cost, high-accuracy alternative to the traditional and more expensive time domain reflectometry (TDR). The technique obtains permittivity measurements of soils in the frequency domain utilizing a through transmission configuration, transmissometry, which provides a frequency domain transmissometry measurement (FDT). The measurement is comparable to time domain transmissometry (TDT) with the added advantage of also being able to separately quantify the real and imaginary portions of the complex permittivity so that the measured bulk permittivity is more accurate that the measurement TDR provides where the apparent permittivity is impacted by the signal loss, which can be significant in heavier soils. The experimental SFI was compared with a high-end 12 GHz TDR\/TDT system across a range of soils at varying soil water contents and densities. As propagation delay is the fundamental measurement of interest to the well-established TDR or TDT technique; the first set of tests utilized precision propagation delay lines to test the accuracy of the SFI instrument\u2019s ability to resolve propagation delays across the expected range of delays that a soil probe would present when subjected to the expected range of soil types and soil moisture typical to an agronomic cropping system. The results of the precision-delay line testing suggests the instrument is capable of predicting propagation delays with a RMSE of +\/\u2212105 ps across the range of delays ranging from 0 to 12,000 ps with a coefficient of determination of r2 = 0.998. The second phase of tests noted the rich history of TDR for prediction of soil moisture and leveraged this history by utilizing TDT measured with a high-end Hewlett Packard TDR\/TDT instrument to directly benchmark the SFI instrument over a range of soil types, at varying levels of moisture. This testing protocol was developed to provide the best possible comparison between SFI to TDT than would otherwise be possible by using soil moisture as the bench mark, due to variations in soil density between soil water content levels which are known to impact the calibration between TDR\u2019s estimate of soil water content from the measured propagation delay which is converted to an apparent permittivity measurement. This experimental decision, to compare propagation delay of TDT to FDT, effectively removes the errors due to variations in packing density from the evaluation and provides a direct comparison between the SFI instrument and the time domain technique of TDT. The tests utilized three soils (a sand, an Acuff loam and an Olton clay-loam) that were packed to varying bulk densities and prepared to provide a range of water contents and electrical conductivities by which to compare the performance of the SFI technology to TDT measurements of propagation delay. For each sample tested, the SFI instrument and the TDT both performed the measurements on the exact same probe, thereby both instruments were measuring the exact same soil\/soil-probe response to ensure the most accurate means to compare the SFI instrument to a high-end TDT instrument. Test results provided an estimated instrumental accuracy for the SFI of +\/\u22120.98% of full scale, RMSE basis, for the precision delay lines and +\/\u22121.32% when the SFI was evaluated on loam and clay loam soils, in comparison to TDT as the bench-mark. Results from both experiments provide evidence that the low-cost SFI approach is a viable alternative to conventional TDR\/TDT for high accuracy applications.<\/jats:p>","DOI":"10.3390\/s120100753","type":"journal-article","created":{"date-parts":[[2012,1,11]],"date-time":"2012-01-11T11:57:20Z","timestamp":1326283040000},"page":"753-767","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["Soil Moisture Sensing via Swept Frequency Based Microwave Sensors"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6151-8266","authenticated-orcid":false,"given":"Mathew G.","family":"Pelletier","sequence":"first","affiliation":[{"name":"USDA-ARS, Cotton Production and Processing Unit, Lubbock, TX 79403, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sundar","family":"Karthikeyan","sequence":"additional","affiliation":[{"name":"Rain Bird Corp., San Diego, CA 92123, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Timothy R.","family":"Green","sequence":"additional","affiliation":[{"name":"USDA-ARS, Agricultural Systems Research Unit, Fort Collins, CO 80526, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert C.","family":"Schwartz","sequence":"additional","affiliation":[{"name":"USDA-ARS, Soil and Water Management Research Unit, Bushland, TX 79012, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5086-1947","authenticated-orcid":false,"given":"John D.","family":"Wanjura","sequence":"additional","affiliation":[{"name":"USDA-ARS, Cotton Production and Processing Unit, Lubbock, TX 79403, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6421-118X","authenticated-orcid":false,"given":"Greg A.","family":"Holt","sequence":"additional","affiliation":[{"name":"USDA-ARS, Cotton Production and Processing Unit, Lubbock, TX 79403, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2012,1,11]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"886","DOI":"10.2136\/sssaj2008.0194","article-title":"Complex permittivity model for time domain reflectometry soil water content sensing. I. Theory","volume":"73","author":"Schwartz","year":"2009","journal-title":"Soil Sci. Soc. Am. J"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1568","DOI":"10.2136\/sssaj2004.1568","article-title":"Frequency domain analysis for extending time domain reflectometry water content measurement in highly saline soils","volume":"68","author":"Jones","year":"2004","journal-title":"Soil Sci. Soc. Am. J"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"2592","DOI":"10.3390\/s110302592","article-title":"Analysis of coaxial soil cell in reflection and transmission","volume":"11","author":"Pelletier","year":"2011","journal-title":"Sensors"},{"key":"ref_4","first-page":"135","article-title":"Multi-path interference mitigation for cotton bale microwave moisture sensing","volume":"9","author":"Pelletier","year":"2005","journal-title":"J. Cot. Sci"},{"key":"ref_5","unstructured":"Pelletier, M.G. (2006). Soil Moisture Sensor, US Patent 7,135,871."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"11088","DOI":"10.3390\/s101211088","article-title":"Low-cost electronic microwave calibration for rapid on-line moisture sensing of seedcotton","volume":"10","author":"Pelletier","year":"2010","journal-title":"Sensors"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"8491","DOI":"10.3390\/s100908491","article-title":"Accurate permittivity measurements for microwave imaging via ultra-wideband removal of spurious reflectors","volume":"10","author":"Pelletier","year":"2010","journal-title":"Sensors"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1029\/93WR02948","article-title":"Frequency domain analysis of time domain reflectometry waveforms","volume":"30","author":"Heimovaara","year":"1994","journal-title":"Water Resour. Res"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"3603","DOI":"10.1029\/96WR02695","article-title":"Frequency-dependant dielectric permittivity from 0 to 1 GHz: Time domain reflectometry measurements compared with frequency domain network analyzer measurements","volume":"32","author":"Heimovaara","year":"1996","journal-title":"Water Resour. Res"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1190\/1.1444580","article-title":"Frequency analysis of time-domain reflectometry (TDR) with application to dielectric spectroscopy of soil constituents","volume":"64","author":"Freil","year":"1999","journal-title":"Geophysics"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1063","DOI":"10.2136\/vzj2010.0004","article-title":"A generalized frequency domain reflectometry modeling technique for soil electrical properties determination","volume":"9","author":"Minet","year":"2010","journal-title":"Vadose Zone J"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1088\/0967-3334\/26\/2\/023","article-title":"Solution of the inverse problem of magnetic induction tomography (MIT)","volume":"26","author":"Merwa","year":"2005","journal-title":"Physiol. Meas"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"983","DOI":"10.2136\/sssaj2004.0352","article-title":"Soil dielectric spectra from vector network analyzer data","volume":"69","author":"Logsdon","year":"2005","journal-title":"Soil Sci. Soc. Am. J"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"537","DOI":"10.2136\/sssaj2005.0176N","article-title":"Experimental limitations of time domain reflectometry hardware for dispersive soils","volume":"70","author":"Logsdon","year":"2006","journal-title":"Soil Sci. Soc. Am. J"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"444","DOI":"10.2136\/vzj2003.4440","article-title":"A review of advances in dielectric and electrical conductivity measurement in soils using time domain reflectometry","volume":"2","author":"Robinson","year":"2003","journal-title":"Vadose Zone J"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"757","DOI":"10.3390\/s110100757","article-title":"Fringe capacitance correction for a coaxial soil cell","volume":"11","author":"Pelletier","year":"2011","journal-title":"Sensors"},{"key":"ref_17","unstructured":"Pozar, D.M. (1998). Microwave Engineering, Wiley. [2nd ed]."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/12\/1\/753\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:48:27Z","timestamp":1760219307000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/12\/1\/753"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,1,11]]},"references-count":17,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2012,1]]}},"alternative-id":["s120100753"],"URL":"https:\/\/doi.org\/10.3390\/s120100753","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,1,11]]}}}