{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:34:46Z","timestamp":1760243686129,"version":"build-2065373602"},"reference-count":14,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2012,5,25]],"date-time":"2012-05-25T00:00:00Z","timestamp":1337904000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>We demonstrate an ultrafast displaying Spectral Domain Optical Doppler Tomography system using Graphics Processing Unit (GPU) computing. The calculation of FFT and the Doppler frequency shift is accelerated by the GPU. Our system can display processed OCT and ODT images simultaneously in real time at 120 fps for 1,024 pixels \u00d7 512 lateral A-scans. The computing time for the Doppler information was dependent on the size of the moving average window, but with a window size of 32 pixels the ODT computation time is only 8.3 ms, which is comparable to the data acquisition time. Also the phase noise decreases significantly with the window size. Since the performance of a real-time display for OCT\/ODT is very important for clinical applications that need immediate diagnosis for screening or biopsy. Intraoperative surgery can take much benefit from the real-time display flow rate information from the technology. Moreover, the GPU is an attractive tool for clinical and commercial systems for functional OCT features as well.<\/jats:p>","DOI":"10.3390\/s120606920","type":"journal-article","created":{"date-parts":[[2012,5,25]],"date-time":"2012-05-25T11:15:22Z","timestamp":1337944522000},"page":"6920-6929","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":31,"title":["Ultra-Fast Displaying Spectral Domain Optical Doppler Tomography System Using a Graphics Processing Unit"],"prefix":"10.3390","volume":"12","author":[{"given":"Hyosang","family":"Jeong","sequence":"first","affiliation":[{"name":"School of Electrical Engineering and Computer Science, Kyungpook National University, 1370, Sankyuk-dong, Buk-gu, Daegu 702-701, Korea"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4860-4386","authenticated-orcid":false,"given":"Nam Hyun","family":"Cho","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering and Computer Science, Kyungpook National University, 1370, Sankyuk-dong, Buk-gu, Daegu 702-701, Korea"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2061-2501","authenticated-orcid":false,"given":"Unsang","family":"Jung","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering and Computer Science, Kyungpook National University, 1370, Sankyuk-dong, Buk-gu, Daegu 702-701, Korea"}]},{"given":"Changho","family":"Lee","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering and Computer Science, Kyungpook National University, 1370, Sankyuk-dong, Buk-gu, Daegu 702-701, Korea"}]},{"given":"Jeong-Yeon","family":"Kim","sequence":"additional","affiliation":[{"name":"Division of General Studies, Ulsan National Institute of Science and Technology, Ulsan 689-798, Korea"}]},{"given":"Jeehyun","family":"Kim","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering and Computer Science, Kyungpook National University, 1370, Sankyuk-dong, Buk-gu, Daegu 702-701, Korea"}]}],"member":"1968","published-online":{"date-parts":[[2012,5,25]]},"reference":[{"doi-asserted-by":"crossref","unstructured":"Bouma, B.E., and Tearney, G.J. (2002). Handbook of Optical Coherence Tomography, Marcel Dekker.","key":"ref_1","DOI":"10.1201\/b14024"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"15149","DOI":"10.1364\/OE.16.015149","article-title":"Ultrahigh speed Spectral\/Fourier domain OCT ophthalmic imaging at 70,000 to 312,500 axial scans per second","volume":"16","author":"Potsaid","year":"2008","journal-title":"Opt. Express"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"2919","DOI":"10.1364\/OL.35.002919","article-title":">400 kHz repetition rate wavelength-swept laser and application to high-speed optical frequency domain imaging","volume":"35","author":"Oh","year":"2010","journal-title":"Opt. Lett."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1364\/OL.31.000778","article-title":"Hemoglobin contrast in magnetomotive optical Doppler tomography","volume":"31","author":"Kim","year":"2006","journal-title":"Opt. Lett."},{"doi-asserted-by":"crossref","unstructured":"Watanabe, Y., and Itagaki, T. (2009). Real-time display on Fourier domain optical coherence tomography system using a graphics processing unit. J. Biomed. Opt., 14.","key":"ref_5","DOI":"10.1117\/1.3275463"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"11772","DOI":"10.1364\/OE.18.011772","article-title":"Real-time 4D signal processing and visualization using graphics processing unit on a regular nonlinear-k Fourier-domain OCT system","volume":"18","author":"Zhang","year":"2010","journal-title":"Opt. Express"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"764","DOI":"10.1364\/BOE.2.000764","article-title":"Real-time intraoperative 4D full-range FD-OCT based on the dual graphics processing units architecture for microsurgery guidance","volume":"2","author":"Zhang","year":"2011","journal-title":"Biomed. Opt. Express"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"4756","DOI":"10.1364\/AO.49.004756","article-title":"Real-time processing for full-range fourier-domain optical-coherence tomography with zero-filling interpolation using multiple graphic processing units","volume":"49","author":"Watanabe","year":"2010","journal-title":"Appl. Opt."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1158","DOI":"10.1364\/AO.50.001158","article-title":"Full-range k-domain linearization in spectral-domain optical coherence tomography","volume":"50","author":"Jeon","year":"2011","journal-title":"Appl. Opt."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1627","DOI":"10.1364\/OE.15.001627","article-title":"Doppler optical cardiogram gated 2D color flow imaging at 1,000 fps and 4D in vivo visualization of embryonic heart at 45 fps on a swept source OCT system","volume":"15","author":"Mariampillai","year":"2007","journal-title":"Opt. Express"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/S0030-4018(02)01501-8","article-title":"Improved phase-resolved optical Doppler tomography using the kasai velocity estimator and histogram segmentation","volume":"208","author":"Yang","year":"2002","journal-title":"Opt. Commun."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"794","DOI":"10.1364\/OE.11.000794","article-title":"High speed, wide velocity dynamic range Doppler optical coherence tomography (Part I): System design, signal processing, and performance","volume":"11","author":"Yang","year":"2003","journal-title":"Opt. Express"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1364\/OL.33.000836","article-title":"Quantitative retinal-blood flow measurement with three-dimensional vessel geometry determination using ultrahigh-resolution Doppler optical coherence angiography","volume":"33","author":"Makita","year":"2008","journal-title":"Opt. Lett."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1587","DOI":"10.1364\/OL.32.001587","article-title":"Quantification of a three-dimensional velocity vector using spectral-domain Doppler optical coherence tomography","volume":"32","author":"Ahn","year":"2007","journal-title":"Opt. Lett."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/12\/6\/6920\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:50:28Z","timestamp":1760219428000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/12\/6\/6920"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,5,25]]},"references-count":14,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2012,6]]}},"alternative-id":["s120606920"],"URL":"https:\/\/doi.org\/10.3390\/s120606920","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2012,5,25]]}}}