{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,12]],"date-time":"2026-04-12T02:26:57Z","timestamp":1775960817906,"version":"3.50.1"},"reference-count":254,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2012,8,8]],"date-time":"2012-08-08T00:00:00Z","timestamp":1344384000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Recent advances in microelectronics and biosensors are enabling developments of innovative biochips for advanced healthcare by providing fully integrated platforms for continuous monitoring of a large set of human disease biomarkers. Continuous monitoring of several human metabolites can be addressed by using fully integrated and minimally invasive devices located in the sub-cutis, typically in the peritoneal region. This extends the techniques of continuous monitoring of glucose currently being pursued with diabetic patients. However, several issues have to be considered in order to succeed in developing fully integrated and minimally invasive implantable devices. These innovative devices require a high-degree of integration, minimal invasive surgery, long-term biocompatibility, security and privacy in data transmission, high reliability, high reproducibility, high specificity, low detection limit and high sensitivity. Recent advances in the field have already proposed possible solutions for several of these issues. The aim of the present paper is to present a broad spectrum of recent results and to propose future directions of development in order to obtain fully implantable systems for the continuous monitoring of the human metabolism in advanced healthcare applications.<\/jats:p>","DOI":"10.3390\/s120811013","type":"journal-article","created":{"date-parts":[[2012,8,8]],"date-time":"2012-08-08T12:25:01Z","timestamp":1344428701000},"page":"11013-11060","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":69,"title":["Fully Integrated Biochip Platforms for Advanced Healthcare"],"prefix":"10.3390","volume":"12","author":[{"given":"Sandro","family":"Carrara","sequence":"first","affiliation":[{"name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland"}]},{"given":"Sara","family":"Ghoreishizadeh","sequence":"additional","affiliation":[{"name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland"}]},{"given":"Jacopo","family":"Olivo","sequence":"additional","affiliation":[{"name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland"}]},{"given":"Irene","family":"Taurino","sequence":"additional","affiliation":[{"name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland"}]},{"given":"Camilla","family":"Baj-Rossi","sequence":"additional","affiliation":[{"name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland"}]},{"given":"Andrea","family":"Cavallini","sequence":"additional","affiliation":[{"name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland"}]},{"given":"Maaike","family":"Op de Beeck","sequence":"additional","affiliation":[{"name":"Interuniversity Microelectronics Centre (IMEC), B-3001 Leuven, Belgium"}]},{"given":"Catherine","family":"Dehollain","sequence":"additional","affiliation":[{"name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland"}]},{"given":"Wayne","family":"Burleson","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, University of Massachusetts, Amherst, MA 01003, USA"}]},{"given":"Francis Gabriel","family":"Moussy","sequence":"additional","affiliation":[{"name":"Brunel Institute for Bioengineering, University of Brunel, West London, UB8 3PH, UK"}]},{"given":"Anthony","family":"Guiseppi-Elie","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, Center for Bioelectronics, Biosensors and Biochips, Clemson University, Anderson, SC 29625, USA"},{"name":"ABTECH Scientific, Inc., Richmond, VA 23219, USA"}]},{"given":"Giovanni","family":"De Micheli","sequence":"additional","affiliation":[{"name":"\u00c9cole Polytechnique F\u00e9d\u00e9rale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland"}]}],"member":"1968","published-online":{"date-parts":[[2012,8,8]]},"reference":[{"key":"ref_1","unstructured":"Murg, S., Moore, B., Lovell, M., Wolf, R., Bejjany, B.A., Wu, A.H.B., and Kelles, S. (2009). Business Strategy for Molecular Diagnostics in the Lab, Report Summary, Kennedy Information. [2nd ed.]. Washington G-2 Reports."},{"key":"ref_2","unstructured":"10 Facts on Noncommunicable Diseases. Available online: http:\/\/www.who.int\/features\/factfiles\/noncommunicable_diseases\/en\/index.html (accessed on 18 June 2012)."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1177\/193229681000400517","article-title":"Evaluating the clinical accuracy of GlucoMen\u00aeDay: A novel microdialysis-based continuous glucose monitor","volume":"4","author":"Valgimigli","year":"2010","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2244","DOI":"10.1016\/j.bios.2004.10.031","article-title":"A novel continuous subcutaneous lactate monitoring system","volume":"20","author":"Poscia","year":"2005","journal-title":"Biosen. Bioelectron"},{"key":"ref_5","unstructured":"Carrara, S., Bolomey, L., Boero, C., Cavallini, A., Meurville, E., De Micheli, G., Grassi, F., and Rezzonico, T. (October, January 28\u2013). Single-Metabolite Bio-Nano-Sensors and System for Remote Monitoring in Animal Models. Limerick, Ireland."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1838","DOI":"10.1166\/sl.2011.1731","article-title":"Comparison of Three methods of biocompatible multi-walled carbon nanotubes confinement for the development of implantable amperometric ATP biosensors","volume":"9","author":"Cavallini","year":"2011","journal-title":"Sens. Lett."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"3914","DOI":"10.1016\/j.bios.2011.03.009","article-title":"Multi-panel drugs detection in human serum for personalized therapy","volume":"26","author":"Carrara","year":"2011","journal-title":"Biosen. Bioelectron"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"2275","DOI":"10.1016\/j.bios.2005.11.002","article-title":"A long-term flexible minimally-invasive implantable glucose biosensor based on an epoxy-enhanced polyurethane membrane","volume":"21","author":"Yu","year":"2006","journal-title":"Biosen. Bioelectron"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1126\/scitranslmed.3001148","article-title":"Function of an implanted tissue glucose sensor for more than 1 year in animals","volume":"2","author":"Gough","year":"2010","journal-title":"Sci. Trans. Med."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1016\/j.bios.2008.03.008","article-title":"Screen-printed electrodes based on carbon nanotubes and cytochrome P450scc for highly sensitive cholesterol biosensors","volume":"24","author":"Carrara","year":"2008","journal-title":"Biosen. Bioelectron"},{"key":"ref_11","unstructured":"Carrara, S., Torre, M.D., Cavallini, A., De Venuto, D., and De Micheli, G. (November, January 3\u2013). Multiplexing pH and Temperature in a Molecular Biosensor. Paphos, Cyprus."},{"key":"ref_12","first-page":"1","article-title":"Low power CMOS ramp generator circuit for DC-DC converters","volume":"2","author":"Forghanizadeh","year":"2006","journal-title":"J. Low Power Electron."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1573","DOI":"10.1109\/JSEN.2010.2085042","article-title":"Energy harvesting and remote powering for implantable biosensors","volume":"11","author":"Olivo","year":"2011","journal-title":"IEEE Sens. J."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1400","DOI":"10.3390\/s80314000","article-title":"Electrochemical biosensors\u2014Sensor principles and architectures","volume":"8","author":"Grieshaber","year":"2008","journal-title":"Sensors"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.cccn.2004.01.009","article-title":"Advances in recombinant antibody microarrays","volume":"343","author":"Pavlickova","year":"2004","journal-title":"Clin. Chim. Acta."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1016\/j.snb.2005.07.061","article-title":"A novel hydrogen peroxide sensor based on horseradish peroxidase immobilized in DNA films on a gold electrode","volume":"114","author":"Song","year":"2006","journal-title":"Sens. Actuators B Chem."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.ab.2004.06.039","article-title":"Glucose biosensor prepared by glucose oxidase encapsulated sol-gel and carbon-nanotube-modified basal plane pyrolytic graphite electrode","volume":"333","author":"Compton","year":"2004","journal-title":"Anal. Biochem."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1521","DOI":"10.1016\/j.bios.2003.12.004","article-title":"Comparisons of platinum, gold, palladium and glassy carbon as electrode materials in the design of biosensors for glutamate","volume":"19","author":"Chang","year":"2004","journal-title":"Biosen. Bioelectron"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1016\/S0925-4005(03)00524-0","article-title":"Indium tin oxide (ITO) thin film gas sensor for detection of methanol at room temperature","volume":"96","author":"Patel","year":"2003","journal-title":"Sens. Actuators B Chem."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1108\/13565360410549684","article-title":"Screen-printed sensors with graphite electrodes\u2014Comparison of properties and physical method of sensitivity enhancement","volume":"21","author":"Fujcik","year":"2004","journal-title":"Microelectron. Int."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1016\/j.talanta.2007.03.050","article-title":"Recent developments in the field of screen-printed electrodes and their related applications","volume":"73","author":"Renedo","year":"2007","journal-title":"Talanta"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1016\/j.snb.2005.05.028","article-title":"Gold-based screen-printed sensor for detection of trace lead","volume":"114","author":"Laschi","year":"2006","journal-title":"Sens. Actuators B Chem."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1016\/S0956-5663(01)00312-8","article-title":"Application of conducting polymers to biosensors","volume":"17","author":"Gerard","year":"2002","journal-title":"Biosen. Bioelectron"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Skotheim, T., and Reynolds, J.R. (2007). Handbook of Conducting Polymers: Conjugated Polymer Processing and Applications, Taylor and Francis. [3rd ed.]. Chapter 12.","DOI":"10.1201\/b10739"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1016\/j.trac.2008.05.004","article-title":"Nanomaterial-based electrochemical biosensors for medical applications","volume":"27","author":"Kerman","year":"2008","journal-title":"TrAC Trend. Anal. Chem."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"290","DOI":"10.3390\/s8010290","article-title":"A review on the electrochemical sensors and biosensors composed of nanowires as sensing material","volume":"8","author":"Yogeswaran","year":"2008","journal-title":"Sensors"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.aca.2008.05.070","article-title":"Role of carbon nanotubes in electroanalytical chemistry: A review","volume":"622","year":"2008","journal-title":"Anal. Chim. Acta."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.1016\/j.snb.2006.11.016","article-title":"Electrochemical nanobiosensors","volume":"123","author":"Pumera","year":"2007","journal-title":"Sens. Actuators B Chem."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"526","DOI":"10.3390\/s100100526","article-title":"Nano-bio-technology and sensing chips: New electrochemical systems for detection in personalized therapies and cell biology","volume":"10","author":"Carrara","year":"2010","journal-title":"Sensors"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1007\/s002160051551","article-title":"Electron-transfer mechanisms in amperometric biosensors","volume":"366","author":"Mosbach","year":"2000","journal-title":"Fresenius' J. Anal. Chem."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1088\/0957-4484\/13\/5\/303","article-title":"Direct electron transfer to glucose oxidase using carbon nanotubes","volume":"13","author":"Lei","year":"2002","journal-title":"Nanotechnology"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1002\/elan.200403113","article-title":"Carbon-nanotube based electrochemical biosensors: A review","volume":"17","author":"Wang","year":"2005","journal-title":"Electroanalysis"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1609","DOI":"10.1002\/elan.200290000","article-title":"Electrochemical sensors based on carbon nanotubes","volume":"14","author":"Zhao","year":"2002","journal-title":"Electroanalysis"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1021\/nl0347233","article-title":"Glucose biosensors based on carbon nanotube nanoelectrode ensembles","volume":"4","author":"Lin","year":"2003","journal-title":"Nano Lett."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"3049","DOI":"10.1016\/j.electacta.2004.08.052","article-title":"Nanostructuring electrodes with carbon nanotubes: A review on electrochemistry and applications for sensing","volume":"50","author":"Gooding","year":"2005","journal-title":"Electrochim. Acta."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1007\/s00604-005-0439-z","article-title":"Carbon nanotubes in analytical sciences","volume":"152","year":"2006","journal-title":"Microchim. Acta."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"2289","DOI":"10.3390\/s90402289","article-title":"Electrochemical sensors based on carbon nanotubes","volume":"9","author":"Ahammad","year":"2009","journal-title":"Sensors"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1016\/j.elecom.2009.02.042","article-title":"Direct electrochemistry of glucose oxidase on a graphite nanosheet\u2013Nafion composite film modified electrode","volume":"11","author":"Yang","year":"2009","journal-title":"Electrochem. Commun."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1016\/S0009-2614(02)01326-X","article-title":"Dispersion of single wall carbon nanotubes by in situ polymerization under sonication","volume":"364","author":"Park","year":"2002","journal-title":"Chem. Phys. Lett."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.snb.2009.08.012","article-title":"Application of functionalised carbon nanotubes immobilised into chitosan films in amperometric enzyme biosensors","volume":"142","author":"Ghica","year":"2009","journal-title":"Sens. Actuators B Chem."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1405","DOI":"10.1016\/j.bios.2005.07.012","article-title":"Enzyme inhibition-based biosensors for food safety and environmental monitoring","volume":"21","author":"Mohammadi","year":"2006","journal-title":"Biosens. Bioelectron"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"899","DOI":"10.1002\/1521-4095(20020618)14:12<899::AID-ADMA899>3.0.CO;2-2","article-title":"Self-assembly of carbon nanotubes","volume":"14","author":"Shimoda","year":"2002","journal-title":"Adv. Mater."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/j.bios.2004.10.008","article-title":"Direct electron transfer between cytochrome P450scc and screen-printed rhodium graphite electrode modified with gold nanoparticles","volume":"21","author":"Shumyantseva","year":"2005","journal-title":"Biosens. Bioelectron"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.snb.2004.12.053","article-title":"Improved nanocomposite materials for biosensor applications investigated by Impedance Spectroscopy","volume":"109","author":"Carrara","year":"2005","journal-title":"Sens. Actuators B Chem."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"2679","DOI":"10.1039\/b700857k","article-title":"Decorating carbon nanotubes with metal or semiconductor nanoparticles","volume":"17","author":"Georgakilas","year":"2007","journal-title":"J. Mater. Chem."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1002\/smll.200500324","article-title":"Metal nanoparticles and related materials supported on carbon nanotubes: Methods and applications","volume":"2","author":"Wildgoose","year":"2006","journal-title":"Small"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1016\/j.bios.2005.04.009","article-title":"Platinum nanoparticles-doped sol\u2013gel\/carbon nanotubes composite electrochemical sensors and biosensors","volume":"21","author":"Yang","year":"2006","journal-title":"Biosens. Bioelectron"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1016\/j.elecom.2008.11.048","article-title":"Synergistic contributions of multiwall carbon nanotubes and gold nanoparticles in a chitosan\u2013ionic liquid matrix towards improved performance for a glucose sensor","volume":"11","author":"Gopalan","year":"2009","journal-title":"Electrochem. Commun."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"2334","DOI":"10.1088\/0957-4484\/17\/9\/043","article-title":"Pt-Pb alloy nanoparticle\/carbon nanotube nanocomposite: A strong electrocatalyst for glucose oxidation","volume":"17","author":"Cui","year":"2006","journal-title":"Nanotechnology"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"5873","DOI":"10.1016\/j.electacta.2007.03.020","article-title":"A new route for the electrodeposition of platinum-nickel alloy nanoparticles on multi-walled carbon nanotubes","volume":"52","author":"Zhao","year":"2007","journal-title":"Electrochim. Acta."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1537","DOI":"10.1002\/adfm.200600416","article-title":"Platinum nanoparticle clusters immobilized on multiwalled carbon nanotubes: Electrodeposition and enhanced electrocatalytic activity for methanol oxidation","volume":"17","author":"Zhao","year":"2007","journal-title":"Adv. Funct. Mater."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"2891","DOI":"10.1088\/0957-4484\/17\/12\/011","article-title":"Controlled decoration of carbon nanotubes with nanoparticles","volume":"17","author":"Lu","year":"2006","journal-title":"Nanotechnology"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"2727","DOI":"10.1021\/nl101723g","article-title":"Design and synthesis of hierarchical MnO2 nanospheres\/carbon nanotubes\/conducting polymer ternary composite for high performance electrochemical electrodes","volume":"10","author":"Hou","year":"2010","journal-title":"Nano Lett."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1166\/jnn.2006.903","article-title":"Nanocomposites based on conducting polymers and carbon nanotubes: From fancy materials to functional applications","volume":"6","author":"Baibarac","year":"2006","journal-title":"J. Nanosci. Nanotechnol."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1016\/j.synthmet.2008.11.030","article-title":"Conducting polymer functionalized multi-walled carbon nanotubes with noble metal nanoparticles: Synthesis, morphological characteristics and electrical properties","volume":"159","author":"Reddy","year":"2009","journal-title":"Synth. Met."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.aca.2008.02.068","article-title":"Conducting polymers in chemical sensors and arrays","volume":"614","author":"Lange","year":"2008","journal-title":"Anal. Chim. Acta."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.aca.2006.04.055","article-title":"Prospects of conducting polymers in biosensors","volume":"578","author":"Malhotra","year":"2006","journal-title":"Anal. Chim. Acta."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1007\/s00216-003-2131-7","article-title":"Biosensors based on electropolymerized films: New trends","volume":"377","author":"Cosnier","year":"2003","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"2701","DOI":"10.1016\/j.biomaterials.2009.12.052","article-title":"Electroconductive hydrogels: Synthesis, characterization and biomedical applications","volume":"31","year":"2010","journal-title":"Biomaterials"},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"3120","DOI":"10.1016\/j.bios.2007.02.001","article-title":"Overoxidized polypyrrole film directed single-walled carbon nanotubes immobilization on glassy carbon electrode and its sensing applications","volume":"22","author":"Li","year":"2007","journal-title":"Biosens. Bioelectron"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"3083","DOI":"10.1021\/am100591t","article-title":"Glucose biosensor from covalent immobilization of chitosan-coupled carbon nanotubes on polyaniline-modified gold electrode","volume":"2","author":"Yuan","year":"2010","journal-title":"ACS Appl. Mater. Interface"},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"3051","DOI":"10.1016\/j.bios.2007.01.005","article-title":"Amperometric ethanol biosensor based on poly(vinyl alcohol)\u2013multiwalled carbon nanotube-alcohol dehydrogenase biocomposite","volume":"22","author":"Tsai","year":"2007","journal-title":"Biosens. Bioelectron"},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.jelechem.2006.02.014","article-title":"\u03b2-Cyclodextrin incorporated carbon nanotubes-modified electrodes for simultaneous determination of adenine and guanine","volume":"589","author":"Wang","year":"2006","journal-title":"J. Electroanal. Chem."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1016\/j.snb.2008.06.037","article-title":"Single-walled carbon nanotube-ionic liquid paste electrode for the sensitive voltammetric determination of folic acid","volume":"134","author":"Xiao","year":"2008","journal-title":"Sens. Actuators B Chem."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.ab.2004.10.040","article-title":"An amperometric cholesterol biosensor based on multiwalled carbon nanotubes and organically modified sol-gel\/chitosan hybrid composite film","volume":"337","author":"Tan","year":"2005","journal-title":"Anal. Biochem."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1016\/j.talanta.2007.07.019","article-title":"Glucose biosensors based on platinum nanoparticles-deposited carbon nanotubes in sol\u2013gel chitosan\/silica hybrid","volume":"74","author":"Kang","year":"2008","journal-title":"Talanta"},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1016\/j.snb.2007.02.012","article-title":"Sol\u2013gel derived carbon nanotubes ceramic composite electrodes for electrochemical sensing","volume":"125","author":"Zhu","year":"2007","journal-title":"Sens. Actuators B Chem."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"5796","DOI":"10.1002\/anie.200600317","article-title":"Color-saturated green-emitting QD-LEDs","volume":"45","author":"Steckel","year":"2006","journal-title":"Angew. Chem. Int. Edn."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.aca.2010.05.026","article-title":"Beyond labels: A review of the application of quantum dots as integrated components of assays, bioprobes, and biosensors utilizing optical transduction","volume":"673","author":"Algar","year":"2010","journal-title":"Anal. Chim. Acta."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"5796","DOI":"10.1002\/anie.200301703","article-title":"Functional hybrid devices of proteins and inorganic nanoparticles","volume":"42","author":"Niemeyer","year":"2003","journal-title":"Angew. Chem. Int. Edn."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"2455","DOI":"10.1002\/1099-0682(200109)2001:10<2455::AID-EJIC2455>3.0.CO;2-Z","article-title":"Nanoscopic metal particles\u2014Synthetic methods and potential applications","volume":"2001","author":"Richards","year":"2001","journal-title":"Eur. J. Inorg. Chem."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"2965","DOI":"10.1016\/S1452-3981(23)18232-0","article-title":"Strategies of nano-manipulation for application in electrochemical biosensors","volume":"6","author":"Iost","year":"2011","journal-title":"Int. J. Electrochem. Sci."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"10644","DOI":"10.1021\/la0513712","article-title":"Biocompatibility of gold nanoparticles and their endocytotic fate inside the cellular compartment: A microscopic overview","volume":"21","author":"Shukla","year":"2005","journal-title":"Langmuir"},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1002\/elan.200503449","article-title":"Nanowire-based electrochemical biosensors","volume":"18","author":"Wanekaya","year":"2006","journal-title":"Electroanalysis"},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1038\/nmat1403","article-title":"Mechanical properties of ultrahigh-strength gold nanowires","volume":"4","author":"Heidelberg","year":"2005","journal-title":"Nat. Mater."},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"2085","DOI":"10.1002\/ange.200704707","article-title":"Synthesis of ultrathin palladium and platinum nanowires and a study of their magnetic properties","volume":"120","author":"Teng","year":"2008","journal-title":"Angew. Chem."},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"16025","DOI":"10.1021\/ja037280d","article-title":"Systematic synthesis and characterization of single-crystal lanthanide orthophosphate nanowires","volume":"125","author":"Fang","year":"2003","journal-title":"J. Am. Chem. Soc."},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/j.bios.2008.04.014","article-title":"Towards development of chemosensors and biosensors with metal-oxide-based nanowires or nanotubes","volume":"24","author":"Aihua","year":"2008","journal-title":"Biosens. Bioelectron"},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"2681","DOI":"10.1002\/adma.200803754","article-title":"Silicon nanowires: A review on aspects of their growth and their electrical properties","volume":"21","author":"Schmidt","year":"2009","journal-title":"Adv. Mater."},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"1027","DOI":"10.1002\/elan.200900571","article-title":"Graphene based electrochemical sensors And biosensors: A review","volume":"22","author":"Shao","year":"2010","journal-title":"Electroanalysis"},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"5603","DOI":"10.1021\/ac900136z","article-title":"Electrochemical sensing and biosensing platform based on chemically reduced graphene oxide","volume":"81","author":"Zhou","year":"2009","journal-title":"Anal. Chem."},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"1504","DOI":"10.1016\/j.bios.2009.11.009","article-title":"Electrochemical determination of NADH and ethanol based on ionic liquid-functionalized graphene","volume":"25","author":"Shan","year":"2010","journal-title":"Biosens. Bioelectron"},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1016\/j.bios.2009.09.024","article-title":"Graphene\/AuNPs\/chitosan nanocomposites film for glucose biosensing","volume":"25","author":"Shan","year":"2010","journal-title":"Biosens. Bioelectron"},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"14071","DOI":"10.1021\/jp906348x","article-title":"Direct electrochemical reduction of single-layer graphene oxide and subsequent functionalization with glucose oxidase","volume":"113","author":"Wang","year":"2009","journal-title":"J. Phys. Chem. C."},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/S0956-5663(02)00183-5","article-title":"Novel carbon materials in biosensor systems","volume":"18","author":"Sotiropoulou","year":"2003","journal-title":"Biosens. Bioelectron"},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1016\/S1388-2481(03)00168-1","article-title":"Carbon nanotubes paste electrode","volume":"5","author":"Rubianes","year":"2003","journal-title":"Electrochem. Commun."},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1016\/j.bios.2007.06.009","article-title":"Amperometric glucose sensor based on catalytic reduction of dissolved oxygen at soluble carbon nanofiber","volume":"23","author":"Wu","year":"2007","journal-title":"Biosens. Bioelectron"},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"6240","DOI":"10.1021\/cm702133u","article-title":"Simple fabrication of a highly sensitive glucose biosensor using enzymes immobilized in exfoliated graphite nanoplatelets nafion membrane","volume":"19","author":"Lu","year":"2007","journal-title":"Chem. Mater."},{"key":"ref_89","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1016\/j.bios.2008.04.025","article-title":"Highly ordered mesoporous carbons as electrode material for the construction of electrochemical dehydrogenase- and oxidase-based biosensors","volume":"24","author":"Zhou","year":"2008","journal-title":"Biosens. Bioelectron"},{"key":"ref_90","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/j.snb.2008.09.014","article-title":"Recent progress in the development of nano-structured conducting polymers\/nanocomposites for sensor applications","volume":"136","author":"Ahuja","year":"2009","journal-title":"Sens. Actuators B Chem."},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"5218","DOI":"10.1021\/jp067213g","article-title":"Field-effect transistors based on single nanowires of conducting polymers","volume":"111","author":"Wanekaya","year":"2007","journal-title":"J. Phys. Chem. C."},{"key":"ref_92","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1126\/science.1130557","article-title":"Nanoparticle polymer composites: Where two small worlds meet","volume":"314","author":"Balazs","year":"2006","journal-title":"Science"},{"key":"ref_93","doi-asserted-by":"crossref","unstructured":"Zourob, M. (2010). Enzyme for Biosensing Applications Recognition Receptors in Biosensors, Springer.","DOI":"10.1007\/978-1-4419-0919-0"},{"key":"ref_94","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1080\/02652030500070176","article-title":"DNA arrays, electronic noses and tongues, biosensors and receptors for rapid detection of toxigenic fungi and mycotoxins: A review","volume":"22","author":"Logrieco","year":"2005","journal-title":"Food Addit. Contam."},{"key":"ref_95","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.aca.2007.10.046","article-title":"A review on novel developments and applications of immunosensors in food analysis","volume":"605","author":"Ricci","year":"2007","journal-title":"Anal. Chim. Acta."},{"key":"ref_96","doi-asserted-by":"crossref","first-page":"870","DOI":"10.1002\/elan.200603790","article-title":"Polymeric acid doped polyaniline nanotubes for oligonucleotide sensors","volume":"19","author":"Zhang","year":"2007","journal-title":"Electroanalysis"},{"key":"ref_97","doi-asserted-by":"crossref","first-page":"1883","DOI":"10.1021\/ac7018014","article-title":"Aptamer-based electrochemical sensors with aptamer\u2013complementary DNA oligonucleotides as probe","volume":"80","author":"Lu","year":"2008","journal-title":"Anal. Chem."},{"key":"ref_98","doi-asserted-by":"crossref","first-page":"739","DOI":"10.3390\/s8020739","article-title":"Electroanalysis of NADH using conducting and redox active polymer\/carbon nanotubes modified electrodes-a review","volume":"8","author":"Kumar","year":"2008","journal-title":"Sensors"},{"key":"ref_99","doi-asserted-by":"crossref","first-page":"2003","DOI":"10.1016\/j.bios.2006.08.047","article-title":"Investigation of biotin\u2013streptavidin binding interactions using microcantilever sensors","volume":"22","author":"Shu","year":"2007","journal-title":"Biosens. Bioelectron"},{"key":"ref_100","doi-asserted-by":"crossref","first-page":"1180","DOI":"10.1002\/(SICI)1521-3773(20000403)39:7<1180::AID-ANIE1180>3.0.CO;2-E","article-title":"Integration of layered redox proteins and conductive supports for bioelectronic applications","volume":"39","author":"Katz","year":"2000","journal-title":"Angew. Chem. Int. Edn."},{"key":"ref_101","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1002\/elan.1140091302","article-title":"Electrical contact of redox enzyme layers associated with electrodes: Routes to amperometric biosensors","volume":"9","author":"Katz","year":"1997","journal-title":"Electroanalysis"},{"key":"ref_102","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1111\/j.1464-5491.2008.02642.x","article-title":"Glucose sensors: A review of current and emerging technology","volume":"26","author":"Oliver","year":"2009","journal-title":"Diabet. Med."},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1038\/nbt0602-619","article-title":"[beta]-Lactamase protein fragment complementation assays as in vivo and in vitro sensors of protein-protein interactions","volume":"20","author":"Galarneau","year":"2002","journal-title":"Nat. Biotechnol."},{"key":"ref_104","doi-asserted-by":"crossref","first-page":"1641","DOI":"10.1016\/j.bios.2003.12.035","article-title":"Urea potentiometric biosensor based on modified electrodes with urease immobilized on polyethylenimine films","volume":"19","author":"Herlem","year":"2004","journal-title":"Biosens. Bioelectron"},{"key":"ref_105","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1016\/S0731-7085(98)00056-9","article-title":"Amperometric biosensors for clinical and therapeutic drug monitoring: A review","volume":"19","author":"Wang","year":"1999","journal-title":"J. Pharm. Biomed. Anal."},{"key":"ref_106","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1038\/nrd792","article-title":"Cytochrome P450 enzymes in the generation of commercial products","volume":"1","author":"Guengerich","year":"2002","journal-title":"Nat. Rev. Drug Discov."},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1021\/tx700079z","article-title":"Cytochrome p450 and chemical toxicology","volume":"21","author":"Guengerich","year":"2008","journal-title":"Chem. Res. Toxicol."},{"key":"ref_108","doi-asserted-by":"crossref","first-page":"1533","DOI":"10.1016\/j.bcp.2005.02.020","article-title":"Electrochemical characterisation of the human cytochrome P450 CYP2C9","volume":"69","author":"Johnson","year":"2005","journal-title":"Biochem. Pharmacol."},{"key":"ref_109","doi-asserted-by":"crossref","first-page":"2408","DOI":"10.1016\/j.bios.2004.11.023","article-title":"Cytochrome P450 biosensors\u2014A review","volume":"20","author":"Bistolas","year":"2005","journal-title":"Biosens. Bioelectron"},{"key":"ref_110","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S1567-1739(02)00219-5","article-title":"Biomolecules for development of biosensors and their applications","volume":"3","author":"Sharma","year":"2003","journal-title":"Curr. Appl. Phys."},{"key":"ref_111","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1016\/j.biomaterials.2006.09.046","article-title":"Biomolecular immobilization on conducting polymers for biosensing applications","volume":"28","author":"Ahuja","year":"2007","journal-title":"Biomaterials"},{"key":"ref_112","doi-asserted-by":"crossref","first-page":"1775","DOI":"10.1021\/bm061197b","article-title":"Protein immobilization strategies for protein biochips","volume":"8","author":"Rusmini","year":"2007","journal-title":"Biomacromolecules"},{"key":"ref_113","doi-asserted-by":"crossref","first-page":"1817","DOI":"10.1016\/S0006-2952(03)00186-2","article-title":"An amperometric biosensor with human CYP3A4 as a novel drug screening tool","volume":"65","author":"Joseph","year":"2003","journal-title":"Biochem. Pharmacol."},{"key":"ref_114","doi-asserted-by":"crossref","first-page":"899","DOI":"10.1016\/j.elecom.2006.03.028","article-title":"Dispersion of single walled carbon nanotubes. Comparison of different dispersing strategies for preparation of modified electrodes toward hydrogen peroxide detection","volume":"8","author":"Tkac","year":"2006","journal-title":"Electrochem. Commun."},{"key":"ref_115","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.ab.2007.07.005","article-title":"A novel glucose biosensor based on immobilization of glucose oxidase in chitosan on a glassy carbon electrode modified with gold\u2013platinum alloy nanoparticles\/multiwall carbon nanotubes","volume":"369","author":"Kang","year":"2007","journal-title":"Anal. Biochem."},{"key":"ref_116","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1016\/j.talanta.2005.05.030","article-title":"Composite film of carbon nanotubes and chitosan for preparation of amperometric hydrogen peroxide biosensor","volume":"68","author":"Qian","year":"2006","journal-title":"Talanta"},{"key":"ref_117","doi-asserted-by":"crossref","first-page":"2881","DOI":"10.1021\/bm050410l","article-title":"Biofabrication with chitosan","volume":"6","author":"Yi","year":"2005","journal-title":"Biomacromolecules"},{"key":"ref_118","doi-asserted-by":"crossref","first-page":"768","DOI":"10.1016\/j.snb.2009.01.033","article-title":"One-step synthesis of silver nanoparticles\/carbon nanotubes\/chitosan film and its application in glucose biosensor","volume":"137","author":"He","year":"2009","journal-title":"Sens. Actuators B Chem."},{"key":"ref_119","doi-asserted-by":"crossref","first-page":"11276","DOI":"10.1021\/jp073884i","article-title":"Electrodeposition of carbon nanotubes-chitosan-glucose oxidase biosensing composite films triggered by reduction of p-benzoquinone or H2O2","volume":"111","author":"Zhou","year":"2007","journal-title":"J. Phys. Chem. B."},{"key":"ref_120","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1016\/j.ab.2004.07.005","article-title":"A glucose biosensor based on chitosan\u2013glucose oxidase\u2013gold nanoparticles biocomposite formed by one-step electrodeposition","volume":"334","author":"Luo","year":"2004","journal-title":"Anal. Biochem."},{"key":"ref_121","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.snb.2007.01.032","article-title":"Amperometric biosensors based on multiwalled carbon nanotube-Nafion-tyrosinase nanobiocomposites for the determination of phenolic compounds","volume":"125","author":"Tsai","year":"2007","journal-title":"Sens. Actuators B Chem."},{"key":"ref_122","doi-asserted-by":"crossref","first-page":"2408","DOI":"10.1021\/ja028951v","article-title":"Solubilization of carbon nanotubes by nafion toward the preparation of amperometric biosensors","volume":"125","author":"Musameh","year":"2003","journal-title":"J. Am. Chem. Soc."},{"key":"ref_123","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.colsurfb.2008.02.003","article-title":"Electrochemical behavior and voltammetric determination of norfloxacin at glassy carbon electrode modified with multi walled carbon nanotubes\/Nafion","volume":"64","author":"Huang","year":"2008","journal-title":"Colloids Surf. B Biointerfaces"},{"key":"ref_124","doi-asserted-by":"crossref","first-page":"1571","DOI":"10.1081\/AL-120037588","article-title":"Affinity methods to immobilize acetylcholinesterases for manufacturing biosensors","volume":"37","author":"Andreescu","year":"2004","journal-title":"Anal. Lett."},{"key":"ref_125","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/S0956-5663(01)00313-X","article-title":"Mediated biosensors","volume":"17","author":"Chaubey","year":"2002","journal-title":"Biosens. Bioelectron"},{"key":"ref_126","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1385\/ABAB:96:1-3:249","article-title":"Coimmobilization of urease and glutamate dehydrogenase in electrochemically prepared polypyrrole-polyvinyl sulfonate films","volume":"96","author":"Gambhir","year":"2001","journal-title":"Appl. Biochem. Biotechnol."},{"key":"ref_127","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.aca.2005.10.011","article-title":"Biosensing and drug delivery by polypyrrole","volume":"568","author":"Geetha","year":"2006","journal-title":"Anal. Chim. Acta."},{"key":"ref_128","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1007\/s00604-003-0067-4","article-title":"Recent advances in electropolymerized conducting polymers in amperometric biosensors","volume":"143","author":"Vidal","year":"2003","journal-title":"Microchim. Acta."},{"key":"ref_129","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1016\/j.bios.2005.04.008","article-title":"The biosensor based on the pyruvate oxidase modified conducting polymer for phosphate ions determinations","volume":"21","author":"Rahman","year":"2006","journal-title":"Biosens. Bioelectron"},{"key":"ref_130","doi-asserted-by":"crossref","first-page":"899","DOI":"10.1016\/j.trac.2006.04.008","article-title":"Electrochemical biosensors based on advanced bioimmobilization matrices","volume":"25","author":"Xu","year":"2006","journal-title":"TrAC Trends Anal. Chem."},{"key":"ref_131","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.talanta.2005.04.042","article-title":"High stability amperometric biosensor based on enzyme entrapment in microgels","volume":"68","year":"2005","journal-title":"Talanta"},{"key":"ref_132","doi-asserted-by":"crossref","first-page":"4381","DOI":"10.3390\/s100504381","article-title":"Responsive hydrogels for label-free signal transduction within biosensors","volume":"10","author":"Barriet","year":"2010","journal-title":"Sensors"},{"key":"ref_133","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/S1369-7021(07)70049-4","article-title":"Bioresponsive hydrogels","volume":"10","author":"Ulijn","year":"2007","journal-title":"Mater. Today"},{"key":"ref_134","doi-asserted-by":"crossref","first-page":"2387","DOI":"10.1016\/j.bios.2006.12.025","article-title":"Entrapment of biomolecules in sol\u2013gel matrix for applications in biosensors: Problems and future prospects","volume":"22","author":"Gupta","year":"2007","journal-title":"Biosens. Bioelectron"},{"key":"ref_135","doi-asserted-by":"crossref","first-page":"1477","DOI":"10.2116\/analsci.19.1477","article-title":"Application of polyaniline\/sol-gel derived tetraethylorthosilicate films to an amperometric lactate biosensor","volume":"19","author":"Chaubey","year":"2003","journal-title":"Anal. Sci."},{"key":"ref_136","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.aca.2005.12.060","article-title":"Biosensors based on highly sensitive acetylcholinesterases for enhanced carbamate insecticides detection","volume":"562","author":"Fournier","year":"2006","journal-title":"Anal. Chim. Acta."},{"key":"ref_137","doi-asserted-by":"crossref","first-page":"3213","DOI":"10.1529\/biophysj.104.046169","article-title":"The protein-tethered lipid bilayer: A novel mimic of the biological membrane","volume":"87","author":"Giess","year":"2004","journal-title":"Biophys. J."},{"key":"ref_138","doi-asserted-by":"crossref","first-page":"1711","DOI":"10.1021\/ja056972u","article-title":"Redox enzymes in tethered membranes","volume":"128","author":"Jeuken","year":"2006","journal-title":"J. Am. Chem. Soc."},{"key":"ref_139","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1002\/elan.200403001","article-title":"Membrane electrodes for protein and enzyme electrochemistry","volume":"16","author":"Lojou","year":"2004","journal-title":"Electroanalysis"},{"key":"ref_140","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1007\/s00216-009-3274-y","article-title":"Biosensing applications of clay-modified electrodes: A review","volume":"396","author":"Mousty","year":"2010","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_141","doi-asserted-by":"crossref","first-page":"18827","DOI":"10.1021\/jp907235n","article-title":"Supramolecular architecture in langmuir films of a luminescent ionic liquid crystal","volume":"113","author":"Cea","year":"2009","journal-title":"J. Phys. Chem. C."},{"key":"ref_142","doi-asserted-by":"crossref","first-page":"5869","DOI":"10.1021\/la9038107","article-title":"Mixing alternating copolymers containing fluorenyl groups with phospholipids to obtain langmuir and langmuir\u2013blodgett films","volume":"26","author":"Santos","year":"2009","journal-title":"Langmuir"},{"key":"ref_143","doi-asserted-by":"crossref","first-page":"14064","DOI":"10.1021\/la102616h","article-title":"Effect of surface charge distribution on the adsorption orientation of proteins to lipid monolayers","volume":"26","author":"Tiemeyer","year":"2010","journal-title":"Langmuir"},{"key":"ref_144","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.colsurfb.2010.01.017","article-title":"Properties of lipophilic nucleoside monolayers at the air\u2013water interface","volume":"77","author":"Montanha","year":"2010","journal-title":"Colloids Surf B Biointerfaces"},{"key":"ref_145","doi-asserted-by":"crossref","first-page":"10051","DOI":"10.1021\/la901019p","article-title":"Cholesterol mediates chitosan activity on phospholipid Monolayers and langmuir\u2013blodgett films","volume":"25","author":"Pavinatto","year":"2009","journal-title":"Langmuir"},{"key":"ref_146","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/j.cis.2005.04.006","article-title":"Enzyme association with lipidic Langmuir\u2013Blodgett films: Interests and applications in nanobioscience","volume":"116","author":"Godoy","year":"2005","journal-title":"Adv. Colloid Interface Sci."},{"key":"ref_147","doi-asserted-by":"crossref","first-page":"2291","DOI":"10.1016\/j.bbamem.2008.05.012","article-title":"Enhanced activity of horseradish peroxidase in Langmuir\u2013Blodgett films of phospholipids","volume":"1778","author":"Schmidt","year":"2008","journal-title":"Biochim. Biophys. Acta (BBA) Biomembr"},{"key":"ref_148","first-page":"125","article-title":"A novel amperometric hydrogen peroxide biosensor based on immobilization of hemoglobin in linoleic acid monolayer by Langmuir\u2013Blodgett technique","volume":"284\u2013285","author":"Kafi","year":"2006","journal-title":"Colloids Surf. A Physicochem. Eng. Asp."},{"key":"ref_149","doi-asserted-by":"crossref","first-page":"4675","DOI":"10.1021\/la063175g","article-title":"Incorporation of glucose oxidase into langmuir-blodgett films based on prussian blue applied to amperometric glucose biosensor","volume":"23","author":"Saiki","year":"2007","journal-title":"Langmuir"},{"key":"ref_150","doi-asserted-by":"crossref","first-page":"937","DOI":"10.1016\/S0956-5663(01)00213-5","article-title":"Optical organophosphorus biosensor consisting of acetylcholinesterase\/viologen hetero Langmuir-Blodgett film","volume":"16","author":"Choi","year":"2001","journal-title":"Biosens. Bioelectron"},{"key":"ref_151","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1016\/S0956-5663(02)00020-9","article-title":"Immobilization of urease on poly(N-vinyl carbazole)\/stearic acid Langmuir\u2013Blodgett films for application to urea biosensor","volume":"17","author":"Singhal","year":"2002","journal-title":"Biosens. Bioelectron"},{"key":"ref_152","doi-asserted-by":"crossref","first-page":"4995","DOI":"10.1039\/c0jm03864d","article-title":"Optimized architecture for Tyrosinase-containing Langmuir-Blodgett films to detect pyrogallol","volume":"21","author":"Pavinatto","year":"2011","journal-title":"J. Mater. Chem."},{"key":"ref_153","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/S0302-4598(98)00105-6","article-title":"Direct bioelectrochemical monitoring of choline oxidase kinetic behaviour in Langmuir\u2013Blodgett nanostructures","volume":"46","author":"Coulet","year":"1998","journal-title":"Bioelectrochem. Bioenerg"},{"key":"ref_154","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1016\/j.bios.2004.03.020","article-title":"Lactose biosensor based on Langmuir\u2013Blodgett films of poly(3-hexyl thiophene)","volume":"20","author":"Sharma","year":"2004","journal-title":"Biosens. Bioelectron"},{"key":"ref_155","doi-asserted-by":"crossref","first-page":"1507","DOI":"10.1080\/00032710903502074","article-title":"A uric acid biosensor based on Langmuir-Blodgett film as an enzyme-immobilizing matrix","volume":"43","author":"Wang","year":"2010","journal-title":"Anal. Lett."},{"key":"ref_156","doi-asserted-by":"crossref","first-page":"1254","DOI":"10.1016\/j.bios.2009.09.043","article-title":"Immobilization of biomolecules on nanostructured films for biosensing","volume":"25","author":"Siqueira","year":"2010","journal-title":"Biosens. Bioelectron"},{"key":"ref_157","doi-asserted-by":"crossref","first-page":"1737","DOI":"10.1002\/elan.200603630","article-title":"Electrochemical biosensors based on layer-by-layer assemblies","volume":"18","author":"Zhao","year":"2006","journal-title":"Electroanalysis"},{"key":"ref_158","doi-asserted-by":"crossref","first-page":"2551","DOI":"10.1081\/AL-120024632","article-title":"Layer-by-layer biomolecular assemblies for enzyme sensors, immunosensing, and nanoarchitectures","volume":"36","year":"2003","journal-title":"Anal. Lett."},{"key":"ref_159","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.elecom.2007.10.030","article-title":"Direct electron transfer of cytochrome c and its biosensor based on gold nanoparticles\/room temperature ionic liquid\/carbon nanotubes composite film","volume":"10","author":"Zou","year":"2008","journal-title":"Electrochem. Commun."},{"key":"ref_160","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/S0003-2670(00)00953-3","article-title":"Fabrication of multilayer films containing horseradish peroxidase and polycation-bearing Os complex by means of electrostatic layer-by-layer adsorption and its application as a hydrogen peroxide sensor","volume":"418","author":"Li","year":"2000","journal-title":"Anal. Chim. Acta."},{"key":"ref_161","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1016\/S0956-5663(01)00208-1","article-title":"Cholesterol biosensors prepared by layer-by-layer technique","volume":"16","author":"Ram","year":"2001","journal-title":"Biosens. Bioelectron"},{"key":"ref_162","doi-asserted-by":"crossref","first-page":"2567","DOI":"10.1039\/c0cs00056f","article-title":"Immobilization of bio-macromolecules on self-assembled monolayers: Methods and sensor applications","volume":"40","author":"Samanta","year":"2011","journal-title":"Chem. Soc. Rev."},{"key":"ref_163","doi-asserted-by":"crossref","first-page":"892","DOI":"10.1124\/dmd.108.025452","article-title":"Electrocatalytic drug metabolism by CYP2C9 bonded to a self-assembled monolayer-modified electrode","volume":"37","author":"Yang","year":"2009","journal-title":"Drug Metab. Dispos."},{"key":"ref_164","doi-asserted-by":"crossref","unstructured":"De Micheli, G., Ghoreishizadeh, S.S., Boero, C., Valgimigli, F., and Carrara, S. (2011, January 14\u201318). An Integrated Platform for Advanced Diagnostics. Grenoble, France.","DOI":"10.1109\/DATE.2011.5763235"},{"key":"ref_165","doi-asserted-by":"crossref","first-page":"6484","DOI":"10.1021\/jp990957s","article-title":"Large scale CVD synthesis of single-walled carbon nanotubes","volume":"103","author":"Cassell","year":"1999","journal-title":"J. Phys. Chem. B."},{"key":"ref_166","doi-asserted-by":"crossref","unstructured":"Nessim, G.D., Acquaviva, D., Seita, M., O'Brien, K.P., and Thompson, C.V. (2010). Adv. Funct. Mater., 20, 1306\u20131312.","DOI":"10.1002\/adfm.200902265"},{"key":"ref_167","doi-asserted-by":"crossref","first-page":"12617","DOI":"10.1021\/jp0730848","article-title":"Synthesis of aligned carbon nanotubes on double-sided metallic substrate by chemical vapor deposition","volume":"111","author":"Wang","year":"2007","journal-title":"J. Phys. Chem. C."},{"key":"ref_168","doi-asserted-by":"crossref","first-page":"4359","DOI":"10.1021\/jp102986f","article-title":"Support-catalyst-gas interactions during carbon nanotube growth on metallic Ta films","volume":"115","author":"Bayer","year":"2011","journal-title":"J. Phys. Chem. C."},{"key":"ref_169","doi-asserted-by":"crossref","first-page":"806","DOI":"10.1016\/j.mee.2009.02.018","article-title":"Vertically aligned multi-walled carbon nanotubes growth on platinum electrodes for bio-impedance applications","volume":"86","author":"Gabriel","year":"2009","journal-title":"Microelectron. Eng."},{"key":"ref_170","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1038\/nnano.2006.56","article-title":"Direct growth of aligned carbon nanotubes on bulk metals","volume":"1","author":"Talapatra","year":"2006","journal-title":"Nat. Nano."},{"key":"ref_171","doi-asserted-by":"crossref","unstructured":"Matthews, K.D., Lemaitre, M.G., Kim, T., Chen, H., Shim, M., and Zuo, J.M. (2006). Growth modes of carbon nanotubes on metal substrates. J. Appl. Phys., 100.","DOI":"10.1063\/1.2219000"},{"key":"ref_172","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1021\/nl0347233","article-title":"Glucose biosensors based on carbon nanotube nanoelectrode ensembles","volume":"4","author":"Lin","year":"2004","journal-title":"Nano Lett."},{"key":"ref_173","doi-asserted-by":"crossref","first-page":"1414","DOI":"10.1016\/j.susc.2010.05.002","article-title":"Characterization of thiol-functionalized carbon nanotubes on gold surfaces","volume":"604","author":"Minati","year":"2010","journal-title":"Surf. Sci."},{"key":"ref_174","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2009\/187615","article-title":"Carbon nanotube-based electrochemical sensors: Principles and applications in biomedical systems","volume":"2009","author":"Hu","year":"2009","journal-title":"J. Sens."},{"key":"ref_175","doi-asserted-by":"crossref","first-page":"4247","DOI":"10.1016\/j.electacta.2008.12.043","article-title":"; Rahman A.; Shukla N.K. SAM-modified microdisc electrode arrays (MDEAs) with functionalized carbon nanotubes","volume":"55","author":"Rub","year":"2010","journal-title":"Electrochim. Acta."},{"key":"ref_176","doi-asserted-by":"crossref","first-page":"1910","DOI":"10.1039\/c2cc16019f","article-title":"Vertical self-assembly of modified multiwalled carbon nanotubes on gold surfaces induced by chitosan and Tween","volume":"48","author":"Cao","year":"2012","journal-title":"Chem. Commun."},{"key":"ref_177","first-page":"523","article-title":"Third generation horseradish peroxidase biosensor based on self-assembling carbon nanotubes to gold electrode surface","volume":"16","author":"Juan","year":"2005","journal-title":"Chin. Chem. Lett."},{"key":"ref_178","doi-asserted-by":"crossref","first-page":"6584","DOI":"10.1039\/c0cc01148g","article-title":"Selective adsorption of dithiolate-modified multi-wall carbon nanotubes onto alkanethiol self-assembled monolayers on Au(111)","volume":"46","author":"Kim","year":"2010","journal-title":"Chem. Commun."},{"key":"ref_179","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/S1388-2481(03)00076-6","article-title":"Peroxidase activity of enzymes bound to the ends of single-wall carbon nanotube forest electrodes","volume":"5","author":"Yu","year":"2003","journal-title":"Electrochem. Commun."},{"key":"ref_180","unstructured":"Lai, K.W.C., Fung, C.K.M., and Li, W.J. (July, January 15\u2013). A Systematic Approach to Fabricate CNT-Based Nano Devices: Combining DEP and Microspotting Technologies. Nagoya, Japan."},{"key":"ref_181","unstructured":"Boero, C., Carrara, S., and de Micheli, G. (November, January 10\u2013). New Technologies for Nanobiosensing and Their Applications to Real-Time Monitoring. San Diego, CA, USA."},{"key":"ref_182","unstructured":"Lai, K.W.C., and Xi, N. (January, January 16\u2013). Novel Carbon Nanotube Deposition System for Fabricating Nano Devices. Bangkok, Thailand."},{"key":"ref_183","unstructured":"Lai, K.W.C., Fung, C.K.M., and Li, W.J. (June, January 12\u2013). Fabrication of CNT Nanosensors by Combining Micro-Robotic Spotting and DEP Technologies. Nagoya, Japan."},{"key":"ref_184","first-page":"169","article-title":"A wireless-implantable microsystem for continuous blood glucose monitoring, biomedical circuits and systems","volume":"3","author":"Ahmadi","year":"2009","journal-title":"Trans. IEEE."},{"key":"ref_185","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1109\/TBCAS.2010.2042809","article-title":"Low-power low-voltage current readout circuit for inductively powered implant system","volume":"4","author":"Haider","year":"2010","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_186","unstructured":"Lin, L., Qureshi, W.A., Xiaowen, L., and Mason, A.J. (November, January 3\u2013). Amperometric Instrumentation System with On-Chip Electrode Array for Biosensor Application. Paphos, Cyprus."},{"key":"ref_187","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1109\/TBCAS.2008.918282","article-title":"A wireless IC for wide-range neurochemical monitoring using amperometry and Fast-scan cyclic voltammetry","volume":"2","author":"Roham","year":"2008","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_188","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1007\/s10470-009-9393-8","article-title":"A novel current-mode multi-channel integrating ADC","volume":"63","author":"Nambiar","year":"2010","journal-title":"Analog Integr. Circuits Sign. Process."},{"key":"ref_189","doi-asserted-by":"crossref","first-page":"1280","DOI":"10.1109\/JSEN.2006.881351","article-title":"On-chip electrochemical analysis system using nanoelectrodes and bioelectronic CMOS chip","volume":"6","author":"Zhu","year":"2006","journal-title":"IEEE Sens. J."},{"key":"ref_190","doi-asserted-by":"crossref","first-page":"1339","DOI":"10.1109\/TCSI.2008.2005927","article-title":"Current-mirror based potentiostats for three-electrode amperometric electrochemical sensors","volume":"56","author":"Ahmadi","year":"2009","journal-title":"IEEE Trans. Circuits Syst. I."},{"key":"ref_191","unstructured":"Bard, A.J., and Faulkner, L.R. (1980). Electrochemical Methods: Fundamentals and Applications, Wiley."},{"key":"ref_192","unstructured":"Razavi, B. (2001). Design of Analog CMOS Integrated Circuits, McGraw-Hill. Chapter 12."},{"key":"ref_193","doi-asserted-by":"crossref","first-page":"1856","DOI":"10.1109\/JSEN.2009.2031347","article-title":"Fabrication and packaging of a dual sensing electrochemical biotransducer for glucose and lactate useful in intramuscular physiologic status monitoring","volume":"9","author":"Rub","year":"2009","journal-title":"IEEE Sens. J."},{"key":"ref_194","unstructured":"De Venuto, D., Torre, M.D., Boero, C., Carrara, S., and de Micheli, G. (November, January 1\u2013). A Novel Multi-Working Electrode Potentiostat for Electrochemical Detection of Metabolites. Waikoloa, HI, USA."},{"key":"ref_195","unstructured":"Ghoreishizadeh, S., Carrara, S., and de Micheli, G. (November, January 10\u2013). Circuit Design for Human Metabolites Biochip. San Diego, CA, USA."},{"key":"ref_196","doi-asserted-by":"crossref","unstructured":"Briman, M., Bradley, K., and Gruner, G. (2006). Source of 1\/f noise in carbon nanotube devices. J. Appl. Phys., 100.","DOI":"10.1063\/1.2210570"},{"key":"ref_197","unstructured":"Yang, Z., Zhao, Q., Keefer, E., and Liu, W. (2009, January 11). Noise Characterization, Modeling, and Reduction for In Vivo Neural Recording. Singapore."},{"key":"ref_198","doi-asserted-by":"crossref","first-page":"1074","DOI":"10.1063\/1.1755429","article-title":"Comprehensive study of noise processes in electrode electrolyte interfaces","volume":"96","author":"Hassibi","year":"2004","journal-title":"J. Appl. Phys."},{"key":"ref_199","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1109\/JPROC.2008.927494","article-title":"Energy harvesting from human and machine motion for wireless electronic devices","volume":"96","author":"Mitcheson","year":"2008","journal-title":"Proc. IEEE."},{"key":"ref_200","doi-asserted-by":"crossref","unstructured":"Silay, K.M., Dehollain, C., and Declercq, M. (2008, January 22\u201325). Improvement of Power Efficiency of Inductive Links for Implantable Devices. Istanbul, Turkey.","DOI":"10.1109\/RME.2008.4595767"},{"key":"ref_201","doi-asserted-by":"crossref","first-page":"2825","DOI":"10.1109\/JSEN.2011.2170676","article-title":"Inductive power link for a wireless cortical implant with two-body packaging","volume":"11","author":"Silay","year":"2011","journal-title":"IEEE Sens. J."},{"key":"ref_202","doi-asserted-by":"crossref","unstructured":"Finkenzeller, K. (2010). RFID Handbook, Wiley. [3rd ed.].","DOI":"10.1002\/9780470665121"},{"key":"ref_203","unstructured":"Activa RC Recharging System 37751. Medtronic."},{"key":"ref_204","unstructured":"Olivo, J., Carrara, S., and de Micheli, G. (May, January 13\u2013). IronIC Patch: A Wearable Device for the Remote Powering and Connectivity of Implantable Systems. Graz, Austria."},{"key":"ref_205","first-page":"42","article-title":"Function of an implanted tissue glucose sensor for more than 1 year in animals","volume":"2","author":"Kumosa","year":"2010","journal-title":"Sci. Transl. Med."},{"key":"ref_206","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1016\/S1367-5931(02)00371-X","article-title":"Implantable chemical sensors for real time clinical monitoring: Progress and challenges","volume":"6","author":"Frost","year":"2002","journal-title":"Curr. Opin. Chem. Biol."},{"key":"ref_207","unstructured":"Rather, B.D., Hoffman, A.S., Schoen, F.J., and Lemons, J.E. (2004). Biomaterials Science: An Introduction to Materials in Medicine, Elsevier Academic Press. [2nd ed.]."},{"key":"ref_208","doi-asserted-by":"crossref","unstructured":"Williams, D.F. (1999). The Williams Dictionary of Biomaterials, Liverpool University Press.","DOI":"10.5949\/UPO9781846314438"},{"key":"ref_209","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/S0168-3659(98)00178-3","article-title":"Issues and perspectives on the biocompatibility and immunotoxicity evaluation of implanted controlled release systems","volume":"57","author":"Anderson","year":"1999","journal-title":"J. Control. Release"},{"key":"ref_210","unstructured":"(1992). Biological Compatibility of Medical Devices. Part 5. Tests for Cytotoxicity: In Vitro Methods, ISO 10993; ISO."},{"key":"ref_211","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1016\/j.cbpa.2007.05.030","article-title":"Designing synthetic materials to control stem cell phenotype","volume":"11","author":"Saha","year":"2007","journal-title":"Curr. Opin. Chem. Biol."},{"key":"ref_212","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1002\/(SICI)1097-4636(19980615)40:4<586::AID-JBM10>3.0.CO;2-E","article-title":"Engineering the tissue which encapsulates subcutaneous implants. II. Plasma\u2013tissue exchange properties","volume":"40","author":"Sharkawy","year":"1998","journal-title":"J. Biomed. Mater. Res."},{"key":"ref_213","doi-asserted-by":"crossref","first-page":"4880","DOI":"10.1016\/j.biomaterials.2007.07.037","article-title":"Decreased Staphylococcus epidermis adhesion and increased osteoblast functionality on antibiotic-loaded titania nanotubes","volume":"28","author":"Popat","year":"2007","journal-title":"Biomaterials"},{"key":"ref_214","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1016\/S0956-5663(00)00088-9","article-title":"Nanoporous anti-fouling silicon membranes for biosensor applications","volume":"15","author":"Desai","year":"2000","journal-title":"Biosens. Bioelectron"},{"key":"ref_215","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1002\/jbm.a.31824","article-title":"In Vitro and in vivo characterization of porous poly-L-lactic acid coatings for subcutaneously implanted glucose sensors","volume":"87","author":"Koschwanez","year":"2008","journal-title":"J. Biomed. Mater. Res. Part A."},{"key":"ref_216","doi-asserted-by":"crossref","first-page":"1278","DOI":"10.1016\/j.bios.2007.11.010","article-title":"Use of hydrogel coating to improve the performance of implanted glucose sensors","volume":"23","author":"Yu","year":"2008","journal-title":"Biosens. Bioelectron"},{"key":"ref_217","doi-asserted-by":"crossref","first-page":"1665","DOI":"10.1016\/S0142-9612(97)00125-7","article-title":"Biocompatible, glucose-permeable hydrogel for in situ coating of implantable biosensors","volume":"18","author":"Quinn","year":"1997","journal-title":"Biomaterials"},{"key":"ref_218","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/0142-9612(95)98856-9","article-title":"Photo-crosslinked copolymers of 2-hydroxyethyl methacrylate, poly (ethylene glycol) tetra-acrylate and ethylene dimethacrylate for improving biocompatibility of biosensors","volume":"16","author":"Quinn","year":"1995","journal-title":"Biomaterials"},{"key":"ref_219","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1089\/152091504773731320","article-title":"The effect of local subcutaneous delivery of vascular endothelial growth factor on the function of a chronically implanted amperometric glucose sensor","volume":"6","author":"Ward","year":"2004","journal-title":"Diabetes Technol. Ther."},{"key":"ref_220","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1208\/aapsj070122","article-title":"Controlled release of dexamethasone from PLGA microspheres embedded within polyacid-containing PVA hydrogels","volume":"7","author":"Galeska","year":"2005","journal-title":"AAPS J."},{"key":"ref_221","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1002\/jbm.10016","article-title":"In vivo evaluation of a dexamethasone\/PLGA microsphere system designed to suppress the inflammatory tissue response to implantable medical devices","volume":"61","author":"Hickey","year":"2002","journal-title":"J. Biomed. Mater. Res."},{"key":"ref_222","doi-asserted-by":"crossref","unstructured":"Op de Beeck, M., La Manna, A., Buisson, T., Dy, E., Velenis, D., Axisa, F., Soussan, P., and van Hoof, C. (2010, January 13\u201316). An IC-Centric Biocompatible Chip Encapsulation Fabrication Process. Berlin, Germany.","DOI":"10.1109\/ESTC.2010.5642917"},{"key":"ref_223","doi-asserted-by":"crossref","unstructured":"Op de Beeck, M., Qian, K., Fiorini, P., Malachowski, K., and van Hoof, C. (2011, January 9\u201313). Design and Characterization of A Biocompatible Packaging Concept for Implantable Electronic Devices. Long Beach, CA, USA.","DOI":"10.4071\/isom-2011-TA5-Paper2"},{"key":"ref_224","doi-asserted-by":"crossref","unstructured":"Dy, E. (September, January 13\u2013). Biocompatibility Assessment of Advanced Wafer-Level Based Chip Encapsulation 2010. Berlin, Germany.","DOI":"10.1109\/ESTC.2010.5642972"},{"key":"ref_225","doi-asserted-by":"crossref","unstructured":"Rodger, D. (June, January 10\u2013). High-Density Flexible Parylene-Based Multielectrode Arrays for Retinal and Spinal Cord Stimulation 2007. Lyon, France.","DOI":"10.1109\/SENSOR.2007.4300401"},{"key":"ref_226","doi-asserted-by":"crossref","unstructured":"Yao, Y., Gulari, M.N., Casey, B., Wiler, J.A., and Wise, K.D. (August, January 19\u2013). Silicon Microelectrodes with Flexible Integrated Cables for Neural Implant Applications 2007. Cambridge, UK.","DOI":"10.1109\/CNE.2007.369693"},{"key":"ref_227","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1109\/MEMB.2005.1511501","article-title":"Implantable biomedical microsystems for neural prostheses","volume":"24","author":"Stieglitz","year":"2005","journal-title":"IEEE Eng. Med. Biol. Mag."},{"key":"ref_228","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1109\/10.284959","article-title":"Silicon ribbon cables for chronically implantable microelectrode arrays","volume":"41","author":"Hetke","year":"1994","journal-title":"Biomed. Eng. IEEE Trans."},{"key":"ref_229","doi-asserted-by":"crossref","first-page":"2737","DOI":"10.1016\/S0142-9612(02)00007-8","article-title":"Evaluation of MEMS materials of construction for implantable medical devices","volume":"23","author":"Kotzar","year":"2002","journal-title":"Biomaterials"},{"key":"ref_230","doi-asserted-by":"crossref","unstructured":"Topper, M., Klein, M., Buschick, K., Glaw, V., Orth, K., Ehrmann, O., Hutter, M., Oppermann, H., Becker, K.-F., and Braun, T. (2006, January 5). Biocompatible Hybrid Flip Chip Microsystem Integration for Next Generation Wireless Neural Interfaces. San Diego, CA, USA.","DOI":"10.1109\/ECTC.2006.1645734"},{"key":"ref_231","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1111\/j.1399-6576.1995.tb04255.x","article-title":"Bio-\/haemocompatibility: Implications and outcomes for sensors?","volume":"39","author":"Kyrolainen","year":"1995","journal-title":"Acta Anaesthesiol. Scand."},{"key":"ref_232","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1021\/ac00077a015","article-title":"Prevention of the rapid degradation of subcutaneously implanted Ag\/AgCl reference electrodes using polymer coatings","volume":"66","author":"Moussy","year":"1994","journal-title":"Anal. Chem."},{"key":"ref_233","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/S0956-5663(97)00084-5","article-title":"Influence of calcium on glucose biosensor response and on hydrogen peroxide detection","volume":"13","year":"1998","journal-title":"Biosens. Bioelectron"},{"key":"ref_234","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1016\/0956-5663(96)88408-9","article-title":"Poly (methylene blue)-modified thick-film gold electrodes for the electrocatalytic oxidation of NADH and their application in glucose biosensors","volume":"11","author":"Silber","year":"1996","journal-title":"Biosens. Bioelectron"},{"key":"ref_235","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/S0927-7765(99)00148-4","article-title":"Methods for reducing biosensor membrane biofouling","volume":"18","author":"Wisniewski","year":"2000","journal-title":"Colloids Surf. B Biointerfaces"},{"key":"ref_236","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1016\/S1389-1286(01)00302-4","article-title":"Wireless sensor networks: A survey","volume":"38","author":"Akyildiz","year":"2002","journal-title":"Comput. Netw."},{"key":"ref_237","unstructured":"Anderson, R. (2008). Security Engineering: A Guide to Building Dependable Distributed Systems, Wiley. [2nd ed.]."},{"key":"ref_238","doi-asserted-by":"crossref","first-page":"1557","DOI":"10.1177\/193229681100500632","article-title":"A review of the security of insulin pump infusion systems","volume":"5","author":"Paul","year":"2011","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_239","unstructured":"Halperin, D., Heydt-Benjamin, T., Ransford, B., Clark, S., Defend, B., Morgan, W., Fu, K., Kohno, T., and Maisel, W. (May, January 5\u2013). Pacemakers and Implantable Cardiac Defibrillators: Software Radio Attacks and Zero-Power Defenses. Berkeley\/Oakland, CA, USA."},{"key":"ref_240","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1007\/s00216-010-4271-x","article-title":"An implantable biochip to influence patient outcomes following trauma-induced hemorrhage","volume":"399","year":"2011","journal-title":"J. Anal. Bioanal. Chem."},{"key":"ref_241","unstructured":"Rabaey, J.M., Mark, M., Chen, D., Sutardja, C., Tang, C., Gowda, S., Wagner, M., and Werthimer, D. (March, January 14\u2013). Powering and Communicating with mm-Size Implants. Grenoble, France."},{"key":"ref_242","unstructured":"Masny, B.D., Geiselmann, W., and Bretthauer, G. (2011, January 26\u201329). Block Cipher Based Security for Severely Resource-Constrained Implantable Medical Devices. Barcellona, Spain."},{"key":"ref_243","doi-asserted-by":"crossref","unstructured":"Huang, R., and Suh, E. (2010, January 19\u201323). IVEC: Off-Chip Memory Integrity Protection for Both Security and Reliability. Saint-Malo, France.","DOI":"10.1145\/1815961.1816015"},{"key":"ref_244","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1007\/s10916-006-9019-y","article-title":"Personal health record systems and their security protection","volume":"30","author":"Win","year":"2006","journal-title":"J. Med. Syst."},{"key":"ref_245","doi-asserted-by":"crossref","unstructured":"Hosseini-Khayat, S. A. (2011, January 27\u201330). Lightweight Security Protocol for Ultra-Low Power ASIC Implementation for Wireless Implantable Medical Devices. Montreux, Switzerland.","DOI":"10.1109\/ISMICT.2011.5759785"},{"key":"ref_246","unstructured":"Guan, S., Gu, J., Shen, Z., Wang, J., Huang, Y., and Mason, A. (November, January 10\u2013). A Wireless Powered Implantable Bio-Sensor Tag System-on-Chip for Continuous Glucose Monitoring. San Diego, CA, USA."},{"key":"ref_247","doi-asserted-by":"crossref","unstructured":"Gollakota, S., Hassanieh, H., Ransford, B., Katabi, D., and Fu, K. (2011, January 15\u201319). They Can Hear Your Heartbeats: Non-Invasive Security for Implanted Medical Devices. Toronto, ON, Canada.","DOI":"10.1145\/2018436.2018438"},{"key":"ref_248","doi-asserted-by":"crossref","unstructured":"Sorber, J., Shin, M., Peterson, R., Cornelius, C., Mare, S., Prasad, A., Marois, Z., Smithayer, E., and Kotz, D. (2012, January 2\u20133). An Amulet for Trustworthy Wearable mHealth. San Diego, CA, USA.","DOI":"10.1145\/2162081.2162092"},{"key":"ref_249","doi-asserted-by":"crossref","unstructured":"Cornelius, C., and Kotz, D. (2011, January 12\u201315). Recognizing Whether Sensors are on the Same Body. San Francisco, CA, USA.","DOI":"10.1007\/978-3-642-21726-5_21"},{"key":"ref_250","unstructured":"Burleson, W. (2011, January 27\u201330). Physical Layer Security and Privacy with Ultra-Wideband. Montreux, Switzerland."},{"key":"ref_251","unstructured":"Danev, B., Heydt-Benjamin, T., and Capkun, S. (2009, January 10\u201314). Physical-Layer Identification of RFID Devices. Montreal, QC, Canada."},{"key":"ref_252","unstructured":"Burleson, W., Clark, S., Ransford, B., and Fu, K. (June, January 3\u2013). Design Challenges in Secure Implantable Medical Devices. San Francisco, CA, USA."},{"key":"ref_253","doi-asserted-by":"crossref","first-page":"6520","DOI":"10.3390\/s120506520","article-title":"Electrochemical detection of anti-breast-cancer agents in human serum by cytochrome P450-coated carbon nanotubes","volume":"12","author":"Carrara","year":"2012","journal-title":"Sensors"},{"key":"ref_254","doi-asserted-by":"crossref","unstructured":"Carrara, S. (2012). Bio\/CMOS Interfaces and Co-Design, Springer.","DOI":"10.1007\/978-1-4614-4690-3"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/12\/8\/11013\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:51:41Z","timestamp":1760219501000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/12\/8\/11013"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,8,8]]},"references-count":254,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2012,8]]}},"alternative-id":["s120811013"],"URL":"https:\/\/doi.org\/10.3390\/s120811013","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,8,8]]}}}