{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T18:50:17Z","timestamp":1791226217349,"version":"4.1.0"},"reference-count":24,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2012,11,6]],"date-time":"2012-11-06T00:00:00Z","timestamp":1352160000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Immuno-SPR-MS is the combination of immuno-sensors in biochip format with mass spectrometry. This association of instrumentation allows the detection and the quantification of proteins of interest by SPR and their molecular characterization by additional MS analysis. However, two major bottlenecks must be overcome for a wide diffusion of the SPR-MS analytical platform: (i) To warrant all the potentialities of MS, an enzymatic digestion step must be developed taking into account the spot formats on the biochip and (ii) the biological relevancy of such an analytical solution requires that biosensing must be performed in complex media. In this study, we developed a procedure for the detection and the characterization at ~1 \u00b5g\/mL of the LAG3 protein spiked in human plasma. The analytical performances of this new method was established, particularly its specificity (S\/N &gt; 9) and sensitivity (100% of LAG3 identification with high significant mascot score &gt;68 at the femtomole level). The collective and automated on-chip MALDI-MS imaging and analysis based on peptidic fragments opens numerous applications in the fields of proteomics and diagnosis.<\/jats:p>","DOI":"10.3390\/s121115119","type":"journal-article","created":{"date-parts":[[2012,11,6]],"date-time":"2012-11-06T11:18:13Z","timestamp":1352200693000},"page":"15119-15132","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Immuno-MALDI-MS in Human Plasma and On-Chip Biomarker Characterizations at the Femtomole Level"],"prefix":"10.3390","volume":"12","author":[{"given":"Alain","family":"Rouleau","sequence":"first","affiliation":[{"name":"Institut FEMTO-ST, Universit\u00e9 de Franche Comt\u00e9, CLIPP (Clinical-Innovation Proteomic Platform), 25044 Besan\u00e7on, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marven","family":"Osta","sequence":"additional","affiliation":[{"name":"Sant\u00e9 STIC, CLIPP (Clinical-Innovation Proteomic Platform), Universit\u00e9 de Bourgogne, Centre Hospitalier Universitaire de Dijon, 21000 Dijon, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G\u00e9raldine","family":"Lucchi","sequence":"additional","affiliation":[{"name":"Sant\u00e9 STIC, CLIPP (Clinical-Innovation Proteomic Platform), Universit\u00e9 de Bourgogne, Centre Hospitalier Universitaire de Dijon, 21000 Dijon, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"Ducoroy","sequence":"additional","affiliation":[{"name":"Sant\u00e9 STIC, CLIPP (Clinical-Innovation Proteomic Platform), Universit\u00e9 de Bourgogne, Centre Hospitalier Universitaire de Dijon, 21000 Dijon, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wilfrid","family":"Boireau","sequence":"additional","affiliation":[{"name":"Institut FEMTO-ST, Universit\u00e9 de Franche Comt\u00e9, CLIPP (Clinical-Innovation Proteomic Platform), 25044 Besan\u00e7on, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2012,11,6]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1442","DOI":"10.1002\/pmic.200800616","article-title":"Immuno-MALDI-TOF MS: New perspectives for clinical applications of mass spectrometry","volume":"9","author":"Sparbier","year":"2009","journal-title":"Proteomics"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"5969","DOI":"10.1021\/pr1007587","article-title":"Mass spectrometric immunoassay for quantitative determination of protein biomarker isoforms","volume":"9","author":"Trenchevska","year":"2010","journal-title":"J. Proteome Res."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1373\/clinchem.2009.137323","article-title":"Selected reaction monitoring-mass spectrometric immunoassay responsive to parathyroid hormone and related variants","volume":"56","author":"Lopez","year":"2010","journal-title":"Clin. Chem."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"4193","DOI":"10.1021\/ac000167a","article-title":"Combination of biomolecular interaction analysis and mass spectrometric amino acid sequencing","volume":"72","author":"Natsume","year":"2000","journal-title":"Anal. Chem."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2355","DOI":"10.1002\/pmic.200401353","article-title":"Optimizing the surface plasmon resonance\/mass spectrometry interface for functional proteomics applications: how to avoid and utilize nonspecific adsorption","volume":"6","author":"Larsericsdotter","year":"2006","journal-title":"Proteomics"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2184","DOI":"10.1016\/j.bios.2008.11.020","article-title":"Development of an on-line SPR-digestion-nanoLC-MS\/MS system for the quantification and identification of interferon-gamma in plasma","volume":"24","author":"Stigter","year":"2009","journal-title":"Biosen. Bioelectr."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1002\/1099-1352(200005\/06)13:3<140::AID-JMR496>3.0.CO;2-P","article-title":"Practical considerations in BIA\/MS: Optimizing the biosensor-mass spectrometry interface","volume":"13","author":"Nedelkov","year":"2000","journal-title":"J. Mol. Recogn."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"5987","DOI":"10.1021\/ac070608r","article-title":"Development of surface plasmon resonance mass spectrometry array platform","volume":"79","author":"Nedelkov","year":"2007","journal-title":"Anal. Chem."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"7695","DOI":"10.1021\/ac901140m","article-title":"Hyphenation of surface plasmon resonance imaging to matrix-assisted laser desorption ionization mass spectrometry by on-chip mass spectrometry and tandem mass spectrometry analysis","volume":"81","author":"Bellon","year":"2009","journal-title":"Anal. Chem."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1016\/j.bios.2008.06.030","article-title":"Revisited BIA-MS combination: entire \u201con-a-chip\u201d processing leading to the proteins identification at low femtomole to sub-femtomole levels","volume":"24","author":"Boireau","year":"2009","journal-title":"Biosen. Bioelectr."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1039\/C1AN15659D","article-title":"Gold patterned biochips for on-chip immuno-MALDI-TOF MS: SPR imaging coupled multi-protein MS analysis","volume":"137","author":"Kim","year":"2012","journal-title":"Analyst"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1007\/s00216-012-6130-4","article-title":"Surface plasmon resonance imaging in arrays coupled with mass spectrometry (SUPRA-MS): Proof of concept of on-chip characterization of a potential breast cancer marker in human plasma","volume":"404","author":"Lucchi","year":"2012","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/j.canlet.2005.04.015","article-title":"A soluble lymphocyte activation gene-3 (sLAG-3) protein as a prognostic factor in human breast cancer expressing estrogen or progesterone receptors","volume":"235","author":"Triebel","year":"2006","journal-title":"Cancer Lett."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1074\/mcp.T500022-MCP200","article-title":"Microwave-assisted protein preparation and enzymatic digestion in proteomics","volume":"5","author":"Sun","year":"2006","journal-title":"Mol. Cell. Proteom."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Kardous, F., El Fissi, L., Friedt, J.M., Boireau, W., Yahiaoui, R., Manceau, J.F., and Ballandras, S.J. (2011). Integrated active mixing and biosensing using low frequency vibrating mixer and Love-wave sensor for real time detection of antibody binding event. Appl. Phys., 109, n\u00b0094701.","DOI":"10.1063\/1.3576113"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"3671","DOI":"10.1002\/elps.200600065","article-title":"Surface plasmon resonance-enabled mass spectrometry arrays","volume":"27","author":"Nedelkov","year":"2006","journal-title":"Electrophoresis"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1002\/1615-9861(200108)1:8<955::AID-PROT955>3.0.CO;2-P","article-title":"Simplified sample preparation method for protein identification by matrix-assisted laser desorption\/ionization mass spectrometry: In-gel digestion on the probe surface","volume":"1","author":"Stensballe","year":"2001","journal-title":"Proteomics"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1071","DOI":"10.1016\/j.apsusc.2008.05.086","article-title":"TOF-SIMS structural characterization of self-assembly monolayer of cytochrome b5 onto gold substrate","volume":"255","author":"Aoyagi","year":"2008","journal-title":"Appl. Surf. Sci."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1002\/jmr.1106","article-title":"Label-free sensing and atomic force spectroscopy for the characterization of protein-DNA and protein-protein interactions: Application to estrogen receptors","volume":"24","author":"Berthier","year":"2011","journal-title":"Mol. Recog."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1016\/j.trac.2010.09.003","article-title":"Advances in surface plasmon resonance biosensor technology towards high-throughput food-safety analysis","volume":"29","author":"Situ","year":"2010","journal-title":"TrAC Trends Anal. Chem."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"4942","DOI":"10.1021\/ac200679t","article-title":"Noncovalent antibody immobilization on porous silicon combined with miniaturized solid-phase extraction (SPE) for array based immunoMALDI assays","volume":"83","author":"Yan","year":"2011","journal-title":"Anal. Chem."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1002\/prca.201000093","article-title":"MALDI-TOF MS profiling as the first-tier screen for sickle cell disease in neonates: matching throughput to objectives","volume":"5","author":"Hachani","year":"2011","journal-title":"Proteomics Clin. Appl."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2265","DOI":"10.1021\/ac1030804","article-title":"Hemoglobin variant analysis via direct surface sampling of dried blood spots coupled with high-resolution mass spectrometry","volume":"83","author":"Edwards","year":"2011","journal-title":"Anal. Chem."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1021\/pr034086h","article-title":"Mass spectrometric quantitation of peptides and proteins using Stable Isotope Standards and Capture by Anti-Peptide Antibodies (SISCAPA)","volume":"3","author":"Anderson","year":"2004","journal-title":"Proteom. Res."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/12\/11\/15119\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:53:21Z","timestamp":1760219601000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/12\/11\/15119"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,11,6]]},"references-count":24,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2012,11]]}},"alternative-id":["s121115119"],"URL":"https:\/\/doi.org\/10.3390\/s121115119","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,11,6]]}}}