{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T23:13:43Z","timestamp":1786230823908,"version":"build-2736575974"},"reference-count":32,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2012,12,3]],"date-time":"2012-12-03T00:00:00Z","timestamp":1354492800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This work describes a plantar force measurement system. The MEMS pressure sensor, as the key sensing element, is designed, fabricated and embedded into a flexible silicon oil-filled bladder made of silicon rubber to constitute a single sensing unit. A conditioning circuit is designed for signal processing and data acquisition. The characteristics of the plantar force sensing unit are investigated by both static and dynamic tests. A comparison of characteristics between the proposed plantar force sensing unit and a commercial flexible force sensor is presented. A practical experiment of plantar force measurement has been carried out to validate the system. The results demonstrate that the proposed measurement system has a potential for success in the application of plantar force measurement during normal gait.<\/jats:p>","DOI":"10.3390\/s121216628","type":"journal-article","created":{"date-parts":[[2012,12,4]],"date-time":"2012-12-04T12:53:43Z","timestamp":1354625623000},"page":"16628-16640","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Design and Test of a Soft Plantar Force Measurement System for Gait Detection"],"prefix":"10.3390","volume":"12","author":[{"given":"Xuefeng","family":"Zhang","sequence":"first","affiliation":[{"name":"State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, No. 28, Xianning West Road, Xi'an, Shaanxi 710049, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yulong","family":"Zhao","sequence":"additional","affiliation":[{"name":"State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, No. 28, Xianning West Road, Xi'an, Shaanxi 710049, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhengyong","family":"Duan","sequence":"additional","affiliation":[{"name":"State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, No. 28, Xianning West Road, Xi'an, Shaanxi 710049, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Liu","sequence":"additional","affiliation":[{"name":"State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, No. 28, Xianning West Road, Xi'an, Shaanxi 710049, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2012,12,3]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1109\/TMECH.2006.878550","article-title":"Design and control of an exoskeleton for the elderly and patients","volume":"11","author":"Kong","year":"2006","journal-title":"IEEE\/ASME Trans. Mechatron"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1123\/jab.21.2.189","article-title":"An ankle-foot orthosis powered by artificial pneumatic muscles","volume":"21","author":"Ferris","year":"2005","journal-title":"J. Appl. Biomech"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1109\/TMECH.2008.2008803","article-title":"A gait monitoring system based on air pressure sensors embedded in a shoe","volume":"14","author":"Kong","year":"2009","journal-title":"IEEE\/ASME Trans. Mechatron"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2255","DOI":"10.3390\/s120202255","article-title":"Gait analysis using wearable sensors","volume":"12","author":"Tao","year":"2012","journal-title":"Sensors"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1016\/j.gaitpost.2011.12.004","article-title":"Comparison of plantar pressure distribution in adolescent runners at low vs. high running velocity","volume":"35","author":"Fourchet","year":"2012","journal-title":"Gait Posture"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1016\/j.gaitpost.2011.10.362","article-title":"The effect of a long-distance run on plantar pressure distribution during running","volume":"35","author":"Willems","year":"2012","journal-title":"Gait Posture"},{"key":"ref_7","first-page":"45","article-title":"Motion synthesis and force distribution analysis for a biped robot","volume":"13","author":"Trojnacki","year":"2011","journal-title":"Acta Bioengin. Biomech"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Huang, B., Chen, M., Shi, X., and Xu, Y. (2007, January 8\u201311). Gait Event Detection with Intelligent Shoes. Seogwipo-si, Korea.","DOI":"10.1109\/ICIA.2007.4295799"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1109\/TITB.2007.899493","article-title":"Gait analysis using a shoe-integrated wireless sensor system","volume":"12","author":"Bamberg","year":"2008","journal-title":"IEEE Trans. Inform. Technol. Biomed"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1109\/TBME.2010.2046738","article-title":"Monitoring of posture allocations and activities by a shoe-based wearable sensor","volume":"58","author":"Sazonov","year":"2011","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1016\/j.medengphy.2011.01.001","article-title":"An in-shoe device to measure plantar pressure during daily human activity","volume":"33","author":"Saito","year":"2011","journal-title":"Med. Eng. Phys"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1007\/s005420100092","article-title":"A flexible encapsulated MEMS pressure sensor system for biomechanical applications","volume":"7","author":"Lee","year":"2001","journal-title":"Microsyst. Technol"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1088\/0957-0233\/10\/1\/017","article-title":"Plantar pressure-measurement sensors","volume":"10","author":"Urry","year":"1999","journal-title":"Meas. Sci. Technol"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1080\/00140130210136963","article-title":"Accuracy and precision of two in-shoe pressure measurement systems","volume":"45","author":"Hsiao","year":"2002","journal-title":"Ergonomics"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Chedevergne, F., Faivre, A., and Dahan, M. (2006, January 25\u201328). Development of a Mechatronical Device to Measure Plantar Pressure for Medical Prevention of Gait Issues. Luoyang, China.","DOI":"10.1109\/ICMA.2006.257749"},{"key":"ref_16","unstructured":"De Rossi, S.M.M., Lenzi, T., Vitiello, N., Donati, M., Persichetti, A., Giovacchini, F., Vecchi, F., and Carrozza, M.C. (September, January 30). Development of an In-Shoe Pressure-Sensitive Device for Gait Analysis. Boston, MA, USA."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1109\/TITB.2009.2038904","article-title":"In-Shoe plantar pressure measurement and analysis system based on fabric pressure sensing array","volume":"14","author":"Shu","year":"2010","journal-title":"IEEE Trans. Inform. Technol. Biomed"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/j.sna.2009.07.010","article-title":"Development of a piezoelectric polymer film sensor for plantar normal and shear stress measurements","volume":"154","author":"Lekkala","year":"2009","journal-title":"Sens. Actuators A Phys"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.sna.2011.11.006","article-title":"Flexible polyimide-based force sensor","volume":"173","author":"Dobrzynska","year":"2011","journal-title":"Sens. Actuators A Phys"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1016\/j.proche.2009.07.216","article-title":"A flexible capacitive device for pressure and tactile sensing","volume":"1","author":"Petropoulos","year":"2009","journal-title":"Procedia Chem"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.mee.2012.06.005","article-title":"Development of a flexible PDMS capacitive pressure sensor for plantar pressure measurement","volume":"99","author":"Lei","year":"2012","journal-title":"Microelectron. Eng"},{"key":"ref_22","unstructured":"Wheeler, J., Rohrer, B., Kholwadwala, D., Buerger, S., Givler, R., Neely, J., Hobart, C., and Galambos, P. (2006, January 20\u201322). In-Sole MEMS Pressure Sensing for a Lower-Extremity Exoskeleton. Pisa, Italy."},{"key":"ref_23","unstructured":"Moaveni, S. (2005). Finite Element Analysis: Theory and Application with ANSYS (Simplified Chinese Edition), Pearson Education Asia Limited. [2nd ed.]."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1382","DOI":"10.3390\/s90301382","article-title":"Fabrication and structural design of micro pressure sensors for tire pressure measurement systems (TPMS)","volume":"9","author":"Tian","year":"2009","journal-title":"Sensors"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"4955","DOI":"10.1063\/1.1558223","article-title":"Frontiers of silicon-on-insulator","volume":"93","author":"Celler","year":"2003","journal-title":"J. Appl. Phys"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Darrin, A.G., and Osiander, R. (2011). MEMS packaging materials. MEMS Reference Shelf.","DOI":"10.1007\/978-0-387-47318-5_12"},{"key":"ref_27","unstructured":"Zheng, P. (2010). High Temperature Electronics Packaging Processes and Materials Development. Ph.D. Thesis."},{"key":"ref_28","unstructured":"Chen, T., Zhang, Z.H., Ren, T.L., Miao, G.J., Zhou, C.J., Lin, H.W., and Liu, L.T. (2010). A novel dual-functional MEMS sensor integrating both pressure and temperature units. J. Semicond."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/S0924-4247(00)00310-1","article-title":"New tactile sensor chip with silicone rubber cover","volume":"84","author":"Leineweber","year":"2000","journal-title":"Sens. Actuators A Phys"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/j.sna.2008.02.002","article-title":"Diagnostic of silicon piezoresistive pressure sensors by low frequency noise measurements","volume":"144","year":"2008","journal-title":"Sens. Actuators A Phys"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1007\/BF02522950","article-title":"In-Shoe foot pressure measurement system utilising piezoelectric film transducers","volume":"33","author":"Nevill","year":"1995","journal-title":"Med. Biol. Eng. Comput"},{"key":"ref_32","unstructured":"Wu, Y.Q. (2010). Development of an Approach for Interface Pressure Measurement and Analysis for Study of Sitting. MS. Thesis."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/12\/12\/16628\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:53:59Z","timestamp":1760219639000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/12\/12\/16628"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,12,3]]},"references-count":32,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2012,12]]}},"alternative-id":["s121216628"],"URL":"https:\/\/doi.org\/10.3390\/s121216628","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,12,3]]}}}