{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T13:32:36Z","timestamp":1780061556373,"version":"3.54.0"},"reference-count":34,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2013,5,14]],"date-time":"2013-05-14T00:00:00Z","timestamp":1368489600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Whole cell biosensors always face the challenge of low stability of biological components and short storage life. This paper reports the effects of poly(2-hydroxyethyl methacrylate) (pHEMA) immobilization on a whole cell fluorescence biosensor for the detection of heavy metals (Cu, Pb, Cd), and pesticides (dichlorophenoxyacetic acid  (2,4-D), and chlorpyrifos). The biosensor was produced by entrapping the cyanobacterium Anabaena torulosa on a cellulose membrane, followed by applying a layer of pHEMA, and attaching it to a well. The well was then fixed to an optical probe which was connected to a fluorescence spectrophotometer and an electronic reader. The optimization of the biosensor using several factors such as amount of HEMA and drying temperature were undertaken. The detection limits of biosensor without pHEMA for Cu, Cd, Pb, 2,4-D and chlorpyrifos were 1.195, 0.027, 0.0100, 0.025 and 0.025 \u00b5g\/L respectively. The presence of pHEMA increased the limits of detection to 1.410, 0.250, 0.500, 0.235 and 0.117 \u00b5g\/L respectively. pHEMA is known to enhance the reproducibility of the biosensor with average relative standard deviation (RSD) of \u00b11.76% for all the pollutants tested, 48% better than the biosensor without pHEMA (RSD = \u00b13.73%). In storability test with Cu 5 \u00b5g\/L, the biosensor with pHEMA performed 11.5% better than the test without pHEMA on day-10 and 5.2% better on day-25. pHEMA is therefore a good candidate to be used in whole cell biosensors as it increases reproducibility and enhances biosensor storability.<\/jats:p>","DOI":"10.3390\/s130506394","type":"journal-article","created":{"date-parts":[[2013,5,14]],"date-time":"2013-05-14T11:21:04Z","timestamp":1368530464000},"page":"6394-6404","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":51,"title":["Performance of a Cyanobacteria Whole Cell-Based Fluorescence Biosensor for Heavy Metal and Pesticide Detection"],"prefix":"10.3390","volume":"13","author":[{"given":"Ling Shing","family":"Wong","sequence":"first","affiliation":[{"name":"Faculty of Science, Technology, Engineering and Mathematics, INTI International University, Nilai, Negeri Sembilan 71800, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yook Heng","family":"Lee","sequence":"additional","affiliation":[{"name":"Faculty of Science and Technology\/South-East Asia Disaster Prevention Research Institute,  University Kebangsaan Malaysia, Bangi, Selangor 43600, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Salmijah","family":"Surif","sequence":"additional","affiliation":[{"name":"Faculty of Science and Technology, University Kebangsaan Malaysia, Bangi, Selangor 43600, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2013,5,14]]},"reference":[{"key":"ref_1","first-page":"112","article-title":"Heavy metal pollution and human biotoxic effects","volume":"2","author":"Duruibe","year":"2007","journal-title":"Int. J. Phys. Sci."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1051\/agro:2008054","article-title":"Agronomy for sustainable agriculture: A review","volume":"29","author":"Lichtfouse","year":"2009","journal-title":"Agron. Sustain. Dev."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Lichtfouse, E., Schwarzbauer, J., and Robert, D. (2005). Environmental Chemistry, Green Chemistry and Pollutants in Ecosystems, Springer.","DOI":"10.1007\/b137751"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1016\/S0021-9673(00)00151-5","article-title":"Recent and future developments of liquid chromatography in pesticide trace analysis","volume":"892","author":"Hogendoorn","year":"2000","journal-title":"J. Chromatogr. A"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1016\/0956-5663(95)96929-S","article-title":"Biosensor for environmental applications","volume":"10","author":"Rogers","year":"1995","journal-title":"Biosens. Bioelectron."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1016\/S0021-9673(99)00511-7","article-title":"Trace analysis of pesticides by gas chromatography","volume":"843","year":"1999","journal-title":"J. Chromatogr. A"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1016\/S0956-5663(02)00157-4","article-title":"Optical whole-cell biosensor using Chlorella vulgaris designed for monitoring herbicides","volume":"18","author":"Leclerc","year":"2003","journal-title":"Biosens. Bioelectron."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1166\/sl.2005.006","article-title":"A copper toxicity biosensor using immobilized cyanobacteria","volume":"3","author":"Tay","year":"2005","journal-title":"Anabaena torulosa. Sens. Lett."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1016\/S0925-4005(98)00203-2","article-title":"Detection of environmental pollutants using optical biosensor with immobilized algae cells","volume":"51","author":"Frense","year":"1998","journal-title":"Sens. Actuators B Chem."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"923","DOI":"10.1016\/j.bios.2005.02.013","article-title":"Direct mediatorless electron transport between the monolayer of photosystem II and poly(mercapto-p-benzoquinone) modified gold electrode-new design of biosensor for herbicide detection","volume":"21","author":"Maly","year":"2005","journal-title":"Biosens. Bioelectron."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/j.cclet.2007.10.053","article-title":"Toxicity assessment of heavy metals and organic compounds using CellSense biosensor with E. coli","volume":"19","author":"Wang","year":"2008","journal-title":"Chin. Chem. Lett"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/S0956-5663(01)00125-7","article-title":"Review microbial biosensors","volume":"16","year":"2001","journal-title":"Biosens. Bioelectron."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/0167-7799(88)90094-7","article-title":"Immobilized algae and their potential for use as biocatalysts","volume":"6","author":"Trevan","year":"1988","journal-title":"Trends Biotechnol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1016\/S0956-5663(01)00158-0","article-title":"Strand-off tissue based biosensors for the detection of chemical warfare agents using photosynthetic fluorescence induction","volume":"16","author":"Sanders","year":"2001","journal-title":"Biosens. Bioelectron."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/S0003-2670(03)00358-1","article-title":"Whole cell immobilized biosensors for toxicity assessment of a wastewater treatment plant treating phenolic-containing waste","volume":"487","author":"Philp","year":"2003","journal-title":"Analy. Chim. Acta"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"162","DOI":"10.3923\/ajb.2008.162.168","article-title":"Toxicity biosensor for the evaluation of cadmium toxicity based on photosynthetic behavior of cyanobacteria Anabaena torulosa","volume":"3","author":"Wong","year":"2008","journal-title":"Asian J. Biochem."},{"key":"ref_17","unstructured":"Brickerstaff, G.F. (1997). Immobilization of Enzymes and Cells, Humane Press."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1007\/BF00250631","article-title":"Immobilization of yeast cells in hydroxyethylmethacrylate gels","volume":"20","author":"Cantarella","year":"1984","journal-title":"Appl. Microbiol. Biotechnol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1995","DOI":"10.1002\/polb.10262","article-title":"Influence of gel composition on the solubility parameter of poly(2-hydroxyethil methacrylate-itaconic acid) hydrogel","volume":"40","author":"Caykara","year":"2002","journal-title":"J. Polym. Sci. B"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/15321799208018377","article-title":"2-hydroxyethyl methacrylate (HEMA): Chemical properties and applications in biomedical fields","volume":"32","author":"Montheard","year":"1992","journal-title":"J. Macromol. Sci."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Ratner, B.D., and Hoffman, A.S. (1976). Hydrogels for Medical and Related Applications, American Chemical Society.","DOI":"10.1021\/bk-1976-0031.ch001"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"779","DOI":"10.2116\/analsci.25.779","article-title":"Biosensors for phenolic compounds by immobilization of tyrosinase in photocurable methacrylic-acrylic membranes of varying hydrophilicities","volume":"25","author":"Sharina","year":"2009","journal-title":"Anal. Sci."},{"key":"ref_23","first-page":"137","article-title":"A preliminary investigation on a histamine biosensor constructed from diamine oxidase immobilized onto a oxygen probe","volume":"10","author":"Norazlina","year":"2006","journal-title":"Malaysia J. Anal. Sci."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"9344","DOI":"10.3390\/s111009344","article-title":"Determination of ammonium ion using a reagentless amperometric biosensor based on immobilized alanine dehydrogenase","volume":"11","author":"Tan","year":"2011","journal-title":"Sensors"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1146\/annurev.pp.42.060191.001525","article-title":"Chlorophyll fluorescence and photosythesis: The basic","volume":"42","author":"Krause","year":"1991","journal-title":"Annu. Rev. Plant Physiol."},{"key":"ref_26","unstructured":"James, D.E. (1978). Culturing Algae, Carolina Biological Supply Company."},{"key":"ref_27","unstructured":"Trainor, F.R. (1979). Introductory Phycology, John Wiley and Sons."},{"key":"ref_28","unstructured":"Carr, N.G., and Whitton, B.A. (1982). The Biology of Cyanobacteria, Blackwell Scientific Publications."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1016\/S0956-5663(01)00305-0","article-title":"Enhancement in the sensitivity of a gas biosensor by using an advanced immobilization of a recombinant bioluminescent bacterium","volume":"17","author":"Gil","year":"2002","journal-title":"Biosens. Bioelectron."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Papageorgiou, G.C. (2004). Chlorophyll A Fluorescence in Advances in Photosynthesis and Respiration, Kluwer Academic Publishers.","DOI":"10.1007\/978-1-4020-3218-9"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1016\/j.bios.2004.09.032","article-title":"A bi-enzymatic whole cell conductometric biosensor for heavy metal ions and pesticides detection in water sample","volume":"21","author":"Chouteau","year":"2005","journal-title":"Biosens. Bioelectron."},{"key":"ref_32","unstructured":"Miller, J.N., and Miller, J.C. (2000). Statistic and Chemometrics for Analytical Chemistry, Pearson Education Limited. [4th ed.]."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1016\/S0956-5663(02)00010-6","article-title":"A glucose biosensor based on microporous polyacrylonitrile synthesized by single rare-earth catalyst","volume":"17","author":"Zheng","year":"2002","journal-title":"Biosens. Bioelectron."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/S0956-5663(02)00186-0","article-title":"Amperometric determination of choline released from rat submandibular gland acinar cells using a choline oxidase biosensor","volume":"18","author":"Razola","year":"2003","journal-title":"Biosens. Bioelectron."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/13\/5\/6394\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:46:43Z","timestamp":1760219203000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/13\/5\/6394"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,5,14]]},"references-count":34,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2013,5]]}},"alternative-id":["s130506394"],"URL":"https:\/\/doi.org\/10.3390\/s130506394","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,5,14]]}}}