{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T22:34:11Z","timestamp":1775082851351,"version":"3.50.1"},"reference-count":90,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2013,6,10]],"date-time":"2013-06-10T00:00:00Z","timestamp":1370822400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This article presents design issues of high-sensitive laser absorption spectroscopy systems for nitrogen oxides (NOx) detection. Examples of our systems and their investigation results are also described. The constructed systems use one of the most sensitive methods, cavity enhanced absorption spectroscopy (CEAS). They operate at different wavelength ranges using a blue\u2014violet laser diode (410 nm) as well as quantum cascade lasers (5.27 \u00b5m and 4.53 \u00b5m). Each of them is configured as a one or two channel measurement device using, e.g., time division multiplexing and averaging. During the testing procedure, the main performance features such as detection limits and measurements uncertainties have been determined. The obtained results are 1 ppb NO2,  75 ppb NO and 45 ppb N2O. For all systems, the uncertainty of concentration measurements does not exceed a value of 13%. Some experiments with explosives are also discussed. A setup equipped with a concentrator of explosives vapours was used. The detection method is based either on the reaction of the sensors to the nitrogen oxides directly emitted by the explosives or on the reaction to the nitrogen oxides produced during thermal decomposition of explosive vapours. For TNT, PETN, RDX and HMX a detection limit better than 1 ng has been achieved.<\/jats:p>","DOI":"10.3390\/s130607570","type":"journal-article","created":{"date-parts":[[2013,6,10]],"date-time":"2013-06-10T11:17:56Z","timestamp":1370863076000},"page":"7570-7598","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":40,"title":["Aspects of the Application of Cavity Enhanced Spectroscopy to Nitrogen Oxides Detection"],"prefix":"10.3390","volume":"13","author":[{"given":"Jacek","family":"Wojtas","sequence":"first","affiliation":[{"name":"Institute of Optoelectronics, Military University of Technology, 2 Gen. S. Kaliskiego St.,  Warsaw 00-908, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Janusz","family":"Mikolajczyk","sequence":"additional","affiliation":[{"name":"Institute of Optoelectronics, Military University of Technology, 2 Gen. S. Kaliskiego St.,  Warsaw 00-908, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zbigniew","family":"Bielecki","sequence":"additional","affiliation":[{"name":"Institute of Optoelectronics, Military University of Technology, 2 Gen. S. Kaliskiego St.,  Warsaw 00-908, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2013,6,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1007\/s11220-007-0029-8","article-title":"Recent advances in trace explosives detection instrumentation","volume":"8","author":"Moore","year":"2007","journal-title":"Sens. Imaging"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"6018","DOI":"10.1364\/AO.41.006018","article-title":"Nitric oxide breath testing by tunable-diode laser absorption spectroscopy: Application in monitoring respiratory inflammation","volume":"41","author":"Roller","year":"2002","journal-title":"Appl. Opt."},{"key":"ref_3","unstructured":"Sigrist, M.W. (1994). Air Monitoring by Spectroscopic Techniques, John Wiley & Sons."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"9039","DOI":"10.1364\/OPEX.13.009039","article-title":"Optical scattering spectroscopy by using tightly focused supercontinuum","volume":"13","author":"Li","year":"2005","journal-title":"Opt. Express"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1081\/ASR-100100844","article-title":"Atomic absorption spectroscopy: A tutorial review","volume":"34","author":"Lagalante","year":"1999","journal-title":"Appl. Spectrosc. Rev."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/S0009-2614(98)00785-4","article-title":"Integrated cavity output analysis of ultra-weak absorption","volume":"293","year":"1998","journal-title":"Chem. Phys. Lett."},{"key":"ref_7","first-page":"427","article-title":"Global atmospheric monitoring with SCIAMACHY","volume":"24","author":"Noel","year":"1999","journal-title":"Phys. Chem. Earth"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1016\/j.snb.2008.05.011","article-title":"Deep UV based DOAS system for the monitoring of nitric oxide using ratiometric separation techniques","volume":"134","author":"Dooly","year":"2008","journal-title":"Sens. Actuators B"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Shao, J., Wang, H., Zhou, W., Peng, B., and Ying, C. (2010, January 18\u201320). The Highly Sensitive Detection of NO Using FAMOS by a Fully-Diode-Laser-Based UV System. Chengdu, China.","DOI":"10.1109\/ICBBE.2010.5516141"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1007\/s00340-008-3308-8","article-title":"Incoherent broadband cavity enhanced absorption spectroscopyfor in situ measurements of NO2 with a blue light emitting diode","volume":"94","author":"Wu","year":"2009","journal-title":"Appl. Phys. B"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"4053","DOI":"10.1364\/AO.35.004053","article-title":"Ultrasensitive, visible tunable diode laser detection of NO2","volume":"35","author":"Sonnenfroh","year":"1996","journal-title":"Appl. Opt."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.cplett.2009.12.073","article-title":"Quantum cascade lasers in chemical physics","volume":"487","author":"Curl","year":"2010","journal-title":"Chem. Phys. Lett."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1007\/s003400100562","article-title":"Spectroscopic detection of biological NO with a quantum cascade laser","volume":"72","author":"Menzel","year":"2001","journal-title":"Appl. Phys. B"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"5522","DOI":"10.1364\/AO.40.005522","article-title":"Cavity ringdown spectroscopic detection of nitric oxide with a continuous-wave quantum-cascade laser","volume":"40","author":"Kosterev","year":"2001","journal-title":"Appl. Opt."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1007\/s00340-011-4839-y","article-title":"Wavelength-modulation-spectroscopy for real-time, in situ NO detection in combustion gases with a 5.2 \u03bcm quantum-cascade laser","volume":"106","author":"Chao","year":"2012","journal-title":"Appl. Phys. B"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Namjou, K., Roller, C.B., and McMillen, G. (2007, January 28\u201331). Breath Analysis Using Mid Infrared Tunable Laser Spectroscopy. Atlanta, GA, USA.","DOI":"10.1109\/ICSENS.2007.4388658"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1007\/s00340-009-3423-1","article-title":"Infrared laser-spectroscopic analysis of 14NO and 15NO in human breath","volume":"95","author":"Heinrich","year":"2009","journal-title":"Appl. Phys. B"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Tittel, F.K., Dong, L., Lewicki, R., Lee, G., Peralta, A., and Spagnolo, V. (2012). Sensitive detection of nitric oxide using 5.26 \u03bcm external cavity quantum cascade laser based QEPAS sensor. Proc. SPIE, 8268.","DOI":"10.1117\/12.905621"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Karpf, A., and Rao, G.N. (2011, January 1\u20136). High Sensitivity Detection of NO2Using ICOS and MLIAS. Baltimore, MD, USA.","DOI":"10.1364\/CLEO_AT.2011.JTuI113"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Busch, K.W., and Busch, M.A. (1999). Cavity-Ringdown Spectroscopy, American Chemical Society.","DOI":"10.1021\/bk-1999-0720"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"3763","DOI":"10.1063\/1.1149176","article-title":"Cavity enhanced absorption and cavity enhanced magnetic rotation spectroscopy","volume":"69","author":"Engeln","year":"1998","journal-title":"Rev. Sci. Instrum."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Wojtas, J., Czy\u017cewski, A., Stacewicz, T., Bielecki, Z., and Mikolajczyk, J. (2005). Cavity enhanced spectroscopy for NO2detection. Proc. SPIE, 5954.","DOI":"10.1117\/12.622155"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"4904","DOI":"10.1364\/AO.40.004904","article-title":"Ultrasensitive absorption spectroscopy with a high-finesse optical cavity and off-axis alignment","volume":"40","author":"Paul","year":"2001","journal-title":"App. Opt."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1080\/014423500750040627","article-title":"Cavity ring-down spectroscopy: Experimental schemes and applications","volume":"19","author":"Berden","year":"2000","journal-title":"Int. Rev. Phys. Chem."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1007\/s00340-006-2354-3","article-title":"Sub-PPB NO2 detection by optical feedback cavity-enhanced absorption spectroscopy with a blue diode laser","volume":"85","author":"Courtillot","year":"2006","journal-title":"Appl. Phys. B"},{"key":"ref_26","first-page":"461","article-title":"Sensitive detection of NO2 with cavity enhanced spectroscopy","volume":"36","author":"Wojtas","year":"2006","journal-title":"Opt. Appl."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"363","DOI":"10.12693\/APhysPolA.116.363","article-title":"Cavity enhanced absorption spectroscopy sensor","volume":"116","author":"Nowakowski","year":"2009","journal-title":"Acta Phys. Pol. A"},{"key":"ref_28","first-page":"34","article-title":"Cavity ring down spectroscopy: Detection of trace amounts of matter","volume":"20","author":"Stacewicz","year":"2012","journal-title":"Opt. Electron. Rev."},{"key":"ref_29","unstructured":"High-Resolution Transmission Molecular Absorption Database\u2014HITRAN Available online: http:\/\/www.hitran.com."},{"key":"ref_30","first-page":"77450I-1","article-title":"Application of an optical parametric generator to cavity enhanced experiment","volume":"7745","author":"Rutecka","year":"2010","journal-title":"Proc. SPIE"},{"key":"ref_31","unstructured":"Commercial Lasers Lines Available online: http:\/\/photonics.com\/LinearCharts\/Default.aspx? ChartID=1."},{"key":"ref_32","unstructured":"TopGaN Ltd Available online: http:\/\/topganlasers.com\/."},{"key":"ref_33","unstructured":"Roithner Lasertechnik GmbH Available online: http:\/\/www.roithner-laser.com\/."},{"key":"ref_34","unstructured":"UV, Visible, & IR Laser Diodes Available Online: http:\/\/www.powertechnology.com\/diodes.asp."},{"key":"ref_35","unstructured":"QPhotonics: Laser Diode Online Store Available online: http:\/\/www.qphotonics.com\/home.php? xid=2661dc5f744a077a186530c93bb4888c."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1016\/j.optlaseng.2005.07.006","article-title":"Advanced monitoring techniques and coherent sources","volume":"44","author":"Ferraro","year":"2006","journal-title":"Opt. Lasers Eng."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Nilsson, J., Jeong, Y., Soh, D.B.S., Codemard, C.A., Dupriez, P., Farell, C., Sahu, J.K., Kim, J., Yoo, S., and Payne, D.N. (2005, January 4\u20138). High-Power Fiber Lasers: Progress and Opportunities. Kyoto, Japan.","DOI":"10.1109\/OFC.2005.192624"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.sab.2004.10.001","article-title":"Diode laser atomic absorption spectrometry","volume":"60","author":"Zybin","year":"2005","journal-title":"Spectrochim. Acta B"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1007\/s00340-002-1032-3","article-title":"Off-axis continuous-wave cavity-enhanced absorption spectroscopy of narrow-band and broadband absorbers using red diode lasers","volume":"75","author":"Kasyutich","year":"2002","journal-title":"Appl. Phys. B"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"724","DOI":"10.1021\/ac048715y","article-title":"Detection of nitrogen dioxide by cavity attenuated phase shift spectroscopy","volume":"77","author":"Kebabian","year":"2005","journal-title":"Anal. Chem."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"6040","DOI":"10.1021\/es703204j","article-title":"A practical alternative to chemiluminescence-based detection of nitrogen-dioxide: Cavity attenuated phase shift spectroscopy","volume":"42","author":"Kebabian","year":"2008","journal-title":"Environ. Sci. Tech."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1029\/2005JD006942","article-title":"Measurement of atmospheric NO2 by pulsed cavity ring-down spectroscopy","volume":"111","author":"Osthoff","year":"2006","journal-title":"J. Geophys. Res."},{"key":"ref_43","first-page":"445","article-title":"Mid-Infrared Laser Applications in Spectroscopy","volume":"Volume 89","author":"Sorokina","year":"2003","journal-title":"Solid-State Mid-Infrared Laser Sources"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1007\/s00340-007-2846-9","article-title":"Application of quantum cascade lasers to trace gas analysis","volume":"90","author":"Kosterev","year":"2008","journal-title":"Appl. Phys. B"},{"key":"ref_45","doi-asserted-by":"crossref","unstructured":"Yao, Y., Wang, X., Fan, J.-Y., and Gmachl, C.F. (2010). High performance continuum-to-continuum quantum cascade lasers with a broad gain bandwidth of over 400 cm\u20231. Appl. Phys. Lett., 97.","DOI":"10.1063\/1.3484279"},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Zhao, L., Liu, F., Zhang, J., Wang, L., Liu, J., Li, L., and Wang, Z. (2012). Improved performance of quantum cascade laser with porous waveguide structure. J. Appl. Phys., 112.","DOI":"10.1063\/1.4733696"},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Liu, P.Q., Wang, X., Fan, J.-Y., and Gmachl, C.F. (2011). Single-mode quantum cascade lasers based on a folded Fabry-Perot cavity. Appl. Phys. Lett., 98.","DOI":"10.1063\/1.3554757"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Bai, Y., Tsao, S., Bandyopadhyay, N., Slivken, S., Lu, Q.Y., Caffey, D., Pushkarsky, M., Day, T., and Razeghi, M. (2011). High power, continuous wave, quantum cascade ring laser. Appl. Phys. Lett., 99.","DOI":"10.1063\/1.3672049"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.physe.2012.11.014","article-title":"High temperature operation of edge-emitting photonic-crystal distributed-feedback quantum cascade lasers at \u03bb~7.6 \u03bcm","volume":"48","author":"Wang","year":"2013","journal-title":"Phys. E"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1007\/s00340-009-3865-5","article-title":"External-cavity quantum cascade lasers with fast wavelength scanning","volume":"100","author":"Tsai","year":"2010","journal-title":"Appl. Phys. B"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1016\/j.infrared.2010.07.004","article-title":"Stability of widely tuneable, continuous wave external-cavity quantum cascade laser for absorption spectroscopy","volume":"53","author":"Kasyutich","year":"2010","journal-title":"Infrared Phys. Technol."},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Liu, P.Q., Wang, X., and Gmachl, C.F. (2012). Single-mode quantum cascade lasers employing asymmetric Mach-Zehnder interferometer type cavities. Appl. Phys. Lett., 101.","DOI":"10.1063\/1.4761247"},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Fuchs, P., Seufert, J., Koeth, J., Semmel, J., H\u00f6fling, S., Worschech, L., and Forchel, A. (2010). Widely tunable quantum cascade lasers with coupled cavities for gas detection. Appl. Phys. Lett., 97.","DOI":"10.1063\/1.3514247"},{"key":"ref_54","unstructured":"Daylight Solutions\u2019 Products Based on ECacL(TM) Technology Available online: http:\/\/www.daylightsolutions.com\/products\/."},{"key":"ref_55","unstructured":"Maulini, R. (2006). Broadly Tunable Mid-Infrared Quantum Cascade Lasers for Spectroscopic Applications. [Ph.D. Thesis, Universite de Neuchatel, Institut de Physique]."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1049\/el:20020355","article-title":"Simultaneously at two wavelengths (5.0 and 7.5 \u03bcm) singlemode and tunable quantum cascade distributed feedback lasers","volume":"38","author":"Straub","year":"2002","journal-title":"Electron. Lett."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1038\/415883a","article-title":"Ultra-broadband semiconductor laser","volume":"415","author":"Gmachl","year":"2002","journal-title":"Nature"},{"key":"ref_58","doi-asserted-by":"crossref","unstructured":"Bandyopadhyay, N., Slivken, S., Bai, Y., and Razeghia, M. (2012). High power, continuous wave, room temperature operation of \u03bb~3.4\u03bcm and \u03bb~3.55\u03bcm InP-based quantum cascade lasers. Appl. Phys. Lett., 100.","DOI":"10.1063\/1.4719110"},{"key":"ref_59","doi-asserted-by":"crossref","unstructured":"Laffaille, P.J., Moreno, C., Teissier, R., Bahriz, M., and Baranov, A.N. (2012). High temperature operation of short wavelength InAs-based quantum cascade lasers. AIP Adv., 2.","DOI":"10.1063\/1.4714363"},{"key":"ref_60","doi-asserted-by":"crossref","unstructured":"Bauer, A., Langer, F., Dallner, M., Kamp, M., Motyka, M., Sek, G., Ryczko, K., Misiewicz, J., H\u00f6fling, S., and Forchel, A. (2009). Emission wavelength tuning of interband cascade lasers in the 3\u20134 \u03bcm spectral range. Appl. Phys. Lett., 95.","DOI":"10.1063\/1.3270002"},{"key":"ref_61","doi-asserted-by":"crossref","unstructured":"Basnar, B., Mujagic, E., Andrews, A.M., Roch, T., Schrenk, W., and Strasser, G. (2010). Light induced tuning of quantum cascade lasers. Appl. Phys. Lett., 97.","DOI":"10.1063\/1.3473780"},{"key":"ref_62","doi-asserted-by":"crossref","unstructured":"Lu, Q.Y., Bai, Y., Bandyopadhyay, N., Slivken, S., and Razeghi, M. (2011). 2.4 W room temperature continuous wave operation of distributed feedback quantum cascade lasers. Appl. Phys. Lett., 98.","DOI":"10.1063\/1.3588412"},{"key":"ref_63","doi-asserted-by":"crossref","unstructured":"Mujagic, E., Schwarzer, C., Nobile, M., Detz, H., Ahn, S., Schrenk, W., Chen, J., Gmachl, C., and Strasser, G. (2010, January 16\u201321). Reduced Threshold and High Temperature Operation in Single-Mode Ring Cavity Surface Emitting Quantum Cascade Lasers. San Jose, CA, USA.","DOI":"10.1117\/12.842703"},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1109\/LPT.2009.2020440","article-title":"Broadband distributed-feedback quantum cascade laser array operating from 8.0 to 9.8 \u03bcm","volume":"21","author":"Lee","year":"2009","journal-title":"IEEE Phot. Techn. Lett."},{"key":"ref_65","doi-asserted-by":"crossref","unstructured":"Slivken, S., Bandyopadhyay, N., Tsao, S., Nida, S., Bai, Y., Lu, Q.Y., and Razeghi, M. (2012). Sampled grating, distributed feedback quantum cascade lasers with broad tunability and continuous operation at room temperature. Appl. Phys. Lett., 100.","DOI":"10.1063\/1.4732801"},{"key":"ref_66","doi-asserted-by":"crossref","unstructured":"Kruczek, T., Fedorova, K.A., Sokolovskii, G.S., Teissier, R., Baranov, A.N., and Rafailov, E.U. (2013). InAs\/AlSb widely tunable external cavity quantum cascade laser around 3.2 \u03bcm. Appl. Phys. Lett., 102.","DOI":"10.1063\/1.4774088"},{"key":"ref_67","doi-asserted-by":"crossref","unstructured":"Suchalkin, S., Jung, S., Tober, R., Belkin, M.A., and Belenky, G. (2013). Optically tunable long wavelength infrared quantum cascade laser operated at room temperature. Appl. Phys. Lett., 102.","DOI":"10.1063\/1.4774267"},{"key":"ref_68","unstructured":"Rogalski, A., and Bielecki, Z. (2006). Handbook of Optoelectronics, Taylor & Francis."},{"key":"ref_69","unstructured":"Photonic Devices, Electron Tube Devices and Applied Products Available online: http:\/\/sales.hamamatsu.com\/assets\/pdf\/catsandguides\/p-dev_2012_TOTH0020E02.pdf."},{"key":"ref_70","unstructured":"Hamamatsu, Solid State Division Technical Information SD-12, Characteristics and Use of Infrared Detectors. Available online: http:\/\/sales.hamamatsu.com\/assets\/applications\/SSD\/Characteristics_and_use_of_infrared_detectors.pdf."},{"key":"ref_71","first-page":"453","article-title":"MOCVD growth of Hg1xCdxTe heterostructures for uncooled infrared photodetectors","volume":"12","author":"Piotrowski","year":"2004","journal-title":"Opt. Electron. Rev."},{"key":"ref_72","first-page":"279","article-title":"History of infrared detectors","volume":"20","author":"Rogalski","year":"2012","journal-title":"Opt. Electron. Rev."},{"key":"ref_73","first-page":"44","article-title":"Signal processing system in the cavity enhanced spectroscopy","volume":"16","author":"Wojtas","year":"2008","journal-title":"Opt. Electron. Rev."},{"key":"ref_74","unstructured":"Wojtas, J. (2011). Optoelectronics\u2014Devices and Applications, Intech Publishers."},{"key":"ref_75","unstructured":"Flyckt, S.O., and Marmonier, C. (2002). Photomultiplier Tubes: Principles and Applications, Photonis."},{"key":"ref_76","first-page":"209","article-title":"Maximization of signal to noise ratio in infrared radiation receivers","volume":"10","author":"Bielecki","year":"2002","journal-title":"Opt. Electron. Rev."},{"key":"ref_77","unstructured":"Bielecki, Z., Kolosowski, W., Sedek, E., Wnuk, M., and Wojtas, J. (2009). Transactions on Modelling and Simulations, WIT Press."},{"key":"ref_78","unstructured":"Lyons, R.G. (2010). Understanding Digital Signal Processing, Addison Wesley Pub Co Inc.. [3rd ed.]."},{"key":"ref_79","first-page":"77","article-title":"Ultrasensitive laser spectroscopy for breath analysis","volume":"20","author":"Wojtas","year":"2012","journal-title":"Opt. Electron. Rev."},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1007\/s00340-002-0971-z","article-title":"Sensitive absorption measurements in the near-infrared region using off-axis integrated-cavity-output spectroscopy","volume":"75","author":"Baer","year":"2002","journal-title":"Appl. Phys. B"},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"763","DOI":"10.12693\/APhysPolA.120.763","article-title":"Two-channel optoelectronic sensor employing cavity enhanced absorption spectroscopy","volume":"120","author":"Wojtas","year":"2011","journal-title":"Acta Phys. Pol. A"},{"key":"ref_82","doi-asserted-by":"crossref","unstructured":"Gawron, W., Bielecki, Z., Wojtas, J., Stanaszek, D., Lach, J., and Fimiarz, M. (2012). Infrared detection module for optoelectronic sensors. Proc. SPIE.","DOI":"10.1117\/12.919332"},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"3","DOI":"10.2478\/v10178-012-0001-3","article-title":"Sensors and systems for the detection of explosive devices","volume":"19","author":"Bielecki","year":"2012","journal-title":"Metrol. Meas. Syst."},{"key":"ref_84","first-page":"9","article-title":"Towards optoelectronic detection of explosives","volume":"21","author":"Wojtas","year":"2013","journal-title":"Opt. Electron. Rev."},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"1131","DOI":"10.1002\/jrs.2574","article-title":"Detection and analysis of cyclotrimethylenetrinitramine (RDX) in environmental samples by surface-enhanced Raman spectroscopy","volume":"41","author":"Hatab","year":"2010","journal-title":"J. Raman Spectrosc."},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/j.aca.2012.07.032","article-title":"Determination of nitrocellulose by capillary electrophoresis with laser-induced fluorescence detection","volume":"745","author":"Torrea","year":"2012","journal-title":"Anal. Chim. Acta"},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.sab.2010.11.012","article-title":"New challenges and insights in the detection and spectral identification of organic explosives by laser induced breakdown spectroscopy","volume":"66","author":"Lucena","year":"2011","journal-title":"Spectrochim. Acta B"},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"1229","DOI":"10.12693\/APhysPolA.118.1229","article-title":"Spectroscopy of explosive materials in the THz range","volume":"118","author":"Palka","year":"2010","journal-title":"Acta Phys. Pol. A"},{"key":"ref_89","doi-asserted-by":"crossref","unstructured":"Schubert, H., and Kuznetsov, A. (2005). Detection and Disposal of Improvised Explosives, Springer.","DOI":"10.1007\/978-1-4020-4887-6"},{"key":"ref_90","doi-asserted-by":"crossref","unstructured":"Onat, B.M., Carver, G., and Itzler, M. (2009). A solid-state hyperspectral imager for real time standoff explosives detection using shortwave infrared imaging. Proc. SPIE, 7310.","DOI":"10.1117\/12.820798"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/13\/6\/7570\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:47:17Z","timestamp":1760219237000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/13\/6\/7570"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,6,10]]},"references-count":90,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2013,6]]}},"alternative-id":["s130607570"],"URL":"https:\/\/doi.org\/10.3390\/s130607570","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,6,10]]}}}