{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T14:51:36Z","timestamp":1768747896608,"version":"3.49.0"},"reference-count":20,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2013,8,14]],"date-time":"2013-08-14T00:00:00Z","timestamp":1376438400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Heart failure is a common cardiac disease in elderly patients. After discharge, approximately 50% of all patients are readmitted to a hospital within six months. Recent studies show that home monitoring of heart failure patients can reduce the number of  readmissions. Still, a large number of false positive alarms as well as underdiagnoses in other cases require more accurate alarm generation algorithms. New low-cost sensors for leg edema detection could be the missing link to help home monitoring to its breakthrough. We evaluated a 3D camera-based measurement setup in order to geometrically detect and quantify leg edemas. 3D images of legs were taken and geometric parameters were extracted semi-automatically from the images. Intra-subject variability for five healthy subjects was evaluated. Thereafter, correlation of 3D parameters with body weight and leg circumference was assessed during a clinical study at the Medical University of Graz. Strong correlation was found in between both reference values and instep height, while correlation in between curvature of the lower leg and references was very low. We conclude that 3D imaging might be a useful and cost-effective extension of home monitoring for heart failure patients, though further (prospective) studies are needed.<\/jats:p>","DOI":"10.3390\/s130810584","type":"journal-article","created":{"date-parts":[[2013,8,14]],"date-time":"2013-08-14T11:11:13Z","timestamp":1376478673000},"page":"10584-10598","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Leg Edema Quantification for Heart Failure Patients  via 3D Imaging"],"prefix":"10.3390","volume":"13","author":[{"given":"Dieter","family":"Hayn","sequence":"first","affiliation":[{"name":"Safety and Security Department, AIT Austrian Institute of Technology, Reininghausstr. 13,  Graz 8020, Austria"}]},{"given":"Friedrich","family":"Fruhwald","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Medical University of Graz, Auenbruggerplatz 15, Graz 8036, Austria"},{"name":"Ludwig Boltzmann Institute for Translational Heart Failure Research, Stiftingtalstrasse 24,  Graz 8010, Austria"}]},{"given":"Arthur","family":"Riedel","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Medical University of Graz, Auenbruggerplatz 15, Graz 8036, Austria"}]},{"given":"Markus","family":"Falgenhauer","sequence":"additional","affiliation":[{"name":"Safety and Security Department, AIT Austrian Institute of Technology, Reininghausstr. 13,  Graz 8020, Austria"}]},{"given":"G\u00fcnter","family":"Schreier","sequence":"additional","affiliation":[{"name":"Safety and Security Department, AIT Austrian Institute of Technology, Reininghausstr. 13,  Graz 8020, Austria"}]}],"member":"1968","published-online":{"date-parts":[[2013,8,14]]},"reference":[{"key":"ref_1","unstructured":"Statistik Austria (2011). Jahrbuch der Gesundheitsstatistik 2010, Statistik Austria."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1016\/S0195-668X(02)00700-5","article-title":"The Euroheart failure survey programme\u2014A survey on the quality of care among patients with heart failure in Europe. Part 2: Treatment","volume":"24","author":"Komajda","year":"2003","journal-title":"Eur. Heart J"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1001\/archinte.1997.00440220103013","article-title":"Readmission after hospitalization for congestive heart failure among medicare beneficiaries","volume":"157","author":"Krumholz","year":"1997","journal-title":"Arch. Intern. Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1258\/135763306777889109","article-title":"A systematic review of the literature on home monitoring for patients with heart failure","volume":"12","author":"Martinez","year":"2006","journal-title":"J. Telemed. Telecare"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1161\/CIRCULATIONAHA.112.125435","article-title":"Rehospitalization for heart failure: Predict or prevent?","volume":"126","author":"Desai","year":"2012","journal-title":"Circulation"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1928","DOI":"10.1161\/CIR.0b013e31824f2173","article-title":"Decision making in advanced heart failure\u2014A Scientific statement from the American Heart Association. AHA scientific statement","volume":"125","author":"Allen","year":"2012","journal-title":"Circulation"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"e34","DOI":"10.2196\/jmir.1252","article-title":"MOBITEL Investigators. Effect of home-based telemonitoring using mobile phone technology on the outcome of heart failure patients after an episode of acute decompensation: Randomized controlled trial","volume":"11","author":"Scherr","year":"2009","journal-title":"J. Med. Internet Res."},{"key":"ref_8","unstructured":"Wahlstrand, J.D., and Weijand, K.J. (1998). Implantable Medical System for Performing Transthoracic Impedance Measurements Associated with Cardiac Function. (U.S. Patent 5)."},{"key":"ref_9","unstructured":"Belalcazar, A., Patterson, R., and Shult, R. (2007). Impedance Monitoring for Detecting Pulmonary Edema and Thoracic Congestion. (U.S. Patent 7)."},{"key":"ref_10","unstructured":"Riff, K.M. (1999). Impedance Monitor for Discerning Edema through Evaluation of Respiratory Rate. (U.S. Patent 5)."},{"key":"ref_11","unstructured":"Combs, W.J., Condie, C.R., Martin, R., Wahlstrandl, J.D., and Warkentin, D.H. (1999). Impedance Monitor for Discerning Edema through Evaluation of Respiratory Rate. (U.S. Patent 5)."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1186\/1471-2288-10-5","article-title":"Water displacement leg volumetry in clinical studies\u2014 A discussion of error sources","volume":"10","author":"Rabe","year":"2012","journal-title":"BMC Med. Res. Methol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1726","DOI":"10.1016\/j.jacc.2013.01.052","article-title":"Primary results of the HABIT Trial (Heart Failure Assessment With BNP in the Home)","volume":"61","author":"Maisel","year":"2013","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1007\/978-3-540-73841-1_204","article-title":"Sensitivity of whole-body bioelectrical impedance to edema in one leg","volume":"17","author":"Codognotto","year":"2007","journal-title":"IFMBE Proc."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1016\/j.ahj.2008.10.016","article-title":"Measuring impedance in congestive heart failure: Current options and clinical applications","volume":"157","author":"Tang","year":"2009","journal-title":"Am. Heart J."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1016\/j.clinthera.2012.01.018","article-title":"Segmental bioimpedance for measuring amlodipine-induced pedal edema: A placebo-controlled study","volume":"34","author":"Schoeller","year":"2012","journal-title":"Clin. Ther."},{"key":"ref_17","unstructured":"Schreier, G., Hayn, D., and Ammenwerth, E. (2011, January 26\u201327). Ein neuartiges Messsystem zur Exakten und effizienten Ermittlung des Extremit\u00e4tenvolumnes. Vienna, Austria. Available online: http:\/\/www.ehealth20xx.at\/eHealth2011\/papers\/antonitsch.pdf."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1111\/j.1601-6343.2006.00341.x","article-title":"A new method for the 3D measurement of postoperative swelling following orthognathic surgery","volume":"9","author":"Kau","year":"2006","journal-title":"Orthod. Craniofac. Res."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1016\/j.ijom.2011.02.015","article-title":"3D evaluation of postoperative swelling using two different cooling methods following orthognathic surgery: A randomised observer blind prospective pilot study","volume":"40","author":"Rana","year":"2011","journal-title":"Int. J. Oral. Maxillofac. Surg."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"165","DOI":"10.4338\/ACI-2009-12-RA-0021","article-title":"Innovative telemonitoring systems for cardiology: From science to routine operation","volume":"1","author":"Kastner","year":"2010","journal-title":"Appl. Clin. Inform."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/13\/8\/10584\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:48:38Z","timestamp":1760219318000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/13\/8\/10584"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,8,14]]},"references-count":20,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2013,8]]}},"alternative-id":["s130810584"],"URL":"https:\/\/doi.org\/10.3390\/s130810584","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,8,14]]}}}