{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,14]],"date-time":"2026-03-14T04:20:23Z","timestamp":1773462023353,"version":"3.50.1"},"reference-count":41,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2013,11,28]],"date-time":"2013-11-28T00:00:00Z","timestamp":1385596800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The electrochemical behavior of ascorbic acid and uric acid on glassy carbon bare electrodes and ones modified with \u03b2-cyclodextrin entrapped in polyethyleneimine film has been investigated using square wave voltammetry. The electrode modification was achieved in order to separate the voltammetric peaks of ascorbic acid and uric acid when present in the same solution. On the modified electrodes the potential of the oxidation peak of the ascorbic acid was shifted to more negative values by over 0.3 V, while in the case of uric acid, the negative potential shift was about 0.15 V compared to the bare glassy carbon electrode. When the two compounds were found together in the solution, on the bare electrode only a single broad signal was observed, while on the modified electrode the peak potentials of these two compounds were separated by 0.4 V. When the uric acid concentration remained constant, the peak intensity of the ascorbic acid is increased linearly with the concentration (r2 = 0.996) and when the ascorbic acid concentration remains constant, the peak intensity of the uric acid increased linearly with the concentration (r2 = 0.992). FTIR measurements supported the formation of inclusion complexes. In order to characterize the modification of the electrodes microscopic studies were performed. The modified electrodes were successfully employed for the determination of ascorbic acid in pharmaceutical formulations with a detection limit of 0.22 \u00b5M.<\/jats:p>","DOI":"10.3390\/s131216312","type":"journal-article","created":{"date-parts":[[2013,11,28]],"date-time":"2013-11-28T12:06:47Z","timestamp":1385640407000},"page":"16312-16329","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["New \u03b2-Cyclodextrin Entrapped in Polyethyleneimine  Film-Modified Electrodes for Pharmaceutical  Compounds Determination"],"prefix":"10.3390","volume":"13","author":[{"given":"Lumin\u0163a","family":"Fritea","sequence":"first","affiliation":[{"name":"Analytical Chemistry Department, Faculty of Pharmacy, Iuliu Ha\u0163ieganu University of Medicine and Pharmacy, 4 Pasteur St., Cluj-Napoca 400349, Romania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mihaela","family":"Terti\u015f","sequence":"additional","affiliation":[{"name":"Analytical Chemistry Department, Faculty of Pharmacy, Iuliu Ha\u0163ieganu University of Medicine and Pharmacy, 4 Pasteur St., Cluj-Napoca 400349, Romania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4158-3324","authenticated-orcid":false,"given":"Cecilia","family":"Cristea","sequence":"additional","affiliation":[{"name":"Analytical Chemistry Department, Faculty of Pharmacy, Iuliu Ha\u0163ieganu University of Medicine and Pharmacy, 4 Pasteur St., Cluj-Napoca 400349, Romania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert","family":"S\u0103ndulescu","sequence":"additional","affiliation":[{"name":"Analytical Chemistry Department, Faculty of Pharmacy, Iuliu Ha\u0163ieganu University of Medicine and Pharmacy, 4 Pasteur St., Cluj-Napoca 400349, Romania"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2013,11,28]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/j.electacta.2012.12.026","article-title":"Simultaneous determination of dopamine, ascorbic acid, and uric acid using helical carbon nanotubes modified electrode","volume":"91","author":"Zhang","year":"2013","journal-title":"Electrochim. Acta."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.ab.2008.11.043","article-title":"Determination of nanomolar uric and ascorbic acids using enlarged gold nanoparticles modified electrode","volume":"386","author":"Kannan","year":"2009","journal-title":"Anal. Biochem."},{"key":"ref_3","first-page":"1678","article-title":"Selective electrochemical determination of uric acid in the presence of ascorbic acid using a carbon paste electrode modified with \u03b2-Cyclodextrin","volume":"2","author":"Galicia","year":"2008","journal-title":"Electroanalysis"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1016\/j.snb.2012.03.018","article-title":"A simple strategy based on lanthanum-multiwalled carbon nanotube nanocomposites for simultaneous determination of ascorbic acid, dopamine, uric acid and nitrite","volume":"166\u2013167","author":"Zhang","year":"2012","journal-title":"Sens. Actuators B-Chem."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.ab.2010.01.001","article-title":"Simultaneous determination of catecholamines, uric acid and ascorbic acid at physiological levels using poly(N-methylpyrrole)\/Pd-nanoclusters sensor","volume":"400","author":"Atta","year":"2010","journal-title":"Anal. Biochem."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.aca.2012.06.045","article-title":"Simultaneous determination of ascorbic acid, dopamine, uric acid and tryptophan on gold nanoparticles\/overoxidized-polyimidazole composite modified glassy carbon electrode","volume":"741","author":"Wang","year":"2012","journal-title":"Anal. Chim. Acta"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"6610","DOI":"10.1016\/j.electacta.2008.04.054","article-title":"Electrocatalytic oxidation and simultaneous determination of uric acid and ascorbic acid on the gold nanoparticles-modified glassy carbon electrode","volume":"53","author":"Hu","year":"2008","journal-title":"Electrochimica Acta"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1016\/j.jelechem.2009.06.001","article-title":"A differential pulse voltammetric method for simultaneous determination of ascorbic acid, dopamine, and uric acid using poly (3-(5-chloro-2-hydroxyphenylazo)-4,5-dihydroxynaphthalene-2,7-disulfonic acid) film modified glassy carbon electrode","volume":"633","author":"Ensafi","year":"2009","journal-title":"J. Electroanal. Chem."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1016\/j.snb.2010.06.066","article-title":"Simultaneous determination of ascorbic acid, epinephrine, and uric acid by differential pulse voltammetry using poly(3,3\u2032-bis[N, N-bis(carboxymethyl)aminomethyl]-o-cresolsulfonephthalein) modified glassy carbon electrode","volume":"150","author":"Ensafi","year":"2010","journal-title":"Sens. Actuators B"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.snb.2012.12.115","article-title":"Simultaneous determination of ascorbic acid, dopamine and uric acid using poly(4-aminobutyric acid) modified glassy carbon electrode","volume":"178","author":"Zheng","year":"2013","journal-title":"Sens. Actuators B"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"3450","DOI":"10.1016\/j.bios.2011.01.023","article-title":"The simultaneous electrochemical detection of ascorbic acid, dopamine, and uric acid using graphene\/size-selected Pt nanocomposites","volume":"26","author":"Sun","year":"2011","journal-title":"Biosens. Bioelectron."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/j.bios.2012.01.030","article-title":"Electrochemical sensor based on nitrogen doped graphene: Simultaneous determination of ascorbic acid, dopamine and uric acid","volume":"34","author":"Sheng","year":"2012","journal-title":"Biosens. Bioelectron."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/j.bios.2012.01.016","article-title":"Simultaneous determination of ascorbic acid, dopamine and uric acid using high-performance screen-printed graphene electrode","volume":"34","author":"Ping","year":"2012","journal-title":"Biosens. Bioelectron."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1016\/j.electacta.2012.10.074","article-title":"Modified gold electrodes based on thiocytosine\/guanine-gold nanoparticles for uric and ascorbic acid determination","volume":"88","author":"Vulcu","year":"2013","journal-title":"Electrochimica Acta"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.snb.2010.02.048","article-title":"Highly selective determination of ascorbic acid, dopamine, and uric acid by differential pulse voltammetry using poly(sulfonazo III) modified glassy carbon electrode","volume":"147","author":"Ensafi","year":"2010","journal-title":"Sens. Actuators B"},{"key":"ref_16","first-page":"1132","article-title":"Carbon-nanotube-modified glassy carbon electrode for simultaneous determination of dopamine, ascorbic acid and uric acid: The effect of functional groups","volume":"171\u2013172","author":"Huaqing","year":"2012","journal-title":"Sens. Actuators B"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"754","DOI":"10.1016\/j.talanta.2011.04.064","article-title":"Electrochemical response of ascorbic and uric acids at organoclay film modified glassy carbon electrodes and sensing applications","volume":"85","author":"Mbouguena","year":"2011","journal-title":"Talanta"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"2344","DOI":"10.1016\/j.talanta.2011.07.067","article-title":"Selective detection of dopamine in the presence of uric acid using a gold nanoparticles-poly(luminol) hybrid film and multi-walled carbon nanotubes with incorporated \u03b2-cyclodextrin modified glassy carbon electrode","volume":"85","author":"Jia","year":"2011","journal-title":"Talanta"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.talanta.2012.01.047","article-title":"Simultaneous determination of l-ascorbic acid, dopamine and uric acid with gold nanoparticles-\u03b2-cyclodextrin-graphene-modified electrode by square wave voltammetry","volume":"93","author":"Tian","year":"2012","journal-title":"Talanta"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.jelechem.2011.12.020","article-title":"Simultaneous electrochemical detection of the catecholamines and ascorbic acid at PEDOT\/S-\u03b2-CD modified gold electrodes","volume":"667","author":"Colleran","year":"2012","journal-title":"J. Electroanal. Chem."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1776","DOI":"10.1016\/j.bios.2008.02.012","article-title":"Selective detection of uric acid in the presence of ascorbic acid at physiological pH by using a \u03b2-cyclodextrin modified copolymer of sulfanilic acid and N-acetylaniline","volume":"23","author":"Wu","year":"2008","journal-title":"Biosens. Bioelectron."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"74","DOI":"10.2174\/1875038901003010074","article-title":"Electrochemistry of cyclodextrin inclusion complexes of pharmaceutical compounds","volume":"3","author":"Shimaa","year":"2010","journal-title":"Open Chem. Biomed. Methods J."},{"key":"ref_23","unstructured":"Fritea, L., Terti\u015f, M., Topal\u0103, T.L., and S\u0103ndulescu, R. (2013). Electroanalytical study of cyclodextrins interactions with some pharmaceutical compounds. Farmacia, 61, accepted."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s002160100752","article-title":"Cyclodextrins as electrode modifiers","volume":"370","author":"Labuda","year":"2001","journal-title":"Fresenius J. Anal. Chem."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"909","DOI":"10.1016\/j.snb.2011.01.041","article-title":"Per-6-ammonium-\u03b2 -cyclodextrin\/p-nitrophenol complex as a colorimetric sensor for phosphate and pyrophosphate anions in water","volume":"155","author":"Azath","year":"2011","journal-title":"Sens. Actuators B"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"2145","DOI":"10.1002\/elan.201300304","article-title":"Fullerene-\u03b2-cyclodextrin conjugate based electrochemical sensing device for ultrasensitive detection of p-nitrophenol","volume":"25","author":"Rather","year":"2013","journal-title":"Electroanalysis"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/j.bios.2010.06.036","article-title":"Electrochemical biosensing platforms using poly-cyclodextrin and carbon nanotube composite","volume":"26","author":"Yang","year":"2010","journal-title":"Biosens. Bioelectron."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/j.electacta.2012.02.045","article-title":"Metal platinum-wrapped mesoporous carbon for sensitive electrochemical immunosensing based on cyclodextrin functionalized graphene nanosheets","volume":"68","author":"Zeng","year":"2012","journal-title":"Electrochim. Acta"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1016\/j.snb.2010.09.012","article-title":"The selective detection of dopamine at a polypyrrole film doped with sulfonated b-cyclodextrins","volume":"150","author":"Harley","year":"2010","journal-title":"Sens. Actuators B"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1768","DOI":"10.1016\/j.bios.2010.08.058","article-title":"Enzyme entrapment by \u03b2-cyclodextrin electropolymerization onto a carbon nanotubes-modified screen-printed electrode","volume":"26","author":"Guix","year":"2010","journal-title":"Biosens. Bioelectron."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/j.jcis.2012.07.050","article-title":"Supramolecular immobilization of redox enzymes on cyclodextrin-coated magnetic nanoparticles for biosensing applications","volume":"386","author":"Villalonga","year":"2012","journal-title":"J. Colloid Interface Sci."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.colsurfb.2012.05.003","article-title":"\u03b2-cyclodextrin-cobalt ferrite nanocomposite as enhanced sensing platform for catechol determination","volume":"98","author":"Han","year":"2012","journal-title":"Colloids Surf. B Biointerfaces"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"4674","DOI":"10.1016\/j.bios.2011.04.061","article-title":"A cyclodextrin host\u2013guest recognition approach to an electrochemical sensor for simultaneous quantification of serotonin and dopamine","volume":"26","author":"Abbaspour","year":"2011","journal-title":"Biosens. Bioelectron."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1016\/j.snb.2011.01.022","article-title":"Biocompatible hybrid film of \u03b2-cyclodextrin and ionic liquids: A novel platform for electrochemical biosensing","volume":"155","author":"Cao","year":"2011","journal-title":"Sens. Actuators B"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1016\/j.biotechadv.2011.09.003","article-title":"Immobilization strategies to develop enzymatic biosensors","volume":"30","author":"Sassolas","year":"2012","journal-title":"Biotechnol. Adv."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.1016\/j.jpba.2008.08.018","article-title":"Electroanalytical properties of a novel biosensor modified with zirconium alcoxide porous gels for the detection of acetaminophen","volume":"48","author":"Sima","year":"2008","journal-title":"J. Pharm. Biomed. Anal."},{"key":"ref_37","first-page":"1034","article-title":"Screen-printed electrodes modified with HRP-zirconium alcoxide film for the development of a biosensor for acetaminophen detection","volume":"8","author":"Sima","year":"2010","journal-title":"Cent. Eur. J. Chem."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1016\/j.snb.2007.11.056","article-title":"An inlaying ultra-thin carbon paste electrode modified with functional single-wall carbon nanotubes for simultaneous determination of three purine derivatives","volume":"131","author":"Wang","year":"2008","journal-title":"Sens. Actuators B: Chem."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"4841","DOI":"10.3390\/s130404841","article-title":"Carbon based Electrodes modified with Horseradish Peroxidase immobilized in conducting polymers for acetaminophen analysis","volume":"13","author":"Florea","year":"2013","journal-title":"Sensors"},{"key":"ref_40","unstructured":"(2008). Farmacopeea Rom\u00e2n\u0103, Medical\u0103. [10th ed.]."},{"key":"ref_41","unstructured":"(2011). European Pharmacopoeia, EQCM. [7th ed.]."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/13\/12\/16312\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:50:57Z","timestamp":1760219457000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/13\/12\/16312"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,11,28]]},"references-count":41,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2013,12]]}},"alternative-id":["s131216312"],"URL":"https:\/\/doi.org\/10.3390\/s131216312","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,11,28]]}}}