{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:26:57Z","timestamp":1760243217665,"version":"build-2065373602"},"reference-count":37,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2014,1,24]],"date-time":"2014-01-24T00:00:00Z","timestamp":1390521600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The correct choice and customization of an orthosis are crucial to obtain the best comfort and efficiency. This study explored the feasibility of a multivariate quantitative assessment of the functional efficiency of lower limb orthosis through a novel wearable system. Gait basographic parameters and energetic indexes were analysed during a  Six-Minute Walking Test (6-MWT) through a cost-effective, non-invasive polygraph device, with a multichannel wireless transmission, that carried out electro-cardiograph (ECG); impedance-cardiograph (ICG); and lower-limb accelerations detection. Four subjects affected by Post-Polio Syndrome (PPS) were recruited. The wearable device and the semi-automatic post-processing software provided a novel set of objective data to assess the overall efficiency of the patient-orthosis system. Despite the small number of examined subjects, the results obtained with this new approach encourage the application of the method thus enlarging the dataset to validate this promising protocol and measuring system in supporting clinical decisions and out of a laboratory environment.<\/jats:p>","DOI":"10.3390\/s140202012","type":"journal-article","created":{"date-parts":[[2014,1,24]],"date-time":"2014-01-24T11:30:50Z","timestamp":1390563050000},"page":"2012-2027","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Wearable Monitoring Devices for Assistive Technology: Case Studies in Post-Polio Syndrome"],"prefix":"10.3390","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5537-4128","authenticated-orcid":false,"given":"Giuseppe","family":"Andreoni","sequence":"first","affiliation":[{"name":"Design Department, Politecnico di Milano, via G. Durando 38\/A, Milan 20158, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marco","family":"Mazzola","sequence":"additional","affiliation":[{"name":"Design Department, Politecnico di Milano, via G. Durando 38\/A, Milan 20158, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4960-8888","authenticated-orcid":false,"given":"Paolo","family":"Perego","sequence":"additional","affiliation":[{"name":"Design Department, Politecnico di Milano, via G. Durando 38\/A, Milan 20158, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlo","family":"Standoli","sequence":"additional","affiliation":[{"name":"Design Department, Politecnico di Milano, via G. Durando 38\/A, Milan 20158, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simone","family":"Manzoni","sequence":"additional","affiliation":[{"name":"Design Department, Politecnico di Milano, via G. Durando 38\/A, Milan 20158, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luca","family":"Piccini","sequence":"additional","affiliation":[{"name":"SXT-Sistemi per Telemedicina s.r.l., via M. D'Oggiono 18\/A, Lecco 23900, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Franco","family":"Molteni","sequence":"additional","affiliation":[{"name":"Villa Beretta\" Rehabilitation Center, Valduce Hospital, Via N.Sauro,  17 - 23845 Costa Masnaga (LC), Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2014,1,24]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1314","DOI":"10.1136\/bmj.330.7503.1314","article-title":"Poliomyelitis and the postpolio syndrome","volume":"330","author":"Howard","year":"2005","journal-title":"BMJ"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"877","DOI":"10.3928\/0147-7447-19850701-11","article-title":"Polio: Long-term problems","volume":"8","author":"Perry","year":"1985","journal-title":"Orthop"},{"key":"ref_3","first-page":"171","article-title":"Knee-ankle-foot orthosis for poliomyelitis sequelae. Structural and technical evolution","volume":"37","author":"Conil","year":"2001","journal-title":"Eur. Medicophys."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Perry, J. (1992). Gait Analysis, Normal and Pathological Function, Slack Inc.. [2nd ed.].","DOI":"10.1097\/01241398-199211000-00023"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1097\/00008526-200401000-00004","article-title":"Preliminary evidence for effectiveness of a stance control orthosis","volume":"16","author":"McMillan","year":"2004","journal-title":"J. Prosthetics Orthot."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"896","DOI":"10.2106\/00004623-198264060-00013","article-title":"Energy cost of walking in lower extremity plaster casts","volume":"64","author":"Waters","year":"1982","journal-title":"J. Bone Joint Surg."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1097\/00008526-199600830-00003","article-title":"Energy-efficient knee-ankle foot orthosis: A case study","volume":"8","author":"Kaufman","year":"1996","journal-title":"J. Prosthetics Orthot."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1109\/86.769402","article-title":"Optimization and application of a wrap-spring clutch to a dynamic knee-ankle-foot orthosis","volume":"7","author":"Irby","year":"1999","journal-title":"IEEE Trans. Rehabil. Eng"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/S0966-6362(99)00009-0","article-title":"The energy expenditure of normal and pathologic gait","volume":"9","author":"Waters","year":"1999","journal-title":"Gait Posture"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1109\/86.769403","article-title":"Automatic control design for a dynamic knee-brace system","volume":"7","author":"Irby","year":"1999","journal-title":"IEEE Trans. Rehabil. Eng."},{"key":"ref_11","unstructured":"Yakimovich, T., Lemaire, E.D., and Kofman, J. (September, January 30). Gait Evaluation of a New Electromechanical Stance-Control Knee-Ankle-Foot Orthosis. New York, NY, USA."},{"key":"ref_12","unstructured":"Muik, E., Davis, R., Tyburskiz, D., and Fezio, J. (November, January 31). The Design and Development of an Orthotic Evaluation System. Orlando, FL, USA."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.bspc.2007.09.001","article-title":"Human motion tracking for rehabilitation\u2014A survey","volume":"3","author":"Zhou","year":"2008","journal-title":"Biomed. Signal Process. Control"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1186\/1743-0003-2-2","article-title":"Advances in wearable technology and applications in physical medicine and rehabilitation","volume":"2","author":"Bonato","year":"2005","journal-title":"J. NeuroEng. Rehabilit."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1007\/BF02513304","article-title":"Physical activity monitoring based on accelerometry: Validation and comparison with video observation","volume":"37","author":"Aminian","year":"1999","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_16","first-page":"25","article-title":"The importance of technology in rehabilitation","volume":"22","author":"Frontera","year":"2003","journal-title":"IEEE Eng. Med. Biol."},{"key":"ref_17","unstructured":"Stott, F.D., Raftery, E.B., and Goulding, L. The Objective Measurement of Physical Performance with Long Term Ambulatory Physiological Surveillance Equipment. London, UK."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1266","DOI":"10.1053\/apmr.2002.34598","article-title":"A new method of using heart rate to represent energy expenditure: The Total Heart Beat Index","volume":"83","author":"Hood","year":"2002","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_19","first-page":"1208","article-title":"Development and evaluation of an impedance cardiac output system","volume":"37","author":"Kubicek","year":"1966","journal-title":"Aerosp. Med."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"904","DOI":"10.1097\/00003246-198610000-00017","article-title":"A new stroke volume equation for thoracic electrical bioimpedance: Theory and rationale","volume":"14","author":"Bernstein","year":"1986","journal-title":"Crit. Care Med."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1007\/BF02510508","article-title":"Comparison between spot and band electrodes and between two equations for calculation of stroke volume by means of impedance cardiograph","volume":"33","author":"Woltjer","year":"1995","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1378\/chest.123.2.387","article-title":"The 6-min Walk Test. A quick measure of functional status in elderly adults","volume":"123","author":"Enright","year":"2003","journal-title":"Chest"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.knee.2008.10.002","article-title":"Walking shoes and laterally wedged orthosis in the clinical management of medial tibiofemoral osteoarthritis: A one-year prospective controlled trial","volume":"16","author":"Barrios","year":"2009","journal-title":"The Knee"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1016\/S0268-0033(98)00090-4","article-title":"A new method for evaluating motor control in gait under real-life environmental conditions. Part 2: Gait analysis","volume":"13","year":"1998","journal-title":"Clin. Biomech."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1109\/TBME.1985.325532","article-title":"A real-time QRS detection algorithm","volume":"32","author":"Pan","year":"1985","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1109\/TBME.1986.325695","article-title":"Quantitative investigation of QRS detection rules using the MIT\/BIH arythmia database","volume":"33","author":"Hamilton","year":"1986","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1396","DOI":"10.1093\/oxfordjournals.eurheartj.a015464","article-title":"The technique of impedance cardiograph","volume":"18","author":"Woltjer","year":"1997","journal-title":"Eur. Heart J."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1007\/BF02344724","article-title":"Stroke volume equation for impedance cardiograph","volume":"43","author":"Bernstein","year":"2005","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1109\/TIM.2009.2025065","article-title":"Reducing drifts in the inertial measurements of wrist and elbow positions","volume":"59","author":"Zhou","year":"2010","journal-title":"IEEE T. Instrum. Meas."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/j.medengphy.2006.11.010","article-title":"Use of multiple wearable inertial sensors in upper limb motion tracking","volume":"30","author":"Zhou","year":"2008","journal-title":"Med. Eng. Phys."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/S0966-6362(01)00200-4","article-title":"Trunk accelerometry as a measure of balance control during quiet standing","volume":"16","author":"Helbostad","year":"2002","journal-title":"Gait Posture"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/S0021-9290(03)00233-1","article-title":"Estimation of gait cycle characteristics by trunk accelerometry","volume":"37","author":"Helbostad","year":"2004","journal-title":"J. Biomech."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1080\/00140136008930473","article-title":"The energy expenditure and mechanical energy demand in walking","volume":"3","author":"Cotes","year":"1960","journal-title":"Ergonomics"},{"key":"ref_34","unstructured":"Ismail, A.H., Barany, J.W., and Smith, C.B. (1970, January 19\u201320). Relationships between Mechanical Force and Physiological Cost during Gait in Adult Man. Bloomington,IN, USA."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1516","DOI":"10.1249\/00005768-199412000-00016","article-title":"Assessment of energy expenditure for physical activity using a triaxial accelerometer","volume":"26","author":"Bouten","year":"1994","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"2041","DOI":"10.1016\/j.apmr.2005.04.022","article-title":"The reliability and validity of the physiological cost index in healthy subjects while walking on 2 different tracks","volume":"86","author":"Graham","year":"2005","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1002\/jor.1100060208","article-title":"Energy\u2013speed relationship of walking: Standard tables","volume":"6","author":"Waters","year":"1988","journal-title":"J. Orthop Res."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/2\/2012\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:07:39Z","timestamp":1760216859000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/2\/2012"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,1,24]]},"references-count":37,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2014,2]]}},"alternative-id":["s140202012"],"URL":"https:\/\/doi.org\/10.3390\/s140202012","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2014,1,24]]}}}