{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T15:40:49Z","timestamp":1790437249695,"version":"4.1.0"},"reference-count":29,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2014,1,24]],"date-time":"2014-01-24T00:00:00Z","timestamp":1390521600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The emergence of wireless sensor networks (WSNs) has motivated a paradigm shift in patient monitoring and disease control. Epilepsy management is one of the areas that could especially benefit from the use of WSN. By using miniaturized wireless electroencephalogram (EEG) sensors, it is possible to perform ambulatory EEG recording and real-time seizure detection outside clinical settings. One major consideration in using such a wireless EEG-based system is the stringent battery energy constraint at the sensor side. Different solutions to reduce the power consumption at this side are therefore highly desired. The conventional approach incurs a high power consumption, as it transmits the entire EEG signals wirelessly to an external data server (where seizure detection is carried out). This paper examines the use of data reduction techniques for reducing the amount of data that has to be transmitted and, thereby, reducing the required power consumption at the sensor side. Two data reduction approaches are examined: compressive sensing-based EEG compression and low-complexity feature extraction. Their performance is evaluated in terms of seizure detection effectiveness and power consumption. Experimental results show that by performing low-complexity feature extraction at the sensor side and transmitting only the features that are pertinent to seizure detection to the server, a considerable overall saving in power is achieved. The battery life of the system is increased by 14 times, while the same seizure detection rate as the conventional approach (95%) is maintained.<\/jats:p>","DOI":"10.3390\/s140202036","type":"journal-article","created":{"date-parts":[[2014,1,24]],"date-time":"2014-01-24T11:30:50Z","timestamp":1390563050000},"page":"2036-2051","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":33,"title":["Energy-Efficient Data Reduction Techniques for Wireless Seizure Detection Systems"],"prefix":"10.3390","volume":"14","author":[{"given":"Joyce","family":"Chiang","sequence":"first","affiliation":[{"name":"Department of Electrical and Computer Engineering, The University of British Columbia, 2332 Main Mall, Vancouver, BC V6T 1Z4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rabab","family":"Ward","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, The University of British Columbia, 2332 Main Mall, Vancouver, BC V6T 1Z4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2014,1,24]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Engel, J. (2013). Seizures and Epilepsy, Oxford University Press.","DOI":"10.1093\/med\/9780195328547.001.0001"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/S0920-1211(00)00126-1","article-title":"The impact of epilepsy from the patients perspective I. Descriptions and subjective perceptions","volume":"41","author":"Fisher","year":"2000","journal-title":"Epilepsy Res."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1109\/10.552241","article-title":"A patient-specific algorithm for the detection of seizure onset in long-term EEG monitoring: Possible use as a warning device","volume":"44","author":"Qu","year":"1997","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1109\/TBME.2003.810705","article-title":"Epileptic seizure prediction and control","volume":"50","author":"Iasemidis","year":"2003","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1109\/TBME.2006.886855","article-title":"A wavelet-chaos methodology for analysis of EEGs and EEG subbands to detect seizure and epilepsy","volume":"54","author":"Adeli","year":"2007","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1007\/s11517-012-0904-x","article-title":"Optimal features for online seizure detection","volume":"50","author":"Logesparan","year":"2012","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1038\/ncpneuro0750","article-title":"Technology insight: Neuroengineering and epilepsy-designing devices for seizure control","volume":"4","author":"Stacey","year":"2008","journal-title":"Nat. Clin. Practice Neurol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1313","DOI":"10.1016\/j.mejo.2008.08.015","article-title":"Ultra-low-power biopotential interfaces and their applications in wearable and implantable systems","volume":"40","author":"Yazicioglu","year":"2009","journal-title":"Microelectron. J."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2816","DOI":"10.1109\/TBME.2009.2027607","article-title":"Toward online data reduction for portable electroencephalography systems in epilepsy","volume":"56","author":"Casson","year":"2009","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1206","DOI":"10.1016\/j.cmpb.2012.06.005","article-title":"Dynamic, location-based channel selection for power consumption reduction in EEG analysis","volume":"108","author":"Faul","year":"2012","journal-title":"Comput. Methods Progr. Biomed."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1109\/10.552239","article-title":"EEG data compression techniques","volume":"44","author":"Antoniol","year":"1997","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1109\/JETCAS.2012.2214635","article-title":"A nonuniform sampler for wideband spectrally-sparse environments","volume":"2","author":"Wakin","year":"2012","journal-title":"IEEE J. Emerg. Sel. Top. Circuits Syst."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1109\/JETCAS.2012.2221832","article-title":"A low-power compressive sampling time-based analog-to-digital converter","volume":"2","author":"Yenduri","year":"2012","journal-title":"IEEE J. Emerg. Sel. Top. Circuits Syst."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"2456","DOI":"10.1109\/TBME.2011.2156795","article-title":"Compressed sensing for real-time energy-efficient ECG compression on wireless body sensor nodes","volume":"58","author":"Mamaghanian","year":"2011","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1109\/TBME.2012.2217959","article-title":"Compressed sensing of EEG for wireless telemonitoring with low energy consumption and inexpensive hardware","volume":"60","author":"Zhang","year":"2013","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_16","unstructured":"Esteller, R., Echauz, J., Tcheng, T., Litt, B., and Pless, B. (2001, January 25\u201328). Line Length: An Efficient Feature for Seizure Onset Detection. Istanbul, Turkey."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/j.jneumeth.2005.09.014","article-title":"Efficient unsupervised algorithms for the detection of seizures in continuous EEG recordings from rats after brain injury","volume":"152","author":"White","year":"2006","journal-title":"J. Neurosc. Methods"},{"key":"ref_18","unstructured":"Shoeb, A.H. (2009). Application of Machine Learning to Epileptic Seizure onset Detection and Treatment. [Ph.D. Thesis, Massachusetts Institute of Technology]."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1111\/1469-8986.3720163","article-title":"Removing electroencephalographic artifacts by blind source separation","volume":"37","author":"Jung","year":"2000","journal-title":"Psychophysiology"},{"key":"ref_20","unstructured":"Shoeb, A., and Guttag, J. (2010, January 21\u201324). Application of Machine Learning to Epileptic Seizure Detection. Haifa, Israel."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1023\/A:1009715923555","article-title":"A tutorial on support vector machines for pattern recognition","volume":"2","author":"Burges","year":"1998","journal-title":"Data Min. Knowl. Discov."},{"key":"ref_22","unstructured":"Titzer, B.L., Lee, D.K., and Palsberg, J. (2005, January 25\u201327). Avrora: Scalable Sensor Network Simulation with Precise Timing. Los Angeles, CA, USA."},{"key":"ref_23","unstructured":"Levis, P., Madden, S., Polastre, J., Szewczyk, R., Whitehouse, K., Woo, A., Gay, D., Hill, J., Welsh, M., and Brewer, E. (2005). Ambient Intelligence, Springer."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Hunyadi, B., Signoretto, M., van Paesschen, W., Suykens, J.A., van Huffel, S., and de Vos, M. (2012). Incorporating structural information from the multichannel EEG improves patient-specific seizure detection. Clin. Neurophysiol., 2352\u20132361.","DOI":"10.1016\/j.clinph.2012.05.018"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Lorincz, K., Chen, B.R., Challen, G.W., Chowdhury, A.R., Patel, S., Bonato, P., and Welsh, M. (2009). Mercury: A wearable sensor network platform for high-fidelity motion analysis. SenSys, 183\u2013196.","DOI":"10.1145\/1644038.1644057"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1016\/j.clinph.2005.10.006","article-title":"Automated neonatal seizure detection: A multistage classification system through feature selection based on relevance and redundancy analysis","volume":"117","author":"Aarabi","year":"2006","journal-title":"Clin. Neurophysiol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2480","DOI":"10.1016\/j.clinph.2005.06.017","article-title":"Detecting temporal lobe seizures from scalp EEG recordings: A comparison of various features","volume":"116","author":"Kind","year":"2005","journal-title":"Clin. Neurophysiol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/j.cmpb.2005.04.006","article-title":"Epileptic seizure detection: A nonlinear viewpoint","volume":"79","author":"Lammi","year":"2005","journal-title":"Comput. Methods Progr. Biomed."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1248","DOI":"10.1016\/j.clinph.2008.02.001","article-title":"A comparison of quantitative EEG features for neonatal seizure detection","volume":"119","author":"Greene","year":"2008","journal-title":"Clin. Neurophysiol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/2\/2036\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:07:39Z","timestamp":1760216859000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/2\/2036"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,1,24]]},"references-count":29,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2014,2]]}},"alternative-id":["s140202036"],"URL":"https:\/\/doi.org\/10.3390\/s140202036","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,1,24]]}}}