{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T15:53:17Z","timestamp":1792252397486,"version":"4.4.0"},"reference-count":19,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2014,2,19]],"date-time":"2014-02-19T00:00:00Z","timestamp":1392768000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The paper presents a set of tests carried out in order to evaluate the design characteristics and the operating performance of a set of six X-ray extrinsic optical fiber sensors. The extrinsic sensor we developed is intended to be used as a low energy X-ray detector for monitoring radiation levels in radiotherapy, industrial applications and  for personnel dosimetry. The reproducibility of the manufacturing process and the characteristics of the sensors were assessed. The sensors dynamic range, linearity, sensitivity, and reproducibility are evaluated through radioluminescence measurements,  X-ray fluorescence and X-ray imaging investigations. Their response to the operating conditions of the excitation source was estimated. The effect of the sensors design and implementation, on the collecting efficiency of the radioluminescence signal was measured. The study indicated that the sensors are efficient only in the first 5 mm of the tip, and that a reflective coating can improve their response. Additional tests were done to investigate the concentricity of the sensors tip against the core of the optical fiber guiding the optical signal. The influence of the active material concentration on the sensor response to X-ray was studied. The tests were carried out by measuring the radioluminescence signal with an optical fiber spectrometer and with a Multi-Pixel Photon Counter.<\/jats:p>","DOI":"10.3390\/s140203445","type":"journal-article","created":{"date-parts":[[2014,2,19]],"date-time":"2014-02-19T11:10:21Z","timestamp":1392808221000},"page":"3445-3457","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Characterization of Scintillating X-ray Optical Fiber Sensors"],"prefix":"10.3390","volume":"14","author":[{"given":"Dan","family":"Sporea","sequence":"first","affiliation":[{"name":"National Institute Laser, Plasma and Radiation Physics, 409 Atomi\u015ftilor St., M\u0103gurele RO-077125, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3869-1890","authenticated-orcid":false,"given":"Laura","family":"Mihai","sequence":"additional","affiliation":[{"name":"National Institute Laser, Plasma and Radiation Physics, 409 Atomi\u015ftilor St., M\u0103gurele RO-077125, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ion","family":"V\u00e2\u0163\u0103","sequence":"additional","affiliation":[{"name":"Horia Hulubei\" National Institute of Physics and Nuclear Engineering, 30 Reactorului St., M\u0103gurele RO-077125, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Denis","family":"McCarthy","sequence":"additional","affiliation":[{"name":"Optical Fibre Sensors Research Centre, ECE Department, University of Limerick, Limerick, Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sinead","family":"O'Keeffe","sequence":"additional","affiliation":[{"name":"Optical Fibre Sensors Research Centre, ECE Department, University of Limerick, Limerick, Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4174-7090","authenticated-orcid":false,"given":"Elfed","family":"Lewis","sequence":"additional","affiliation":[{"name":"Optical Fibre Sensors Research Centre, ECE Department, University of Limerick, Limerick, Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2014,2,19]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Yasin, M., Harun, S.W., and Arof, H. (2012). Selected Topics on Optical Fiber Technology, InTech.","DOI":"10.5772\/2429"},{"key":"ref_2","unstructured":"Brichard, B., and Fernandez Fernandez, A. (2005). Short Course Notebook, New Challenges for Radiation Tolerance Assessment, RADECS Association, Universit \u00e9 Montpellier."},{"key":"ref_3","unstructured":"Intermite, A., Putignano, M., and Welsch, C.P. (2009, January 25\u201327). Feasibility Study of an Optical Fiber Sensor for Beam Loss Detection Based on a SPAD Array. Basel, Switzerland."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"765","DOI":"10.3938\/jkps.56.765","article-title":"Measurement of Cerenkov light in a fiber-optic radiation sensor by using high-energy photon and electron beams","volume":"56","author":"Jang","year":"2010","journal-title":"J. Korean Phys. Soc."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"A531","DOI":"10.1103\/PhysRev.133.A531","article-title":"Ionization expansion of compacted silica and the theory of radiation-induced dilatations in vitreous silica","volume":"133","author":"Primak","year":"1964","journal-title":"Phys. Rev."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1088\/0957-0233\/17\/5\/S25","article-title":"The effects of gamma-radiation on the properties of Brillouin scattering in standard Ge doped optical fibres","volume":"17","author":"Alasia","year":"2006","journal-title":"Meas. Sci. Technol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1428","DOI":"10.1109\/LPT.2003.818247","article-title":"In situ measurement of refractive index changes induced by gamma radiation in germanosilicate fibers","volume":"15","author":"Brichard","year":"2003","journal-title":"IEEE Photonic Technol. Lett."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/j.nima.2011.02.041","article-title":"Electron irradiation response on Ge and Al-doped SiO2 optical fibres","volume":"A637","author":"Yaakob","year":"2011","journal-title":"Nucl. Instrum. Method Phys. Res."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1259\/bjr\/22554286","article-title":"In vivo absorbed dose measurements in mammography using a new real-time luminescence technique","volume":"78","author":"Aznar","year":"2005","journal-title":"Brit. J. Radiol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"708","DOI":"10.1118\/1.3063006","article-title":"Characterization of a fiber-coupled Al2O3:C luminescence dosimetry system for online in vivo dose verification during 192Ir brachytherapy","volume":"36","author":"Andersen","year":"2009","journal-title":"Med. Phys."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"929","DOI":"10.1016\/j.radmeas.2007.02.042","article-title":"A fibre optic dosimeter customised for brachytherapy","volume":"42","author":"Suchowerska","year":"2007","journal-title":"Radiat. Meas."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1007\/s10043-009-0072-x","article-title":"Characterization of a scintillating fiber-optic dosimeter for photon beam therapy","volume":"16","author":"Jang","year":"2009","journal-title":"Opt. Rev."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"186","DOI":"10.15669\/pnst.1.186","article-title":"Test of a fiber optic scintillation dosimeter with BGO tip in a 60Co irradiation chamber","volume":"1","author":"Seo","year":"2011","journal-title":"Prog. Nucl. Sci. Technol."},{"key":"ref_14","unstructured":"Phosphor Technology Ltd Data Sheets, Phosphor Technology Ltd. UKL65\/FR1 X-ray Phosphor. Available online: http:\/\/www.phosphor-technology.com."},{"key":"ref_15","unstructured":"Sporea, D., Sporea, A., O'Keeffe, S., McCarthy, D., and Lewis, E. (2013). Radiation dosimeter using an extrinsic fiber optic sensor. IEEE Sens. J."},{"key":"ref_16","unstructured":"AMPTEK Inc. Miniature X-Ray Source, Mini-X. Available online: http:\/\/www.amptek.com\/pdf\/minixoem.pdf."},{"key":"ref_17","unstructured":"AMPTEK Inc. Silicon Drift Detectors (SDD) X-123SDD. Available online: http:\/\/www.amptek.com\/pdf\/sdd.pdf."},{"key":"ref_18","unstructured":"Ocean Optics, QE65000 Data Sheet. Available online: http:\/\/www.oceanoptics.com\/technical\/engineering\/OEM%20Data%20Sheet%20--%20QE65000.pdf."},{"key":"ref_19","unstructured":"Hamamatsu Photon Counting Module with Built-in MPPC. Available online: http:\/\/www.electronicsdatasheets.com\/download\/114924.pdf?format=pdf."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/2\/3445\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:08:18Z","timestamp":1760216898000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/2\/3445"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,2,19]]},"references-count":19,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2014,2]]}},"alternative-id":["s140203445"],"URL":"https:\/\/doi.org\/10.3390\/s140203445","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,2,19]]}}}