{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,8]],"date-time":"2025-11-08T22:41:22Z","timestamp":1762641682543,"version":"build-2065373602"},"reference-count":17,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2014,4,22]],"date-time":"2014-04-22T00:00:00Z","timestamp":1398124800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>It is difficult to accurately measure the volume of transdermally extracted interstitial fluid (ISF), which is important for improving blood glucose prediction accuracy. Skin resistance, which is a good indicator of skin permeability, can be used to determine the volume of extracted ISF. However, it is a challenge to realize in vivo longitudinal  skin resistance measurements of microareas. In this study, a three-electrode sensor was presented for measuring single-point skin resistance in vivo, and a method for determining the volume of transdermally extracted ISF using this sensor was proposed. Skin resistance was measured under static and dynamic conditions. The correlation between the skin resistance and the permeation rate of transdermally extracted ISF was proven. The volume of transdermally extracted ISF was determined using skin resistance. Factors affecting the volume prediction accuracy of transdermally extracted ISF were discussed. This method is expected to improve the accuracy of blood glucose prediction, and is of great significance for the clinical application of minimally invasive blood glucose measurement.<\/jats:p>","DOI":"10.3390\/s140407084","type":"journal-article","created":{"date-parts":[[2014,4,22]],"date-time":"2014-04-22T12:18:37Z","timestamp":1398169117000},"page":"7084-7095","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["A Method for Measuring the Volume of Transdermally Extracted Interstitial Fluid by a Three-Electrode Skin  Resistance Sensor"],"prefix":"10.3390","volume":"14","author":[{"given":"Dachao","family":"Li","sequence":"first","affiliation":[{"name":"State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University,  Tianjin 300072, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ridong","family":"Wang","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University,  Tianjin 300072, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haixia","family":"Yu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University,  Tianjin 300072, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guoqing","family":"Li","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University,  Tianjin 300072, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yue","family":"Sun","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University,  Tianjin 300072, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenshuai","family":"Liang","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University,  Tianjin 300072, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kexin","family":"Xu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University,  Tianjin 300072, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2014,4,22]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1089\/dia.2008.0044","article-title":"Graphical and Numerical Evaluation of Continuous Glucose Sensing Time Lag","volume":"11","author":"Kovatchev","year":"2009","journal-title":"Diabetes Technol. Ther."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1540","DOI":"10.1177\/193229681000400632","article-title":"Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises","volume":"4","author":"Vaddiraju","year":"2010","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.aca.2012.03.043","article-title":"Non-invasive glucose monitoring technology in diabetes management: A review","volume":"750","author":"Vashist","year":"2012","journal-title":"Anal. Chim. Acta"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"770","DOI":"10.1089\/dia.2005.7.770","article-title":"A review of continuous glucose monitoring technology","volume":"7","author":"Klonoff","year":"2005","journal-title":"Diabetes Technol. Ther."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1016\/j.jconrel.2012.08.019","article-title":"Rapid skin permeabilization by the simultaneous application of dual-frequency, high-intensity ultrasound","volume":"163","author":"Schoellhammer","year":"2012","journal-title":"J. Control. Release"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1038\/73213","article-title":"Transdermal monitoring of glucose and other analytes using ultrasound","volume":"6","author":"Kost","year":"2000","journal-title":"Nat. Med."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"917","DOI":"10.1109\/JMEMS.2012.2192910","article-title":"An ISF transdermal extraction system for continuous glucose monitoring","volume":"21","author":"Yu","year":"2012","journal-title":"J. Microelectromech. Syst."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1088\/0960-1317\/22\/3\/035010","article-title":"Design, fabrication and testing of a micro-Venturi tube for fluid manipulation in a microfluidic system","volume":"22","author":"Yu","year":"2012","journal-title":"J. Micromech. Microeng."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/S0168-3659(99)00178-9","article-title":"Determination of threshold energy dose for ultrasound-induced transdermal drug transport","volume":"63","author":"Mitragotri","year":"2000","journal-title":"J. Control. Release"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1109\/TBME.2007.893472","article-title":"Utilizing Characteristic Electrical Properties of the Epidermal Skin Layers to Detect Fake Fingers in Biometric Fingerprint Systems\u2014A Pilot Study","volume":"54","author":"Martinsen","year":"2007","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1093\/ecam\/nem060","article-title":"Skin Impedance Measurements for Acupuncture Research: Development of a Continuous Recording System","volume":"5","author":"Colbert","year":"2008","journal-title":"Evid. Based Complement. Altern. Med."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1007\/BF02525528","article-title":"Fast in vivo measurements of local tissue impedances using needle electrodes","volume":"35","author":"Kinouchi","year":"1997","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2697","DOI":"10.1007\/s11095-008-9696-y","article-title":"Screening of Chemical Penetration Enhancers for Transdermal Drug Delivery Using Electrical Resistance of Skin","volume":"25","author":"Rachakonda","year":"2008","journal-title":"Pharm. Res."},{"key":"ref_14","unstructured":"Valeriya, N., Pereverzyev, S.V., and Sampath, S. (2011., January 12\u201315). Reading blood glucose from subcutaneous electric current by means of a regularization in variable Reproducing Kernel Hilbert Spaces. Orlando, FL, USA."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1002\/1520-6017(200105)90:5<545::AID-JPS1012>3.0.CO;2-H","article-title":"Theoretical description of transdermal transport of hydrophilic permeants: Application to Low-Frequency Sonophoresis","volume":"90","author":"Tang","year":"2001","journal-title":"J. Pharm. Sci."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Yu, H., Liu, J., Shi, T., Li, D., Du, Z., and Xu, K. (2008, January 19). Using skin impedance to improve prediction accuracy of continuous glucose monitoring system. San Jose, CA, USA.","DOI":"10.1117\/12.762154"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1007\/BF02523842","article-title":"Factors affecting electrode-gel-skin interface impedance in electrical impedance tomography","volume":"34","author":"McAdams","year":"1996","journal-title":"Med. Biol. Eng. Comput."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/4\/7084\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:10:33Z","timestamp":1760217033000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/4\/7084"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,4,22]]},"references-count":17,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2014,4]]}},"alternative-id":["s140407084"],"URL":"https:\/\/doi.org\/10.3390\/s140407084","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2014,4,22]]}}}