{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T13:32:51Z","timestamp":1773235971026,"version":"3.50.1"},"reference-count":20,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2014,6,10]],"date-time":"2014-06-10T00:00:00Z","timestamp":1402358400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Biosignals will play an important role in building communication between machines and humans. One of the types of biosignals that is widely used in neuroscience are electrooculography (EOG) signals. An EOG has a linear relationship with eye movement displacement. Experiments were performed to construct a gaze motion tracking method indicated by robot manipulator movements. Three operators looked at 24 target points displayed on a monitor that was 40 cm in front of them. Two channels (Ch1 and Ch2) produced EOG signals for every single eye movement. These signals were converted to pixel units by using the linear relationship between EOG signals and gaze motion distances. The conversion outcomes were actual pixel locations. An affine transform method is proposed to determine the shift of actual pixels to target pixels. This method consisted of sequences of five geometry processes, which are translation-1, rotation, translation-2, shear and dilatation. The accuracy was approximately 0.86\u00b0 \u00b1 0.67\u00b0 in the horizontal direction and 0.54\u00b0 \u00b1 0.34\u00b0 in the vertical. This system successfully tracked the gaze motions not only in direction, but also in distance. Using this system, three operators could operate a robot manipulator to point at some targets. This result shows that the method is reliable in building communication between humans and machines using EOGs.<\/jats:p>","DOI":"10.3390\/s140610107","type":"journal-article","created":{"date-parts":[[2014,6,10]],"date-time":"2014-06-10T11:50:51Z","timestamp":1402401051000},"page":"10107-10123","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Affine Transform to Reform Pixel Coordinates of EOG Signals for Controlling Robot Manipulators Using Gaze Motions"],"prefix":"10.3390","volume":"14","author":[{"given":"Muhammad","family":"Rusydi","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Gifu University, 1-1 Yanagido, Gifu City, 501-1193, Japan"},{"name":"Department of Electrical Engineering, Andalas University, Limau Manis, Padang City, 25163, Indonesia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Minoru","family":"Sasaki","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Gifu University, 1-1 Yanagido, Gifu City, 501-1193, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoshi","family":"Ito","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Gifu University, 1-1 Yanagido, Gifu City, 501-1193, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2014,6,10]]},"reference":[{"key":"ref_1","unstructured":"Malmivuo, J., and Plonsey, R. (1995). Bioelectromagnetism, Oxford Unversity Press."},{"key":"ref_2","unstructured":"Aminoff, M., and Daroff, R. (2003). Encyclopedia of the Neurological Sciences, Academic Press. [1st ed.]."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"2640","DOI":"10.1016\/j.eswa.2012.11.012","article-title":"Internet Browsing Application Based on Electrooculography for Disabled People","volume":"7","author":"Lledo","year":"2013","journal-title":"Expert Syst. Appl."},{"key":"ref_4","unstructured":"Kumar, D., and Poole, E. (2002, January 23\u201326). Classification of EOG for Human Computer Interface. Houston, TX, USA."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.1016\/j.patrec.2009.12.017","article-title":"A Novel Eye Movement Detection Algorithm for EOG Driven Human Computer Interface","volume":"31","author":"Lv","year":"2010","journal-title":"Pattern Recognit. Lett."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2677","DOI":"10.1016\/j.eswa.2011.08.123","article-title":"EOG-Based Eye Movements Codification for Human Computer Interaction","volume":"39","author":"Barea","year":"2012","journal-title":"Expert Syst. Appl."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.eswa.2005.09.017","article-title":"Classification of Electro-Oculogram Signals Using Artificial Neural Network","volume":"21","author":"Guven","year":"2006","journal-title":"Expert Syst. Appl."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.protcy.2013.12.338","article-title":"Classifying Electrooculogram to Detect Directional Eye Movements","volume":"10","author":"Banerjee","year":"2013","journal-title":"Proceedia Technol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"10857","DOI":"10.1016\/j.eswa.2012.03.007","article-title":"EOG-Based Visual Navigation Interface Development","volume":"39","author":"Postelnicu","year":"2012","journal-title":"Expert Syst. Appl."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1765","DOI":"10.1016\/j.compbiomed.2007.05.003","article-title":"A Low-Cost Interface for Control of Computer Functions by Means of Eye Movements","volume":"37","author":"Borghetti","year":"2007","journal-title":"Comput. Biol. Med."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/j.bspc.2009.12.002","article-title":"A New Method for Calculating Eye Movement Displacement from AC Coupled Electro-Oculographic Signals in Head Mounted Eye-Gaze Input Interface","volume":"5","author":"Itakura","year":"2010","journal-title":"Biomed. Signal Process. Control"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Pinheiro, C.G., Naves, E.L.M., Pino, P., Losson, E., Andrade, A.O., and Bourhis, G. (2011). Alternative Communication Systems for People with Severe Motor Disabilities: A Survey. Biomed. Eng. Online, 10.","DOI":"10.1186\/1475-925X-10-31"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"3337","DOI":"10.1016\/j.eswa.2009.10.017","article-title":"EOG-Based Human-Computer Interface System Development","volume":"37","author":"Deng","year":"2010","journal-title":"Expert Syst. Appl."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1007\/BF00156005","article-title":"Studies on the Stability of the Clinical Electro-Oculogram","volume":"81","author":"Timmins","year":"1992","journal-title":"Doc. Ophtalmol."},{"key":"ref_15","unstructured":"Rusydi, M.I., Okamoto, T., Sasaki, M., and Ito, S. (2012, January 2\u20133). Line of Sight Estimation from EOG Signal with Variation of Electrode Position for Human Machine Interface. Jeonju, Korea."},{"key":"ref_16","unstructured":"Rusydi, M.I., Okamoto, T., Sasaki, M., and Ito, S. (2013, January 4\u20135). Using EOG Signal to Operate Robot Manipulator System for Tracking Objects in 2D Space. Nyeri, Kenya."},{"key":"ref_17","unstructured":"Technical Foundations of Digital Productions II. Available online: http:\/\/people.cs.clemson.edu\/\u223cdhouse\/courses\/401\/notes\/affines-matrices.pdf."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1016\/0013-4694(93)90111-8","article-title":"The Effect of Small Differences in Electrode Position on EOG Signals: Application to Vigilance Studies","volume":"86","author":"Hakkinen","year":"1993","journal-title":"Electroencephalogr. Clin. Neurophysiol."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Nojd, N., and Hyttinen, J. (2008, January 13\u201315). Modeling of EOG Electrode Position Optimization for Human-Computer Interface. Brussels, Belgium.","DOI":"10.4108\/ICST.BODYNETS2008.2924"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/j.cmpb.2004.06.001","article-title":"Automated Eye Tracking System Calibration using Artificial Neural Networks","volume":"76","author":"Coughlin","year":"2004","journal-title":"Comput. Methods Programs Biomed."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/6\/10107\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:12:16Z","timestamp":1760217136000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/6\/10107"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,6,10]]},"references-count":20,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2014,6]]}},"alternative-id":["s140610107"],"URL":"https:\/\/doi.org\/10.3390\/s140610107","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,6,10]]}}}