{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,5]],"date-time":"2026-04-05T16:27:31Z","timestamp":1775406451859,"version":"3.50.1"},"reference-count":34,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2014,6,27]],"date-time":"2014-06-27T00:00:00Z","timestamp":1403827200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The article offers a comparison of the sensitivities for vapour trace detection of Trinitrotoluene (TNT) explosives of two different sensor systems: a chemo-mechanical sensor based on chemically modified Atomic Force Microscope (AFM) cantilevers based on Micro Electro Mechanical System (MEMS) technology with optical detection (CMO), and a miniature system based on capacitive detection of chemically functionalized planar capacitors with interdigitated electrodes with a comb-like structure with electronic detection (CE). In both cases (either CMO or CE), the sensor surfaces are chemically functionalized with a layer of APhS (trimethoxyphenylsilane) molecules, which give the strongest sensor response for TNT. The construction and calibration of a vapour generator is also presented. The measurements of the sensor response to TNT are performed under equal conditions for both systems, and the results show that CE system with ultrasensitive electronics is far superior to optical detection using MEMS. Using CMO system, we can detect 300 molecules of TNT in 10+12 molecules of N2 carrier gas, whereas the CE system can detect three molecules of TNT in 10+12 molecules of carrier N2.<\/jats:p>","DOI":"10.3390\/s140711467","type":"journal-article","created":{"date-parts":[[2014,6,27]],"date-time":"2014-06-27T11:23:16Z","timestamp":1403868196000},"page":"11467-11491","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["Sensitivity Comparison of Vapor Trace Detection of Explosives Based on Chemo-Mechanical Sensing with Optical Detection and Capacitive Sensing with Electronic Detection"],"prefix":"10.3390","volume":"14","author":[{"given":"Drago","family":"Strle","sequence":"first","affiliation":[{"name":"Faculty for Electrical Engineering, University of Ljubljana, Tr\u017ea\u0161ka 25, Ljubljana 1000, Slovenia"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8709-9853","authenticated-orcid":false,"given":"Bogdan","family":"\u0160tefane","sequence":"additional","affiliation":[{"name":"Faculty for Chemistry and Chemical Technology, University of Ljubljana, A\u0161ker\u010deva 5,  Ljubljana 1000, Slovenia"}]},{"given":"Erik","family":"Zupani\u010d","sequence":"additional","affiliation":[{"name":"Institute Jozef Stefan, Jamova 39, Ljubljana 1000, Slovenia"}]},{"given":"Mario","family":"Trifkovi\u010d","sequence":"additional","affiliation":[{"name":"Faculty for Electrical Engineering, University of Ljubljana, Tr\u017ea\u0161ka 25, Ljubljana 1000, Slovenia"}]},{"given":"Marijan","family":"Ma\u010dek","sequence":"additional","affiliation":[{"name":"Faculty for Electrical Engineering, University of Ljubljana, Tr\u017ea\u0161ka 25, Ljubljana 1000, Slovenia"}]},{"given":"Gregor","family":"Jak\u0161a","sequence":"additional","affiliation":[{"name":"Faculty for Chemistry and Chemical Technology, University of Ljubljana, A\u0161ker\u010deva 5,  Ljubljana 1000, Slovenia"}]},{"given":"Ivan","family":"Kvasi\u010d","sequence":"additional","affiliation":[{"name":"Institute Jozef Stefan, Jamova 39, Ljubljana 1000, Slovenia"}]},{"given":"Igor","family":"Mu\u0161evi\u010d","sequence":"additional","affiliation":[{"name":"Institute Jozef Stefan, Jamova 39, Ljubljana 1000, Slovenia"}]}],"member":"1968","published-online":{"date-parts":[[2014,6,27]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1007\/s11220-007-0029-8","article-title":"Recent advances in trace explosives detection instrumentation","volume":"8","author":"Moore","year":"2007","journal-title":"Sens. Imaging Int. J."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1471","DOI":"10.1063\/1.1602156","article-title":"Sensitive detection of plastic explosives with self-assembled monolayer-coated microcantilevers","volume":"83","author":"Pinnaduwage","year":"2003","journal-title":"Appl. Phys. Lett."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/j.snb.2003.11.011","article-title":"Detection of 2,4-dinitrotoluene using microcantilever sensors","volume":"99","author":"Pinnaduwage","year":"2004","journal-title":"Sens. Actuators B Chem."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2690","DOI":"10.1021\/la035658f","article-title":"Adsorption of trinitrotoluene on uncoated silicon microcantilever surfaces","volume":"20","author":"Pinnaduwage","year":"2004","journal-title":"Langmuir"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1021\/cr0681041","article-title":"Microcantilevers: Sensing chemical interactions via mechanical motion","volume":"108","author":"Goeders","year":"2008","journal-title":"Chem. Rev."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2229","DOI":"10.1063\/1.1763252","article-title":"Cantilever transducers as a platform for chemical and biological sensors","volume":"75","author":"Lavrik","year":"2004","journal-title":"Rev. Sci. Instrum."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"4554","DOI":"10.1063\/1.1804998","article-title":"A sensitive, handheld vapor sensor based on microcantilevers","volume":"75","author":"Pinnaduwage","year":"2004","journal-title":"Rev. Sci. Instrum."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Zuo, G.M., Li, X., Zhang, Z., Yang, T., Wang, Y., Cheng, Z., and Feng, S. (2007). Dual-SAM functionalization on integrated cantilevers for specific trace-explosive sensing and non-specific adsorption suppression. Nanotechnology, 18.","DOI":"10.1088\/0957-4484\/18\/25\/255501"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1109\/JSEN.2008.917485","article-title":"Charge-based capacitive sensor array for CMOS-based laboratory-on-chip applications","volume":"8","author":"Sawan","year":"2008","journal-title":"IEEE Sens. J."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1109\/JSEN.2010.2041447","article-title":"CMOS capacitive sensors with sub-\u03bcM microelectrodes for bio sensing applications","volume":"10","author":"Wang","year":"2010","journal-title":"IEEE Sens. J."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1103\/PhysRevLett.56.930","article-title":"Atomic force microscope","volume":"56","author":"Binnig","year":"1986","journal-title":"Phys. Rev. Lett."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1126\/science.8153628","article-title":"Adhesion forces between individual ligand-receptor pairs","volume":"264","author":"Florin","year":"1994","journal-title":"Science"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1021\/ac00099a006","article-title":"Vapour detection using resonating cantilevers","volume":"67","author":"Thundat","year":"1995","journal-title":"Anal. Chem."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1002\/anie.200702894","article-title":"Making ultrasensitive weighing biocompatible by placing the sample within a resonant cantilever","volume":"46","author":"Tinnefeld","year":"2007","journal-title":"Angew. Chem. Int. Ed."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1103","DOI":"10.1021\/cr0300789","article-title":"Whitesides self-assembled monolayers of thiolates on metals as a form of nanotechnology","volume":"105","author":"Love","year":"2005","journal-title":"Chem. Rev."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1103\/RevModPhys.75.949","article-title":"Advances in atomic force microscopy","volume":"75","author":"Giessibl","year":"2003","journal-title":"Rev. Mod. Phys."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Sarid, D. (1994). Scanning Force Microscopy, Oxford University Press. [2nd ed.].","DOI":"10.1093\/oso\/9780195092042.001.0001"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1063\/1.108593","article-title":"Atomic resolution with an atomic force microscope using piezoresistive detection","volume":"62","author":"Tortonese","year":"1993","journal-title":"Appl. Phys. Lett."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"2554","DOI":"10.1063\/1.1147212","article-title":"Temperature controlled microstage for an atomic force microscope","volume":"67","author":"Slak","year":"1996","journal-title":"Rev. Sci. Instrum."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Carbone, G., Barberi, R., Mu\u0161evi\u010d, I., and Kr\u017ei\u010d, U. (2005). Atomic Force Microscope Study of Presmectic Modulation in the Nematic and Isotropic Phases of the Liquid Crystal Octylcyanobiphenyl Using Piezoresistive Force Spectroscopy. Phys. Rev. E., 71.","DOI":"10.1103\/PhysRevE.71.051704"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Mu\u0161evi\u010d, I., Ko\u010devar, K., Kr\u017ei\u010d, U., and Carbone, G. (2005). Force spectroscopy based on temperature controlled atomic force microscope head using piezoresistive cantilevers. Rev. Sci. Instrum., 76.","DOI":"10.1063\/1.1884191"},{"key":"ref_22","unstructured":"Zuo, G., Li, X., Li, P., Wang, Y., Zhenxing, C., and Feng, S. (2006, January 22\u201325). Trace TNT vapour detection with an SAM-functionalized piezoresistive SiO2 microcantilever. Daegu, Korea."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"6830","DOI":"10.1002\/anie.201000847","article-title":"Supersensitive detection of explosives by silicon nanowire arrays","volume":"49","author":"Engel","year":"2010","journal-title":"Angew. Chem. Int. Ed."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1959","DOI":"10.1109\/JSSC.2009.2020246","article-title":"Noise reduction in CMOS circuits through switched gate and forward substrate bias","volume":"44","author":"Siprak","year":"2009","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1909","DOI":"10.1163\/156939309789932458","article-title":"A noise optimized passive mixer for charge-domain sampling applications","volume":"23","author":"Park","year":"2009","journal-title":"J. Electromagn. Waves Appl."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1109\/JSSC.2002.807173","article-title":"An offset-canceling low-noise lock-in architecture for capacitive sensing","volume":"38","author":"Tavakoli","year":"2003","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1109\/TIM.2007.911584","article-title":"High-frequency digital lock-in amplifier using random sampling","volume":"57","author":"Sormaillon","year":"2008","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_28","unstructured":"Burns, M., and Roberts, G.W. (2001). An Introduction to Mixed-Signal IC Test and Measurement, Oxford University Press."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"2573","DOI":"10.1109\/TCSI.2008.920063","article-title":"An electronically tuneable linear or nonlinear MOS resistor","volume":"55","author":"Wee","year":"2008","journal-title":"IEEE Trans. Circuits Syst. I"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1109\/TCSI.2009.2023762","article-title":"Noise in current-commutating passive FET mixers","volume":"57","author":"Chehrazi","year":"2010","journal-title":"IEEE Trans. Circuits Syst. I"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1109\/JSSC.2006.891714","article-title":"Low-frequency noise phenomena in switched MOSFETs","volume":"42","author":"Klumperink","year":"2007","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1088\/0957-4484\/21\/26\/265501","article-title":"Self-assembling siloxane bilayer directly on SiO2 surface of micro-cantilevers for long-term, highly repeatable sensing of trace explosives","volume":"21","author":"Chen","year":"2010","journal-title":"Nanotechnology"},{"key":"ref_33","unstructured":"Bennett, K. (2014). MATLAB, InTeh."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Assisi, A. (2011). Engineering Education and Research Using MATLAB, InTeh.","DOI":"10.5772\/1532"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/7\/11467\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:13:02Z","timestamp":1760217182000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/7\/11467"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,6,27]]},"references-count":34,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2014,7]]}},"alternative-id":["s140711467"],"URL":"https:\/\/doi.org\/10.3390\/s140711467","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,6,27]]}}}