{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,26]],"date-time":"2026-03-26T20:26:57Z","timestamp":1774556817897,"version":"3.50.1"},"reference-count":18,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2014,7,11]],"date-time":"2014-07-11T00:00:00Z","timestamp":1405036800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A new Mg2+-selective fluorescent probe P was synthesized and characterized. With optimal conditions, the proposed probe P showed good selectivity to Mg2+ compared to other common metal ions, and worked in a wide linear range of 5.0 \u00d7 10\u22127\u20136.0 \u00d7 10\u22126 M with a detection limit of 1.7 \u00d7 10\u22127 M Mg2+ in ethanol-water solution (9:1, v\/v, 20 mM HEPES, pH = 10.0).<\/jats:p>","DOI":"10.3390\/s140712560","type":"journal-article","created":{"date-parts":[[2014,7,11]],"date-time":"2014-07-11T10:48:29Z","timestamp":1405075709000},"page":"12560-12567","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Synthesis and Characterization of a Mg2+-Selective  Fluorescent Probe"],"prefix":"10.3390","volume":"14","author":[{"given":"Chunwei","family":"Yu","sequence":"first","affiliation":[{"name":"Laboratory of Environmental Monitoring, School of Tropical and Laboratory Medicine, Hainan Medical University, Haikou 571101, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qiongyao","family":"Fu","sequence":"additional","affiliation":[{"name":"Faculty of Laboratory Medicine, School of Tropical and Laboratory Medicine,  Hainan Medical University, Haikou 571199, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jun","family":"Zhang","sequence":"additional","affiliation":[{"name":"Laboratory of Environmental Monitoring, School of Tropical and Laboratory Medicine, Hainan Medical University, Haikou 571101, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2014,7,11]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1039\/C3DT51900G","article-title":"Coordination-driven nanosized lanthanide \u2018Molecular Lanterns\u2019 as luminescent chemosensors for the selective sensing of magnesium ions","volume":"43","author":"Zhao","year":"2014","journal-title":"Dalton Trans."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1039\/C3AN01737K","article-title":"A novel fluorescent chemosensor allows the assessment of intracellular total magnesium in small samples","volume":"139","author":"Sargenti","year":"2014","journal-title":"Analyst"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1023\/A:1016058229972","article-title":"Magnesium chemistry and biochemistry","volume":"15","author":"Maguire","year":"2002","journal-title":"BioMetals"},{"key":"ref_4","first-page":"715","article-title":"Fluorescent probes for sensing magnesium ions","volume":"21","author":"Zhang","year":"2009","journal-title":"Prog. Chem."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1021\/ja056523u","article-title":"8-hydroxyquinoline derivatives as fluorescent sensors for magnesium in living cells","volume":"128","author":"Farruggia","year":"2006","journal-title":"J. Am. Chem. Soc."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"5397","DOI":"10.1016\/j.tetlet.2007.06.010","article-title":"Ratiometric chemosensing of Mg2+ ions by a calix[4]arene diamide derivative","volume":"48","author":"Song","year":"2007","journal-title":"Tetrahedron Lett."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1663","DOI":"10.1016\/j.talanta.2005.08.030","article-title":"Magnesium optical one-shot sensor based on a coumarin chromoionophore","volume":"68","author":"Brunet","year":"2006","journal-title":"Talanta"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.jphotochem.2010.07.017","article-title":"Solvent effect on photophysical properties and Mg2+ binding of 1,3-diphenyl-propane-1,3-dione","volume":"215","author":"Chaudhuri","year":"2010","journal-title":"J. Photochem. Photobiol. A Chem."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1002\/ange.200904859","article-title":"A Porphyrin-Related Macrocycle with an Embedded 1,10-Phenanthroline Moiety: Fluorescent Magnesium(II) Ion Sensor","volume":"122","author":"Ishida","year":"2010","journal-title":"Angew. Chem. Int. Ed."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"8110","DOI":"10.1021\/ac302210v","article-title":"Dual-Color Imaging of Magnesium\/Calcium Ion Activities with Two-Photon Fluorescent Probes","volume":"84","author":"Dong","year":"2012","journal-title":"Anal. Chem."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"594","DOI":"10.1016\/j.saa.2012.07.032","article-title":"A new dual functional sensor: Highly selective colorimetric chemosensor for Fe3+ and fluorescent sensor for Mg2+","volume":"96","author":"Devaraj","year":"2012","journal-title":"Spectrochim. Acta Part A"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"9450","DOI":"10.1039\/c1cc12957k","article-title":"L-Proline promoted fluorescent sensor for Mg2+ detection in a multicomponent sensory system","volume":"47","author":"Dong","year":"2011","journal-title":"Chem. Commun."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2252","DOI":"10.1021\/ic702388z","article-title":"A Coumarin-Derived Fluorescence Probe Selective for Magnesium","volume":"47","author":"Ray","year":"2008","journal-title":"Inorg. Chem."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"6690","DOI":"10.1016\/j.tetlet.2008.09.052","article-title":"A ratiometric fluorescent probe for magnesium employing excited state intramolecular proton transfer","volume":"49","author":"Singh","year":"2008","journal-title":"Tetrahedron Lett."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"3460","DOI":"10.1002\/anie.200700169","article-title":"Environment-Sensitive Two-Photon Probe for Intracellular Free Magnesium Ions in Live Tissue","volume":"46","author":"Kim","year":"2007","journal-title":"Angew. Chem. Int. Ed."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1039\/b212835g","article-title":"Development of selective, visible light-excitable, fluorescent magnesium probes with a novel fluorescence switching mechanism","volume":"128","author":"Shoda","year":"2003","journal-title":"Analyst"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2088","DOI":"10.1021\/jo062341m","article-title":"Magnesium Ion Selective Two-Photon Fluorescent Probe Based on a Benzo[h]chromene Derivative for in Vivo Imaging","volume":"72","author":"Kim","year":"2007","journal-title":"J. Org. Chem."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"18011","DOI":"10.1002\/chem.201300169","article-title":"New calcium-selective smart contrast agents for magnetic resonance imaging","volume":"19","author":"Verma","year":"2013","journal-title":"Chemistry"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/7\/12560\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:13:33Z","timestamp":1760217213000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/7\/12560"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,7,11]]},"references-count":18,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2014,7]]}},"alternative-id":["s140712560"],"URL":"https:\/\/doi.org\/10.3390\/s140712560","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,7,11]]}}}