{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T23:11:49Z","timestamp":1782947509533,"version":"3.54.5"},"reference-count":32,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2014,8,4]],"date-time":"2014-08-04T00:00:00Z","timestamp":1407110400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"funder":[{"DOI":"10.13039\/501100000780","name":"European Commission","doi-asserted-by":"publisher","award":["257372"],"award-info":[{"award-number":["257372"]}],"id":[{"id":"10.13039\/501100000780","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A sensor for the simple and sensitive measurement of hydrogen peroxide has been developed which is based on screen printed electrodes (SPEs) modified with Prussian blue nanoparticles (PBNPs) deposited using piezoelectric inkjet printing. PBNP-modified SPEs were characterized using physical and electrochemical techniques to optimize the PBNP layer thickness and electroanalytical conditions for optimum measurement of hydrogen peroxide. Sensor optimization resulted in a limit of detection of 2 \u00d7 10\u22127 M, a linear range from 0 to 4.5 mM and a sensitivity of 762 \u03bcA\u2219mM\u20131\u2219cm\u20132 which was achieved using 20 layers of printed PBNPs. Sensors also demonstrated excellent reproducibility (&lt;5% rsd).<\/jats:p>","DOI":"10.3390\/s140814222","type":"journal-article","created":{"date-parts":[[2014,8,5]],"date-time":"2014-08-05T10:59:37Z","timestamp":1407236377000},"page":"14222-14234","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":94,"title":["Development of a Hydrogen Peroxide Sensor Based on  Screen-Printed Electrodes Modified with Inkjet-Printed Prussian Blue Nanoparticles"],"prefix":"10.3390","volume":"14","author":[{"given":"Stefano","family":"Cinti","sequence":"first","affiliation":[{"name":"Dipartimento di Scienze e Tecnologie Chimiche, Universit\u00e0 di Roma Tor Vergata, Via della Ricerca Scientifica 1, Rome 00133, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabiana","family":"Arduini","sequence":"additional","affiliation":[{"name":"Dipartimento di Scienze e Tecnologie Chimiche, Universit\u00e0 di Roma Tor Vergata, Via della Ricerca Scientifica 1, Rome 00133, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Danila","family":"Moscone","sequence":"additional","affiliation":[{"name":"Dipartimento di Scienze e Tecnologie Chimiche, Universit\u00e0 di Roma Tor Vergata, Via della Ricerca Scientifica 1, Rome 00133, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppe","family":"Palleschi","sequence":"additional","affiliation":[{"name":"Dipartimento di Scienze e Tecnologie Chimiche, Universit\u00e0 di Roma Tor Vergata, Via della Ricerca Scientifica 1, Rome 00133, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony","family":"Killard","sequence":"additional","affiliation":[{"name":"Department of Biological, Biomedical and Analytical Sciences, Faculty of Health and Applied Sciences, University of the West of England, Coldharbour Lane, Bristol   BS16 1QY, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2014,8,4]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1039\/C1AN15738H","article-title":"Recent advances in electrochemical sensing for hydrogen peroxide: A review","volume":"137","author":"Chen","year":"2012","journal-title":"Analyst"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1002\/jps.22812","article-title":"Forced Degradation of Therapeutic Proteins","volume":"101","author":"Hawe","year":"2012","journal-title":"J. Pharm. Sci."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"996","DOI":"10.1038\/nature08119","article-title":"A tissue-scale gradient of hydrogen peroxide mediates rapid wound detection in zebrafish","volume":"459","author":"Niethammer","year":"2009","journal-title":"Nature"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1016\/j.bios.2008.06.053","article-title":"A novel hydrogen peroxide sensor based on the direct electron transfer of horseradish peroxidase immobilized on silica\u2013hydroxyapatite hybrid film","volume":"24","author":"Wang","year":"2009","journal-title":"Biosens. Bioelectron."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/j.talanta.2004.10.001","article-title":"Simple and fast spectrophotometric determination of H2O2 in photo-Fenton reactions using metavanadate","volume":"66","author":"Oliveira","year":"2005","journal-title":"Talanta"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/S0003-2670(00)01181-8","article-title":"Chemiluminescent flow sensor for H2O2 based on the decomposition of H2O2 catalyzed by cobalt(II)-ethanolamine complex immobilized on resin","volume":"426","author":"Hanaoka","year":"2001","journal-title":"Anal. Chim. Acta"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.jbbm.2005.10.003","article-title":"Fluorescence probes used for detection of reactive oxygen species","volume":"65","author":"Gomes","year":"2005","journal-title":"J. Biochem. Biophys. Methods"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1007\/s00604-011-0736-7","article-title":"Sensor for hydrogen peroxide using a hemoglobin-modified glassy carbon electrode prepared by enhanced loading of silver nanoparticle onto carbon nanospheres via spontaneous polymerization of dopamine","volume":"176","author":"Wang","year":"2012","journal-title":"Microchim. Acta"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1016\/j.snb.2013.03.006","article-title":"Non enzymatic hydrogen peroxide detection at ruthenium oxide\u2013gold nano particle\u2013Nafion modified electrode","volume":"182","author":"Anjalidevi","year":"2013","journal-title":"Sens. Actuators B Chem."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1007\/s00604-013-1012-9","article-title":"Determination of hydrogen peroxide and glucose using a novel sensor platform based on Co0.4Fe0.6LaO3 nanoparticles","volume":"180","author":"Zhang","year":"2013","journal-title":"Microchim. Acta"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.colsurfb.2011.09.002","article-title":"Synthesis of mesostructured polyaniline using mixed surfactants, anionic sodium dodecylsulfate and non-ionic polymers and their applications in H2O2 and glucose sensing","volume":"89","author":"Thakur","year":"2012","journal-title":"Colloids Surf. B"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/j.bios.2004.12.001","article-title":"Sensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes","volume":"21","author":"Ricci","year":"2005","journal-title":"Biosens. Bioelectron"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"5048","DOI":"10.1016\/j.electacta.2008.11.049","article-title":"Diffusion controlled analytical performances of hydrogen peroxide sensors: Towards the sensor with the largest dynamic range","volume":"54","author":"Karyakin","year":"2009","journal-title":"Electrochim. Acta"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.aca.2006.07.052","article-title":"Detection of carbamic and organophosphorous pesticides in water samples using a cholinesterase biosensor based on Prussian Blue-modified screen-printed electrode","volume":"580","author":"Arduini","year":"2006","journal-title":"Anal. Chim. Acta"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1016\/j.snb.2010.03.020","article-title":"Electrochemical behavior and application of Prussian blue nanoparticle modified graphite electrode","volume":"147","author":"Haghighi","year":"2010","journal-title":"Sens. Actuators B Chem."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1016\/j.matchemphys.2012.01.074","article-title":"In site formation and growth of Prussian blue nanoparticles anchored to multiwalled carbon nanotubes with poly(4-vinylpyridine) linker by layer-by-layer assembly","volume":"133","author":"Li","year":"2012","journal-title":"Mater. Chem. Phys."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2339","DOI":"10.1021\/am100372m","article-title":"In situ controllable growth of Prussian Blue nanocubes on reduced graphene oxide: Facile synthesis and their application as enhanced nano electrocatalyst for H2O2 reduction","volume":"2","author":"Cao","year":"2010","journal-title":"Appl. Mater. Interfaces"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1038\/nature10313","article-title":"Inkjet printing of single-crystal films","volume":"475","author":"Minemawari","year":"2011","journal-title":"Nature"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1007\/s12274-011-0123-z","article-title":"Graphene-based conducting inks for direct inkjet printing of flexible conductive patterns and their applications in electric circuits and chemical sensors","volume":"4","author":"Huang","year":"2011","journal-title":"Nano Res."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.aca.2013.03.051","article-title":"Direct measurement of ammonia in simulated human breath using an inkjet-printed polyaniline nanoparticle sensor","volume":"779","author":"Hibbard","year":"2013","journal-title":"Anal. Chim. Acta"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1039\/b916888e","article-title":"Advanced printing and deposition methodologies for the fabrication of biosensors and biodevices","volume":"135","author":"Morrin","year":"2010","journal-title":"Analyst"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"135","DOI":"10.2116\/analsci.28.135","article-title":"Inkjet printed Prussian Blue films for hydrogen peroxide detection","volume":"28","author":"Hu","year":"2012","journal-title":"Anal. Sci."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1007\/s00216-007-1330-z","article-title":"Fast, sensitive and cost-effective detection of nerve agents in the gas phase using a portable instrument and an electrochemical biosensor","volume":"388","author":"Arduini","year":"2007","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"931","DOI":"10.1002\/elan.201400041","article-title":"Stripping analysis of As(III) by means of screen-printed electrodes modified with gold nanoparticles and carbon black nanocomposite","volume":"26","author":"Cinti","year":"2014","journal-title":"Electroanalysis"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1134\/S1061933X07050195","article-title":"Immobilization of Prussian Blue nanoparticles onto thiol SAM modified Au electrodes for analysis of DL-homocysteine","volume":"69","author":"Chen","year":"2007","journal-title":"Colloid J."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"7339","DOI":"10.1021\/ic0488435","article-title":"Size and surface effects of Prussian blue nanoparticles protected by organic polymers","volume":"43","author":"Uemura","year":"2004","journal-title":"Inorg. Chem."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/S0022-0728(79)80075-3","article-title":"General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems","volume":"101","author":"Laviron","year":"1979","journal-title":"J. Electroanal. Chem."},{"key":"ref_28","unstructured":"Bard, A.J., and Faulkner, L.R. (1980). Electrochemical Method Fundamentals and Applications, Wiley. Chapter 12."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1720","DOI":"10.1021\/ac990801o","article-title":"Amperometric Biosensor for Glutamate Using Prussian Blue-Based \u201cArtificial Peroxidase\u201d as a Transducer for Hydrogen Peroxide","volume":"72","author":"Karyakin","year":"2000","journal-title":"Anal. Chem."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"2529","DOI":"10.1021\/ac001245x","article-title":"Construction and Analytical Characterization of Prussian Blue-Based Carbon Paste Electrodes and Their Assembly as Oxidase Enzyme Sensors","volume":"73","author":"Moscone","year":"2001","journal-title":"Anal. Chem."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"2669","DOI":"10.1016\/j.bios.2006.10.035","article-title":"Biosensor based on polyaniline\u2013Prussian Blue\/multi-walled carbon nanotubes hybrid composites","volume":"22","author":"Zou","year":"2007","journal-title":"Biosens. Bioelectron."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.electacta.2012.07.038","article-title":"Facile and controllable synthesis of Prussian blue on chitosan-functionalized graphene nanosheets for the electrochemical detection of hydrogen peroxide","volume":"81","author":"Yang","year":"2012","journal-title":"Electrochim. Acta"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/8\/14222\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:14:22Z","timestamp":1760217262000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/8\/14222"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,8,4]]},"references-count":32,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2014,8]]}},"alternative-id":["s140814222"],"URL":"https:\/\/doi.org\/10.3390\/s140814222","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,8,4]]}}}