{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T17:40:10Z","timestamp":1792086010832,"version":"4.4.0"},"reference-count":33,"publisher":"MDPI AG","issue":"10","license":[{"start":{"date-parts":[[2014,10,1]],"date-time":"2014-10-01T00:00:00Z","timestamp":1412121600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Electroencephalogram (EEG) recordings are often contaminated with muscular artifacts that strongly obscure the EEG signals and complicates their analysis. For the conventional case, where the EEG recordings are obtained simultaneously over many EEG channels, there exists a considerable range of methods for removing muscular artifacts. In recent years, there has been an increasing trend to use EEG information in ambulatory healthcare and related physiological signal monitoring systems. For practical reasons, a single EEG channel system must be used in these situations. Unfortunately, there exist few studies for muscular artifact cancellation in single-channel EEG recordings. To address this issue, in this preliminary study, we propose a simple, yet effective, method to achieve the muscular artifact cancellation for the single-channel EEG case. This method is a combination of the ensemble empirical mode decomposition (EEMD) and the joint blind source separation (JBSS) techniques. We also conduct a study that compares and investigates all possible single-channel solutions and demonstrate the performance of these methods using numerical simulations and real-life applications. The proposed method is shown to significantly outperform all other methods. It can successfully remove muscular artifacts without altering the underlying EEG activity. It is thus a promising tool for use in ambulatory healthcare systems.<\/jats:p>","DOI":"10.3390\/s141018370","type":"journal-article","created":{"date-parts":[[2014,10,1]],"date-time":"2014-10-01T10:28:17Z","timestamp":1412159297000},"page":"18370-18389","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":68,"title":["A Preliminary Study of Muscular Artifact Cancellation in Single-Channel EEG"],"prefix":"10.3390","volume":"14","author":[{"given":"Xun","family":"Chen","sequence":"first","affiliation":[{"name":"Department of Biomedical Engineering, School of Medical Engineering, Hefei University of Technology, Hefei 230009, China"},{"name":"Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aiping","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hu","family":"Peng","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, School of Medical Engineering, Hefei University of Technology, Hefei 230009, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rabab","family":"Ward","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2014,10,1]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1109\/TBME.2008.2005969","article-title":"Automatic EEG Artifact Removal: A Weighted Support-Vector-Machine Approach With Error Correction","volume":"56","author":"Shao","year":"2009","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1016\/j.neuroimage.2010.07.057","article-title":"Electromyogenic artifacts and electroencephalographic inferences revisited","volume":"54","author":"McMenamin","year":"2011","journal-title":"NeuroImage"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1567","DOI":"10.1212\/WNL.35.11.1567","article-title":"Reliability and accuracy of localization by scalp ictal EEG","volume":"35","author":"Spencer","year":"1985","journal-title":"Neurology"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1580","DOI":"10.1016\/S1388-2457(03)00093-2","article-title":"EMG contamination of EEG: Spectral and topographical characteristics","volume":"114","author":"Goncharova","year":"2003","journal-title":"Clin. Neurophysiol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1109\/10.841330","article-title":"Independent component approach to the analysis of EEG and MEG recordings","volume":"47","author":"Vigario","year":"2000","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1016\/j.jneumeth.2006.05.033","article-title":"Recovering EEG brain signals: Artifact suppression with wavelet enhanced independent component analysis","volume":"158","author":"Castellanos","year":"2006","journal-title":"J. Neurosci. Methods"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1007\/s10439-008-9442-y","article-title":"Muscle artifact removal from human sleep EEG by using independent component analysis","volume":"36","author":"Atienza","year":"2008","journal-title":"Ann. Biomed. Eng."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1046\/j.1528-1157.2002.23501.x","article-title":"Independent component analysis of ictal EEG in medial temporal lobe epilepsy","volume":"43","author":"Nam","year":"2002","journal-title":"Epilepsia"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1071","DOI":"10.1111\/j.0013-9580.2004.12104.x","article-title":"Independent component analysis removing artifacts in ictal recordings","volume":"45","author":"Urrestarazu","year":"2004","journal-title":"Epilepsia"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1109\/78.554307","article-title":"A blind source separation technique using second-order statistics","volume":"45","author":"Belouchrani","year":"1997","journal-title":"IEEE Trans. Signal Process."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"2583","DOI":"10.1109\/TBME.2006.879459","article-title":"Canonical Correlation Analysis Applied to Remove muscle artifacts From the Electroencephalogram","volume":"53","author":"Clercq","year":"2006","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1177\/155005941004100111","article-title":"Online removal of muscle artifact from electroencephalogram signals based on canonical correlation analysis","volume":"41","author":"Gao","year":"2010","journal-title":"Clin. EEG Neurosci."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Chen, X., and Wang, Z.J. (2011, January 10\u201312). Design and implementation of a wearable, wireless EEG recording system. Wuhan, China.","DOI":"10.1109\/icbbe.2011.5781501"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Ridwan, S.D., Thompson, R., Jap, B.T., Lal, S., and Fischer, P. (2008, January 23\u201326). Single channel wireless EEG: Proposed application in train drivers. Gauteng, South Africa.","DOI":"10.1109\/BROADCOM.2008.69"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1016\/j.compbiomed.2012.09.012","article-title":"An ensemble system for automatic sleep stage classification using single channel EEG signal","volume":"42","author":"Koley","year":"2012","journal-title":"Comput. Biol. Med."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1098\/rspa.1998.0193","article-title":"The empirical mode decomposition and the Hilbert spectrum for nonlinear and nonstationary time series analysis","volume":"454","author":"Huang","year":"1998","journal-title":"Proc. R. Soc."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2441","DOI":"10.1109\/TBME.2011.2151861","article-title":"Combination of canonical correlation analysis and empirical mode decomposition applied to denoising the labor electrohysterogram","volume":"58","author":"Hassan","year":"2011","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"14839","DOI":"10.3390\/s131114839","article-title":"EOG Artifact Correction from EEG Recording Using Stationary Subspace Analysis and Empirical Mode Decomposition","volume":"13","author":"Zeng","year":"2013","journal-title":"Sensors"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1142\/S1793536909000047","article-title":"Ensemble empirical mode decomposition: A noise-assisted data analysis method","volume":"1","author":"Wu","year":"2009","journal-title":"Adv. Adapt. Data Anal."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1109\/TBME.2012.2225427","article-title":"The Use of Ensemble Empirical Mode Decomposition With Canonical Correlation Analysis as a Novel Artifact Removal Technique","volume":"60","author":"Sweeney","year":"2013","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1672","DOI":"10.1109\/TSP.2011.2181836","article-title":"Joint blind source separation with multivariate Gaussian model: Algorithms and performance analysis","volume":"60","author":"Anderson","year":"2012","journal-title":"IEEE Trans. Signal Process."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.1109\/TBME.2014.2319294","article-title":"An EEMD-IVA Framework for Concurrent Multidimensional EEG and Unidimensional Kinematic Data Analysis","volume":"61","author":"Chen","year":"2014","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1819","DOI":"10.1016\/j.sigpro.2007.01.011","article-title":"Source separation using single channel ICA","volume":"87","author":"Davies","year":"2007","journal-title":"Signal Process."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"2188","DOI":"10.1109\/TBME.2010.2051440","article-title":"Source separation from single-channel recordings by combining empirical-mode decomposition and independent component analysis","volume":"57","author":"Mijovic","year":"2010","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1483","DOI":"10.1162\/neco.1997.9.7.1483","article-title":"Fast fixed-point algorithm for independent component analysis","volume":"9","author":"Hyvarinen","year":"1997","journal-title":"Neural Comput."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1093\/biomet\/28.3-4.321","article-title":"Relations between two sets of variates","volume":"28","author":"Hotelling","year":"1936","journal-title":"Biometrika"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Chen, X., Liu, A., Wang, Z.J., and Peng, H. (2013). Corticomuscular Activity Modeling by Combining Partial Least Squares and Canonical Correlation Analysis. J. Appl. Math.","DOI":"10.1155\/2013\/401976"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1006\/nimg.2002.1067","article-title":"Exploratory fMRI analysis by autocorrelation maximization","volume":"16","author":"Friman","year":"2002","journal-title":"NeuroImage"},{"key":"ref_29","unstructured":"Borga, M., and Knutsson, H. (2001). A Canonical Correlation Approach to Blind Source Separation, Linkoping University. Technical Report LiU-IMT-EX-0062."},{"key":"ref_30","unstructured":"Kim, T., Eltoft, T., and Lee, T.W. (2006). Independent Component Analysis and Blind Signal Separation, Springer."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1016\/j.neuroimage.2004.10.020","article-title":"Auditory event-related responses are generated independently of ongoing brain activity","volume":"24","author":"Makinen","year":"2005","journal-title":"NeuroImage"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1111\/j.1469-8986.2006.00482.x","article-title":"Theta phase resetting and the error-related negativity","volume":"44","author":"Yeung","year":"2007","journal-title":"Psychophysiology"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1443","DOI":"10.1016\/j.neuroimage.2006.11.004","article-title":"Enhanced detection of artifacts in EEG data using higher-order statistics and independent component analysis","volume":"34","author":"Delorme","year":"2007","journal-title":"NeuroImage"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/10\/18370\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:16:36Z","timestamp":1760217396000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/10\/18370"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,10,1]]},"references-count":33,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2014,10]]}},"alternative-id":["s141018370"],"URL":"https:\/\/doi.org\/10.3390\/s141018370","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,10,1]]}}}