{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:29:36Z","timestamp":1760243376765,"version":"build-2065373602"},"reference-count":15,"publisher":"MDPI AG","issue":"10","license":[{"start":{"date-parts":[[2014,10,17]],"date-time":"2014-10-17T00:00:00Z","timestamp":1413504000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A novel multifrequency excitation (MFE) method is proposed to realize rapid and accurate dynamic testing of micromachined gyroscope chips. Compared with the traditional sweep-frequency excitation (SFE) method, the computational time for testing one chip under four modes at a 1-Hz frequency resolution and 600-Hz bandwidth was dramatically reduced from 10 min to 6 s. A multifrequency signal with an equal amplitude and initial linear-phase-difference distribution was generated to ensure test repeatability and accuracy. The current test system based on LabVIEW using the SFE method was modified to use the MFE method without any hardware changes. The experimental results verified that the MFE method can be an ideal solution for large-scale dynamic testing of gyroscope chips and gyroscopes.<\/jats:p>","DOI":"10.3390\/s141019507","type":"journal-article","created":{"date-parts":[[2014,10,17]],"date-time":"2014-10-17T10:27:19Z","timestamp":1413541639000},"page":"19507-19516","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Multifrequency Excitation Method for Rapid and Accurate Dynamic Test of Micromachined Gyroscope Chips"],"prefix":"10.3390","volume":"14","author":[{"given":"Yan","family":"Deng","sequence":"first","affiliation":[{"name":"State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Beijing 100084, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bin","family":"Zhou","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Beijing 100084, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chao","family":"Xing","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Beijing 100084, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rong","family":"Zhang","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Beijing 100084, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2014,10,17]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1394","DOI":"10.3390\/s140101394","article-title":"The development of micromachined gyroscope structure and circuitry technology","volume":"14","author":"Xia","year":"2014","journal-title":"Sensors"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2396","DOI":"10.4028\/www.scientific.net\/AMM.333-335.2396","article-title":"Automated calibration system for IMU based on database and LabVIEW","volume":"333\u2013335","author":"Deng","year":"2013","journal-title":"Appl. Mech. Mater."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.sna.2013.01.023","article-title":"Constant-Frequency oscillation control for vibratory micro-machined gyroscopes","volume":"193","author":"Zhu","year":"2013","journal-title":"Sensors Actuators A Phys"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1088\/0957-0233\/23\/8\/085107","article-title":"Methods for the robust measurement of the resonant frequency and quality factor of significantly damped resonating devices","volume":"23","author":"Niedermayer","year":"2012","journal-title":"Meas. Sci. Technol."},{"key":"ref_5","first-page":"170","article-title":"Development of automatic test system for micromachined gyroscope based on LabVIEW","volume":"24","author":"He","year":"2011","journal-title":"Chin. J. Sens. Actuators"},{"key":"ref_6","unstructured":"Skvortzov, V., Cho, Y.C., Lee, B., and Song, C. (2004, January 26\u201329). Development of a gyro test system at Samsung Advanced Institute of Technology. Monterey, CA, USA."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"15770","DOI":"10.3390\/s131115770","article-title":"Two novel measurements for the drive-mode resonant frequency of a micromachined vibratory gyroscope","volume":"13","author":"Wang","year":"2013","journal-title":"Sensors"},{"key":"ref_8","first-page":"580","article-title":"Dynamic parameters test of micro-machined gyroscope based on LabVIEW","volume":"21","author":"Zhao","year":"2013","journal-title":"Comput. Meas. Control."},{"key":"ref_9","first-page":"391","article-title":"A new test method for the quality factor of MEMS gyroscopes","volume":"48","author":"Xu","year":"2011","journal-title":"Micronanoelectronic. Technol."},{"key":"ref_10","first-page":"637","article-title":"Digital readout system for a micro-machined gyroscope and its demodulation algorithm","volume":"44","author":"Zhou","year":"2004","journal-title":"J. Tsinghua Univ. (Sci. Technol.)"},{"key":"ref_11","first-page":"98","article-title":"On-Line self-testing for micro-machined gyroscopes","volume":"22","author":"Gaisser","year":"2005","journal-title":"Trans. Nanjing Univ. Aeronaut. Astronaut."},{"key":"ref_12","first-page":"111","article-title":"Test method of micromachined gyroscope chip","volume":"27","author":"Liu","year":"2008","journal-title":"Transducer Microsyst. Technol."},{"key":"ref_13","unstructured":"Oppenheim, A.V., Willsky, A.S., and Hamid, S. (1996). Signals and Systems, Prentice Hall. [2nd ed.]."},{"key":"ref_14","unstructured":"Wang, X., and Wang, H. (2005, January 17\u201319). Design and implementation of virtual sweep generator based on multi-frequency acoustic signal. Xi'an, China."},{"key":"ref_15","unstructured":"Piersol, A.G., and Paez, T.L. (2009). Harris' Shock and Vibration Handbook, McGraw-Hill. [6th ed.]."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/10\/19507\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:17:06Z","timestamp":1760217426000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/10\/19507"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,10,17]]},"references-count":15,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2014,10]]}},"alternative-id":["s141019507"],"URL":"https:\/\/doi.org\/10.3390\/s141019507","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2014,10,17]]}}}