{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T00:56:45Z","timestamp":1778806605059,"version":"3.51.4"},"reference-count":26,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2014,12,19]],"date-time":"2014-12-19T00:00:00Z","timestamp":1418947200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This work describes the fabrication, characterization, and application of a gold microband array electrode (MAE) for the determination of phosphate in fresh water samples. The working principle of this MAE is based on the reduction of a molybdophosphate complex using the linear sweep voltammetric (LSV) method. The calibration of this microsensor was performed with standard phosphate solutions prepared with KH2PO4 and pH adjusted to 1.0. The microsensor consists of a platinum counter electrode, a gold MAE as working electrode, and an Ag\/AgCl electrode as reference electrode. The microelectrode chips were fabricated by the Micro Electro-Mechanical System (MEMS) technique. To improve the sensitivity, gold nanoparticles (AuNPs) were electrodeposited on the working electrode. With a linear range from 0.02 to 0.50 mg P\/L, the sensitivity of the unmodified microsensor is 2.40 \u00b5A per (mg P\/L) (R2 = 0.99) and that of the AuNPs-modified microsensor is 7.66 \u00b5A per (mg P\/L) (R2 = 0.99). The experimental results showed that AuNPs-modified microelectrode had better sensitivity and a larger current response than the unmodified microelectrode.<\/jats:p>","DOI":"10.3390\/s141224472","type":"journal-article","created":{"date-parts":[[2014,12,19]],"date-time":"2014-12-19T10:50:22Z","timestamp":1418986222000},"page":"24472-24482","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["An Electrochemical Microsensor Based on a AuNPs-Modified Microband Array Electrode for Phosphate Determination  in Fresh Water Samples"],"prefix":"10.3390","volume":"14","author":[{"given":"Fangfang","family":"Wang","sequence":"first","affiliation":[{"name":"State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China"},{"name":"University of Chinese Academy of Sciences, Beijing 100190, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianhua","family":"Tong","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yang","family":"Li","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chao","family":"Bian","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jizhou","family":"Sun","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shanhong","family":"Xia","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2014,12,19]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1039\/ai9953200437","article-title":"Analytical perspective. Techniques for the quantification and speciation of phosphorus in natural waters","volume":"32","author":"McKelvie","year":"1995","journal-title":"Anal. Proc."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1016\/j.saa.2010.11.017","article-title":"A simple spectrophotometric method for the determination of phosphate in soil, detergents, water, bone and food samples through the formation of phosphomolybdate complex followed by its reduction with thiourea","volume":"78","author":"Shyla","year":"2011","journal-title":"Spectrochim. Acta Part A Mole Biomol. Spectrosc."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1134\/S1061934809060082","article-title":"Photometric Cyclic-Injection Determination of Phosphate and Silicate Ions Simultaneously Present in Aqueous Solutions","volume":"64","author":"Bulatov","year":"2009","journal-title":"J. Anal. Chem."},{"key":"ref_4","unstructured":"Strickland, J., and Parson, T. (1972). Practical Handbook of Seawater Analysis, Fisheries Board of Canada."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/j.talanta.2013.03.031","article-title":"Progress and recent advances in phosphate sensors: A review","volume":"114","author":"Adeloju","year":"2013","journal-title":"Talanta"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/S0003-2670(01)84753-X","article-title":"Phosphate-selective electrode based on immobilized alkaline phosphatase and glucose oxidase","volume":"78","author":"Guilbault","year":"1975","journal-title":"Anal. Chim. Acta"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1016\/0003-2670(95)00419-X","article-title":"Development of biosensors based on an electrolyte isolator semiconductor (EIS)\u2014capacitor structure and their application for process monitoring. Part I. Development of the biosensors and their characterization","volume":"317","author":"Menzel","year":"1995","journal-title":"Anal. Chim. Acta"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1677","DOI":"10.1021\/ac00273a032","article-title":"Plant tissue hybrid electrode for determination of phosphate and fluoride","volume":"56","author":"Schubert","year":"1984","journal-title":"Anal. Chem."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2195","DOI":"10.1080\/00032718508067981","article-title":"Electrode hybridepour la determination de phosphates et de polyphosphates. Application aux problemes lies a l'environnement","volume":"18","author":"Linders","year":"1985","journal-title":"Anal. Lett."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1016\/0731-7085(90)80108-2","article-title":"Determination of inorganic phosphate in drug formulations and biological fluids using a plant tissue electrode","volume":"8","author":"Campanella","year":"1990","journal-title":"J. Pharm. Biom. Anal."},{"key":"ref_11","first-page":"1376","article-title":"Electrochemical properties of liquid membranes based on dialkyltin (IV) compounds in phosphorus (V) solutions","volume":"35","author":"Zarinskii","year":"1980","journal-title":"Anal. Chem. USSR"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/S0003-2670(00)84417-7","article-title":"Dialkyltin salts as extractants in methods for the determination of arsenic and phosphorus","volume":"167","author":"Shkinev","year":"1985","journal-title":"Anal. Chim. Acta"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1021\/ac00098a009","article-title":"Surface-modified cobalt-based sensor as a phosphate-sensitive electrode","volume":"67","author":"Xiao","year":"1995","journal-title":"Anal. Chem."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1039\/a700771j","article-title":"Flow-injection potentiometric detection of phosphates using a metallic cobalt wire ion selective electrode","volume":"34","author":"Chen","year":"1997","journal-title":"Anal. Commun."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/S0039-9140(99)00038-7","article-title":"Studies on 1:12 phosphomolybdic heteropoly anion film modified carbon paste electrode","volume":"49","author":"Lu","year":"1999","journal-title":"Talanta"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1311","DOI":"10.1002\/elan.1140091703","article-title":"Microelectrode procedures for the determination of silicate and phosphate in waters\u2014Fundamental studies","volume":"9","author":"Carpenter","year":"1997","journal-title":"Electroanalysis"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1016\/0141-0229(84)90048-6","article-title":"Photomicrobial sensors for selective determination of phoshate","volume":"6","author":"Matsunaga","year":"1984","journal-title":"Enzyme Microb. Technol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1288","DOI":"10.1039\/an9810601288","article-title":"Differential-pulse voltammetric determination of phosphate as molybdovanadophosphate at a glass-carbon electrode and assessment of eluents for the flow-injection voltammetric determination of phosphate, silicon, arsenate and germinate","volume":"106","author":"Fogg","year":"1981","journal-title":"Analyst"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"2218","DOI":"10.1021\/ac00276a053","article-title":"Determination of ortho-phosphate by flow-injection analysis with amperometric detection","volume":"56","author":"Harden","year":"1984","journal-title":"Anal. Chem."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.talanta.2011.09.056","article-title":"Phosphate determination in seawater: Toward an autonomous electrochemical method","volume":"87","author":"Thouron","year":"2011","journal-title":"Talanta"},{"key":"ref_21","unstructured":"Bai, Y., Tong, J., Bian, C., and Xia, S. (2013, January 7\u201310). An Electrochemical Microsensor Based on Molybdophosphate Complex for Fast Determination of Total Phosphorus in Water. Suzhou, China."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1049\/iet-nbt.2013.0041","article-title":"Electrochemical microsensor based on gold nanoparticles modified electrode for total phosphorus determinations in water","volume":"8","author":"Bai","year":"2014","journal-title":"IET Nanobiotechnol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"4676","DOI":"10.1016\/S1452-3981(23)18357-X","article-title":"Catalytic application of gold nanoparticles electrodeposited by fast scan cyclic voltammetry to glycerol electrooxidation in alkaline electrolyte","volume":"6","author":"Etesami","year":"2011","journal-title":"Int. J. Electrochem. Sci."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1480","DOI":"10.1016\/j.bios.2008.10.007","article-title":"Direct electrodeposition of gold nanoparticles on indium tin oxide surface and its application","volume":"24","author":"Ma","year":"2009","journal-title":"Biosens. Bioelectron."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.electacta.2011.10.101","article-title":"Influence of the gold nanoparticles electrodeposition method on Hg (II) trace electrochemical detection","volume":"73","author":"Hezard","year":"2012","journal-title":"Electrochim. Acta"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.jelechem.2008.12.008","article-title":"Electrodeposition of gold nanoparticles on ITO: Control of morphology and plasmon resonance-based absorption and scattering","volume":"628","author":"Sakai","year":"2009","journal-title":"J. Electroanal. Chem."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/12\/24472\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:11:19Z","timestamp":1760217079000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/14\/12\/24472"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,12,19]]},"references-count":26,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2014,12]]}},"alternative-id":["s141224472"],"URL":"https:\/\/doi.org\/10.3390\/s141224472","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,12,19]]}}}