{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,17]],"date-time":"2026-11-17T03:17:15Z","timestamp":1794885435511,"version":"4.9.1"},"reference-count":33,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2014,12,23]],"date-time":"2014-12-23T00:00:00Z","timestamp":1419292800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100008530","name":"European Regional Development Fund","doi-asserted-by":"publisher","award":["CZ.1.05\/1.1.00\/02.0068"],"award-info":[{"award-number":["CZ.1.05\/1.1.00\/02.0068"]}],"id":[{"id":"10.13039\/501100008530","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Label-free immunosensors are well suited for detection of microorganisms because of their fast response and reasonable sensitivity comparable to infection doses of common pathogens. Active (lever oscillator and frequency counter) and passive (impedance analyzer) modes of quartz crystal microbalance (QCM) were used and compared for rapid detection of three strains of E. coli. Different approaches for antibody immobilization were compared, the immobilization of reduced antibody using Sulfo\u2011SMCC was most effective achieving the limit of detection (LOD) 8 \u00d7 104 CFU\u00b7mL\u22121 in 10 min. For the passive mode, software evaluating impedance characteristics in real-time was developed and used. Almost the same results were achieved using both active and passive modes confirming that the sensor properties are not limited by the frequency evaluation method but mainly by affinity of the antibody. Furthermore, reference measurements were done using surface plasmon resonance. Effect of condition of cells on signal was observed showing that cells ruptured by ultrasonication provided slightly higher signal changes than intact microbes.<\/jats:p>","DOI":"10.3390\/s150100079","type":"journal-article","created":{"date-parts":[[2014,12,23]],"date-time":"2014-12-23T15:33:56Z","timestamp":1419348836000},"page":"79-92","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":40,"title":["Rapid Detection of Microorganisms Based on Active and Passive Modes of QCM"],"prefix":"10.3390","volume":"15","author":[{"given":"Zden\u011bk","family":"Farka","sequence":"first","affiliation":[{"name":"CEITEC MU, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Kov\u00e1\u0159","sequence":"additional","affiliation":[{"name":"CEITEC MU, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Petr","family":"Skl\u00e1dal","sequence":"additional","affiliation":[{"name":"CEITEC MU, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic"},{"name":"Department of Biochemistry, Faculty of Science, Masaryk University, Kotl\u00e1\u0159sk\u00e1 2,  611 37 Brno, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2014,12,23]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"74","DOI":"10.3747\/co.2007.110","article-title":"Pierre Curie 1859\u20131906","volume":"14","author":"Mould","year":"2007","journal-title":"Curr. Oncol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1007\/BF01337937","article-title":"Verwendung von schwingquarzen zur w\u00e4gung d\u00fcnner schichten und zur mikrow\u00e4gung","volume":"155","author":"Sauerbrey","year":"1959","journal-title":"Z. Phys."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1770","DOI":"10.1021\/ac00285a062","article-title":"Frequency of a quartz microbalance in contact with liquid","volume":"57","author":"Kanazawa","year":"1985","journal-title":"Anal. Chem."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1016\/0924-4247(96)80161-0","article-title":"Extensions of the quartz-crystal-microbalance technique","volume":"53","author":"Mecea","year":"1996","journal-title":"Sens. Actuators A Phys."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1007\/5346_029","article-title":"Piezoelectric immunosensors","volume":"Volume 5","author":"Janshoff","year":"2007","journal-title":"Piezoelectric Sensors"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1002\/jmr.826","article-title":"A survey of the 2001 to 2005 quartz crystal microbalance biosensor literature: Applications of acoustic physics to the analysis of biomolecular interactions","volume":"20","author":"Cooper","year":"2007","journal-title":"J. Mol. Recognit."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"754","DOI":"10.1002\/jmr.1117","article-title":"A survey of the 2001 to 2005 quartz crystal microbalance biosensor literature","volume":"24","author":"Becker","year":"2011","journal-title":"J. Mol. Recognit."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1002\/jmr.2209","article-title":"A survey of the 2010 quartz crystal microbalance literature","volume":"25","author":"Speight","year":"2012","journal-title":"J. Mol. Recognit."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"370","DOI":"10.3390\/s8010370","article-title":"A review of interface electronic systems for AT-cut quartz crystal microbalance applications in liquids","volume":"8","author":"Arnau","year":"2008","journal-title":"Sensors"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"4004","DOI":"10.1002\/1521-3773(20001117)39:22<4004::AID-ANIE4004>3.0.CO;2-2","article-title":"Piezoelectric mass-sensing devices as biosensors\u2014An alternative to optical biosensors?","volume":"39","author":"Janshoff","year":"2000","journal-title":"Angew. Chem. Int. Ed."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1016\/j.talanta.2013.06.034","article-title":"Real-time and sensitive detection of Salmonella typhimurium using an automated quartz crystal microbalance (QCM) instrument with nanoparticles amplification","volume":"115","author":"Salam","year":"2013","journal-title":"Talanta"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1214","DOI":"10.1080\/00032719.2012.673095","article-title":"Development of piezoelectric immunosensor for the detection of probiotic bacteria","volume":"45","author":"Szalontai","year":"2012","journal-title":"Anal. Lett."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1007\/s00216-012-6172-7","article-title":"Immunodetection of inactivated Francisella tularensis bacteria by using a quartz crystal microbalance with dissipation monitoring","volume":"404","author":"Kleo","year":"2012","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"3395","DOI":"10.1007\/s00216-014-7769-9","article-title":"Bacterial interactions with proteins and cells relevant to the development of life-threatening endocarditis studied by use of a quartz-crystal microbalance","volume":"406","author":"Krajewski","year":"2014","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1016\/j.mimet.2012.05.003","article-title":"Detection and identification of methicillin resistant and sensitive strains of Staphylococcus aureus using tandem measurements","volume":"90","author":"Guntupalli","year":"2012","journal-title":"J. Microbiol. Methods"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1007\/s00604-008-0024-3","article-title":"Detection of pathogenic Staphylococcus aureus bacteria by gold based immunosensors","volume":"163","author":"Boujday","year":"2008","journal-title":"Microchim. Acta"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.mimet.2014.05.025","article-title":"Direct and fast detection of Alexandrium. minutum algae by using high frequency microbalance","volume":"104","author":"Sousa","year":"2014","journal-title":"J. Microbiol. Methods"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"7656","DOI":"10.3390\/s110807656","article-title":"Development of a mass sensitive quartz crystal microbalance (QCM)-based DNA biosensor using a 50 MHz electronic oscillator circuit","volume":"11","author":"Bustabad","year":"2011","journal-title":"Sensors"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"840","DOI":"10.1016\/j.bios.2005.01.021","article-title":"A QCM immunosensor for Salmonella detection with simultaneous measurements of resonant frequency and motional resistance","volume":"21","author":"Su","year":"2005","journal-title":"Biosens. Bioelectron."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/j.aca.2010.12.018","article-title":"Label-free capacitive immunosensor based on quartz crystal Au electrode for rapid and sensitive detection of Escherichia coli O157:H7","volume":"687","author":"Li","year":"2011","journal-title":"Anal. Chim. Acta"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1016\/j.tibtech.2009.09.003","article-title":"Acoustic wave biosensors: Physical models and biological applications of quartz crystal microbalance","volume":"27","author":"Ferreira","year":"2009","journal-title":"Trends Biotechnol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1007\/s00216-003-2080-1","article-title":"Cell spreading on quartz crystal microbalance elicits positive frequency shifts indicative of viscosity changes","volume":"377","author":"Marxer","year":"2003","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2237","DOI":"10.1021\/ac902012e","article-title":"Positive frequency shifts observed upon adsorbing micron-sized solid objects to a quartz crystal microbalance from the liquid phase","volume":"82","author":"Pomorska","year":"2010","journal-title":"Anal. Chem."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"7460","DOI":"10.1016\/j.electacta.2008.01.096","article-title":"Interaction of BSA protein with copper evaluated by electrochemical impedance spectroscopy and quartz crystal microbalance","volume":"53","author":"Pinto","year":"2008","journal-title":"Electrochim. Acta"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1016\/S0956-5663(99)00043-3","article-title":"Comparison of chemical cleaning methods of glass in preparation for silanization","volume":"14","author":"Cras","year":"1999","journal-title":"Biosens. Bioelectron."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/S1452-3981(23)14005-3","article-title":"Piezoelectric and surface plasmon resonance biosensors for Bacillus atrophaeus spores","volume":"8","author":"Farka","year":"2013","journal-title":"Int. J. Electrochem. Sci."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"8680","DOI":"10.1021\/ac501623m","article-title":"Detection of aerosolized biological agents using the piezoelectric immunosensor","volume":"86","author":"Farka","year":"2014","journal-title":"Anal. Chem."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"3837","DOI":"10.1016\/j.matlet.2006.12.043","article-title":"In-situ examination of the selective etching of an alkanethiol monolayer covered Au {111} surface","volume":"61","year":"2007","journal-title":"Mater. Lett."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"3376","DOI":"10.1016\/j.bios.2010.12.035","article-title":"QCM immunosensor detection of Escherichia coli O157:H7 based on beacon immunomagnetic nanoparticles and catalytic growth of colloidal gold","volume":"26","author":"Shen","year":"2011","journal-title":"Biosens. Bioelectron."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.bios.2012.05.024","article-title":"A piezoelectric immunosensor for specific capture and enrichment of viable pathogens by quartz crystal microbalance sensor, followed by detection with antibody-functionalized gold nanoparticles","volume":"38","author":"Guo","year":"2012","journal-title":"Biosens. Bioelectron."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1491","DOI":"10.1007\/s00216-005-3350-x","article-title":"Enzyme-catalyzed amplified immunoassay for the detection of Toxoplasma gondii-specific IgG using faradaic impedance spectroscopy, CV and QCM","volume":"382","author":"Ding","year":"2005","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"11564","DOI":"10.1016\/S1452-3981(23)16968-9","article-title":"A signal-amplified piezoelectric sensor for the detection of hs-CRP using HRP doped magnetic core-shell Fe3O4@SiO2@Au nanostructures as labels","volume":"7","author":"Gan","year":"2012","journal-title":"Int. J. Electrochem. Sci."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"8345","DOI":"10.1021\/ac301904x","article-title":"Bacterial pathogen surface plasmon resonance biosensor advanced by long range surface plasmons and magnetic nanoparticle assays","volume":"84","author":"Wang","year":"2012","journal-title":"Anal. Chem."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/15\/1\/79\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:11:34Z","timestamp":1760217094000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/15\/1\/79"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,12,23]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2015,1]]}},"alternative-id":["s150100079"],"URL":"https:\/\/doi.org\/10.3390\/s150100079","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,12,23]]}}}