{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,27]],"date-time":"2026-09-27T02:38:11Z","timestamp":1790476691183,"version":"4.1.0"},"reference-count":121,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2014,12,30]],"date-time":"2014-12-30T00:00:00Z","timestamp":1419897600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Clinical analyses benefit world-wide from rapid and reliable diagnostics tests. New tests are sought with greatest demand not only for new analytes, but also to reduce costs, complexity and lengthy analysis times of current techniques. Among the myriad of possibilities available today to develop new test systems, amperometric biosensors are prominent players\u2014best represented by the ubiquitous amperometric-based glucose sensors. Electrochemical approaches in general require little and often enough only simple hardware components, are rugged and yet provide low limits of detection. They thus offer many of the desirable attributes for point-of-care\/point-of-need tests. This review focuses on investigating the important integration of sample preparation with (primarily electrochemical) biosensors. Sample clean up requirements, miniaturized sample preparation strategies, and their potential integration with sensors will be discussed, focusing on clinical sample analyses.<\/jats:p>","DOI":"10.3390\/s150100547","type":"journal-article","created":{"date-parts":[[2014,12,30]],"date-time":"2014-12-30T09:42:58Z","timestamp":1419932578000},"page":"547-564","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":61,"title":["Combining Electrochemical Sensors with Miniaturized Sample Preparation for Rapid Detection in Clinical Samples"],"prefix":"10.3390","volume":"15","author":[{"given":"Natinan","family":"Bunyakul","sequence":"first","affiliation":[{"name":"Department of Clinical Chemistry, Faculty of Medical Technology, Mahidol University,  Nakhon Pathom 73170, Thailand"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antje","family":"Baeumner","sequence":"additional","affiliation":[{"name":"Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg,  Regensburg 93053, Germany"},{"name":"Department of Biological and Environmental Engineering, Cornell University, Ithaca,  NY 14853, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2014,12,30]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1111\/j.1749-6632.1962.tb13623.x","article-title":"Electrode systems for continuous monitoring in cardiovascular surgery","volume":"102","author":"Clark","year":"1962","journal-title":"Ann. N. Y. Acad. Sci."},{"key":"ref_2","first-page":"121","article-title":"Electrochemical biosensors: Recommended definitions and classification","volume":"16","author":"Toth","year":"2001","journal-title":"Biosens. Bioelectron."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0009-8981(01)00629-5","article-title":"Immunosensors-principles and applications to clinical chemistry","volume":"314","author":"Luppa","year":"2001","journal-title":"Clin. Chim. Acta"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1016\/j.bios.2010.08.053","article-title":"Electrochemical DNA hybridization sensors applied to real and complex biological samples","volume":"26","author":"Tosar","year":"2010","journal-title":"Biosens. Bioelectron."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1007\/s00216-008-2290-7","article-title":"Acetylcholinesterase-based biosensors for quantification of carbofuran, carbaryl, methylparaoxon, and dichlorvos in 5% acetonitrile","volume":"392","author":"Cortina","year":"2008","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"6019","DOI":"10.1021\/ac000846l","article-title":"Gangliosides as receptors for biological toxins: Development of sensitive fluoroimmunoassays using ganglioside-bearing liposomes","volume":"72","author":"Singh","year":"2000","journal-title":"Anal. Chem."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"814","DOI":"10.1021\/cr068123a","article-title":"Electrochemical glucose biosensors","volume":"108","author":"Wang","year":"2008","journal-title":"Chem. Rev."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"5913","DOI":"10.1021\/ac0258608","article-title":"A disposable, reagentless, third-generation glucose biosensor based on overoxidizedpoly(pyrrole)\/tetrathiafulvalene-Tetracyanoquinodimethane composite","volume":"74","author":"Palmisano","year":"2002","journal-title":"Anal. Chem."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/S0009-8981(03)00241-9","article-title":"Biosensors in clinical chemistry","volume":"334","year":"2003","journal-title":"Clin. Chim. Acta"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"4558","DOI":"10.3390\/s100504558","article-title":"Glucose biosensors: An overview of use in clinical practice","volume":"10","author":"Yoo","year":"2010","journal-title":"Sensors"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1172","DOI":"10.1016\/j.trac.2010.07.008","article-title":"Review of analytical figures of merit of sensors and biosensors in clinical applications","volume":"29","author":"Justino","year":"2010","journal-title":"TrAC Trends Anal. Chem."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1749","DOI":"10.1016\/j.cca.2011.06.025","article-title":"Biosensors in clinical chemistry\u20142011 update","volume":"412","year":"2011","journal-title":"Clin. Chim. Acta"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1016\/j.bios.2006.06.036","article-title":"Pathogen detection: A perspective of traditional methods and biosensors","volume":"22","author":"Lazcka","year":"2007","journal-title":"Biosens. Bioelectron."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1586\/14737159.2014.888313","article-title":"Advances and challenges in biosensor-based diagnosis of infectious diseases","volume":"14","author":"Sin","year":"2014","journal-title":"Expert Rev. Mol. Diagn."},{"key":"ref_15","unstructured":"Gander, T.J. (1992). Jane's NBC Protection Equipment, Jane's Information Group, Dept. DSM 238. [5th ed.]."},{"key":"ref_16","unstructured":"Gessler, E. (1986). Biological and Toxin Weapons Today, Oxford University Press for SIPRI."},{"key":"ref_17","unstructured":"World Health Organization (2008). Guidelines for Drinking-Water Quality, Publisher."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1016\/j.snb.2013.03.137","article-title":"Review of biosensors for foodborne pathogens and toxins","volume":"183","author":"Sharma","year":"2013","journal-title":"Sens. Actuators B Chem."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1016\/S0956-5663(99)00039-1","article-title":"Biosensors for detection of pathogenic bacteria","volume":"14","author":"Ivnitski","year":"1999","journal-title":"Biosens. Bioelectron."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1016\/j.electacta.2012.11.005","article-title":"Applications of antibiofouling PEG-coating in electrochemical biosensors for determination of glucose in whole blood","volume":"89","author":"Sun","year":"2013","journal-title":"Electrochim. Acta"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1016\/j.snb.2003.12.005","article-title":"Biocompatibility and interference eliminating property of pullulan acetate\/polyethylene glycol\/heparin membrane for the outer layer of an amperometric glucose sensor","volume":"99","author":"Sung","year":"2004","journal-title":"Sens. Actuators B Chem."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1006\/abio.1999.4134","article-title":"Liposome dehydration on nitrocellulose and its application in a biotin immunoassay","volume":"271","author":"Martorell","year":"1999","journal-title":"Anal. Biochem."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1755","DOI":"10.1128\/JCM.40.5.1755-1760.2002","article-title":"Enhanced enzyme-linked immunosorbent assay for detection of antibodies to virus-like particles of human papillomavirus","volume":"40","author":"Studentsov","year":"2002","journal-title":"J. Clin. Microbiol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/S0003-2670(03)00299-X","article-title":"Optimization and validation of an enzyme immunoassay for the insect growth regulator fenoxycarb","volume":"487","author":"Le","year":"2003","journal-title":"Anal. Chim. Acta"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1002\/(SICI)1098-2825(1998)12:1<14::AID-JCLA3>3.0.CO;2-J","article-title":"Development of an immunoassay specific for the PSA-ACT complex without the problem of high background","volume":"12","author":"Wu","year":"1998","journal-title":"J. Clin. Lab. Anal."},{"key":"ref_26","first-page":"1000207","article-title":"An organic nanoparticle based high signal amplification immunoassay with improvement of nonspecific binding","volume":"5","author":"Wang","year":"2014","journal-title":"J. Nanomed. Nanotechnol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1016\/j.snb.2011.06.032","article-title":"Poly(dimethylsiloxane) microchip-based immunoassay with multiple reaction zones: Toward on-chip multiplex detection platform","volume":"159","author":"Shao","year":"2011","journal-title":"Sens. Actuators B Chem."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1007\/s10544-013-9751-2","article-title":"Microfluidic based immunosensor for detection and purification of carbonylated proteins","volume":"15","author":"Xia","year":"2013","journal-title":"Biomed. Microdevices"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1002\/1521-4109(200205)14:9<627::AID-ELAN627>3.0.CO;2-G","article-title":"Interferent suppression using a novel polypyrrole-containing hydrogel in amperometric enzyme biosensors","volume":"14","author":"Brahim","year":"2002","journal-title":"Electroanalysis"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/S0003-2670(01)01321-6","article-title":"Amperometric determination of cholesterol in serum using a biosensor of cholesterol oxidase contained within a polypyrrole-hydrogel membrane","volume":"448","author":"Brahim","year":"2001","journal-title":"Anal. Chim. Acta"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.biotechadv.2010.10.002","article-title":"Advances in carbon nanotube based electrochemical sensors for bioanalytical applications","volume":"29","author":"Vashist","year":"2011","journal-title":"Biotechnol. Adv."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.jelechem.2013.01.033","article-title":"Voltammetric method optimized by multi-response assays for the simultaneous measurements of uric acid and acetaminophen in urine in the presence of surfactant using MWCNT paste electrode","volume":"696","author":"Hudari","year":"2013","journal-title":"J. Electroanal. Chem."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1632","DOI":"10.1039\/C3AN02359A","article-title":"Non-invasive mouthguard biosensor for continuous salivary monitoring of metabolites","volume":"139","author":"Kim","year":"2014","journal-title":"Analyst"},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Prabhakar, A., Kumar, Y.V.B.V., Tripathi, S., and Agrawal, A. (2014). A novel, compact and efficient microchannel arrangement with multiple hydrodynamic effects for blood plasma separation. Microfluid. Nanofluidics.","DOI":"10.1007\/s10404-014-1488-6"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1007\/s00542-008-0663-7","article-title":"Effect of microstructure on blood cell clogging in blood separators based on capillary action","volume":"15","author":"Kim","year":"2009","journal-title":"Microsyst. Technol."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1400","DOI":"10.3390\/s80314000","article-title":"Electrochemical biosensors\u2014Sensor principles and architectures","volume":"8","author":"Grieshaber","year":"2008","journal-title":"Sensors"},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Zhang, X., Ju, H., and Wang, J. (2008). Electrochemical Sensors, Biosensors and Their Biomedical Applications, Academic Press.","DOI":"10.1016\/B978-012373738-0.50005-2"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1007\/s10404-010-0638-8","article-title":"Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins","volume":"10","author":"Choi","year":"2011","journal-title":"Microfluid. Nanofluidics"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.aca.2013.07.067","article-title":"Toward decentralized analysis of mercury (II) in real samples. A critical review on nanotechnology-based methodologies","volume":"800","author":"Botasini","year":"2013","journal-title":"Anal. Chim. Acta"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1039\/B913219H","article-title":"Validation of a centrifugal microfluidic sample lysis and homogenization platform for nucleic acid extraction with clinical samples","volume":"10","author":"Siegrist","year":"2010","journal-title":"Lab Chip"},{"key":"ref_41","unstructured":"Spiegel, H. (1984). Clinical Biochemistry V3: Contemporary Theories and Techniques, Academic Press."},{"key":"ref_42","unstructured":"Herold, K.E. (2009). Lab on a Chip Technology: Fabrication and Microfluidics, Caister Academic Press."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"2435","DOI":"10.1016\/j.bios.2004.11.012","article-title":"Home blood glucose biosensors: A commercial perspective","volume":"20","author":"Newman","year":"2005","journal-title":"Biosens. Bioelectron."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/S0925-4005(98)00145-2","article-title":"A micro-planar amperometric glucose sensor unsusceptible to interference species","volume":"49","author":"Matsumoto","year":"1998","journal-title":"Sens. Actuators B Chem."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/S0956-5663(01)00139-7","article-title":"A long-term lifetime amperometric glucose sensor with a perfluorocarbon polymer coating","volume":"16","author":"Matsumoto","year":"2001","journal-title":"Biosens. Bioelectron."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.bios.2013.08.056","article-title":"A highly sensitive and wide-ranged electrochemical zinc(II) aptasensor fabricated on core-shell SiO2-Pt@meso-SiO2","volume":"52","author":"Li","year":"2014","journal-title":"Biosens. Bioelectron."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1177\/0960327106070463","article-title":"Biosensor assay of neuropathy target esterase in whole blood as a new approach to OPIDN risk assessment: Review of progress","volume":"26","author":"Makhaeva","year":"2007","journal-title":"Hum. Exp. Toxicol."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"1317","DOI":"10.1007\/s11581-013-0852-y","article-title":"Highly sensitive electrochemical detection of dopamine and uric acid on a novel carbon nanotube-modified ionic liquid-nanozeolite paste electrode","volume":"19","author":"Noroozifar","year":"2013","journal-title":"Ionics"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1007\/s00604-005-0362-3","article-title":"Amperometric biosensor coupled to capillary electrophoresis for glucose determination","volume":"150","author":"Chen","year":"2005","journal-title":"Microchim. Acta"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/j.bios.2012.06.005","article-title":"A novel glucose biosensor using bi-enzyme incorporated with peptide nanotubes","volume":"38","author":"Park","year":"2012","journal-title":"Biosens. Bioelectron."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1016\/j.bios.2010.07.060","article-title":"An electrochemical immunosensor for testosterone using functionalized magnetic beads and screen-printed carbon electrodes","volume":"26","author":"Campuzano","year":"2010","journal-title":"Biosens. Bioelectron."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.bios.2013.04.022","article-title":"Amperometric detection of dopamine in human serum by electrochemical sensor based on gold nanoparticles doped molecularly imprinted polymers","volume":"49","author":"Xue","year":"2013","journal-title":"Biosens. Bioelectron."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1016\/j.talanta.2013.01.060","article-title":"Detection and discrimination of alpha-fetoprotein with a label-free electrochemical impedance spectroscopy biosensor array based on lectin functionalized carbon nanotubes","volume":"111","author":"Yang","year":"2013","journal-title":"Talanta"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"165","DOI":"10.3109\/10731199.2012.712045","article-title":"Amperometric carbon paste enzyme electrodes with Fe3O4 nanoparticles and 1,4-Benzoquinone for glucose determination","volume":"41","author":"Erden","year":"2013","journal-title":"Artif. Cells Nanomed. Biotechnol."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/j.bios.2012.06.014","article-title":"The label free picomolar detection of insulin in blood serum","volume":"39","author":"Xu","year":"2013","journal-title":"Biosens. Bioelectron."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"7324","DOI":"10.1021\/ac401281t","article-title":"Ultrasensitive impedimetriclectin biosensors with efficient antifouling properties applied in glycoprofiling of human serum samples","volume":"85","author":"Bertok","year":"2013","journal-title":"Anal. Chem."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.bios.2013.10.018","article-title":"Carbon nanotubes based electrochemical aptasensing platform for the detection of hydroxylated polychlorinated biphenyl in human blood serum","volume":"54","author":"Pilehvar","year":"2014","journal-title":"Biosens. Bioelectron."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"e57681","DOI":"10.1371\/journal.pone.0057681","article-title":"Development of a Biosensor for Detection of Pleural Mesothelioma Cancer Biomarker Using Surface Imprinting","volume":"8","author":"Mathur","year":"2013","journal-title":"PLoS One"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.jcis.2013.11.084","article-title":"Highly sensitive and selective determination of pyrazinamide at poly-l-methionine\/reduced graphene oxide modified electrode by differential pulse voltammetry in human blood plasma and urine samples","volume":"418","author":"Cheemalapati","year":"2014","journal-title":"J. Colloid Interface Sci."},{"key":"ref_60","first-page":"983752","article-title":"Impedance-based miniaturized biosensor for ultrasensitive and fast prostate-specific antigen detection","volume":"2011","author":"Bhansali","year":"2011","journal-title":"J. Sens."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.bios.2013.08.036","article-title":"Copper, zinc superoxide dismutase and nitrate reductase coimmobilizedbienzymatic biosensor for the simultaneous determination of nitrite and nitrate","volume":"52","author":"Madasamy","year":"2014","journal-title":"Biosens. Bioelectron."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/j.bios.2011.12.040","article-title":"Amperometric immunosensor for the determination of IgA deficiency in human serum samples","volume":"33","author":"Katakis","year":"2012","journal-title":"Biosens. Bioelectron."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"1158","DOI":"10.1007\/s11051-012-1158-0","article-title":"A novel enzymatic glucose sensor based on Pt nanoparticles-decorated hollow carbon spheres-modified glassy carbon electrode","volume":"14","author":"Luhana","year":"2012","journal-title":"J. Nanoparticle Res."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1016\/j.bios.2013.06.040","article-title":"Ultrasensitive electrochemical detection of cancer-associated circulating microRNA in serum samples based on DNA concatamers","volume":"50","author":"Hong","year":"2013","journal-title":"Biosens. Bioelectron."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.aca.2006.09.062","article-title":"Development of an immunosensor for the detection of testosterone in bovine urine","volume":"583","author":"Conneely","year":"2007","journal-title":"Anal. Chim. Acta"},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1016\/j.talanta.2013.03.020","article-title":"Graphene-polyanilinenanocomposite based biosensor for detection of antimalarial drug artesunate in pharmaceutical formulation and biological fluids","volume":"111","author":"Radhapyari","year":"2013","journal-title":"Talanta"},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"4655","DOI":"10.1039\/c3tb20923g","article-title":"Nitrogen doped graphenenanosheet supported platinum nanoparticles as high performance electrochemical homocysteine biosensors","volume":"1","author":"Kannan","year":"2013","journal-title":"J. Mater. Chem. B"},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"1553","DOI":"10.1016\/S1872-2040(07)60093-0","article-title":"Electrochemical Immuno-Biosensor for the Rapid Determination of Nuclear Matrix Protein 22 (NMP22) antigen in Urine Samples by Co(III) Phthlocyanine\/Fe3O4\/Au Collide Coimmobilized Electrode","volume":"35","author":"Gan","year":"2007","journal-title":"Chin. J. Anal. Chem."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1016\/j.bios.2012.05.045","article-title":"A novel electrochemical sensor for determination of dopamine based on AuNPs@SiO2 core-shell imprinted composite","volume":"38","author":"Yu","year":"2012","journal-title":"Biosens. Bioelectron."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1016\/j.electacta.2011.10.061","article-title":"Electrochemical synthesis and characterization of a novel thiazole-based copolymer and its application in biosensor","volume":"59","author":"Xue","year":"2012","journal-title":"Electrochim. Acta"},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/j.jelechem.2012.07.031","article-title":"Electrochemical biosensor based on reduced graphene oxide and Au nanoparticles entrapped in chitosan\/silica sol-gel hybrid membranes for determination of dopamine and uric acid","volume":"682","author":"Liu","year":"2012","journal-title":"J. Electroanal. Chem."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.aca.2013.01.045","article-title":"Disposable biosensor based on cathodic electrochemiluminescence of tris(2,2-bipyridine)ruthenium(II) for uric acid determination","volume":"770","year":"2013","journal-title":"Anal. Chim. Acta"},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"1423","DOI":"10.1039\/b821922b","article-title":"Disposable electrochemiluminescent biosensor for lactate determination in saliva","volume":"134","author":"BallestaClaver","year":"2009","journal-title":"Analyst"},{"key":"ref_74","doi-asserted-by":"crossref","unstructured":"Bunyakul, N., Promptmas, C., and Baeumner, A.J. (2014). Microfluidic biosensor for cholera toxin detection in fecal samples. Anal. Bioanal. Chem., in press.","DOI":"10.1007\/s00216-014-7947-9"},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1039\/C1LC20803A","article-title":"Integrated separation of blood plasma from whole blood for microfluidic paper-based analytical devices","volume":"12","author":"Yang","year":"2012","journal-title":"Lab Chip"},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"5011","DOI":"10.1158\/1078-0432.CCR-10-1105","article-title":"Portable filter-based microdevice for detection and characterization of circulating tumor cells","volume":"16","author":"Lin","year":"2010","journal-title":"Clin. Cancer Res."},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1016\/j.bios.2013.10.039","article-title":"A simple and portable device for the quantification of TNF-\u03b1 in human plasma by means of on-chip magnetic bead-based proximity ligation assay","volume":"54","author":"Elizalde","year":"2014","journal-title":"Biosens. Bioelectron."},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"1548","DOI":"10.1039\/b820321k","article-title":"A fully automated immunoassay from whole blood on a disc","volume":"9","author":"Lee","year":"2009","journal-title":"Lab Chip"},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"6213","DOI":"10.1021\/ac4006149","article-title":"Label-free cancer cell separation from human whole blood using inertial microfluidics at low shear stress","volume":"85","author":"Lee","year":"2013","journal-title":"Anal. Chem."},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"2973","DOI":"10.1039\/b908271a","article-title":"Inertial microfluidics for continuous particle separation in spiral microchannels","volume":"9","author":"Kuntaegowdanahalli","year":"2009","journal-title":"Lab Chip"},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"2993","DOI":"10.1039\/C4LC00343H","article-title":"Isolating plasma from blood using a dielectrophoresis-active hydrophoretic device","volume":"14","author":"Yan","year":"2014","journal-title":"Lab Chip"},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1007\/s10404-009-0450-5","article-title":"Hydrodynamic blood plasma separation in microfluidic channels","volume":"8","author":"Dhariwal","year":"2010","journal-title":"Microfluid. Nanofluidics"},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1039\/b501885d","article-title":"Continuous particle separation in a microchannel having asymmetrically arranged multiple branches","volume":"5","author":"Takagi","year":"2005","journal-title":"Lab Chip"},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"938","DOI":"10.1039\/B409139F","article-title":"Separation of lipids from blood utilizing ultrasonic standing waves in microfluidic channels","volume":"129","author":"Petersson","year":"2004","journal-title":"Analyst"},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"1847","DOI":"10.1039\/b811150b","article-title":"Conditioning saliva for use in a microfluidic biosensor","volume":"8","author":"Helton","year":"2008","journal-title":"Lab Chip"},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1109\/TNB.2004.837903","article-title":"Development of a rare cell fractionation device: Application for cancer detection","volume":"3","author":"Mohamed","year":"2004","journal-title":"IEEE Trans. Nanobiosci."},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"922","DOI":"10.1039\/b502930a","article-title":"Isolation of plasma from whole blood using planar microfilters for lab-on-a-chip applications","volume":"5","author":"Crowley","year":"2005","journal-title":"Lab Chip"},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"3765","DOI":"10.1021\/ac060042r","article-title":"Separation of plasma from whole human blood in a continuous cross-flow in a molded microfluidic device","volume":"78","author":"Groisman","year":"2006","journal-title":"Anal. Chem."},{"key":"ref_89","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/j.bios.2007.03.029","article-title":"Rapid, femtomolar bioassays in complex matrices combining microfluidics and magnetoelectronics","volume":"23","author":"Mulvaney","year":"2007","journal-title":"Biosens. Bioelectron."},{"key":"ref_90","doi-asserted-by":"crossref","first-page":"2071","DOI":"10.1039\/b812515e","article-title":"Integrated microfluidic tmRNA purification and real-time NASBA device for molecular diagnostics","volume":"8","author":"Dimov","year":"2008","journal-title":"Lab Chip"},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"15162","DOI":"10.1073\/pnas.1206055109","article-title":"Shaping acoustic fields as a toolset for microfluidic manipulations in diagnostic technologies","volume":"109","author":"Reboud","year":"2012","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_92","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.1039\/c3lc40961a","article-title":"A microfluidic chip integrating DNA extraction and real-time PCR for the detection of bacteria in saliva","volume":"13","author":"Oblath","year":"2013","journal-title":"Lab Chip"},{"key":"ref_93","doi-asserted-by":"crossref","first-page":"9640","DOI":"10.1021\/ac302622v","article-title":"Integrated printed circuit board device for cell lysis and nucleic acid extraction","volume":"84","author":"Marshall","year":"2012","journal-title":"Anal. Chem."},{"key":"ref_94","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1007\/s10404-012-0947-1","article-title":"Integrated microfluidic system for the identification and multiple subtyping of influenza viruses by using a molecular diagnostic approach","volume":"13","author":"Wang","year":"2012","journal-title":"Microfluid. Nanofluidics"},{"key":"ref_95","doi-asserted-by":"crossref","first-page":"2294","DOI":"10.1021\/ac802466g","article-title":"Hybrid capillary-microfluidic device for the separation, lysis, and electrochemical detection of vesicles","volume":"81","author":"Omiatek","year":"2009","journal-title":"Anal. Chem."},{"key":"ref_96","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1021\/ac202599b","article-title":"Polymerase chain reaction-free, sample-to-answer bacterial detection in 30 minutes with integrated cell lysis","volume":"84","author":"Lam","year":"2012","journal-title":"Anal. Chem."},{"key":"ref_97","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1039\/B516401J","article-title":"A microfluidic device for continuous, real time blood plasma separation","volume":"6","author":"Yang","year":"2006","journal-title":"Lab Chip"},{"key":"ref_98","doi-asserted-by":"crossref","first-page":"1373","DOI":"10.1038\/nbt.1507","article-title":"Integrated barcode chips for rapid, multiplexed analysis of proteins in microliter quantities of blood","volume":"26","author":"Fan","year":"2008","journal-title":"Nat. Biotechnol."},{"key":"ref_99","doi-asserted-by":"crossref","first-page":"8280","DOI":"10.1021\/ac9005765","article-title":"Multiorifice flow fractionation: Continuous size-based separation of microspheres using a series of contraction\/expansion microchannels","volume":"81","author":"Park","year":"2009","journal-title":"Anal. Chem."},{"key":"ref_100","doi-asserted-by":"crossref","first-page":"4527","DOI":"10.1038\/srep04527","article-title":"Inertial particle separation by differential equilibrium positions in a symmetrical serpentine micro-channel","volume":"4","author":"Zhang","year":"2014","journal-title":"Sci. Rep."},{"key":"ref_101","doi-asserted-by":"crossref","first-page":"044119","DOI":"10.1063\/1.4818906","article-title":"Vortex-aided inertial microfluidic device for continuous particle separation with high size-selectivity, efficiency, and purity","volume":"7","author":"Wang","year":"2013","journal-title":"Biomicrofluidics"},{"key":"ref_102","doi-asserted-by":"crossref","first-page":"892","DOI":"10.1039\/c2lc40663b","article-title":"Microfluidic inertia enhanced phase partitioning for enriching nucleated cell populations in blood","volume":"13","author":"Parichehreh","year":"2013","journal-title":"Lab Chip"},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"2827","DOI":"10.1039\/c1lc20330d","article-title":"Automated cellular sample preparation using a Centrifuge-on-a-Chip","volume":"11","author":"MacH","year":"2011","journal-title":"Lab Chip"},{"key":"ref_104","doi-asserted-by":"crossref","first-page":"3265","DOI":"10.1039\/c0lc00051e","article-title":"Rapid point-of-care concentration of bacteria in a disposable microfluidic device using meniscus dragging effect","volume":"10","author":"Zhang","year":"2010","journal-title":"Lab Chip"},{"key":"ref_105","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1039\/b509386d","article-title":"Hydrodynamic filtration for on-chip particle concentration and classification utilizing microfluidics","volume":"5","author":"Yamada","year":"2005","journal-title":"Lab Chip"},{"key":"ref_106","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1007\/s10544-007-9055-5","article-title":"Microfluidic devices for size-dependent separation of liver cells","volume":"9","author":"Yamada","year":"2007","journal-title":"Biomed. Microdevices"},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1007\/s10404-011-0785-6","article-title":"Sedimentation pinched-flow fractionation for size- and density-based particle sorting in microchannels","volume":"11","author":"Morijiri","year":"2011","journal-title":"Microfluid. Nanofluidics"},{"key":"ref_108","doi-asserted-by":"crossref","first-page":"5465","DOI":"10.1021\/ac049863r","article-title":"Pinched flow fractionation: Continuous size separation of particles utilizing a laminar flow profile in a pinched microchannel","volume":"76","author":"Yamada","year":"2004","journal-title":"Anal. Chem."},{"key":"ref_109","first-page":"97","article-title":"Lab-on-a-chip sample preparation using laminar fluid diffusion interfaces computational fluid dynamics model results and fluidic verification experiments","volume":"371","author":"Weigl","year":"2001","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_110","doi-asserted-by":"crossref","first-page":"1770","DOI":"10.1039\/c1lc20054b","article-title":"Hybrid electrokinetic manipulation in high-conductivity media","volume":"11","author":"Gao","year":"2011","journal-title":"Lab Chip"},{"key":"ref_111","doi-asserted-by":"crossref","first-page":"1765","DOI":"10.1002\/elps.200800037","article-title":"Alternating current electrokinetic separation and detection of DNA nanoparticles in high-conductance solutions","volume":"29","author":"Krishnan","year":"2008","journal-title":"Electrophoresis"},{"key":"ref_112","doi-asserted-by":"crossref","first-page":"2893","DOI":"10.1039\/c1lc20307j","article-title":"Continuous dielectrophoretic bacterial separation and concentration from physiological media of high conductivity","volume":"11","author":"Park","year":"2011","journal-title":"Lab Chip"},{"key":"ref_113","doi-asserted-by":"crossref","first-page":"5215","DOI":"10.1039\/c2an35707k","article-title":"Electrokinetic focusing and separation of mammalian cells in conductive biological fluids","volume":"137","author":"Gao","year":"2012","journal-title":"Analyst"},{"key":"ref_114","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1039\/B313493H","article-title":"Acoustic control of suspended particles in micro fluidic chips","volume":"4","author":"Nilsson","year":"2004","journal-title":"Lab Chip"},{"key":"ref_115","doi-asserted-by":"crossref","first-page":"4511","DOI":"10.1002\/elps.200700620","article-title":"Recent advances in miniaturized microfluidic flow cytometry for clinical use","volume":"28","author":"Chung","year":"2007","journal-title":"Electrophoresis"},{"key":"ref_116","doi-asserted-by":"crossref","first-page":"5140","DOI":"10.1016\/j.jprot.2012.05.045","article-title":"Toward a standardized saliva proteome analysis methodology","volume":"75","author":"Vitorino","year":"2012","journal-title":"J. Proteomics"},{"key":"ref_117","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.mimet.2009.05.020","article-title":"Microscale sample preparation for PCR of C. difficile infected stool","volume":"78","author":"Gillers","year":"2009","journal-title":"J. Microbiol. Methods"},{"key":"ref_118","doi-asserted-by":"crossref","first-page":"1062","DOI":"10.1016\/j.bios.2010.08.051","article-title":"Disposable immunosensor for human cardiac troponin T based on streptavidin-microsphere modified screen-printed electrode","volume":"26","author":"Silva","year":"2010","journal-title":"Biosens. Bioelectron."},{"key":"ref_119","doi-asserted-by":"crossref","first-page":"1701","DOI":"10.1373\/clinchem.2010.147256","article-title":"Electrochemical immunosensor for simultaneous detection of dual cardiac markers based on a poly(dimethylsiloxane)-gold nanoparticles composite microfluidic chip: A proof of principle","volume":"56","author":"Zhou","year":"2010","journal-title":"Clin. Chem."},{"key":"ref_120","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1039\/C0LC00403K","article-title":"Stand-alone self-powered integrated microfluidic blood analysis system (SIMBAS)","volume":"11","author":"Dimov","year":"2011","journal-title":"Lab Chip"},{"key":"ref_121","first-page":"147","article-title":"Drug Testing in Oral Fluid","volume":"27","author":"Drummer","year":"2006","journal-title":"Clin. Biochem. Rev."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/15\/1\/547\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T21:11:53Z","timestamp":1760217113000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/15\/1\/547"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,12,30]]},"references-count":121,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2015,1]]}},"alternative-id":["s150100547"],"URL":"https:\/\/doi.org\/10.3390\/s150100547","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,12,30]]}}}