{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:22:40Z","timestamp":1760242960508,"version":"build-2065373602"},"reference-count":18,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2015,1,13]],"date-time":"2015-01-13T00:00:00Z","timestamp":1421107200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>In the paper, an opportunity for the development of multichannel transcutaneous raster matrixes for sensors of oxygen on the basis of an electrochemical cell sensor is described. An analysis of the influence of heat sources on the distribution of the temperature pattern of a raster matrix for sensors of oxygen had been carried out, and their optimum configuration had been found. The application of such matrixes will enable one to obtain information about the distribution of the partial pressure of oxygen from the skin cover of the object of research in dynamics, to assess its functional health pattern in a more comprehensive way and to control the effect of possible remedial actions.<\/jats:p>","DOI":"10.3390\/s150101404","type":"journal-article","created":{"date-parts":[[2015,1,13]],"date-time":"2015-01-13T11:28:59Z","timestamp":1421148539000},"page":"1404-1416","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Physico-Mathematical Simulation of a Homogeneous Thermal Field of Multichannel Raster Matrixes for Sensors of Oxygen"],"prefix":"10.3390","volume":"15","author":[{"given":"Vitalij","family":"Kotovskyi","sequence":"first","affiliation":[{"name":"Department of Applied Physics, National Technical University of Ukraine \"KPI\", Peremogy av. 37, 03224 Kiev, Ukraine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yurii","family":"Dzhezherya","sequence":"additional","affiliation":[{"name":"Department of Applied Physics, National Technical University of Ukraine \"KPI\", Peremogy av. 37, 03224 Kiev, Ukraine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aleksandr","family":"Dovzhenko","sequence":"additional","affiliation":[{"name":"Department of Applied Physics, National Technical University of Ukraine \"KPI\", Peremogy av. 37, 03224 Kiev, Ukraine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nikolaj","family":"Vi\u0161niakov","sequence":"additional","affiliation":[{"name":"Department of Materials Science and Welding, Vilnius Gediminas Technical University,  J. Basanavi\u010diaus str. 28, LT-03221 Vilnius, Lithuania"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"And\u017eela","family":"\u0160e\u0161ok","sequence":"additional","affiliation":[{"name":"Department of Biomechanics, Vilnius Gediminas Technical University, J. Basanavi\u010diaus str. 28, LT-03221 Vilnius, Lithuania"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2015,1,13]]},"reference":[{"key":"ref_1","unstructured":"Sherwood, L. (2009). Human Physiology: From Cells to Systems, Cengage Learning. [7th ed.]."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/0141-0229(90)90035-O","article-title":"Determination of oxygen profiles in biocatalyst particles by means of a combined polarographic oxygen microsensor","volume":"12","author":"Hooijmans","year":"1990","journal-title":"Enzym. Microb. Technol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/S0034-5687(01)00306-1","article-title":"Tissue oxygen tension and brain sensitivity to hypoxia","volume":"128","author":"Silver","year":"2001","journal-title":"Respir. Physiol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1016\/S0925-4005(03)00441-6","article-title":"Wearable and flexible oxygen sensor for transcutaneous oxygen monitoring","volume":"95","author":"Mitsubayashi","year":"2003","journal-title":"Sens. Actuators B Chem."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1111","DOI":"10.1016\/S0140-6736(80)91556-1","article-title":"Transcutaneous estimation of arterial pO2 and pCO2 in newborn infants with a single elektrochemical sensor","volume":"315","author":"Whitehead","year":"1980","journal-title":"Lancet"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"143","DOI":"10.3109\/03091909109023701","article-title":"Developments in transcutaneous blood gas monitoring: A review","volume":"15","author":"Rithalia","year":"1991","journal-title":"J. Med. Eng. Technol."},{"key":"ref_7","unstructured":"Transcutaneous Monitoring. Available online: http:\/\/www.radiometer.com."},{"key":"ref_8","first-page":"34","article-title":"Measurement of pO2 using a micromachined oxygen electrode","volume":"15","author":"Suzuki","year":"1999","journal-title":"Chem. Sens. B"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/S0003-2670(00)01325-8","article-title":"Determination of blood pO2 using a micromachined Clark-type oxygen electrode","volume":"431","author":"Suzuki","year":"2001","journal-title":"Anal. Chim. Acta"},{"key":"ref_10","first-page":"76","article-title":"\u041ba\u0432po\u0432c\u043aa\u044f, B.\u041f. \u041aoppe\u043a\u0446\u0438\u044f \u043fo\u0433pe\u0448\u043doc\u0442\u0438 a\u0432\u0442o\u043fo\u0442pe\u0431\u043be\u043d\u0438\u044f \u043a\u0438c\u043bopo\u0434\u043do\u0433o \u044d\u043be\u043a\u0442po\u0434a \u041a\u043bap\u043aa","volume":"18","year":"2008","journal-title":"Hay\u0447\u043doe \u041fp\u0438\u0431opoc\u0442poe\u043d\u0438e"},{"key":"ref_11","unstructured":"Stouffer, G., and Gutterman, D. (2011). Cardiovascular Hemodynamics for the Clinician, Wiley-Blackwell."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2585","DOI":"10.1152\/ajpheart.2000.279.6.H2585","article-title":"Prologue: New insights into the regulation of the coronary microcirculation","volume":"48","author":"Chilian","year":"2000","journal-title":"Am. J. Physiol. Heart Circ. Physio l."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1006\/mvre.1997.2055","article-title":"Oxygen transport by erythrocyte\/hemoglobin solution mixtures in an in vitro capillary as a model of hemoglobin-based oxygen carrier performance","volume":"55","author":"Page","year":"1998","journal-title":"Microvasc. Res."},{"key":"ref_14","first-page":"3","article-title":"Co\u0432pe\u043ce\u043d\u043d\u044be \u043fpe\u0434c\u0442a\u0432\u043be\u043d\u0438\u044f o \u0442pa\u043dc\u043fop\u0442e \u043a\u0438c\u043bopo\u0434a \u0438\u0437 \u043apo\u0432\u0438 \u0432 \u0442\u043aa\u043d\u0438","volume":"32","year":"2001","journal-title":"\u0423c\u043fex\u0438 \u0424\u0438\u0437. Hay\u043a"},{"key":"ref_15","unstructured":"\u041ao\u0442o\u0432c\u043a\u0438\u0439, B.\u0418., \u0414o\u0432\u0436e\u043d\u043ao, A.\u041f., and Po\u0439, B.B. (2009). Oco\u0431e\u043d\u043doc\u0442\u0438 pa\u0437pa\u0431o\u0442\u043a\u0438 \u0442pa\u043dc\u043ay\u0442a\u043d\u043do\u0439 ce\u043dcop\u043do\u0439 \u044f\u0447e\u0439\u043a\u0438 \u0434\u043b\u044f \u0437a\u0434a\u0447 \u043c\u043do\u0433o\u043aa\u043da\u043b\u044c\u043do\u0439 \u043a\u0438c\u043bopo\u0434o\u043ce\u0442p\u0438\u0438. \u042d\u043be\u043a\u0442po\u043d\u0438\u043aa \u0438 c\u0432\u044f\u0437\u044c. Te\u043ca\u0442\u0438\u0447ec\u043a\u0438\u0439 \u0432\u044b\u043fyc\u043a \u201c\u042d\u043be\u043a\u0442po\u043d\u0438\u043aa \u0438 \u043da\u043do\u0442ex\u043do\u043bo\u0433\u0438\u0438\u201d. 2, 236\u2013240. (In Russian)."},{"key":"ref_16","first-page":"149","article-title":"Po\u0437po\u0431\u043aa \u043fp\u0438c\u0442po\u044e \u0434\u043b\u044f \u0434oc\u043bi\u0434\u0436e\u043d\u043d\u044f \u0433a\u0437oo\u0431\u043ci\u043d\u043d\u0438x \u043fpo\u0446eci\u0432 \u0431io\u043bo\u0433i\u0447\u043d\u0438x o\u0431`\u0454\u043a\u0442i\u0432","volume":"39","year":"2010","journal-title":"Bic\u043d\u0438\u043a HT\u0423\u0423 \u041a\u041fI, Cepi\u044f \u041fp\u0438\u043ba\u0434o\u0431y\u0434y\u0432a\u043d\u043d\u044f"},{"key":"ref_17","first-page":"215","article-title":"B\u0438\u0437\u043da\u0447e\u043d\u043d\u044f xapa\u043a\u0442epy \u043dec\u0442a\u0431i\u043b\u044c\u043doc\u0442i ce\u043dcopi\u0432 \u043a\u0438c\u043d\u044e","volume":"2","year":"2010","journal-title":"A\u043a\u0442ya\u043b\u044c\u043d\u044be \u0432o\u043fpoc\u044b \u0442eope\u0442\u0438\u0447ec\u043ao\u0439 \u0438 \u043fp\u0438\u043a\u043ba\u0434\u043do\u0439 \u0431\u0438o\u0444\u0438\u0437\u0438\u043a\u0438, \u0444\u0438\u0437\u0438\u043a\u0438 \u0438 x\u0438\u043c\u0438\u0438"},{"key":"ref_18","unstructured":"Tikhonov, A.N., and Samarskii, A.A. (2011). Equations of Mathematical Physics, Dover Publications."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/15\/1\/1404\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:41:34Z","timestamp":1760215294000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/15\/1\/1404"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,1,13]]},"references-count":18,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2015,1]]}},"alternative-id":["s150101404"],"URL":"https:\/\/doi.org\/10.3390\/s150101404","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2015,1,13]]}}}