{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T13:37:37Z","timestamp":1791207457603,"version":"4.1.0"},"reference-count":39,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2015,1,15]],"date-time":"2015-01-15T00:00:00Z","timestamp":1421280000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003032","name":"ANRT","doi-asserted-by":"publisher","award":["1222\/2012"],"award-info":[{"award-number":["1222\/2012"]}],"id":[{"id":"10.13039\/501100003032","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Analyzing human poses with a Kinect is a promising method to evaluate potentials risks of musculoskeletal disorders at workstations. In ecological situations, complex 3D poses and constraints imposed by the environment make it difficult to obtain reliable kinematic information. Thus, being able to predict the potential accuracy of the measurement for such complex 3D poses and sensor placements is challenging in classical experimental setups. To tackle this problem, we propose a new evaluation method based on a virtual mannequin. In this study, we apply this method to the evaluation of joint positions (shoulder, elbow, and wrist), joint angles (shoulder and elbow), and the corresponding RULA (a popular ergonomics assessment grid) upper-limb score for a large set of poses and sensor placements. Thanks to this evaluation method, more than 500,000 configurations have been automatically tested, which would be almost impossible to evaluate with classical protocols. The results show that the kinematic information obtained by the Kinect software is generally accurate enough to fill in ergonomic assessment grids. However inaccuracy strongly increases for some specific poses and sensor positions. Using this evaluation method enabled us to report configurations that could lead to these high inaccuracies. As a supplementary material, we provide a software tool to help designers to evaluate the expected accuracy of this sensor for a set of upper-limb configurations. Results obtained with the virtual mannequin are in accordance with those obtained from a real subject for a limited set of poses and sensor placements.<\/jats:p>","DOI":"10.3390\/s150101785","type":"journal-article","created":{"date-parts":[[2015,1,15]],"date-time":"2015-01-15T09:54:54Z","timestamp":1421315694000},"page":"1785-1803","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":100,"title":["Pose Estimation with a Kinect for Ergonomic Studies: Evaluation of the Accuracy Using a Virtual Mannequin"],"prefix":"10.3390","volume":"15","author":[{"given":"Pierre","family":"Plantard","sequence":"first","affiliation":[{"name":"M2S Laboratory, University Rennes 2, ENS Rennes, Avenue Robert Schuman, 35170 Bruz, France"},{"name":"FAURECIA Automotive Seating, ZI de Bri\u00e8res les Scell\u00e9s, B.P. 89 91152 Etampes, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edouard","family":"Auvinet","sequence":"additional","affiliation":[{"name":"Ecole Polytechnique de Montr\u00e9al, C.P. 6079, Succursale Centre-ville, Montr\u00e9al, H3C 3A7 QC, Canada"},{"name":"CHU Sainte Justine de Montr\u00e9al, 3175, Chemin de la C\u00f4te-Sainte-Catherine, Montr\u00e9al,  H3T1C5 QC, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anne-Sophie","family":"Pierres","sequence":"additional","affiliation":[{"name":"FAURECIA Automotive Seating, ZI de Bri\u00e8res les Scell\u00e9s, B.P. 89 91152 Etampes, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Franck","family":"Multon","sequence":"additional","affiliation":[{"name":"M2S Laboratory, University Rennes 2, ENS Rennes, Avenue Robert Schuman, 35170 Bruz, France"},{"name":"INRIA, MimeTIC team, Campus Universitaire de Beaulieu, 35042 Rennes, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2015,1,15]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1080\/001401399185388","article-title":"Comparison of methods for the assessment of postural load on the back","volume":"42","author":"Li","year":"1999","journal-title":"Ergonomics"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"425","DOI":"10.5271\/sjweh.1679","article-title":"Current techniques for assessing physical exposure to work-related musculoskeletal risks, with emphasis on posture-based methods","volume":"17","author":"Burdorf","year":"1991","journal-title":"Scand. J. Work. Environ. Health"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"208","DOI":"10.5271\/sjweh.1481","article-title":"Validity of self-reported exposures to work postures and manual materials handling. Stockholm MUSIC I Study Group","volume":"19","author":"Wiktorin","year":"1993","journal-title":"Scand. J. Work. Environ. Health"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/0003-6870(93)90080-S","article-title":"RULA: A survey method for the investigation of work-related upper limb disorders","volume":"24","author":"McAtamney","year":"1993","journal-title":"Appl. Ergon."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1093\/occmed\/kqi082","article-title":"Ergonomic methods for assessing exposure to risk factors for work-related musculoskeletal disorders","volume":"55","author":"David","year":"2005","journal-title":"Occup. Med."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/0003-6870(92)90154-N","article-title":"Measurement of trunk bending during work by direct observation and continuous measurement","volume":"23","author":"Burdorf","year":"1992","journal-title":"Appl. Ergon."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/S0169-8141(03)00065-9","article-title":"A computerized video coding system for biomechanical analysis of lifting tasks","volume":"32","author":"Chang","year":"2003","journal-title":"Int. J. Ind. Ergonom."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1649","DOI":"10.1080\/00140139408964942","article-title":"A system for evaluating the effect of keyboard design on force, posture, comfort, and productivity","volume":"37","author":"Smutz","year":"1994","journal-title":"Ergonomics"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/0268-0033(90)90005-Q","article-title":"Three-dimensional kinematics of the human back","volume":"5","author":"Hindle","year":"1990","journal-title":"Clin. Biomech."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1007\/BF02345361","article-title":"Validity and reliability of triaxial accelerometers for inclinometry in posture analysis","volume":"39","author":"Hansson","year":"2001","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1016\/S0003-6870(02)00072-8","article-title":"A triaxial accelerometer for measuring arm movements","volume":"33","author":"Bernmark","year":"2002","journal-title":"Appl. Ergon."},{"key":"ref_12","unstructured":"Freedman, B., Shpunt, A., Machline, M., and Arieli, Y. (2010). Depth Mapping Using Projected Patterns. (U.S. Patent 2010\/0118123)."},{"key":"ref_13","unstructured":"Shpunt, A. (2010). Depth Mapping Using Multi-Beam Illumination. (U.S. Patent 2010\/0020078)."},{"key":"ref_14","unstructured":"Spektor, E., Mor, Z., and Rais, D. (2010). Integrated Processor for 3D Mapping. (U.S. Patent 2010\/0007717)."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Shotton, J., Fitzgibbon, A., Cook, M., Sharp, T., Finocchio, M., Moore, R., Kipman, A., and Blake, A. (2011, January 20\u201325). Real-time human pose recognition in parts from single depth images. Providence, RI, USA.","DOI":"10.1109\/CVPR.2011.5995316"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1016\/j.gaitpost.2012.03.033","article-title":"Validity of the Microsoft Kinect for assessment of postural control","volume":"36","author":"Clark","year":"2012","journal-title":"Gait Posture"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2722","DOI":"10.1016\/j.jbiomech.2013.08.011","article-title":"Concurrent validity of the Microsoft Kinect for assessment of spatiotemporal gait variables","volume":"46","author":"Clark","year":"2013","journal-title":"J. Biomech."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1016\/j.gaitpost.2013.09.018","article-title":"Validity and Reliability of the Kinect within Functional Assessment Activities: Comparison with Standard Stereophotogrammetry","volume":"39","author":"Jansen","year":"2014","journal-title":"Gait Posture"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"16955","DOI":"10.3390\/s140916955","article-title":"Whole Body Center of Mass Estimation with Portable Sensors: Using the Statically Equivalent Serial Chain and a Kinect","volume":"14","author":"Hayashibe","year":"2014","journal-title":"Sensors"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1016\/j.apergo.2011.09.011","article-title":"Evaluation of the Kinect sensor for 3-D kinematic measurement in the workplace","volume":"43","author":"Dutta","year":"2012","journal-title":"Appl. Ergon."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Rafibakhsh, N., Gong, J., Siddiqui, M.K., Gordon, C., and Lee, H.F. (2012, January 21\u201323). Analysis of XBOX Kinect Sensor Data for Use on Construction Sites: Depth Accuracy and Sensor Interference Assessment. West Lafayette, IN, USA.","DOI":"10.1061\/9780784412329.086"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1437","DOI":"10.3390\/s120201437","article-title":"Accuracy and resolution of Kinect depth data for indoor mapping applications","volume":"12","author":"Khoshelham","year":"2012","journal-title":"Sensors"},{"key":"ref_23","unstructured":"Obdr\u017e\u00e1lek, \u0160., Kurillo, G., Ofli, F., Bajcsy, R., Seto, E., Jimison, H., and Pavel, M. (September, January 28). Accuracy and Robustness of Kinect Pose Estimation in the Context of Coaching of Elderly Population. San Diego, CA, USA."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"641","DOI":"10.3233\/THC-130764","article-title":"Evaluation of upper extremity reachable workspace using Kinect camera","volume":"21","author":"Kurillo","year":"2013","journal-title":"Technol. Health Care"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Fern\u00e1ndez-Baena, A., Sus\u00edn, A., and Lligadas, X. (2012, January 19\u201321). Biomechanical Validation of Upper-Body and Lower-Body Joint Movements of Kinect Motion Capture Data for Rehabilitation Treatments. Bucharest, Romania.","DOI":"10.1109\/iNCoS.2012.66"},{"key":"ref_26","first-page":"976","article-title":"Using Kinect\u2122 sensor in observational methods for assessing postures at work","volume":"45","year":"2013","journal-title":"Appl. Ergon."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Martin, C.C., Burkert, D.C., Choi, K.R., Wieczorek, N.B., McGregor, P.M., Herrmann, R.A., and Beling, P.A. (2012, January 27). A Real-Time Ergonomic Monitoring System Using the Microsoft Kinect. Charlottesville, VA, USA.","DOI":"10.1109\/SIEDS.2012.6215130"},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Haggag, H., Hossny, M., Nahavandi, S., and Creighton, D. (2013, January 10\u201312). Real Time Ergonomic Assessment for Assembly Operations Using Kinect. Cambridge, UK.","DOI":"10.1109\/UKSim.2013.105"},{"key":"ref_29","unstructured":"B\u00f3, A.P.L., Hayashibe, M., and Poignet, P. (September, January 30). Joint Angle Estimation in Rehabilitation with Inertial Sensors and its Integration with Kinect. Boston, MA, USA."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Penelle, B., and Debeir, O. (2013, January 11\u201313). Human Motion Tracking for Rehabilitation Using Depth Images and Particle Filter Optimization. Tripoli, Lebanon.","DOI":"10.1109\/ICABME.2013.6648885"},{"key":"ref_31","unstructured":"MakeHuman Available online: http:\/\/www.makehuman.org."},{"key":"ref_32","unstructured":"Blender Available online: http:\/\/www.blender.org."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"981","DOI":"10.1016\/j.jbiomech.2004.05.042","article-title":"International Society of Biomechanics. ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion\u2014Part II: Shoulder, elbow, wrist and hand","volume":"38","author":"Wu","year":"2005","journal-title":"J. Biomech."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1386","DOI":"10.1080\/00140130410001724255","article-title":"Towards understanding the workspace of human limbs","volume":"47","author":"Yang","year":"2004","journal-title":"Ergonomics"},{"key":"ref_35","unstructured":"Bernard, B.P. (1997). Musculoskeletal Disorders and Workplace Factors: A Critical Review of Epidemiologic Evidence for Work-Related Musculoskeletal Disorders of the Neck, Upper Extremity, and Low Back, US Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health."},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Auvinet, E., Multon, F., Aubin, C.E., Meunier, J., and Raison, M. (2014). Detection of gait cycles in treadmill walking using a Kinect. Gait Posture, in press.","DOI":"10.1016\/j.gaitpost.2014.08.006"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1111\/1467-8659.00393","article-title":"Using an Intermediate Skeleton and Inverse Kinematics for Motion Retargeting","volume":"19","author":"Monzani","year":"2000","journal-title":"Comput. Graph. Forum."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Bonnech\u00e8re, B., Sholukha, V., Moiseev, F., Rooze, M., and van Sint Jan, S. (2013, January 27\u201329). From Kinect\u2122 to anatomically-correct motion modelling: Preliminary results for human application. Amsterdam, The Netherlands.","DOI":"10.1007\/978-3-658-02897-8_2"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1016\/j.apergo.2012.11.008","article-title":"Innovative system for real-time ergonomic feedback in industrial manufacturing","volume":"44","author":"Vignais","year":"2012","journal-title":"Appl. Ergon."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/15\/1\/1785\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:41:40Z","timestamp":1760215300000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/15\/1\/1785"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,1,15]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2015,1]]}},"alternative-id":["s150101785"],"URL":"https:\/\/doi.org\/10.3390\/s150101785","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,1,15]]}}}