{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,22]],"date-time":"2026-11-22T13:42:19Z","timestamp":1795354939257,"version":"4.10.3"},"reference-count":91,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2015,2,2]],"date-time":"2015-02-02T00:00:00Z","timestamp":1422835200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Recent advances in integrated biosensors, wireless communication and power harvesting techniques are enticing researchers into spawning a new breed of point-of-care (POC) diagnostic devices that have attracted significant interest from industry. Among these, it is the ones equipped with wireless capabilities that drew our attention in this review paper. Indeed, wireless POC devices offer a great advantage, that of the possibility of exerting continuous monitoring of biologically relevant parameters, metabolites and other bio-molecules, relevant to the management of various morbid diseases such as diabetes, brain cancer, ischemia, and Alzheimer\u2019s. In this review paper, we examine three major categories of miniaturized integrated devices, namely; the implantable Wireless  Bio-Sensors (WBSs), the wearable WBSs and the handheld WBSs. In practice, despite the aforesaid progress made in developing wireless platforms, early detection of health imbalances remains a grand challenge from both the technological and the medical points of view. This paper addresses such challenges and reports the state-of-the-art in this interdisciplinary field.<\/jats:p>","DOI":"10.3390\/s150203236","type":"journal-article","created":{"date-parts":[[2015,2,2]],"date-time":"2015-02-02T10:27:36Z","timestamp":1422872856000},"page":"3236-3261","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":101,"title":["Wireless Integrated Biosensors for Point-of-Care  Diagnostic Applications"],"prefix":"10.3390","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7090-2304","authenticated-orcid":false,"given":"Ebrahim","family":"Ghafar-Zadeh","sequence":"first","affiliation":[{"name":"Department of Electrical Engineering and Computer Sciences, Lassonde School of Engineering,  York University, Toronto, ON M3J1P3, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2015,2,2]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1097\/CCM.0b013e3181c6697a","article-title":"Infection control in mass respiratory failure: Preparing to respond to H1N1","volume":"38","author":"Elizabeth","year":"2010","journal-title":"Crit. Care Med."},{"key":"ref_2","first-page":"1033","article-title":"Update on bacterial nosocomial infections","volume":"16","author":"Bereket","year":"2012","journal-title":"Eur. Rev. Med. Pharmacol. Sci."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1038\/nature10242","article-title":"An integrated semiconductor device enabling non-optical genome sequencing","volume":"475","author":"Rothberg","year":"2011","journal-title":"Nature"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1089\/dia.2005.7.788","article-title":"Real-Time Continuous Glucose Monitor Use and Patient Selection: What Have We Learned and Where Are We Going?","volume":"7","author":"Darrell","year":"2005","journal-title":"Diabetes Technol. Ther."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1001\/jama.2013.284986","article-title":"FDA Approval of Cardiac Implantable Electronic Devices via Original and Supplement Premarket Approval Pathways, 1979\u20132012","volume":"311","author":"Benjamin","year":"2014","journal-title":"JAMA"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1038\/nbt0414-301","article-title":"Epilepsy neurodevice approved","volume":"32","author":"Proffitt","year":"2014","journal-title":"Nat. Biotechnol."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Lewitus, D.Y., Smith, K.L., Landers, J., Neimark, A.V., and Kohn, J. (2014). Bioactive agarose carbon-nanotube composites are capable of manipulating brain-implant interface. J. Appl. Polym. Sci., 131.","DOI":"10.1002\/app.40297"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1616","DOI":"10.1021\/nl500070h","article-title":"Long Term Stability of Nanowire Nanoelectronics in Physiological Environments","volume":"14","author":"Zhou","year":"2014","journal-title":"Nano Lett."},{"key":"ref_9","unstructured":"Sargolzaei, A., Yen, K.K., and Abdelghani, M.N. (2014). Control of Nonlinear Heartbeat Models under Time-Delay-Switched Feedback Using Emotional Learning Control. Int. J. Recent Trends Eng. Technol., 10, 01.IJRTET.10.2.38."},{"key":"ref_10","unstructured":"St. Jude Medical Has Acquired a California Company that Makes a Wireless Pacemaker. Available online: http:\/\/www.startribune.com\/business\/227471071.html."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1016\/j.parkreldis.2013.12.012","article-title":"Effect of frequency on subthalamic nucleus deep brain stimulation in primary dystonia","volume":"20","author":"Ostrem","year":"2014","journal-title":"Park. Relat. Disord."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1012","DOI":"10.1046\/j.1464-5491.2003.01037.x","article-title":"Performance assessment of the Medtronic-MiniMed continuous glucose monitoring system and its use for measurement of glycaemic control in type 1 diabetic","volume":"20","author":"Sachedina","year":"2003","journal-title":"Diabet. Med."},{"key":"ref_13","unstructured":"Medtronic Inc. Available online: http:\/\/www.medtronic.ca."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Mahfouz, M.R., Kuhn, M.J., and To, G. (2013, January 20\u201323). Wireless medical devices: A review of current research and commercial systems. Austin, TX, USA.","DOI":"10.1109\/BioWireleSS.2013.6613660"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2202","DOI":"10.1109\/TPDS.2012.320","article-title":"An Energy Efficient Key Management Scheme for Body Sensor Networks","volume":"24","author":"Zhao","year":"2012","journal-title":"IEEE Trans. Parallel Distrib. Syst."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1002\/elan.201200349","article-title":"Wearable electrochemical sensors and biosensors: A review","volume":"25","author":"Windmiller","year":"2013","journal-title":"Electroanalysis"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1126\/science.1250169","article-title":"Soft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin","volume":"344","author":"Xu","year":"2014","journal-title":"Science"},{"key":"ref_18","unstructured":"Vital Connect Inc. Available online: http:\/\/www.vitalconnect.com."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"6494","DOI":"10.1039\/C4AN01612B","article-title":"A 3D-printed device for smartphone-based chemiluminescence biosensor for lactate in oral fluid and sweat","volume":"139","author":"Roda","year":"2014","journal-title":"Analyst"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1902","DOI":"10.1021\/ac4040168","article-title":"Evaluation of Commercial Glucometer Test Strips for Potential Measurement of Glucose in Tears","volume":"83","author":"Cha","year":"2014","journal-title":"Anal. Chem."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"856","DOI":"10.1038\/nbt0914-856","article-title":"Novartis signs up for Google smart lens","volume":"32","author":"Senior","year":"2014","journal-title":"Nat. Biotechnol."},{"key":"ref_22","unstructured":"Emergency Inflight Diagnosis with e+ Patch. Available online: http:\/\/Www.Yankodesign.Com\/2014\/03\/19\/Emergency-Inflight-Diagnosis-With-E-Patch\/."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Mannoor, M.S., Tao, H., Clayton, J.D., Sengupta, A., Kaplan, D.L., Naik, R.R., Verma, N., Omenetto, F.G., and McAlpine, M.C. (2014). Graphene-based wireless bacteria detection on tooth enamel. Nat. Commun., 3.","DOI":"10.1038\/ncomms1767"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1038\/nbt.1780","article-title":"Implantable magnetic relaxation sensors measure cumulative exposure to cardiac biomarkers","volume":"29","author":"Ling","year":"2011","journal-title":"Nat. Biotechnol."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Gou, P., Kraut, N.D., Feigel, I.M., Bai, H., Morgan, G.J., Chen, Y., Tang, Y., Bocan, K., Stachel, J., and Berger, L. (2014). Carbon Nanotube Chemiresistor for Wireless pH Sensing. Sci. Rep., 4.","DOI":"10.1038\/srep04468"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"967","DOI":"10.1007\/s10544-010-9451-0","article-title":"Handheld impedance biosensor system using engineered proteinaceous receptors","volume":"12","author":"Chowdhury","year":"2010","journal-title":"Biomed. Microdevices"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/j.jim.2006.05.006","article-title":"A novel magnetic bead bioassay platform using a microchip-based sensor for infectious disease diagnosis","volume":"314","author":"Aytura","year":"2006","journal-title":"J. Immunol. Methods"},{"key":"ref_28","unstructured":"PHILIPS Available online: http:\/\/www.newscenter.philips.com\/main\/standard\/about\/news\/press\/20081120_magnotech.wpd."},{"key":"ref_29","unstructured":"Novabiomedical. Available online: http:\/\/www.novabiomedical.com\/products\/statstrip-glucose-statstrip-xpress-glucose\/."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1038\/nmeth.2520","article-title":"Simultaneous DNA amplification and detection using a pH-sensing semiconductor system","volume":"10","author":"Toumazou","year":"2013","journal-title":"Nat. Methods"},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Ma, H., Wallbank, R.W.R., Chaji, R., Li, J., Suzuki, Y., Jiggins, C., and Nathan, A. (2013). An impedance-based integrated biosensor for suspended DNA characterization. Sci. Rep., 3.","DOI":"10.1038\/srep02730"},{"key":"ref_32","unstructured":"Oxford Nanopore Available online: https:\/\/www.nanoporetech.com."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Park, D.H., Han, C.J., Shul, Y.G., and Choy, J.H. (2014). Avatar DNA Nanohybrid System in Chip-on-a-Phone. Sci. Rep., 4.","DOI":"10.1038\/srep04879"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1109\/JSSC.2006.869785","article-title":"A 0.18-\u03bcm CMOS bioluminescence detection lab-on-chip","volume":"41","author":"Eltoukhy","year":"2006","journal-title":"IEEE J. Solid State Circuits"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1290","DOI":"10.1109\/JSSC.2013.2245058","article-title":"A 256 Pixel Magnetoresistive Biosensor Microarray in 0.18 \u03bcm CMOS","volume":"48","author":"Hall","year":"2013","journal-title":"IEEE J. Solid State Circuits"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1016\/j.snb.2013.02.065","article-title":"High density CMOS electrode array for high-throughput and automated cell counting","volume":"181","author":"Pui","year":"2013","journal-title":"Sens. Actuators B Chem."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1016\/j.bios.2012.02.049","article-title":"Ultrasensitive and label-free detection of pathogenic avian influenza DNA by using CMOS impedimetric sensors","volume":"35","author":"Lai","year":"2012","journal-title":"Biosens. Bioelectron."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"16677","DOI":"10.1073\/pnas.0607693103","article-title":"Single-step electronic detection of femtomolar DNA by target-induced strand displacement in an electrode-bound duplex","volume":"103","author":"Xiao","year":"2006","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_39","unstructured":"Parviz, A.B. (May, January 27). Towards a Functional Contact Lens. Fort Lauderdale, FL, USA."},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Liao, Y.-T., Yao, H., Parviz, B., and Otis, B. (2011, January 20\u201324). A 3 \u03bcW wirelessly powered CMOS glucose sensor for an active contact lens. San Francisco, CA, USA.","DOI":"10.1109\/ISSCC.2011.5746209"},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Ghafar-Zadeh, E., and Sawan, M. (2010). CMOS Capacitive Sensors for Lab-on-Chip Applications: A Mul-Tidisciplinary Approach, Springer.","DOI":"10.1007\/978-90-481-3727-5"},{"key":"ref_42","unstructured":"Hierlemann, A. (2009). Integrated Chemical Microsensor Systems in CMOS-Technology, Springer."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1109\/JSEN.2007.891990","article-title":"A fully electronic label-free DNA sensor chip","volume":"7","author":"Stagni","year":"2006","journal-title":"IEEE J. Sens."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Ahmadi, M.M., and Jullien, G.A. (2009). A wireless-implantable microsystem for continuous blood glucose monitoring. IEEE Trans. Biomed. Circuits Syst., 3.","DOI":"10.1109\/TBCAS.2009.2016844"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1449","DOI":"10.1016\/j.bios.2007.12.015","article-title":"Tracking cancer cell proliferation on a CMOS capacitance sensor chip","volume":"23","author":"Prakashet","year":"2008","journal-title":"Biosens. Bioelectron."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1109\/TBCAS.2010.2048430","article-title":"Bacteria Growth Monitoring Through a Differential CMOS Capacitive Sensor","volume":"4","author":"Sawan","year":"2010","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"1782","DOI":"10.3390\/s100301782","article-title":"Wide Dynamic Range CMOS Potentiostat for Amperometric Chemical Sensor","volume":"10","author":"Wang","year":"2010","journal-title":"Sensors"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Augustyniak, M., Paulus, C., Brederlow, R., and Persike, N. (2006, January 6\u20139). A 24 \u00d7 16 CMOS-based chronocoulometric DNA microarray. San Francisco, CA, USA.","DOI":"10.1109\/ISSCC.2006.1696034"},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Thewes, R., Hofmann, F., Frey, A., and Holzapfl, B. (2002, January 7). Sensor arrays for fully electronic DNA detection on CMOS. San Francisco, CA, USA.","DOI":"10.1109\/ISSCC.2002.993076"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"2438","DOI":"10.1109\/JSSC.2004.837084","article-title":"A fully electronic DNA sensor with 128 positions and in-pixel A\/D conversion","volume":"39","author":"Schienle","year":"2004","journal-title":"IEEE J. Solid State Circuits"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1995","DOI":"10.1016\/j.bios.2008.10.012","article-title":"Real-time, multiplexed electro-chemical DNA detection using an active complementary metal-oxide-semiconductor biosensor array with integrated sensor electronics","volume":"24","author":"Lavine","year":"2009","journal-title":"Biosens. Bioelectron."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"1859","DOI":"10.1109\/JSSC.2008.925407","article-title":"Active CMOS sensor array for electrochemical biomolecular detection","volume":"43","author":"Levine","year":"2008","journal-title":"IEEE J. Solid State Circuits"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"1339","DOI":"10.1109\/TCSI.2008.2005927","article-title":"Current-mirror-based potentiostats for three-electrode amperometric electrochemical sensors","volume":"56","author":"Ahmadi","year":"2009","journal-title":"IEEE Trans. Circuits Syst."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1109\/TBCAS.2011.2171339","article-title":"CMOS Amperometric Instrumentation and Packaging for Biosensor Array Applications","volume":"5","author":"Lin","year":"2011","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Yamazaki, T., Ikeda, T., Kano, Y., Takao, H., Ishida, M., and Sawada, K. (2010). Design and Fabrication of Complementary Metal-Oxide-Semiconductor Sensor Chip for Electrochemical Measurement. J. App. Phys., 49.","DOI":"10.1143\/JJAP.49.04DL11"},{"key":"ref_56","first-page":"1414","article-title":"A digital CMOS-based 24 \u00d7 16 sensor array platform for fully automatic electrochemical DNA detection","volume":"26","author":"Kruppa","year":"2010","journal-title":"Biosensors"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1109\/JSEN.2009.2020193","article-title":"CMOS micro-electrode array for electrochemical lab-on-a-chip applications","volume":"9","author":"Hwang","year":"2009","journal-title":"IEEE Sens. J."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"1380","DOI":"10.1109\/JSEN.2006.883904","article-title":"A Programmable 0.18-CMOS Electrochemical Sensor Microarray for Biomolecular Detection","volume":"6","author":"Hassibi","year":"2006","journal-title":"IEEE J. Sens."},{"key":"ref_59","unstructured":"Lai, W.A., Lin, C.H., Yang, Y.S., and Lu, M.S.C. (February, January 29). Ultrasensitive detection of avian influenza virus by using CMOS impedimetric sensor arrays. Paris, France."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"2956","DOI":"10.1109\/JSSC.2006.884867","article-title":"CMOS DNA sensor array with integrated A\/D conversion based on label-free capacitance measurement","volume":"41","author":"Stagni","year":"2006","journal-title":"IEEE J. Solid State Circuits"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1109\/JSEN.2008.917485","article-title":"A charge based capacitive sensor array for Lab-on-Chip applications","volume":"8","author":"Sawan","year":"2008","journal-title":"IEEE J. Sens."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1109\/TBCAS.2010.2089794","article-title":"CMOS Conductometric System for Growth Monitoring and Sensing of Bacteria","volume":"3","author":"Yao","year":"2011","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"3927","DOI":"10.1021\/ja01480a001","article-title":"Acid-base equilibria in acetonitrile\u2014Spectrophotometric and conductometric determination of dissociation of various acids","volume":"83","author":"Kolthoff","year":"1961","journal-title":"J. Am. Chem. Soc."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.fm.2007.07.005","article-title":"Immunosensors for rapid detection of Escherichia coli O157:H7 perspectives for use in the meat processing industry","volume":"25","author":"Tokarskyy","year":"2008","journal-title":"Food Microbiol."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0925-4005(02)00301-5","article-title":"Thirty years of ISFETOLOGY: What happened in the past 30 years and what may happen in the next 30 years","volume":"88","author":"Bergveld","year":"2003","journal-title":"Sens. Actuators B Chem."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/0250-6874(81)80004-2","article-title":"The operation of an ISFET as electronic device","volume":"1","author":"Bergveld","year":"1981","journal-title":"Sens. Actuators"},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/S0925-4005(99)00135-5","article-title":"Ions-sensitive field effect transistors fabricated in a commercial CMOS technology","volume":"57","author":"Bausells","year":"1999","journal-title":"Sens. Actuators B Chem."},{"key":"ref_68","first-page":"347","article-title":"A large transistor-based sensor array chip for direct extracellular imaging","volume":"111\u2013112","author":"Georgiou","year":"2005","journal-title":"Sens. Actuators B Chem."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1016\/S0956-5663(01)00202-0","article-title":"Development of ISFET array-based microsystems for bioelectrochemical measurements of cell populations","volume":"16","author":"Martinoia","year":"2001","journal-title":"Biosens. Bioelectron."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/S0925-4005(97)80004-4","article-title":"An H+-FET-based system for on-line detection of microorganisms in waters","volume":"34","author":"Cambiaso","year":"1996","journal-title":"Sens. Actuators B Chem."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"964","DOI":"10.1016\/j.snb.2005.06.069","article-title":"Protons and single nucleotide polymorphism detection: A simple use for the Ion Sensitive Field Effect Transistor","volume":"114","author":"Purushothaman","year":"2006","journal-title":"Sens. Actuators B Chem."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"1912","DOI":"10.1002\/elan.200403080","article-title":"Detection of DNA and Protein Molecules Using an FET-Type Biosensor with Gold as a Gate Metal","volume":"16","author":"Shin","year":"2004","journal-title":"Electroanalysis"},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"2108","DOI":"10.1016\/j.bios.2006.09.025","article-title":"A fully electronic sensor for the measurement of cDNA hybridization kinetics","volume":"22","author":"Bandiera","year":"2007","journal-title":"Biosens. Bioelectron."},{"key":"ref_74","doi-asserted-by":"crossref","unstructured":"Garner, D.M., Bai, H., Georgiou, P., Constandinou, T.G., Reed, S., Shepherd, L.M., Wong, W., Lim, K.T., and Toumazou, C. (2010, January 7\u201311). A multichannel DNA sensor for rapid point-of-care gene detection. San Francisco, CA, USA.","DOI":"10.1109\/ISSCC.2010.5433834"},{"key":"ref_75","doi-asserted-by":"crossref","unstructured":"Kalofonou, M., and Toumazou, C. (2014, January 1\u20135). An ISFET based analogue ratiometric method for DNA methylation detection. Melbourne, Australia.","DOI":"10.1109\/ISCAS.2014.6865514"},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1016\/j.mejo.2006.05.001","article-title":"New ISFET interface circuit design with temperature compensation","volume":"37","author":"Chung","year":"2006","journal-title":"J. Microelectron."},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1109\/TBME.2005.844041","article-title":"A system-on-chip digital pH meter for use in a wireless diagnostic capsule","volume":"52","author":"Hammond","year":"2005","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1109\/JSEN.2004.836849","article-title":"Design of a single-chip pH sensor using a conventional 0.6-\u03bcm CMOS process","volume":"4","author":"Hammond","year":"2004","journal-title":"IEEE J. Sens."},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/S0925-4005(99)00136-7","article-title":"New ISFET sensor interface circuit for biomedical applications","volume":"57","author":"Santosa","year":"1999","journal-title":"Sens. Actuators B Chem."},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1049\/el:20051044","article-title":"Differential read-out architecture for CMOS ISFET microsystems","volume":"41","author":"Chodavarapu","year":"2005","journal-title":"Electron. Lett."},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/S0925-4005(99)00242-7","article-title":"A simple REFET for pH detection in differential mode","volume":"60","author":"Errachid","year":"1999","journal-title":"Sens. Actuators B Chem."},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1016\/j.snb.2004.11.006","article-title":"Weak inversion ISFETs for ultra-low power biochemical sensing and real-time analysis","volume":"107","author":"Shepherd","year":"2005","journal-title":"Sens. Actuators B Chem."},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"2614","DOI":"10.1109\/TCSI.2005.857919","article-title":"A biochemical translinear principle with weak inversion ISFETs","volume":"52","author":"Shepherd","year":"2005","journal-title":"IEEE Trans. Circuits Syst."},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1049\/el.2009.0152","article-title":"Chemical log-domain filter","volume":"45","author":"Georgiou","year":"2009","journal-title":"Electron. Lett."},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"1112","DOI":"10.1049\/el.2009.2310","article-title":"ISFET threshold voltage programming in CMOS using hot-electron injection","volume":"45","author":"Georgiou","year":"2009","journal-title":"Electron. Lett."},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"1398","DOI":"10.1049\/el.2011.3057","article-title":"ISFET threshold voltage programming in CMOS using electron tunneling","volume":"47","author":"Toumazou","year":"2011","journal-title":"Electron. Lett."},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.1049\/el:20082268","article-title":"CMOS-based programmable gate ISFET","volume":"44","author":"Georgiou","year":"2008","journal-title":"Electron. Lett."},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/S0925-4005(00)00473-1","article-title":"Low frequency noise and drift in ion sensitive field effect transistors","volume":"68","author":"Jakobson","year":"2000","journal-title":"Sens. Actuators B Chem."},{"key":"ref_89","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1109\/16.737468","article-title":"1\/f noise in ion sensitive field effect transistors from subthreshold to saturation","volume":"49","author":"Jakobson","year":"1999","journal-title":"IEEE Trans. Electron. Devices"},{"key":"ref_90","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.snb.2013.02.096","article-title":"An LTCC-based microfluidic system for label-free, electrochemical detection of cortisol","volume":"182","author":"Vasudev","year":"2013","journal-title":"Sens. Actuators B Chem."},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.bios.2014.06.053","article-title":"A Low-Cost Miniaturized Potentiostat for Point-of-Care Diagnosis","volume":"62","author":"Cruz","year":"2014","journal-title":"Biosens. Bioelectron."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/15\/2\/3236\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:42:13Z","timestamp":1760215333000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/15\/2\/3236"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,2,2]]},"references-count":91,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2015,2]]}},"alternative-id":["s150203236"],"URL":"https:\/\/doi.org\/10.3390\/s150203236","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,2,2]]}}}