{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,28]],"date-time":"2026-03-28T11:56:19Z","timestamp":1774698979503,"version":"3.50.1"},"reference-count":28,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2015,2,3]],"date-time":"2015-02-03T00:00:00Z","timestamp":1422921600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"A*STAR AOP project","award":["1223600005"],"award-info":[{"award-number":["1223600005"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Thermal sensors based on thermopiles are some of the most robust and popular temperature sensing technologies across industries and research disciplines. A chip calorimeter with a 3D thermopile layout with a large sensing area and multichannel capacity has been developed, which is highly desired for many applications requiring large reaction chambers or high throughputs, such as biofilm research, drug screening, etc. The performance of the device, including temperature sensitivity and heat power sensitivity, was evaluated. The capability to split the chip calorimeter to multiple channels was also demonstrated, which makes the chip calorimeter very flexible and powerful in many applications.<\/jats:p>","DOI":"10.3390\/s150203351","type":"journal-article","created":{"date-parts":[[2015,2,3]],"date-time":"2015-02-03T09:20:19Z","timestamp":1422955219000},"page":"3351-3361","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["Fabrication and Characterization of a Multichannel 3D Thermopile for Chip Calorimeter Applications"],"prefix":"10.3390","volume":"15","author":[{"given":"Tho","family":"Huynh","sequence":"first","affiliation":[{"name":"School of Mechanical and Aerospace Engineering, Nanyang Technological University,  50 Nanyang Avenue 639798, Singapore"},{"name":"Singapore Centre on Environmental Life Sciences and Engineering, Interdisciplinary Graduate School, Nanyang Technological University, 60 Nanyang Drive 637551, Singapore"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yilei","family":"Zhang","sequence":"additional","affiliation":[{"name":"School of Mechanical and Aerospace Engineering, Nanyang Technological University,  50 Nanyang Avenue 639798, Singapore"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cohen","family":"Yehuda","sequence":"additional","affiliation":[{"name":"Singapore Centre on Environmental Life Sciences and Engineering, Interdisciplinary Graduate School, Nanyang Technological University, 60 Nanyang Drive 637551, Singapore"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2015,2,3]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/0924-4247(93)80011-5","article-title":"CMOS as sensor technology","volume":"37\u201338","author":"Baltes","year":"1993","journal-title":"Sens. Actuators A Phys."},{"key":"ref_2","first-page":"621","article-title":"Integrated thermopile sensors","volume":"23","author":"Herwaarden","year":"1989","journal-title":"Sens. Actuators"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1016\/j.tca.2005.04.027","article-title":"Overview of calorimeter chips for various applications","volume":"432","author":"Herwaarden","year":"2005","journal-title":"Thermochim. Acta"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1007\/s00253-011-3497-7","article-title":"Potentials and limitations of miniaturized calorimeters for bioprocess monitoring","volume":"92","author":"Maskow","year":"2011","journal-title":"Appl. Microbiol. Biotechnol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1339","DOI":"10.1002\/biot.201000287","article-title":"Biofilm research using calorimetry\u2014A marriage made in heaven?","volume":"5","author":"Buchholz","year":"2010","journal-title":"Biotechnol. J."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/j.tca.2005.07.011","article-title":"A new micro-fluid chip calorimeter for biochemical applications","volume":"445","author":"Lerchner","year":"2006","journal-title":"Thermochim. Acta"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1128\/AAC.00583-09","article-title":"Fast and reliable evaluation of bactericidal and bacteriostatic treatment of biofilms using chip calorimetry","volume":"54","author":"Buchholz","year":"2010","journal-title":"Antimicrob. Agents Chemother."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.jlp.2010.07.012","article-title":"Chip-scale calorimeters\u2014Potential use in chemical engineering","volume":"24","author":"Liu","year":"2011","journal-title":"J. Loss Prev. Process Ind."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/j.tca.2008.08.007","article-title":"Nano-calorimetry of small-sized biological samples","volume":"477","author":"Lerchner","year":"2008","journal-title":"Thermochim. Acta"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/j.snb.2009.12.012","article-title":"Binding event measurement using a chip calorimeter coupled to magnetic beads","volume":"145","author":"Ahmad","year":"2010","journal-title":"Sens. Actuators B Chem."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1733","DOI":"10.1016\/j.bios.2004.01.009","article-title":"Calorimetric biosensors with integrated microfluidic channels","volume":"19","author":"Zhang","year":"2004","journal-title":"Biosens. Bioelectron."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2190","DOI":"10.1021\/ac011028b","article-title":"Micromachined nanocalorimetric sensor for ultra-low-volume cell-based assays","volume":"74","author":"Johannessen","year":"2002","journal-title":"Anal. Chem."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1016\/j.sna.2011.03.027","article-title":"Chip calorimeter for thermal characterization of bio-chemical solutions","volume":"167","author":"Adrega","year":"2011","journal-title":"Sens. Actuators A Phys."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.tca.2004.09.010","article-title":"Calorimetry of microbial growth using a thermopile based microreactor","volume":"427","author":"Mas","year":"2005","journal-title":"Thermochim. Acta"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"18041","DOI":"10.1073\/pnas.0901447106","article-title":"High-sensitivity microfluidic calorimeters for biological and chemical applications","volume":"106","author":"Lee","year":"2009","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1038\/nmat943","article-title":"Thermoelectric microdevice fabricated by a MEMS-like electrochemical process","volume":"2","author":"Snyder","year":"2003","journal-title":"Nat. Mater."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Lindeberg, M., Yousef, H., R\u00f6djeg\u00e5rd, H., Martin, H., and Hjort, K. (2008). A PCB-like process for vertically configured thermopiles. J. Micromech. Microeng., 18.","DOI":"10.1088\/0960-1317\/18\/6\/065021"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Huang, I., Chen, G., and Wu, T. (2013). Development of microthermoelectric generators using integrated suspending bridge-type polysilicon thin-film thermopiles. J. Micro. Nano. MEMS MOEMS, 12.","DOI":"10.1117\/1.JMM.12.1.013001"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/S0924-4247(02)00478-8","article-title":"A bulk micromachined silicon thermopile with high sensitivity","volume":"104","author":"Allison","year":"2003","journal-title":"Sens. Actuators A Phys."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1787","DOI":"10.1143\/JJAP.47.1787","article-title":"Fabrication and characterization of a three-dimensional flexible thermopile","volume":"47","author":"Lin","year":"2008","journal-title":"Jpn. J. Appl. Phys."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"9517","DOI":"10.1073\/pnas.0403573101","article-title":"Enthalpy arrays","volume":"101","author":"Torres","year":"2004","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"De Bruyker, D., Wolkin, M., Recht, M., Torres, F., Bell, A., Anderson, G., Peeters, E., Kolatkar, A., Kuhn, P., and Bruce, R. (2007, January 10\u201314). MEMS-based Enthalpy arrays. Lyon, France.","DOI":"10.1109\/SENSOR.2007.4300493"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1007\/s11664-011-1562-8","article-title":"Processing and thermoelectric performance characterization of thin-film devices consisting of electrodeposited bismuth telluride and antimony telluride thin-film legs","volume":"40","author":"Kim","year":"2011","journal-title":"J. Electron. Mater."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.carbon.2013.08.005","article-title":"Effectively decoupling electrical and thermal conductivity of polymer composites","volume":"65","author":"Zhang","year":"2013","journal-title":"Carbon"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Zhang, K., Zhang, Y., and Wang, S. (2013). Enhancing thermoelectric properties of organic composites through hierarchical nanostructures. Sci. Rep., 3.","DOI":"10.1038\/srep03448"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.tca.2006.04.020","article-title":"Chip calorimeters for the investigation of liquid phase reactions: Design rules","volume":"446","author":"Lerchner","year":"2006","journal-title":"Thermochim. Acta"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"9369","DOI":"10.3390\/s101009369","article-title":"Biomedical use of isothermal microcalorimeters","volume":"10","author":"Braissant","year":"2010","journal-title":"Sensors"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.mimet.2008.04.004","article-title":"Miniaturized calorimetry\u2014A new method for real time biofilm analysis","volume":"74","author":"Lerchner","year":"2008","journal-title":"J. Microbiol. Methods"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/15\/2\/3351\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:42:16Z","timestamp":1760215336000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/15\/2\/3351"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,2,3]]},"references-count":28,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2015,2]]}},"alternative-id":["s150203351"],"URL":"https:\/\/doi.org\/10.3390\/s150203351","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,2,3]]}}}