{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T18:10:46Z","timestamp":1791483046373,"version":"4.3.4"},"reference-count":25,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2015,2,4]],"date-time":"2015-02-04T00:00:00Z","timestamp":1423008000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Moisture is an important variable that must be kept under control to guarantee a safe operation of power transformers. Because of the hydrophilic character of cellulose, water mainly remains in the solid insulation, while just a few parts per million are dissolved in oil. The distribution of moisture between paper and oil is not static, but varies depending on the insulation temperature, and thus, water migration processes take place continuously during transformers operation. In this work, a sensor is presented that allows the determination of the moisture content of the transformer solid insulation in the steady state and during the moisture migration processes. The main objective of the design is that the electrodes of the sensor should not obstruct the movement of water from the solid insulation to the oil, so the proposed prototype uses a metallic-mesh electrode to do the measurements. The measurement setup is based on the characterization of the insulation dielectric response by means of the frequency dielectric spectroscopy (FDS) method. The sensitivity of the proposed sensor has been tested on samples with a moisture content within 1% to 5%, demonstrating the good sensitivity and repeatability of the measurements.<\/jats:p>","DOI":"10.3390\/s150203610","type":"journal-article","created":{"date-parts":[[2015,2,4]],"date-time":"2015-02-04T08:25:00Z","timestamp":1423038300000},"page":"3610-3624","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["Development of a Moisture-in-Solid-Insulation Sensor for Power Transformers"],"prefix":"10.3390","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5181-3349","authenticated-orcid":false,"given":"Bel\u00e9n","family":"Garc\u00eda","sequence":"first","affiliation":[{"name":"Department of Electrical Engineering, Universidad Carlos III de Madrid, Avda de la Universidad 30, Legan\u00e9s, Madrid 28911, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Diego","family":"Garc\u00eda","sequence":"additional","affiliation":[{"name":"School of Electrical and Electronic Engineering, Edificio 356 - Ciudad Universitaria, Mel\u00e9ndez, Calle 13 No 100-00, Cali 760032, Colombia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guillermo","family":"Robles","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Universidad Carlos III de Madrid, Avda de la Universidad 30, Legan\u00e9s, Madrid 28911, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2015,2,4]]},"reference":[{"key":"ref_1","unstructured":"Bartley, W. (, January September). Analysis of Transformer Failures, Stockholm, Sweden."},{"key":"ref_2","unstructured":"Working group A2.30 (2008). Moisture Equilibrium and Moisture Migration within Transformer Insulation Systems. Technical Brochure 349, Cigr\u00e9."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1109\/TDEI.2013.6518968","article-title":"Moisture in cellulose insulation of power transformers-statistics","volume":"10","author":"Gielniak","year":"2013","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_4","first-page":"23","article-title":"Preventing Power Transformer Failures through Electrical Incipient Fault Analysis","volume":"9","author":"Bhalla","year":"2013","journal-title":"Int. J. Perform. Eng."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Oommen, T. V. (1983, January 3\u20136). Moisture equilibrium in paper-oil insulation systems. Chicago, IL, USA.","DOI":"10.1109\/EEIC.1983.7465055"},{"key":"ref_6","unstructured":"Griffin, P. J. (1996, January 8\u20139). Water in Transformers-So What!. Surrey, UK."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1109\/57.744585","article-title":"Moisture equilibrium in transformer paper-oil systems","volume":"15","author":"Du","year":"1999","journal-title":"IEEE Electr. Insul. Mag."},{"key":"ref_8","unstructured":"(2006). Guide for Acceptance and Maintenance of Insulating Oil in Equipment, IEEE Std. C57.106-2006, Institute of Electrical and Electronics Engineers."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Hribernik, W., Pascoli, G., and Frohlich, K. (2008, January 9\u201312). An advanced model-based diagnosis system for online detection of the moisture content of power transformer insulation. Vancuveor, BC, Canada.","DOI":"10.1109\/ELINSL.2008.4570307"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1417","DOI":"10.1109\/TPWRD.2004.832366","article-title":"A moisture-in-oil model for power transformer monitoring\u2014Part I: Theoretical foundation","volume":"20","author":"Garcia","year":"2005","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1433","DOI":"10.1109\/TPWRD.2013.2248396","article-title":"Measuring Paper Water Content of Transformers: A New Approach Using Cellulose Isotherms in Nonequilibrium Conditions","volume":"28","author":"Martin","year":"2013","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2574","DOI":"10.1109\/TPWRD.2010.2048343","article-title":"Diagnostic Application of Moisture Equilibrium for Power Transformers","volume":"25","author":"Koch","year":"2010","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_13","unstructured":"Cigre Task Force D1.01.09 (2004). Dielectric Response Methods for Diagnostics of Power Transformers, Cigr\u00e9. Technical Brochure 254."},{"key":"ref_14","unstructured":"Villarroel, R., Garcia, B., Burgos, J.C., and Garcia, D.F. (July, January 30). Experimental study on moisture dynamics in transformers insulated with natural-esters. Bologna, Italy."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1650","DOI":"10.1109\/TDEI.2012.6311512","article-title":"Characteristics of moisture diffusion in vegetable oil-paper insulation","volume":"19","author":"Li","year":"2012","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_16","unstructured":"IEC (2007). Specification for Pressboard and Presspaper for Electrical Purposes\u2014Part 1: Definitions and General Requirements, International Electrotechnical Comission."},{"key":"ref_17","unstructured":"IEC (1997). Insulating Liquids. Oil-Impregnated Paper and Pressboard. Determination of Water by Automatic Coulometric Karl Fishcher Titration, International Electrotechnical Comission."},{"key":"ref_18","unstructured":"(2012). Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Solutions, ASTM E104-02; ASTM International."},{"key":"ref_19","unstructured":"Kelly, J., Myers, S., and Stebbins, R. (2004). Transformer Maintenance Guide, Transformer Maintenance Institute."},{"key":"ref_20","unstructured":"Ekanayake, C. (2006). Diagnosis of Moisture in Transformer Insulation\u2014Application of Frequency Domain Spectroscopy. [Ph.D. Thesis, Chalmers University of Technology]."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Wang, S., Wei, J., Yang, S., Dong, M., and Zhang, G. (2009, January 19\u201323). Temperature and thermal aging effects on the Frequency Domain Spectroscopy measurement of oil-paper insulation. Harbin, China.","DOI":"10.1109\/ICPADM.2009.5252418"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1853","DOI":"10.1109\/TDEI.2010.5658238","article-title":"Investigation on dielectric response characteristics of thermally aged insulating pressboard in vacuum and oil-impregnated ambient","volume":"17","author":"Wang","year":"2010","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Aravinda, G.A., Attaragama, C., Palawatte, I.T., Fernando, M.A., Jayantha, G.A., and Kumara, J.R. (2013, January 17\u201320). Condition monitoring of current transformers using frequency domain dielectric spectroscopy. Kandy, Sri Lanka.","DOI":"10.1109\/ICIInfS.2013.6731975"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1368","DOI":"10.1109\/TDEI.2014.6832285","article-title":"Prediction of moisture present in cellulosic part of power transformer insulation using transfer function of modified debye mode","volume":"21","author":"Baral","year":"2014","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Betie, A., Meghnefi, F., Fofana, I., and Yeo, Z. (2012, January 14\u201317). On the impacts of ageing and moisture on dielectric response of oil impregnated paper insulation systems. Montreal, QC, Canada.","DOI":"10.1109\/CEIDP.2012.6378760"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/15\/2\/3610\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:42:20Z","timestamp":1760215340000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/15\/2\/3610"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,2,4]]},"references-count":25,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2015,2]]}},"alternative-id":["s150203610"],"URL":"https:\/\/doi.org\/10.3390\/s150203610","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,2,4]]}}}