{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T21:54:36Z","timestamp":1763070876758,"version":"build-2065373602"},"reference-count":43,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2015,5,4]],"date-time":"2015-05-04T00:00:00Z","timestamp":1430697600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The classic dynamic clamp technique uses a real-time electrical interface between living cells and neural simulations in order to investigate hypotheses about neural function and structure. One of the acknowledged drawbacks of that technique is the limited control of the cells\u2019 chemical microenvironment. In this manuscript, we use a novel combination of nanosensor and microfluidic technology and microfluidic and neural simulations to add sensing and control of chemical concentrations to the dynamic clamp technique. Specifically, we use a microfluidic lab-on-a-chip to generate distinct chemical concentration gradients (ions or neuromodulators), to register the concentrations with embedded nanosensors and use the processed signals as an input to simulations of a neural cell. The ultimate goal of this project is to close the loop and provide sensor signals to the microfluidic lab-on-a-chip to mimic the interaction of the simulated cell with other cells in its chemical environment.<\/jats:p>","DOI":"10.3390\/s150510465","type":"journal-article","created":{"date-parts":[[2015,5,4]],"date-time":"2015-05-04T10:33:04Z","timestamp":1430735584000},"page":"10465-10480","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Towards a Dynamic Clamp for Neurochemical Modalities"],"prefix":"10.3390","volume":"15","author":[{"given":"Catalina","family":"Rivera","sequence":"first","affiliation":[{"name":"Departments of Mathematics, Washington State University Vancouver, Vancouver, WA 98686, USA"},{"name":"Department of Physics, Emory University, Atlanta, GA 30332, USA"}]},{"given":"Hyuck-Jin","family":"Kwon","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, McMaster University, Hamilton, ON L8S4L8, Canada"}]},{"given":"Ali","family":"Hashmi","sequence":"additional","affiliation":[{"name":"Department of Bioengineering, Stanford University, Stanford, CA 94305, USA"}]},{"given":"Gan","family":"Yu","sequence":"additional","affiliation":[{"name":"Departments of Mechanical Engineering, Washington State University Vancouver, Vancouver, WA 98686, USA"}]},{"given":"Jiheng","family":"Zhao","sequence":"additional","affiliation":[{"name":"Departments of Mechanical Engineering, Washington State University Vancouver, Vancouver, WA 98686, USA"}]},{"given":"Jianlong","family":"Gao","sequence":"additional","affiliation":[{"name":"Departments of Mechanical Engineering, Washington State University Vancouver, Vancouver, WA 98686, USA"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5765-7431","authenticated-orcid":false,"given":"Jie","family":"Xu","sequence":"additional","affiliation":[{"name":"Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6550-5366","authenticated-orcid":false,"given":"Wei","family":"Xue","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Rowan University, Glassboro, NJ 08028, USA"}]},{"given":"Alexander","family":"Dimitrov","sequence":"additional","affiliation":[{"name":"Departments of Mathematics, Washington State University Vancouver, Vancouver, WA 98686, USA"}]}],"member":"1968","published-online":{"date-parts":[[2015,5,4]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/0166-2236(93)90004-6","article-title":"The dynamic clamp: Artificial conductances in biological neurons","volume":"16","author":"Sharp","year":"1993","journal-title":"Trends Neurosci."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"992","DOI":"10.1152\/jn.1993.69.3.992","article-title":"Dynamic Clamp: Computer-Generated Conductances in Real Neurons","volume":"69","author":"Sharp","year":"1993","journal-title":"J. Neurophysiol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1470","DOI":"10.4249\/scholarpedia.1470","article-title":"Dynamic clamp","volume":"6","author":"Prinz","year":"2011","journal-title":"Scholarpedia"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1103\/RevModPhys.77.977","article-title":"Microfluidics: Fluid physics at the nanoliter scale","volume":"77","author":"Squires","year":"2005","journal-title":"Rev. Mod. Phys."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"065020","DOI":"10.1088\/0960-1317\/18\/6\/065020","article-title":"Drop on demand in a microfluidic chip","volume":"18","author":"Xu","year":"2008","journal-title":"J. Micromech. Microeng."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1184","DOI":"10.1038\/nbt876","article-title":"Small-scale systems for in vivo drug delivery","volume":"21","author":"Lavan","year":"2003","journal-title":"Nat. Biotechnol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1039\/c2lc41081h","article-title":"Advances in microfluidics-based experimental methods for neuroscience research","volume":"13","author":"Park","year":"2013","journal-title":"Lab Chip"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.bios.2012.02.012","article-title":"Neuroscience goes on a chip","volume":"35","author":"Soe","year":"2012","journal-title":"Biosens. Bioelectron."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1039\/B813495B","article-title":"Microfluidics: A new cosset for neurobiology","volume":"9","author":"Wang","year":"2009","journal-title":"Lab Chip"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"941","DOI":"10.1007\/s10404-010-0718-9","article-title":"Microfluidic whole-blood immunoassays","volume":"10","author":"Jiang","year":"2011","journal-title":"Microfluid. Nanofluid."},{"key":"ref_11","unstructured":"Xu, J. (2014). Food Chemical Hazard Detection: Development and Application of New Technologies, John Wiley & Sons, Inc."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Bareket-Keren, L., and Hanein, Y. (2012). Carbon nanotube-based multi electrode arrays for neuronal interfacing: Progress and prospects. Front. Neural Circuits.","DOI":"10.3389\/fncir.2012.00122"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1039\/C2LC40954B","article-title":"ntegration of pre-aligned liquid metal electrodes for neural stimulation within a user-friendly microfluidic platform","volume":"13","author":"Hallfors","year":"2013","journal-title":"Lab Chip"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"3296","DOI":"10.1039\/c2lc40303j","article-title":"Multi-compartment neuron-glia co-culture platform for localized CNS axon-glia interaction study","volume":"12","author":"Park","year":"2012","journal-title":"Lab Chip"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1038\/nmeth777","article-title":"A microfluidic culture platform for CNS axonal injury, regeneration and transport","volume":"2","author":"Taylor","year":"2005","journal-title":"Nat. Methods"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1038\/35036035","article-title":"The versatility and universality of calcium signalling","volume":"1","author":"Berridge","year":"2000","journal-title":"Nat. Rev. Mol. Cell Biol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1006\/scdb.2000.0211","article-title":"Calcium signalling\u2014An overview","volume":"12","author":"Bootman","year":"2001","journal-title":"Semin. Cell Dev. Biol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1242\/jcs.01705","article-title":"Another dimension to calcium signaling: A look at extracellular calcium","volume":"118","author":"Hofer","year":"2005","journal-title":"J. Cell Sci."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"330A","DOI":"10.1021\/ac002800y","article-title":"Lab-on-a-chip: A revolution in biological and medical sciences","volume":"72","author":"Figeys","year":"2000","journal-title":"Anal. Chem."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1094","DOI":"10.1039\/b706364b","article-title":"Microfluidic platforms for lab-on-a-chip applications","volume":"7","author":"Haeberle","year":"2007","journal-title":"Lab Chip"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Hashmi, A., Yu, G., Reilly-Collette, M., Heiman, G., and Xu, J. (2012). Oscillating Bubbles: A Versatile Tool for Lab on a Chip Applications. Lab Chip.","DOI":"10.1039\/c2lc40424a"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1146\/annurev.fluid.36.050802.122124","article-title":"Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip","volume":"36","author":"Stone","year":"2004","journal-title":"Ann. Rev. Fluid Mech."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"107002","DOI":"10.1088\/0957-0233\/22\/10\/107002","article-title":"Simple graphene chemiresistors as pH sensors: Fabrication and characterization","volume":"22","author":"Lei","year":"2011","journal-title":"Meas. Sci. Technol."},{"key":"ref_24","first-page":"751","article-title":"Integration of Nanosensors into a Sealed Microchannel in a Hybrid Lab-on-a-Chip Device","volume":"166\u2013167","author":"Li","year":"2012","journal-title":"Sens. Actuators B Chem."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Zhao, J., Sheadel, D.A., and Xue, W. (2012). Surface treatment of polymers for the fabrication of all-polymer MEMS devices. Sens. Actuators A Phys.","DOI":"10.1115\/IMECE2012-86136"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/S0003-2670(99)00056-2","article-title":"Ion sensors: Current limits and new trends","volume":"393","author":"Bakker","year":"1999","journal-title":"Anal. Chim. Acta"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1049\/mnl:20065031","article-title":"Hydrogen and calcium ion electrochemical detecting systems using microfluidic technology","volume":"1","author":"Lin","year":"2006","journal-title":"Micro Nano Lett."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1007\/s11671-010-9604-3","article-title":"Selective Deposition and Alignment of Single-Walled Carbon Nanotubes Assisted by Dielectrophoresis: From Thin Films to Individual Nanotubes","volume":"5","author":"Li","year":"2010","journal-title":"Nanoscale Res. Lett."},{"key":"ref_29","unstructured":"(2006). FLUENT 6.3 User's Guide., Fluent Inc."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"017001","DOI":"10.1088\/0960-1317\/24\/1\/017001","article-title":"Design of a microfluidic device with a non-traditional flow profile for on-chip damage to zebrafish sensory cells","volume":"24","author":"Kwon","year":"2014","journal-title":"J. Micromech. Microeng."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Ermentrout, B., and Terman, D. (2010). Mathematical Foundations of Neuroscience., Springer.","DOI":"10.1007\/978-0-387-87708-2"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1069","DOI":"10.1016\/S0006-3495(96)79653-4","article-title":"Ca2+ buffering and action potential-evoked Ca2+ signaling in dendrites of pyramidal neurons","volume":"70","author":"Helmchen","year":"1996","journal-title":"Biophys. J."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"S38","DOI":"10.5664\/JCSM.1360","article-title":"Biochemical regulation of sleep and sleep biomarkers","volume":"7","author":"Clinton","year":"2011","journal-title":"J. Clin. Sleep Med."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1093\/sleep\/34.3.261","article-title":"Evidence for neuroinflammatory and microglial changes in the cerebral response to sleep loss","volume":"34","author":"Wisor","year":"2011","journal-title":"Sleep"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1177\/2211068214540156","article-title":"On the Quantification of Mixing in Microfluidics","volume":"19","author":"Hashmi","year":"2014","journal-title":"J. Lab. Autom."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1007\/128_2011_150","article-title":"Micromixing within Microfluidic Devices","volume":"304","author":"Capretto","year":"2011","journal-title":"Top. Curr. Chem."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1088\/0960-1317\/17\/3\/025","article-title":"Control and ultrasonic actuation of a gas-liquid interface in a microfluidic chip","volume":"17","author":"Xu","year":"2007","journal-title":"J. Micromech. Microeng."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/0143-4160(90)90061-X","article-title":"Intracellular calibration of the fluorescent calcium indicator Fura-2","volume":"11","author":"Williams","year":"1990","journal-title":"Cell Calcium"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1365","DOI":"10.1016\/j.bios.2005.04.022","article-title":"Development of a novel, multi-analyte biosensor system for assaying cell division: Identification of cell proliferation\/death precursor events","volume":"21","author":"Kintzios","year":"2006","journal-title":"Biosens. Bioelectron."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"8361","DOI":"10.3390\/s8128361","article-title":"Array biosensor for toxin detection: Continued advances","volume":"8","author":"Taitt","year":"2008","journal-title":"Sensors"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"856","DOI":"10.1038\/nbt0901-856","article-title":"Bioassay of prostate-specific antigen (PSA) using microcantilevers","volume":"19","author":"Wu","year":"2001","journal-title":"Nat. Biotechnol."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1887","DOI":"10.1016\/j.bios.2005.10.027","article-title":"Electrochemical biosensors: Towards point-of-care cancer diagnostics","volume":"21","author":"Wang","year":"2006","journal-title":"Biosens. Bioelectron."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1021\/am9007819","article-title":"Immobilizing enzymes onto electrode arrays by hydrogel photolithography to fabricate multi-analyte electrochemical biosensors","volume":"2","author":"Yan","year":"2010","journal-title":"ACS Appl. Mater. Interfaces"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/15\/5\/10465\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:45:44Z","timestamp":1760215544000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/15\/5\/10465"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,5,4]]},"references-count":43,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2015,5]]}},"alternative-id":["s150510465"],"URL":"https:\/\/doi.org\/10.3390\/s150510465","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2015,5,4]]}}}