{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T10:26:17Z","timestamp":1790072777085,"version":"4.0.1"},"reference-count":33,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2015,12,15]],"date-time":"2015-12-15T00:00:00Z","timestamp":1450137600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This paper presents a smart sensing strip for noninvasively monitoring respiratory flow in real time. The monitoring system comprises a monolithically-integrated flexible hot-film flow sensor adhered on a molded flexible silicone case, where a miniaturized conditioning circuit with a Bluetooth4.0 LE module are packaged, and a personal mobile device that wirelessly acquires respiratory data transmitted from the flow sensor, executes extraction of vital signs, and performs medical diagnosis. The system serves as a wearable device to monitor comprehensive respiratory flow while avoiding use of uncomfortable nasal cannula. The respiratory sensor is a flexible flow sensor monolithically integrating four elements of a Wheatstone bridge on single chip, including a hot-film resistor, a temperature-compensating resistor, and two balancing resistors. The monitor takes merits of small size, light weight, easy operation, and low power consumption. Experiments were conducted to verify the feasibility and effectiveness of monitoring and diagnosing respiratory diseases using the proposed system.<\/jats:p>","DOI":"10.3390\/s151229881","type":"journal-article","created":{"date-parts":[[2015,12,15]],"date-time":"2015-12-15T10:09:11Z","timestamp":1450174151000},"page":"31738-31750","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":64,"title":["Smart Sensing Strip Using Monolithically Integrated Flexible Flow Sensor for Noninvasively Monitoring Respiratory Flow"],"prefix":"10.3390","volume":"15","author":[{"given":"Peng","family":"Jiang","sequence":"first","affiliation":[{"name":"State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing 100084, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuai","family":"Zhao","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing 100084, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rong","family":"Zhu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing 100084, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2015,12,15]]},"reference":[{"key":"ref_1","unstructured":"World Health Organization Available online: http:\/\/www.who.int\/mediacentre\/factsheets\/fs310\/en\/."},{"key":"ref_2","first-page":"7","article-title":"Recent Improvements in the Management of Obstructive Sleep Apnea: The Dental Perception","volume":"1","author":"Jain","year":"2015","journal-title":"Int. J. Adv. Health Sci."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.smrv.2014.03.008","article-title":"Cognitive complaints in obstructive sleep apnea","volume":"19","author":"Vaessen","year":"2015","journal-title":"Sleep Med. Rev."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"657","DOI":"10.2337\/diacare.29.03.06.dc05-0879","article-title":"Sleep duration as a risk factor for the development of type 2 diabetes","volume":"29","author":"Yaggi","year":"2006","journal-title":"Diabetes Care"},{"key":"ref_5","unstructured":"National Institutes of Health National Heart, Lung and Blood Institute (NHLBI). Guidelines for the Diagnosis and Management of Asthma (EPR-3), Available online: http:\/\/www.nhlbi.nih.gov\/guidelines\/asthma."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1093\/sleep\/28.4.499","article-title":"Practice parameters for the indications for polysomnography and related procedures: An update for 2005","volume":"28","author":"Kushida","year":"2005","journal-title":"Sleep"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1016\/j.sleep.2012.06.011","article-title":"Is portable monitoring accurate in the diagnosis of obstructive sleep apnea syndrome in chronic pulmonary obstructive disease?","volume":"13","author":"Oliveira","year":"2012","journal-title":"Sleep Med."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1007\/s11325-008-0232-4","article-title":"Evaluation of a portable recording device (apnealink\u2122) for case selection of obstructive sleep apnea","volume":"13","author":"Chen","year":"2009","journal-title":"Sleep Breath."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"737","DOI":"10.5664\/jcsm.27032","article-title":"Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients","volume":"3","author":"Collop","year":"2007","journal-title":"J. Clin. Sleep Med."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1136","DOI":"10.1364\/BOE.5.001136","article-title":"Non-invasive respiratory monitoring using long-period fiber grating sensors","volume":"5","author":"Petrovic","year":"2014","journal-title":"Biomed. Opt. Express."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"3110","DOI":"10.1109\/TBME.2012.2211354","article-title":"A wireless portable system with microsensors for monitoring respiratory diseases","volume":"59","author":"Cao","year":"2012","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1007\/BF02348078","article-title":"Critical review of non-invasive respiratory monitoring in medical care","volume":"41","author":"Folke","year":"2003","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"010901","DOI":"10.1117\/1.JBO.20.1.010901","article-title":"Fiber-optic sensors for monitoring patient physiological parameters: A review of applicable technologies and relevance to use during magnetic resonance imaging procedures","volume":"20","author":"Dziuda","year":"2015","journal-title":"J. Biomed. Opt."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"4378","DOI":"10.1364\/BOE.6.004378","article-title":"Remote monitoring of breathing dynamics using infrared thermography","volume":"6","author":"Pereira","year":"2015","journal-title":"Biomed. Opt. Express"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/j.medengphy.2015.01.010","article-title":"Flow measurement in mechanical ventilation: A review","volume":"37","author":"Schena","year":"2015","journal-title":"Med. Eng. Phys."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1097\/01.PCC.0000059334.04333.1B","article-title":"Correction factors for oxygen and gas flow-rate effects on neonatal Fleisch and Lilly pneumotachographs","volume":"4","author":"Snepvangers","year":"2003","journal-title":"Pediat. Crit. Care Med."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Tardi, G., Massaroni, C., Saccomandi, P., and Schena, E. (2015). Experimental Assessment of a Variable Orifice Flowmeter for Respiratory Monitoring. J. Sens.","DOI":"10.1155\/2015\/752540"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"550","DOI":"10.3390\/mi3030550","article-title":"Micromachined thermal flow sensors\u2014A review","volume":"3","author":"Kuo","year":"2012","journal-title":"Micromachines"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/S0955-5986(97)00019-8","article-title":"Micromachined flow sensors\u2014A review","volume":"8","author":"Nguyen","year":"1997","journal-title":"Flow Meas. Instrum."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/j.sna.2013.03.004","article-title":"Membrane-based thermal flow sensors on flexible substrates","volume":"195","author":"Sturm","year":"2013","journal-title":"Sens. Actuators A Phys."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/j.proeng.2012.09.127","article-title":"Flexible PCB-MEMS flow sensor","volume":"47","author":"Petropoulos","year":"2012","journal-title":"Procedia Eng."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Sturm, H., Brauns, E., Froehner, K., Lang, W., and Buchner, R. (2010, January 1\u20134). Thermoelectric Flow Sensors on Flexible Substrates and Their Integration Proces. Proceedings of the IEEE Sensors, Kona, HI, USA.","DOI":"10.1109\/ICSENS.2010.5690470"},{"key":"ref_23","unstructured":"Bowman, B., and Stasz, P. (1998). Method of Making a Respiration Sensor. (5,832,592), U.S. Patent."},{"key":"ref_24","unstructured":"Zhao, S., and Zhu, R. (2015). Applied Mechanics and Materials, Trans Tech Publication."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Bruun, H.H. (1995). Hot-Wire Anemometry Principles and Signal Analysis. Meas. Sci. Technol., 7.","DOI":"10.1093\/oso\/9780198563426.001.0001"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"11734","DOI":"10.3390\/s120911734","article-title":"Overview and evaluation of bluetooth low energy: An emerging low-power wireless technology","volume":"12","author":"Gomez","year":"2012","journal-title":"Sensors"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Devita, G., Wong, A., Dawkins, M., Glaros, K., Kiani, U., Lauria, F., Madaka, V., Omeni, O., Schiff, J., and Vasudevan, A. (2014, January 22\u201326). A 5 mw Multi-Standard Bluetooth Le\/Ieee 802.15. 6 Soc for Wban Applications. Proceedings of the 40th European Solid State Circuits Conference (ESSCIRC), Venice, Italy.","DOI":"10.1109\/ESSCIRC.2014.6942077"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1186\/1476-069X-8-48","article-title":"Minute ventilation of cyclists, car and bus passengers: An experimental study","volume":"8","author":"Zuurbier","year":"2009","journal-title":"Environ. Health"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Harrison, K.L., and Bogard, D.G. (2008, January 9\u201313). Comparison of Rans Turbulence Models for Prediction of Film Cooling Performance. Proceedings of the ASME Turbo Expo 2008: Power for Land, Sea, and Air, Berlin, Germany.","DOI":"10.1115\/GT2008-51423"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1038\/sj.jhh.1001147","article-title":"Breathing-control lowers blood pressure","volume":"15","author":"Grossman","year":"2001","journal-title":"J. Hum. Hypertens."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"531","DOI":"10.5664\/JCSM.1328","article-title":"Obstructive sleep apnea devices for out-of-center (ooc) testing: Technology evaluation","volume":"7","author":"Collop","year":"2011","journal-title":"J. Clin. Sleep Med. JCSM"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1007\/s11325-011-0547-4","article-title":"Influence of the right-versus left-sided sleeping position on the apnea-hypopnea index in patients with sleep apnea","volume":"16","author":"Ozeke","year":"2012","journal-title":"Sleep Breath."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"634","DOI":"10.3390\/s140100634","article-title":"Technological solutions and main indices for the assessment of newborns' Nutritive Sucking: A review","volume":"14","author":"Tamilia","year":"2014","journal-title":"Sensors"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/15\/12\/29881\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:54:07Z","timestamp":1760216047000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/15\/12\/29881"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,12,15]]},"references-count":33,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2015,12]]}},"alternative-id":["s151229881"],"URL":"https:\/\/doi.org\/10.3390\/s151229881","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,12,15]]}}}