{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,15]],"date-time":"2026-08-15T17:23:40Z","timestamp":1786814620858,"version":"build-2736575974"},"reference-count":28,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2015,12,24]],"date-time":"2015-12-24T00:00:00Z","timestamp":1450915200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001807","name":"Funda\u00e7\u00e3o de Amparo \u00e0 Pesquisa do Estado de S\u00e3o Paulo","doi-asserted-by":"publisher","award":["2014\/08797-8"],"award-info":[{"award-number":["2014\/08797-8"]}],"id":[{"id":"10.13039\/501100001807","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This paper presents a theoretical and experimental study on the use of Eddy Current Testing (ECT) to evaluate corrosion processes in steel bars used in reinforced concrete structures. The paper presents the mathematical basis of the ECT sensor built by the authors; followed by a finite element analysis. The results obtained in the simulations are compared with those obtained in experimental tests performed by the authors. Effective resistances and inductances; voltage drops and phase angles of wound coil are calculated using both; simulated and experimental data; and demonstrate a strong correlation. The production of samples of corroded steel bars; by using an impressed current technique is also presented. The authors performed experimental tests in the laboratory using handmade sensors; and the corroded samples. In the tests four gauges; with five levels of loss-of-mass references for each one were used. The results are analyzed in the light of the loss-of-mass and show a strong linear behavior for the analyzed parameters. The conclusions emphasize the feasibility of the proposed technique and highlight opportunities for future works.<\/jats:p>","DOI":"10.3390\/s16010015","type":"journal-article","created":{"date-parts":[[2015,12,24]],"date-time":"2015-12-24T10:03:53Z","timestamp":1450951433000},"page":"15","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":38,"title":["Corrosion Assessment of Steel Bars Used in Reinforced Concrete Structures by Means of Eddy Current Testing"],"prefix":"10.3390","volume":"16","author":[{"suffix":"Jr.","given":"Naasson","family":"De Alcantara","sequence":"first","affiliation":[{"name":"Department of Electrical Engineering, S\u00e3o Paulo State University\u2014Unesp, Bauru 17033-360, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felipe","family":"Da Silva","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, S\u00e3o Paulo State University\u2014Unesp, Bauru 17033-360, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mateus","family":"Guimar\u00e3es","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, S\u00e3o Paulo State University\u2014Unesp, Bauru 17033-360, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matheus","family":"Pereira","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, S\u00e3o Paulo State University\u2014Unesp, Bauru 17033-360, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2015,12,24]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1061\/(ASCE)0899-1561(2003)15:1(41)","article-title":"Effectiveness of impressed current techniques to simulate corrosion of steel reinforcement in concrete","volume":"15","author":"Soudky","year":"2003","journal-title":"J. Mater. Civil Eng."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"343","DOI":"10.3151\/jact.5.343","article-title":"Simulation of Steel Corrosion in Concrete Based on the Model of Macro-Cell Corrosion Circuit","volume":"6","author":"Maruya","year":"2007","journal-title":"J. Adv. Concrete Technol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1090","DOI":"10.1109\/TIM.2011.2174106","article-title":"Analysis of the Electromagnetic Signature of Reinforced Concrete Structures for Nondestructive Evaluation of Corrosion Damage","volume":"61","author":"Roqueta","year":"2012","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_4","unstructured":"Arndt, R., and Jalinoos, F. (July, January 30). NDE for corrosion dectection in reinforced concrete structures\u2014A benchmark approach. Proceedings of Non-Destructive Testing in Civil Engineering (NDTCE\u201909), Nantes, France."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1016\/j.cemconres.2003.09.024","article-title":"Determination of Chloride Diffusion Coefficient of Concrete Using Open-Circuit Potential Measurements","volume":"34","author":"Erdogdu","year":"2004","journal-title":"Cem. Concr. Res."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S1452-3981(23)17049-0","article-title":"Corrosion Monitoring of Reinforced Concrete Structures\u2014A Review","volume":"2","author":"Song","year":"2007","journal-title":"Int. J. Electrochem. Sci."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1007\/BF02483292","article-title":"Test Methods for on Site Corrosion Rate Measurement of Steel Reinforcement in Concrete by Means of the Polarization Resistance Method","volume":"37","author":"Andrade","year":"2004","journal-title":"Mater. Struct."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1016\/j.cemconcomp.2006.03.005","article-title":"Corrosion Monitoring of Steel in Concrete by Galvanostatic Pulse Technique","volume":"28","author":"Sathiyanarayanan","year":"2006","journal-title":"Cem. Conc. Compos."},{"key":"ref_9","unstructured":"MacDonald, D.D., El-Tantawy, Y.A., and Rocha-Filho, R.C. Evaluation of Electrochemical Impedance Techniques for Detecting Corrosion on Rebar in Reinforced Concrete. Available online: http:\/\/onlinepubs.trb.org\/onlinepubs\/shrp\/SHRP-91-524.pdf."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2777","DOI":"10.1016\/j.corsci.2009.07.014","article-title":"Application of harmonic analysis in measuring the corrosion rate of rebar in concrete","volume":"51","author":"Vedalakshmi","year":"2009","journal-title":"Corros. Sci."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1763","DOI":"10.1016\/S0013-4686(99)00406-5","article-title":"Spectral analysis of electrochemical noise with different transient shapes","volume":"45","author":"Sheng","year":"2000","journal-title":"Electrochimica Acta"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/S0963-8695(00)00051-7","article-title":"Magnetic Field Techniques for the Inspection of Steel Under the Concrete Cover","volume":"34","author":"Makar","year":"2001","journal-title":"NDT&E Int."},{"key":"ref_13","unstructured":"Wolf, T., and Vogel, T. (2012, January 3\u20135). Detection of Reinforcement Breaks: Laboratory Experiments and an Application of the Magnetic Flux Leakage Method. Proceedings of the 14th International Conference and Exhibition on Structural Faults and Repair, Edinburgh, UK."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Shull, P.J. (2002). Nondestructive Evaluation: Theory, Techniques and Applications, CRC Press.","DOI":"10.1201\/9780203911068"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2525","DOI":"10.3390\/s110302525","article-title":"Non-Destructive Techniques Based on Eddy Current Testing","volume":"11","year":"2011","journal-title":"Sensors"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"333","DOI":"10.3233\/JAE-2007-841","article-title":"Concrete Rebar Inspection by Eddy Current Testing","volume":"25","author":"Rubinacci","year":"2007","journal-title":"Int. J. Appl. Electromagn. Mech."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1080\/10589759.2012.695783","article-title":"Identification of Steel Bars Immersed in Reinforced Concrete Based on Experimental Results of Eddy Current Testing and Artificial Neural Network Analysis","volume":"28","author":"Alcantara","year":"2013","journal-title":"Nondest. Test. Eval."},{"key":"ref_18","unstructured":"Annan, A.P. (2009). Ground Penetrating Radar: Theory and Applications, Elsevier."},{"key":"ref_19","unstructured":"Blindow, N., Eisenburger, D., Illich, B., Petzold, H., and Richter, T. (2007). Environmental Geology, Springer."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1016\/j.ndteint.2007.11.001","article-title":"Analysis of Thin-Wire Ground Penetrating Radar Systems for Buried Target Detection, Using a Hybrid MoM-FDTD, Technique","volume":"41","author":"Farnoosh","year":"2008","journal-title":"NDT&E Int."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.ndteint.2004.06.011","article-title":"Location of Steel Reinforcement in Concrete Using Ground Penetrating Radar and Neural Networks","volume":"38","author":"Shaw","year":"2005","journal-title":"NDT&E Int."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1617\/s11527-007-9282-5","article-title":"Detection of chlorides and moisture in concrete structures with ground penetrating radar","volume":"41","author":"Hugenschmidt","year":"2007","journal-title":"Mater. Struct."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/S0963-8695(98)00012-7","article-title":"Imaging of Concrete Structures","volume":"31","author":"Buyukozturk","year":"1998","journal-title":"NDT&E Int."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1007\/s10921-012-0133-0","article-title":"Nondestructive corrosion detection in RC through integrated heat Induction and IR thermography","volume":"31","author":"Baek","year":"2012","journal-title":"J. Nondest. Eval."},{"key":"ref_25","unstructured":"FEMM\u2014Finite Element Method Magnetics. Available online: http:\/\/www.femm.info\/."},{"key":"ref_26","unstructured":"COMSOL Multiphysics. Available online: http:\/\/comsol.com."},{"key":"ref_27","first-page":"95","article-title":"Techniques for Inducing Accelerated Corrosion of Steel in Concrete","volume":"34","author":"Ahmad","year":"2009","journal-title":"Arab. J. Sci. Eng."},{"key":"ref_28","first-page":"154","article-title":"Performance Evaluation of Rebar in Accelerated Corrosion by Gravimetric Loss Method","volume":"5","author":"Shetty","year":"2012","journal-title":"Int. J. Earth Sci. Eng."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/1\/15\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:54:44Z","timestamp":1760216084000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/1\/15"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,12,24]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2016,1]]}},"alternative-id":["s16010015"],"URL":"https:\/\/doi.org\/10.3390\/s16010015","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,12,24]]}}}