{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T19:09:57Z","timestamp":1790795397940,"version":"4.1.0"},"reference-count":38,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2016,1,15]],"date-time":"2016-01-15T00:00:00Z","timestamp":1452816000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Insulin is a key regulator in glucose homeostasis and its deficiency or alternations in the human body causes various types of diabetic disorders. In this paper, we present the development of a reduced graphene oxide (rGO) modified interdigitated chain electrode (ICE) for direct capacitive detection of insulin. The impedance properties of rGO-ICE were characterized by equivalent circuit modeling. After an electrochemical deposition of rGO on ICE, the electrode was modified with self-assembled monolayers and insulin antibodies in order to achieve insulin binding reactions. The impedance spectra and capacitances were measured with respect to the concentrations of insulin and the capacitance change (\u0394C) was analyzed to quantify insulin concentration. The antibody immobilized electrode showed an increment of \u0394C according to the insulin concentration in human serum ranging from 1 ng\/mL to 10 \u00b5g\/mL. The proposed sensor is feasible for label-free and real-time measuring of the biomarker and for point-of-care diagnosis.<\/jats:p>","DOI":"10.3390\/s16010109","type":"journal-article","created":{"date-parts":[[2016,1,16]],"date-time":"2016-01-16T03:30:25Z","timestamp":1452915025000},"page":"109","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":32,"title":["Reduced Graphene Oxide Modified the Interdigitated Chain Electrode for an Insulin Sensor"],"prefix":"10.3390","volume":"16","author":[{"given":"Ajay","family":"Yagati","sequence":"first","affiliation":[{"name":"Department of Biomedical Engineering, Gachon University, 191 Hambakmoe-ro, Yeonsu-gu, Incheon 21936, Korea"},{"name":"Gachon Advanced Institute for Health Science &amp; Technology, Gachon University, 155 Get-Pearl-ro, Yeonsu-gu, Incheon 21999, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinsoo","family":"Park","sequence":"additional","affiliation":[{"name":"Gachon Advanced Institute for Health Science &amp; Technology, Gachon University, 155 Get-Pearl-ro, Yeonsu-gu, Incheon 21999, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3839-6410","authenticated-orcid":false,"given":"Sungbo","family":"Cho","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Gachon University, 191 Hambakmoe-ro, Yeonsu-gu, Incheon 21936, Korea"},{"name":"Gachon Advanced Institute for Health Science &amp; Technology, Gachon University, 155 Get-Pearl-ro, Yeonsu-gu, Incheon 21999, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2016,1,15]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.jasms.2008.10.003","article-title":"Mapping disulfide bonds in insulin with the route 66 method: Selective cleavage of S-C bonds using alkali and alkaline earth metal enolate complexes","volume":"20","author":"Kim","year":"2009","journal-title":"J. Am. Soc. Mass. Spectr."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1254\/jphs.FMJ04006X4","article-title":"Malfunction of vascular control in lifestyle-related diseases: Mechanisms underlying endothelial dysfunction in the insulin-resistant state","volume":"96","author":"Shinozaki","year":"2004","journal-title":"J. Pharmacol. Sci."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Chen, H.H., Yeh, C.J., Lin, C.L., Yeh, S.Y., and Kao, C.H. (2015). Statins can delay insulin use and reduce diabetes-related diseases in asian patients with type 2 diabetes. Medicine, 94.","DOI":"10.1097\/MD.0000000000000735"},{"key":"ref_4","unstructured":"World Health Organization (1999). Definition, Diagnosis and Classification of Diabetes Mellitus and Its Complications. Part 1: Diagnosis and Classification of Diabetes Mellitu, World Health Organization. (WHO\/NCD\/NCS\/99.2)."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1016\/j.bios.2012.10.046","article-title":"Development of an electrochemical insulin sensor based on the insulin-linked polymorphic region","volume":"42","author":"Gerasimov","year":"2013","journal-title":"Biosens. Bioelectron."},{"key":"ref_6","first-page":"1167","article-title":"Detection of insulin-antibodies by radioassay and elisa\u2014Interrelation and correlation with metabolic control in type-I diabetes","volume":"27","author":"Dib","year":"1994","journal-title":"Braz. J. Med. Biol. Res."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1111\/evj.12486_4","article-title":"Evaluation of several screening tests for determination of the igG concentration of foals with the turbidimetric immunoassay as reference method","volume":"47","author":"Zandstra","year":"2015","journal-title":"Equine Vet. J."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1349","DOI":"10.1373\/clinchem.2012.199794","article-title":"Quantitative insulin analysis using liquid chromatography-tandem mass spectrometry in a high-throughput clinical laboratory","volume":"59","author":"Chen","year":"2013","journal-title":"Clin. Chem."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/S0925-4005(01)00819-X","article-title":"Penicillin detection by means of field-effect based sensors: Enfet, capacitive eis sensor or laps?","volume":"78","author":"Poghossian","year":"2001","journal-title":"Sens. Actuators B Chem."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/S0925-4005(98)00027-6","article-title":"A novel silicon-based sensor array with capacitive eis structures","volume":"47","author":"Schoning","year":"1998","journal-title":"Sens. Actuators B Chem."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1239","DOI":"10.1002\/elan.200603855","article-title":"Label-free impedance biosensors: Opportunities and challenges","volume":"19","author":"Daniels","year":"2007","journal-title":"Electroanalysis"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/0003-2670(94)00418-L","article-title":"Application of redox cycling enhanced current at an interdigitated array electrode for iron-trace determination in ultrapure spectral carbon","volume":"305","author":"Bustin","year":"1995","journal-title":"Anal. Chim. Acta"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"4690","DOI":"10.1016\/j.bios.2011.05.027","article-title":"Electrical immunosensor based on a submicron-gap interdigitated electrode and gold enhancement","volume":"26","author":"Ahn","year":"2011","journal-title":"Biosens. Bioelectron."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"6404","DOI":"10.1039\/c3an00905j","article-title":"The effect of channel height and electrode aspect ratio on redox cycling at carbon interdigitated array nanoelectrodes confined in a microchannel","volume":"138","author":"Heo","year":"2013","journal-title":"Analyst"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.aca.2014.07.006","article-title":"A capacitive biosensor based on an interdigitated electrode with nanoislands","volume":"844","author":"Jung","year":"2014","journal-title":"Anal. Chim. Acta"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"22192","DOI":"10.3390\/s150922192","article-title":"Simulations of interdigitated electrode interactions with gold nanoparticles for impedance-based biosensing applications","volume":"15","author":"MacKay","year":"2015","journal-title":"Sensors"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"580","DOI":"10.3390\/s5120580","article-title":"Improvement of amperometric sensor used for determination of nitrate with polypyrrole nanowires modified electrode","volume":"5","author":"Zhang","year":"2005","journal-title":"Sensors"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"15227","DOI":"10.3390\/s140815227","article-title":"Simultaneous electrochemical detection of dopamine and ascorbic acid using an iron oxide\/reduced graphene oxide modified glassy carbon electrode","volume":"14","author":"Pandikumar","year":"2014","journal-title":"Sensors"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1016\/j.bios.2012.07.052","article-title":"Electrochemical impedance spectroscopy biosensor with interdigitated electrode for detection of human immunoglobulin A","volume":"40","author":"Ohno","year":"2013","journal-title":"Biosens. Bioelectron."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.jelechem.2014.10.020","article-title":"Electrochemical deposition of gold nanoparticles on reduced graphene oxide modified glassy carbon electrode for simultaneous determination of levodopa, uric acid and folic acid","volume":"736","author":"Benvidi","year":"2015","journal-title":"J. Electroanal. Chem."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"G133","DOI":"10.1149\/2.1001414jes","article-title":"Electrosynthesis of ergo-np nanocomposite films for bioelectrocatalysis of horseradish peroxidase towards H2O2","volume":"161","author":"Yagati","year":"2014","journal-title":"J. Electrochem. Soc."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"5087","DOI":"10.1016\/j.polymer.2013.06.027","article-title":"A review on synthesis and properties of polymer functionalized graphene","volume":"54","author":"Layek","year":"2013","journal-title":"Polymer"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2474","DOI":"10.1002\/elan.201400196","article-title":"Development of an electrochemical sensor based on reduced graphene oxide modified screen-printed carbon electrode for the determination of buprenorphine","volume":"26","author":"Fakhari","year":"2014","journal-title":"Electroanalysis"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"16614","DOI":"10.3390\/s150716614","article-title":"Electrochemical co-reduction synthesis of aupt bimetallic nanoparticles-graphene nanocomposites for selective detection of dopamine in the presence of ascorbic acid and uric acid","volume":"15","author":"Zhao","year":"2015","journal-title":"Sensors"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1002\/1521-4109(200103)13:3<173::AID-ELAN173>3.0.CO;2-B","article-title":"Capacitive biosensors","volume":"13","author":"Berggren","year":"2001","journal-title":"Electroanalysis"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1016\/j.snb.2013.09.019","article-title":"Epitaxial graphene immunosensor for human chorionic gonadotropin","volume":"190","author":"Teixeira","year":"2014","journal-title":"Sens. Actuators B Chem."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"9990","DOI":"10.1039\/c3ra47732k","article-title":"Immobilization of transition metal (Fe2+, Co2+, Vo2+ or Cu2+) schiff base complexes onto graphene oxide as efficient and recyclable catalysts for epoxidation of styrene","volume":"4","author":"Su","year":"2014","journal-title":"RSC Adv."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"7207","DOI":"10.1039\/c1sm05086a","article-title":"Site-directed immobilization of antibodies onto blood contacting grafts for enhanced endothelial cell adhesion and proliferation","volume":"7","author":"Yuan","year":"2011","journal-title":"Soft Matter."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"C452","DOI":"10.1149\/1.3499564","article-title":"Constant-phase-element behavior caused by resistivity distributions in films I. Theory.","volume":"157","author":"Hirschorn","year":"2010","journal-title":"J. Electrochem. Soc."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1382","DOI":"10.1016\/j.bios.2006.06.012","article-title":"Self-assembled PEG monolayer based SPR immunosensor for label-free detection of insulin","volume":"22","author":"Gobi","year":"2007","journal-title":"Biosens. Bioelectron."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/j.jelechem.2013.12.015","article-title":"Electrocatalytic determination of traces of insulin using a novel silica nanoparticles-nafion modified glassy carbon electrode","volume":"714","author":"Amini","year":"2014","journal-title":"J. Electroanal. Chem."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1016\/j.bios.2015.09.036","article-title":"Nickel nanoparticle-modified electrode for ultra-sensitive electrochemical detection of insulin","volume":"77","author":"Yu","year":"2016","journal-title":"Biosens. Bioelectron."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"41317","DOI":"10.1039\/C5RA03306C","article-title":"Ethylenediamine-assisted preparation of carbon nanofiber supported nickel oxide electrocatalysts for sensitive and durable detection of insulin","volume":"5","author":"Zhang","year":"2015","journal-title":"RSC Adv."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.bios.2013.01.037","article-title":"Electrocatalytic oxidation and determination of insulin at nickel oxide nanoparticles-multiwalled carbon nanotube modified screen printed electrode","volume":"46","author":"Rafiee","year":"2013","journal-title":"Biosens. Bioelectron."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"756","DOI":"10.1016\/j.snb.2010.08.004","article-title":"Electrocatalytic oxidation and determination of insulin at CNT-nickel-cobalt oxide modified electrode","volume":"150","author":"Arvinte","year":"2010","journal-title":"Sens. Actuators B Chem."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.aca.2009.02.029","article-title":"A carbon nanotubes assisted strategy for insulin detection and insulin proteolysis assay","volume":"650","author":"Wang","year":"2009","journal-title":"Anal. Chim. Acta"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1016\/j.bios.2008.06.046","article-title":"Highly sensitive sensor for picomolar detection of insulin at physiological ph, using gc electrode modified with guanine and electrodeposited nickel oxide nanoparticles","volume":"24","author":"Salimi","year":"2008","journal-title":"Biosens. Bioelectron."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"46208","DOI":"10.1039\/C4RA06648K","article-title":"Facile synthesis of nickel hydroxide-graphene nanocomposites for insulin detection with enhanced electro-oxidation properties","volume":"4","author":"Lin","year":"2014","journal-title":"RSC Adv."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/1\/109\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:17:47Z","timestamp":1760210267000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/1\/109"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,1,15]]},"references-count":38,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2016,1]]}},"alternative-id":["s16010109"],"URL":"https:\/\/doi.org\/10.3390\/s16010109","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,1,15]]}}}