{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T05:05:39Z","timestamp":1787029539399,"version":"build-2736575974"},"reference-count":24,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2016,1,25]],"date-time":"2016-01-25T00:00:00Z","timestamp":1453680000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A well-defined condition-monitoring for power transformers is key to implementing a correct condition-based maintenance (CBM). In this regard, partial discharges (PD) measurement and its analysis allows to carry out on-line maintenance following the standards IEC-60270 and IEC-60076. However, new PD measurements techniques, such as acoustics or electromagnetic (EM) acquisitions using ultra-high-frequency (UHF) sensors are being taken into account, IEC-62478. PD measurements with antennas and the effect of their EM propagation in power transformer tanks is an open research topic that is considered in this paper. In this sense, an empty tank model is studied as a rectangular cavity and their resonances are calculated and compared with their measurement with a network analyser. Besides, two low cost improved monopole antennas deployed inside and outside of the tank model capture background noise and PD pulses in three different test objects (Nomex, twisted pair and insulator). The average spectrum of them are compared and can be found that mainly, the antenna frequency response, the frequency content distribution depending on the PD source and the enclosure resonances modes are the main factors to be considered in PD acquisitions with these sensors. Finally, with this set-up, it is possible to measure PD activity inside the tank from outside.<\/jats:p>","DOI":"10.3390\/s16020148","type":"journal-article","created":{"date-parts":[[2016,1,25]],"date-time":"2016-01-25T10:03:06Z","timestamp":1453716186000},"page":"148","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":48,"title":["On the Use of Monopole Antennas for Determining the Effect of the Enclosure of a Power Transformer Tank in Partial Discharges Electromagnetic Propagation"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1586-5931","authenticated-orcid":false,"given":"Ricardo","family":"Albarrac\u00edn","sequence":"first","affiliation":[{"name":"Generation and Distribution Network Area. Department of Electrical Engineering. Leader in Innovation, Technology and R&amp;D, Boslan Engineering and Consulting S.A., Madrid 28034, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8811-2274","authenticated-orcid":false,"given":"Jorge","family":"Ardila-Rey","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Universidad T\u00e9cnica Federico Santa Mar\u00eda, Santiago de Chile 8940000, Chile"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3262-0111","authenticated-orcid":false,"given":"Abdullahi","family":"Mas\u2019ud","sequence":"additional","affiliation":[{"name":"Department of Electrical and Electronic Engineering Technology, Jubail Industrial College, Road No. 6, 8244 Al Huwailat, Al Jubail 35718, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2016,1,25]]},"reference":[{"key":"ref_1","first-page":"5","article-title":"Partial discharge monitoring of power transformers using UHF sensors. Part I: sensors and signal interpretation","volume":"21","author":"Judd","year":"2005","journal-title":"IEEE Electri. Insul. Mag."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1576","DOI":"10.1109\/TDEI.2008.4712660","article-title":"Detection and location of partial discharges in power transformers using acoustic and electromagnetic signals","volume":"15","author":"Markalous","year":"2008","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Chen, Z.N. (2015). Handbook of Antenna Technologies, Springer Singapore.","DOI":"10.1007\/978-981-4560-75-7"},{"key":"ref_4","unstructured":"IEC-62478 (2016). High-Voltage Test Techniques\u2014Measurement of Partial Discharges by Electromagnetic and Acoustic Methods. Proposed Horizontal Standard, International Electrotechnical Commission (IEC). [1st ed.]. (submitted)."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1553","DOI":"10.1109\/TDEI.2008.4712657","article-title":"Sensitivity of UHF PD measurements in power transformers","volume":"15","author":"Coenen","year":"2008","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"9882","DOI":"10.3390\/s150509882","article-title":"Separation of Radio-Frequency Sources and Localization of Partial Discharges in Noisy Environments","volume":"15","author":"Robles","year":"2015","journal-title":"Sensors"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/j.isatra.2015.04.006","article-title":"Separation of sources in radiofrequency measurements of partial discharges using time-power ratio maps","volume":"58","author":"Robles","year":"2015","journal-title":"ISA Trans."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1109\/TDEI.2013.6508772","article-title":"Shielding effect of power transformers tanks in the ultra-high-frequency detection of partial discharges","volume":"20","author":"Robles","year":"2013","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Mirzaei, H., Akbari, A., Zanjani, M., Gockenbach, E., and Borsi, H. (2012, January 23\u201327). Investigating the partial discharge electromagnetic wave propagation in power transformers considering active part characteristics. Proceedings of the IEEE 2012 International Conference on Condition Monitoring and Diagnosis (CMD), Bali, India.","DOI":"10.1109\/CMD.2012.6416173"},{"key":"ref_10","unstructured":"Balanis, C.A. (2012). Advanced Engineering Electromagnetics, Wiley. [2nd ed.]."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1109\/TIM.2012.2223332","article-title":"Antenna Parametrization for the Detection of Partial Discharges","volume":"62","author":"Robles","year":"2013","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_12","unstructured":"Balanis, C.A. (2005). Antenna Theory: Analysis and Design, Wiley-Interscience. [3rd ed.]."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1049\/ip-smt:19951699","article-title":"Broadband couplers for UHF detection of partial discharge in gas-insulated substations","volume":"142","author":"Judd","year":"1995","journal-title":"IEE Proc. Sci. Meas. Technol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.1109\/TDEI.2006.258190","article-title":"Partial discharge location in power transformers using wideband RF detection","volume":"13","author":"Tang","year":"2006","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1634","DOI":"10.1109\/TDEI.2008.4712667","article-title":"Optimisation of a sensor for onsite detection of partial discharges in power transformers by the UHF method","volume":"15","author":"Tang","year":"2008","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1462","DOI":"10.1109\/TDEI.2009.5293961","article-title":"Detecting characteristics of various type antennas on partial discharge electromagnetic wave radiating through insulating spacer in gas insulated switchgear","volume":"16","author":"Kaneko","year":"2009","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2546","DOI":"10.1109\/TPEL.2008.2002069","article-title":"A UHF Technique for Advanced PD Measurements on Inverter-Fed Motors","volume":"23","author":"Fabiani","year":"2008","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Stutzman, W.L., and Thiele, G. (1998). Antenna Theory and Design, Wiley.","DOI":"10.1002\/047134608X.W1206"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1109\/MEI.2006.1618969","article-title":"Cellulose insulation in oil-filled power transformers: Part I\u2014History and development","volume":"22","author":"Prevost","year":"2006","journal-title":"IEEE Electr. Insul. Mag."},{"key":"ref_20","unstructured":"Cheng, D.K. (1998). Fundamentals of Electromagnetism Engineering, Addison Wesley Iberoamericana."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1483","DOI":"10.1016\/j.ymssp.2005.09.012","article-title":"A review on machinery diagnostics and prognostics implementing condition-based maintenance","volume":"20","author":"Jardine","year":"2006","journal-title":"Mech. Syst. Signal Process."},{"key":"ref_22","unstructured":"Gill, P. (2008). Electrical Power Equipment Maintenance and Testing, Second Edition, Power Engineering (Willis), Taylor & Francis."},{"key":"ref_23","unstructured":"IEC-60270 (2000). High-Voltage Test Techniques\u2014Partial Discharge Measurements, International Electrotechnical Commission (IEC). [3rd ed.]."},{"key":"ref_24","unstructured":"Pozar, D. (2005). Microwave Engineering, Wiley."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/2\/148\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:18:13Z","timestamp":1760210293000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/2\/148"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,1,25]]},"references-count":24,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2016,2]]}},"alternative-id":["s16020148"],"URL":"https:\/\/doi.org\/10.3390\/s16020148","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,1,25]]}}}