{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T03:33:44Z","timestamp":1794972824188,"version":"4.9.1"},"reference-count":28,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2016,1,27]],"date-time":"2016-01-27T00:00:00Z","timestamp":1453852800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This paper presents a full parallel event driven readout method which is implemented in an area array single-photon avalanche diode (SPAD) image sensor for high-speed fluorescence lifetime imaging microscopy (FLIM). The sensor only records and reads out effective time and position information by adopting full parallel event driven readout method, aiming at reducing the amount of data. The image sensor includes four 8 \u00d7 8 pixel arrays. In each array, four time-to-digital converters (TDCs) are used to quantize the time of photons\u2019 arrival, and two address record modules are used to record the column and row information. In this work, Monte Carlo simulations were performed in Matlab in terms of the pile-up effect induced by the readout method. The sensor\u2019s resolution is 16 \u00d7 16. The time resolution of TDCs is 97.6 ps and the quantization range is 100 ns. The readout frame rate is 10 Mfps, and the maximum imaging frame rate is 100 fps. The chip\u2019s output bandwidth is 720 MHz with an average power of 15 mW. The lifetime resolvability range is 5\u201320 ns, and the average error of estimated fluorescence lifetimes is below 1% by employing CMM to estimate lifetimes.<\/jats:p>","DOI":"10.3390\/s16020160","type":"journal-article","created":{"date-parts":[[2016,1,28]],"date-time":"2016-01-28T02:19:45Z","timestamp":1453947585000},"page":"160","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["A Full Parallel Event Driven Readout Technique for Area Array SPAD FLIM Image Sensors"],"prefix":"10.3390","volume":"16","author":[{"given":"Kaiming","family":"Nie","sequence":"first","affiliation":[{"name":"School of Electronic Information Engineering, Tianjin University, 92 Weijin Road, Nankai District, Tianjin 300072, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinlei","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Electronic Information Engineering, Tianjin University, 92 Weijin Road, Nankai District, Tianjin 300072, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Qiao","sequence":"additional","affiliation":[{"name":"School of Electronic Information Engineering, Tianjin University, 92 Weijin Road, Nankai District, Tianjin 300072, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiangtao","family":"Xu","sequence":"additional","affiliation":[{"name":"School of Electronic Information Engineering, Tianjin University, 92 Weijin Road, Nankai District, Tianjin 300072, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2016,1,27]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2995","DOI":"10.1364\/AO.42.002995","article-title":"Studying biological tissue with fluorescence lifetime imaging: Microscopy, endoscopy, and complex decay profiles","volume":"42","author":"Siegel","year":"2003","journal-title":"Appl. Opt."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1724","DOI":"10.1364\/BOE.4.001724","article-title":"Multimodal in vivo imaging of oral cancer using fluorescence lifetime, photoacoustic and ultrasound techniques","volume":"4","author":"Fatakdawala","year":"2013","journal-title":"Biomed. Opt. Express."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"R61","DOI":"10.1088\/0022-3727\/35\/9\/201","article-title":"Time-resolved fluorescence imaging in biology and medicine","volume":"35","author":"Cubeddu","year":"2002","journal-title":"J. Phys. D Appl. Phys."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Pawley, J.B. (1995). Handbook of Biological Confocal Microscopy, Springer.","DOI":"10.1007\/978-1-4757-5348-6"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Mosconi, D., Stoppa, D., Pancheri, L., Gonzo, L., and Simoni, A. (2006, January 19\u201321). CMOS Single Photon Avalanche Diode Array for Time-Resolved Fluorescence Detection. Proceedings of the 32nd European Solid-State Circuits Conference (ESSCIRC), Montreaux, Switzerland.","DOI":"10.1109\/ESSCIR.2006.307487"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"10257","DOI":"10.1364\/OE.18.010257","article-title":"Real-time fluorescence lifetime imaging system with a 32 \u00d7 32 0.13 \u03bcm CMOS low dark-count single-photon avalanche diode array","volume":"18","author":"Li","year":"2010","journal-title":"Opt. Express."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1939","DOI":"10.1109\/TED.2015.2421500","article-title":"Single photon avalanche diode collection efficiency enhancement via peripheral well controlled field","volume":"62","author":"Savuskan","year":"2015","journal-title":"IEEE Trans. Electron Dev."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1956","DOI":"10.1364\/AO.35.001956","article-title":"Avalanche photodiodes and quenching circuits for single-photon detection","volume":"35","author":"Cova","year":"1996","journal-title":"Appl. Opt."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2028","DOI":"10.1109\/TED.2011.2141138","article-title":"Scaleable Single-Photon Avalanche Diode Structures in Nanometer CMOS Technology","volume":"58","author":"Richardson","year":"2011","journal-title":"IEEE Trans. Electron Dev."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1109\/JSTQE.2014.2344034","article-title":"CMOS SPADs: Design Issues and Research Challenges for Detectors, Circuits, and Arrays","volume":"20","author":"Palubiak","year":"2014","journal-title":"IEEE J. Sel. Top. Quantum Electron."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.1109\/JSEN.2009.2025581","article-title":"Single-Photon Avalanche Diode CMOS Sensor for Time-Resolved Fluorescence Measurements","volume":"9","author":"Stoppa","year":"2009","journal-title":"IEEE Sens. J."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"5650","DOI":"10.3390\/s120505650","article-title":"Time-Domain Fluorescence Lifetime Imaging Techniques Suitable for Solid-State Imaging Sensor Arrays","volume":"12","author":"Li","year":"2012","journal-title":"Sensors"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/JSTQE.2014.2333238","article-title":"A Single-Photon Avalanche Camera for Fluorescence Lifetime Imaging Microscopy and Correlation Spectroscopy","volume":"20","author":"Vitali","year":"2014","journal-title":"IEEE J. Sel. Top. Quantum Electron."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Veerappan, C., Richardson, J., Walker, R., Li, D.D.U., Fishburn, M.W., Maruyama, Y., Stoppa, D., Borghetti, F., Gersbach, M., and Henderson, R.K. (2011, January 20\u201324). A 160 \u00d7 128 single-photon image sensor with on-pixel 55 ps 10 b time-to-digital converter. Proceedings of the IEEE International Solid-state Circuits Conference (ISSCC), San Francisco, CA, USA.","DOI":"10.1109\/ISSCC.2011.5746333"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2546","DOI":"10.1109\/JSSC.2008.2005818","article-title":"A Single-Photon Avalanche Diode Array for Fluorescence Lifetime Imaging Microscopy","volume":"43","author":"Schwartz","year":"2008","journal-title":"IEEE J. Solid State Circuits"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Stoppa, D., Borghetti, F., Richardson, J., Walker, R., Grant, L., Henderson, R.K., Gersbach, M., and Charbon, E. (2009, January 14\u201318). A 32 \u00d7 32-pixel array with in-pixel photon counting and arrival time measurement in the analog domain. Proceedings of the European Solid-state Circuits Conference (ESSCIRC), Athens, Greece.","DOI":"10.1109\/ESSCIRC.2009.5325970"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2977","DOI":"10.1109\/JSSC.2008.2006445","article-title":"A 128 \u00d7 128 single-photon image sensor with column-level 10-bit timeto-digital converter array","volume":"43","author":"Niclass","year":"2008","journal-title":"IEEE J. Solid State Circuits"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1394","DOI":"10.1109\/JSSC.2012.2188466","article-title":"A Time-Resolved, Low-Noise Single-Photon Image Sensor Fabricated in Deep-Submicron CMOS Technology","volume":"47","author":"Gersbach","year":"2012","journal-title":"IEEE J. Solid State Circuits"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1109\/JSSC.2013.2293777","article-title":"A 100 fps, Time-Correlated Single-Photon-Counting-Based Fluorescence-Lifetime Imager in 130 nm CMOS","volume":"49","author":"Field","year":"2014","journal-title":"IEEE J. Solid State Circuits"},{"key":"ref_20","unstructured":"Homulle, H. (2014). Development of a Multichannel TCSPC System in a Spartan 6 FPGA. [Ph.D. Thesis, Technical University of Delft]."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Dutton, N.A.W., Gnecchi, S., Parmrsan, L., Holmes, A.J., Rae, B., Grant, L.A., and Henderson, R.K. (2015, January 22\u201326). A Time-Correlated Single-Photon Counting Sensor with 14 GS\/s Histogramming Time-to-Digital Converter. Proceedings of the IEEE International Solid-state Circuits Conference (ISSCC), San Francisco, CA, USA.","DOI":"10.1109\/ISSCC.2015.7062997"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1109\/LPT.2015.2416192","article-title":"High fill-factor 60 \u00d7 1 SPAD array with 60 sub-nanosecond integrated TDCs","volume":"27","author":"Villa","year":"2015","journal-title":"IEEE Photonic Tech. Lett."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1705","DOI":"10.1364\/AO.48.001705","article-title":"Active quenching circuit for single-photon detection with Geiger mode avalanche photodiodes","volume":"48","year":"2009","journal-title":"Appl. Opt."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1109\/TBCAS.2012.2222639","article-title":"A High-Throughput Time-Resolved Mini-Silicon Photomultiplier With Embedded Fluorescence Lifetime Estimation in 0.13 \u03bcm CMOS","volume":"6","author":"Tyndall","year":"2012","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1109\/TIM.2007.911691","article-title":"High-Speed and Compact Quenching Circuit for Single-Photon Avalanche Diodes","volume":"57","author":"Mita","year":"2008","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Arlt, J., Tyndall, D., Rae, B.R., Li, D.D.U., Richardson, J.A., and Henderson, R.K. (2013). A study of pile-up in integrated time-correlated single photon counting system. Rev. Sci. Instrum., 84.","DOI":"10.1063\/1.4824196"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2491","DOI":"10.1021\/j150620a019","article-title":"Better Estimates of Exponential Decay Parameters","volume":"85","author":"Hall","year":"1981","journal-title":"J. Phys. Chem."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Li, D.D.U., Arlt, J., Tyndall, D., Walker, R., Richardson, J., Stoppa, D., Charbon, E., and Henderson, R.K. (2011). Video-rate fluorescence lifetime imaging camera with CMOS single-photon avalanche diode arrays and high-speed imaging algorithm. J. Biomed. Opt., 16.","DOI":"10.1117\/1.3625288"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/2\/160\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:18:23Z","timestamp":1760210303000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/2\/160"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,1,27]]},"references-count":28,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2016,2]]}},"alternative-id":["s16020160"],"URL":"https:\/\/doi.org\/10.3390\/s16020160","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,1,27]]}}}