{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T04:01:49Z","timestamp":1792555309963,"version":"4.5.0"},"reference-count":25,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2016,2,4]],"date-time":"2016-02-04T00:00:00Z","timestamp":1454544000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Gait analysis may enhance clinical practice. However, its use is limited due to the need for expensive equipment which is not always available in clinical settings. Recent evidence suggests that Microsoft Kinect may provide a low cost gait analysis method. The purpose of this report is to critically evaluate the literature describing the concurrent validity of using the Kinect as a gait analysis instrument. An online search of PubMed, CINAHL, and ProQuest databases was performed. Included were studies in which walking was assessed with the Kinect and another gold standard device, and consisted of at least one numerical finding of spatiotemporal or kinematic measures. Our search identified 366 papers, from which 12 relevant studies were retrieved. The results demonstrate that the Kinect is valid only for some spatiotemporal gait parameters. Although the kinematic parameters measured by the Kinect followed the trend of the joint trajectories, they showed poor validity and large errors. In conclusion, the Kinect may have the potential to be used as a tool for measuring spatiotemporal aspects of gait, yet standardized methods should be established, and future examinations with both healthy subjects and clinical participants are required in order to integrate the Kinect as a clinical gait analysis tool.<\/jats:p>","DOI":"10.3390\/s16020194","type":"journal-article","created":{"date-parts":[[2016,2,4]],"date-time":"2016-02-04T10:26:22Z","timestamp":1454581582000},"page":"194","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":178,"title":["Validity of the Kinect for Gait Assessment: A Focused Review"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2589-1968","authenticated-orcid":false,"given":"Shmuel","family":"Springer","sequence":"first","affiliation":[{"name":"Department of Physical Therapy, Faculty of Health Sciences ,Ariel University, Kiryat Hamda, Ariel 40700, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Galit","family":"Yogev Seligmann","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Tel-Aviv University, Tel Aviv 69978, Israel"},{"name":"Functional Brain Center, Wohl Institute for Advanced Imaging, Tel-Aviv Sourasky Medical Center, Tel Aviv 69978, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2016,2,4]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1501","DOI":"10.2522\/ptj.20050387","article-title":"Gait characteristics of elderly people with a history of falls: A dynamic approach","volume":"86","author":"Barak","year":"2006","journal-title":"Phys. Ther."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/j.gaitpost.2011.03.027","article-title":"Efficacy of clinical gait analysis: A systematic review","volume":"34","author":"Wren","year":"2011","journal-title":"Gait Posture"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1005","DOI":"10.1016\/j.gaitpost.2014.02.001","article-title":"Summary measures for clinical gait analysis: A literature review","volume":"39","author":"Cimolin","year":"2014","journal-title":"Gait Posture"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1123\/japa.2013-0236","article-title":"Walking speed: The functional vital sign","volume":"23","author":"Middleton","year":"2015","journal-title":"J. Aging Phys. Act."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2722","DOI":"10.1016\/j.jbiomech.2013.08.011","article-title":"Concurrent validity of the Microsoft Kinect for assessment of spatiotemporal gait variables","volume":"46","author":"Clark","year":"2013","journal-title":"J. Biomech."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Gabel, M., Gilad-Bachrach, R., Renshaw, E., and Schuster, A. (September, January 28). Full body gait analysis with Kinect. Proceedings of the 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), San Diego, CA, USA.","DOI":"10.1109\/EMBC.2012.6346340"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1016\/j.gaitpost.2008.09.003","article-title":"The reliability of three-dimensional kinematic gait measurements: A systematic review","volume":"29","author":"McGinley","year":"2009","journal-title":"Gait Posture"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Liberati, A., Altman, D.G., Tetzlaff, J., Mulrow, C., G\u00f8tzsche, P.C., Ioannidis, J.P., Clarke, M., Devereaux, P.J., Kleijnen, J., and Moher, D. (2009). The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: Explanation and elaboration. Ann. Intern. Med., 151.","DOI":"10.1371\/journal.pmed.1000100"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Higgins, J.P., Altman, D.G., G\u00f8tzsche, P.C., J\u00fcni, P., Moher, D., Oxman, A.D., Savovic, J., Schulz, K.F., Weeks, L., and Sterne, J.A. (2011). The Cochrane Collaboration\u2019s tool for assessing risk of bias in randomised trials. BMJ, 343.","DOI":"10.1136\/bmj.d5928"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/j.gaitpost.2006.01.003","article-title":"Gait classification in children with cerebral palsy: A systematic review","volume":"25","author":"Dobson","year":"2007","journal-title":"Gait Posture"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.jclinepi.2006.03.012","article-title":"Quality criteria were proposed for measurement properties of health status questionnaires","volume":"60","author":"Terwee","year":"2007","journal-title":"J. Clin. Epidemiol."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Whiting, P., Rutjes, A.W., Reitsma, J.B., Bossuyt, P.M., and Kleijnen, J. (2003). The development of QUADAS: A tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med. Res. Methodol., 3.","DOI":"10.1186\/1471-2288-3-25"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Behrens, J., Pfuller, C., Mansow-Model, S., Otte, K., Paul, F., and Brandt, A.U. (2014). Using perceptive computing in multiple sclerosis-the Short Maximum Speed Walk test. J. Neuroeng. Rehabil., 11.","DOI":"10.1186\/1743-0003-11-89"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1062","DOI":"10.1016\/j.gaitpost.2014.01.008","article-title":"Accuracy of the Microsoft Kinect sensor for measuring movement in people with Parkinson\u2019s disease","volume":"39","author":"Galna","year":"2014","journal-title":"Gait Posture"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Clark, R.A., Vernon, S., Mentiplay, B.F., Miller, K.J., McGinley, J.L., Pua, Y.H., Paterson, K., and Bower, K.J. (2015). Instrumenting gait assessment using the Kinect in people living with stroke: Reliability and association with balance tests. J. Neuroeng. Rehabil., 12.","DOI":"10.1186\/s12984-015-0006-8"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1177\/1545968314529475","article-title":"Quantifying individual components of the timed up and go using the kinect in people living with stroke","volume":"29","author":"Vernon","year":"2015","journal-title":"Neurorehabil. Neural Repair"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"997","DOI":"10.1109\/TNSRE.2013.2282868","article-title":"Validation of a method for real time foot position and orientation tracking with Microsoft Kinect technology for use in virtual reality and treadmill based gait training programs","volume":"22","author":"Paolini","year":"2014","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"274","DOI":"10.3109\/03091902.2014.909540","article-title":"Comparative abilities of Microsoft Kinect and Vicon 3D motion capture for gait analysis","volume":"38","author":"Pfister","year":"2014","journal-title":"J. Med. Eng. Technol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/j.gaitpost.2015.05.002","article-title":"Accuracy of the Microsoft Kinect for measuring gait parameters during treadmill walking","volume":"42","author":"Xu","year":"2015","journal-title":"Gait Posture"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"4605","DOI":"10.3390\/s150304605","article-title":"New lower-limb gait asymmetry indices based on a depth camera","volume":"15","author":"Auvinet","year":"2015","journal-title":"Sensors"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Geerse, D.J., Coolen, B.H., and Roerdink, M. (2015). Kinematic Validation of a Multi-Kinect v2 Instrumented 10-m Walkway for Quantitative Gait Assessments. PLoS ONE, 10.","DOI":"10.1371\/journal.pone.0139913"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1016\/j.gaitpost.2014.08.006","article-title":"Detection of gait cycles in treadmill walking using a Kinect","volume":"41","author":"Auvinet","year":"2015","journal-title":"Gait Posture"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2166","DOI":"10.1016\/j.jbiomech.2015.05.021","article-title":"Gait assessment using the Microsoft Xbox One Kinect: Concurrent validity and inter-day reliability of spatiotemporal and kinematic variables","volume":"48","author":"Mentiplay","year":"2015","journal-title":"J. Biomech."},{"key":"ref_24","unstructured":"Fleiss, J. (1986). The Design and Analysis of Clinical Experiments, John Wiley & Sons."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1437","DOI":"10.3390\/s120201437","article-title":"Accuracy and resolution of kinect depth data for indoor mapping applications","volume":"12","author":"Khoshelham","year":"2012","journal-title":"Sensors"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/2\/194\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:18:49Z","timestamp":1760210329000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/2\/194"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,2,4]]},"references-count":25,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2016,2]]}},"alternative-id":["s16020194"],"URL":"https:\/\/doi.org\/10.3390\/s16020194","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,2,4]]}}}