{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:17:52Z","timestamp":1760242672061,"version":"build-2065373602"},"reference-count":38,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2016,2,4]],"date-time":"2016-02-04T00:00:00Z","timestamp":1454544000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Extracellular neural recording, with multi-electrode arrays (MEAs), is a powerful method used to study neural function at the network level. However, in a high density array, it can be costly and time consuming to integrate the active circuit with the expensive electrodes. In this paper, we present a 4 mm \u00d7 4 mm neural recording integrated circuit (IC) chip, utilizing IBM C4 bumps as recording electrodes, which enable a seamless active chip and electrode integration. The IC chip was designed and fabricated in a 0.13 \u03bcm BiCMOS process for both in vitro and in vivo applications. It has an input-referred noise of 4.6 \u03bcV                                                                       rms                                                 for the bandwidth of 10 Hz to 10 kHz and a power dissipation of 11.25 mW at 2.5 V, or 43.9 \u03bcW per input channel. This prototype is scalable for implementing larger number and higher density electrode arrays. To validate the functionality of the chip, electrical testing results and acute in vivo recordings from a rat barrel cortex are presented.<\/jats:p>","DOI":"10.3390\/s16020198","type":"journal-article","created":{"date-parts":[[2016,2,4]],"date-time":"2016-02-04T10:26:22Z","timestamp":1454581582000},"page":"198","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Active C4 Electrodes for Local Field Potential Recording Applications"],"prefix":"10.3390","volume":"16","author":[{"given":"Lu","family":"Wang","sequence":"first","affiliation":[{"name":"Department of Electrical and Computer Engineering, Boston University, 8 Saint Mary\u2019s St, Boston 02215, MA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Freedman","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, Boston University, 8 Saint Mary\u2019s St, Boston 02215, MA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mesut","family":"Sahin","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, New Jersey Institute of Technology, 323 Martin Luther King, Jr. Boulevard, University Heights Newark, Newark 07102, NJ, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8594-892X","authenticated-orcid":false,"given":"M.","family":"\u00dcnl\u00fc","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, Boston University, 8 Saint Mary\u2019s St, Boston 02215, MA, USA"},{"name":"Department of Biomedical Engineering, Boston University, 44 Cummington St, Boston 02215, MA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ronald","family":"Knepper","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering, Boston University, 8 Saint Mary\u2019s St, Boston 02215, MA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2016,2,4]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1038\/nature11076","article-title":"Reach and grasp by people with tetraplegia using a neurally controlled robotic arm","volume":"485","author":"Hochberg","year":"2012","journal-title":"Nature"},{"doi-asserted-by":"crossref","unstructured":"Obien, M., Deligkaris, K., Bullmann, T., Bakkum, D., and Frey, U. (2015). Revealing neuronal function through microelectrode array recordings. Front. Neurosci., 8.","key":"ref_2","DOI":"10.3389\/fnins.2014.00423"},{"doi-asserted-by":"crossref","unstructured":"Imfeld, K., Garenne, A., Martinoia, S., Koudelka-Hep, M., and Berdondini, L. (2007, January 2\u20135). Motivations and APS-based solution for high-resolution extracellular recording from in-vitro neuronal networks. Proceedings of the 3rd International IEEE\/EMBS Conference on Neural Engineering, Kohala Coast, HI, USA.","key":"ref_3","DOI":"10.1109\/CNE.2007.369652"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1186\/1743-0003-9-41","article-title":"Can motor volition be extracted from the spinal cord?","volume":"9","author":"Prasad","year":"2012","journal-title":"J. NeuroEng. Rehabil."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1152\/jn.00455.2012","article-title":"Differential effects of ketamine\/xylazine anesthesia on the cerebral and cerebellar cortical activities in the rat","volume":"109","author":"Ordek","year":"2013","journal-title":"J. Neurophysi."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1038\/nrn1585","article-title":"Invasive recordings from the human brain: Clinical insights and beyond","volume":"6","author":"Engel","year":"2005","journal-title":"Nature Rev. Neurosci."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1038\/nrn3241","article-title":"The origin of extracellular fields and currents\u2014EEG, ECoG, LFP and spikes","volume":"13","author":"Buzsaki","year":"2012","journal-title":"Nature Rev. Neurosci."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1109\/TBCAS.2014.2312552","article-title":"320-Channel Active Probe for High-Resolution Neuromonitoring and Responsive Neurostimulation","volume":"9","author":"Shulyzki","year":"2014","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1213","DOI":"10.1109\/JPROC.2008.922581","article-title":"The design of integrated circuits to observe brain activity","volume":"96","author":"Harrison","year":"2008","journal-title":"IEEE Proc."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2306","DOI":"10.1109\/JSSC.2003.819174","article-title":"A 128 \u00d7 128 CMOS biosensor array for extracellular recording of neural activity","volume":"38","author":"Eversmann","year":"2003","journal-title":"IEEE J. Solid State Circuits"},{"doi-asserted-by":"crossref","unstructured":"Frey, U., Heer, F., Pedron, R., Hafizovic, S., Greve, F., Sedivy, J., Kirstein, K., and Hierlemann, A. (2007, January 11\u201315). An 11k-electrode 126-channel high-density microelectrode array to interact with electrogenic cells. Proceedings of the IEEE International Solid-State Circuits Conference (ISSCC\u201907), San Francisco, CA, USA.","key":"ref_11","DOI":"10.1109\/ISSCC.2007.373636"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2064","DOI":"10.1109\/TBME.2008.919139","article-title":"Large-scale, high-resolution data acquisition system for extracellular recording of electrophysiological activity","volume":"55","author":"Imfeld","year":"2008","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/0006-8993(96)00321-6","article-title":"Single unit recording capabilities of a 100-microelectrode array","volume":"726","author":"Nordhausen","year":"1996","journal-title":"Brain Res."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1007\/s005420050054","article-title":"Development of a solder bump technique for contacting a three-dimensional multi electrode array","volume":"3","author":"Frieswijk","year":"1997","journal-title":"Microsyst. Technol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"995","DOI":"10.1109\/JSSC.2008.2010997","article-title":"256-channel neural recording and delta compression microsystem with 3D electrodes","volume":"44","author":"Aziz","year":"2009","journal-title":"IEEE J. Solid State Circuits"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1109\/TNSRE.2009.2024310","article-title":"Active Microelectronic Neurosensor Arrays for Implantable Brain Communication Interfaces","volume":"17","author":"Song","year":"2009","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1109\/JSSC.2012.2185338","article-title":"HermesE: A 96-Channel Full Data Rate Direct Neural Interface in 0.13 \u03bcm CMOS","volume":"47","author":"Gao","year":"2012","journal-title":"IEEE J. Solid State Circuits"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"2591","DOI":"10.1109\/JSSC.2009.2023159","article-title":"An implantable 64-channel wireless microsystem for single-unit neural recording","volume":"44","author":"Sodagar","year":"2009","journal-title":"IEEE J. Solid State Circuits"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1109\/TBCAS.2013.2281772","article-title":"Massively-Parallel Neuromonitoring and Neurostimulation Rodent Headset With Nanotextured Flexible Microelectrodes","volume":"7","author":"Bagheri","year":"2013","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1109\/TNSRE.2013.2279403","article-title":"High-Density Intracortical Microelectrode Arrays With Multiple Metallization Layers for Fine-Resolution Neuromonitoring and Neurostimulation","volume":"21","author":"Gabran","year":"2013","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1109\/JSSC.2013.2284347","article-title":"An Implantable 455-Active-Electrode 52-Channel CMOS Neural Probe","volume":"49","author":"Lopez","year":"2014","journal-title":"IEEE J. Solid State Circuits"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"958","DOI":"10.1109\/JSSC.2003.811979","article-title":"A low-power low-noise CMOS amplifier for neural recording applications","volume":"38","author":"Harrison","year":"2003","journal-title":"IEEE J. Solid State Circuits"},{"doi-asserted-by":"crossref","unstructured":"Yun, X., Kim, D., Stana\u0107evi\u0107, M., and Mainen, Z. (2007, January 22\u201326). Low-Power High-Resolution 32-channel Neural Recording System. Proceedings of the 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC\u201907), Lyon, France.","key":"ref_23","DOI":"10.1109\/IEMBS.2007.4352804"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1109\/TBCAS.2011.2163404","article-title":"A Low-Power 32-Channel Digitally Programmable Neural Recording Integrated Circuit","volume":"5","author":"Wattanapanitch","year":"2011","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"unstructured":"Han, D., Zheng, Y., Rajkumar, R., Dawe, G., and Je, M. (2013, January 17\u201321). A 0.45 V 100-Channel Neural-Recording IC With Sub-\u03bcW\/Channel Consumption in 0.18 \u03bcm CMOS. Proceedings of the 2013 IEEE International Solid-State Circuits Conference Digest of Technical Papers (ISSCC), San Francisco, CA, USA.","key":"ref_25"},{"unstructured":"Wright, S., Polastre, R., Gan, H., Buchwalter, L., Horton, R., Andry, P., Sprogis, E., Patel, C., Tsang, C., and Knickerbocker, J. (June, January 30). Characterization of micro-bump C4 interconnects for Si-carrier SOP applications. Proceedings of the 56th Electronic Components and Technology Conference, San Diego, CA, USA.","key":"ref_26"},{"doi-asserted-by":"crossref","unstructured":"Wen, S., Park, K., Thompson, P., Shirley, D., Lee, J., and Park, H. (2013, January 11\u201314). Flip chip assembly with advanced RDL technology. Proceedings of the 2013 14th International Conference on Electronic Packaging Technology (ICEPT), Dalian, China.","key":"ref_27","DOI":"10.1109\/ICEPT.2013.6756421"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.1109\/TBME.2005.847523","article-title":"Impedance Characterization and Modeling of Electrodes for Biomedical Applications","volume":"52","author":"Frank","year":"2005","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/j.neucom.2009.09.006","article-title":"Electrical Modeling of the Cell-Electrode Interface for Recording Neural Activity from High-Density Microelectrode Arrays","volume":"73","author":"Joye","year":"2009","journal-title":"Neurocomput. Elsevier"},{"unstructured":"Higuera, A. (2016). Neural Interface Model for a Pt\/Au C4 Bump Microelectrode Array, Unpublished work.","key":"ref_30"},{"doi-asserted-by":"crossref","unstructured":"Wang, L., Freedman, D.S., Knepper, R.W., \u00dcnl\u00fc, M.S., and Sahin, M. (2011, January 10\u201312). A 16 \u00d7 16 Multi-electrode Array with Integrated CMOS Amplifiers for Neural Signal Recording. Proceedings of the 2011 IEEE Biomedical Circuits and Systems Conference (BioCAS), San Diego, CA, USA.","key":"ref_31","DOI":"10.1109\/BioCAS.2011.6107732"},{"unstructured":"Carusone, T.C., Johns, D.A., and Martin, K.W. (2011). Analog Integrated Circuit Design, John Wiley & Sons. [2nd ed.].","key":"ref_32"},{"doi-asserted-by":"crossref","unstructured":"Majidzadeh, V., Schmid, A., and Leblebici, Y. (2011, January 10\u201312). A 16-channel 220 \u03bcW neural recording IC with embedded delta compression. Proceedings of the 2011 IEEE Biomedical Circuits and Systems Conference (BioCAS), San Diego, CA, USA.","key":"ref_33","DOI":"10.1109\/BioCAS.2011.6107714"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1109\/TBCAS.2013.2258669","article-title":"Data Compression in Brain-Machine\/Computer Interfaces Based on the Walsh-Hadamard Transform","volume":"8","author":"Jannesari","year":"2014","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"doi-asserted-by":"crossref","unstructured":"Yazdani, N., Rashidi, A., Sodagar, A.M., and Mohebbi, M. (2014, January 22\u201324). Reduction of spatial data redundancy in implantable multi-channel neural recording microsystems. Proceedings of the 2014 IEEE Biomedical Circuits and Systems Conference (BioCAS), Lausanne, Switzerland.","key":"ref_35","DOI":"10.1109\/BioCAS.2014.6981699"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1016\/j.snb.2003.12.078","article-title":"Development of an electroless post-processing technique for depositing gold as electrode material on CMOS devices","volume":"99","author":"Berdondini","year":"2004","journal-title":"Sens. Actuators B Chem."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1109\/TBCAS.2007.893181","article-title":"Brain-silicon interface for high-resolution in vitro neural recording","volume":"1","author":"Aziz","year":"2007","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1016\/j.medengphy.2011.03.006","article-title":"New prototype assembly methods for biosensor integrated circuits","volume":"33","author":"Graham","year":"2011","journal-title":"Med. Eng. Phys."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/2\/198\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:18:49Z","timestamp":1760210329000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/2\/198"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,2,4]]},"references-count":38,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2016,2]]}},"alternative-id":["s16020198"],"URL":"https:\/\/doi.org\/10.3390\/s16020198","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2016,2,4]]}}}