{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T15:23:56Z","timestamp":1785511436050,"version":"3.56.0"},"reference-count":21,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2016,4,8]],"date-time":"2016-04-08T00:00:00Z","timestamp":1460073600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000266","name":"EPSRC","doi-asserted-by":"publisher","award":["EP\/L01498X\/1"],"award-info":[{"award-number":["EP\/L01498X\/1"]}],"id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Saudi Arabian Cultural Bureau in London"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>When designing micro-scale tactile probes, a design trade-off must be made between the stiffness and flexibility of the probing element. The probe must be flexible enough to ensure sensitive parts are not damaged during contact, but it must be stiff enough to overcome attractive surface forces, ensure it is not excessively fragile, easily damaged or sensitive to inertial loads. To address the need for a probing element that is both flexible and stiff, a novel micro-scale tactile probe has been designed and tested that makes use of an active suspension structure. The suspension structure is used to modulate the probe stiffness as required to ensure optimal stiffness conditions for each phase of the measurement process. In this paper, a novel control system is presented that monitors and controls stiffness, allowing two probe stiffness values (\u201cstiff\u201d and \u201cflexible\u201d) to be defined and switched between. During switching, the stylus tip undergoes a displacement of approximately 18 \u00b5m, however, the control system is able ensure a consistent flexible mode tip deflection to within 12 nm in the vertical axis. The overall uncertainty for three-dimensional displacement measurements using the probing system is estimated to be 58 nm, which demonstrates the potential of this innovative variable stiffness micro-scale probe system.<\/jats:p>","DOI":"10.3390\/s16040492","type":"journal-article","created":{"date-parts":[[2016,4,8]],"date-time":"2016-04-08T21:02:38Z","timestamp":1460149358000},"page":"492","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["Performance Assessment of a New Variable Stiffness Probing System for Micro-CMMs"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3927-7280","authenticated-orcid":false,"given":"Khalid","family":"Alblalaihid","sequence":"first","affiliation":[{"name":"Manufacturing Metrology Team, Advanced Manufacturing Metrology Research Group, Faculty of Engineering, The University of Nottingham, Nottingham NG7 2RD, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9165-2466","authenticated-orcid":false,"given":"Peter","family":"Kinnell","sequence":"additional","affiliation":[{"name":"EPSRC Centre for Innovative Manufacturing in Intelligent Automation, Wolfson School of Mechanical and Manufacturing Engineering, Loughborough University, Loughborough LE11 3UZ, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simon","family":"Lawes","sequence":"additional","affiliation":[{"name":"Manufacturing Metrology Team, Advanced Manufacturing Metrology Research Group, Faculty of Engineering, The University of Nottingham, Nottingham NG7 2RD, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dorian","family":"Desgaches","sequence":"additional","affiliation":[{"name":"\u00c9cole Nationale D\u2019Ing\u00e9niurs De Saint-\u00c9tienne, Saint-\u00c9tienne 42023, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5777-067X","authenticated-orcid":false,"given":"Richard","family":"Leach","sequence":"additional","affiliation":[{"name":"Manufacturing Metrology Team, Advanced Manufacturing Metrology Research Group, Faculty of Engineering, The University of Nottingham, Nottingham NG7 2RD, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2016,4,8]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.precisioneng.2014.06.006","article-title":"A review of the existing performance verification infrastructure for micro-CMMs","volume":"39","author":"Claverley","year":"2015","journal-title":"Precis. Eng."},{"key":"ref_2","unstructured":"Leach, R. (2014). Fundamental Principles of Engineering Nanometrolog, William Andrew Publishing. [2nd ed.]."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1016\/j.precisioneng.2010.09.010","article-title":"Aspects of tactile probing on the micro scale","volume":"35","author":"Bos","year":"2011","journal-title":"Precis. Eng."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"094010","DOI":"10.1088\/0957-0233\/25\/9\/094010","article-title":"Study of a vibrating fiber probing system for 3-D micro-structures: Performance improvement","volume":"25","author":"Murakami","year":"2014","journal-title":"Meas. Sci. Technol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1088\/0957-0233\/17\/3\/S08","article-title":"Probing systems for dimensional micro- and nano-metrology","volume":"17","author":"Weckenmann","year":"2006","journal-title":"Meas. Sci. Technol."},{"key":"ref_6","unstructured":"K\u00fcng, A., and Meli, F. (2007, January 20\u201324). Comparison of three independent calibration methods applied to an ultra-precision micro-CMM. Proceedings of the International Conference of the European Society for Precision Engineering & Nanotechnology, Bremen, Germany."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.measurement.2013.10.037","article-title":"A 3D micro tactile sensor for dimensional metrology of micro structure with nanometer precision","volume":"48","author":"Lei","year":"2014","journal-title":"Measurement"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"094008","DOI":"10.1088\/0957-0233\/25\/9\/094008","article-title":"An analogue contact probe using a compact 3D optical sensor for micro\/nano coordinate?measuring machines","volume":"25","author":"Li","year":"2014","journal-title":"Meas. Sci. Technol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1507","DOI":"10.1007\/s00542-009-0967-2","article-title":"A vibrating micro-scale CMM probe for measuring high aspect ratio structures","volume":"16","author":"Claverley","year":"2010","journal-title":"Microsyst. Technol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/j.precisioneng.2012.12.008","article-title":"Development of a three-dimensional vibrating tactile probe for miniature CMMs","volume":"37","author":"Claverley","year":"2013","journal-title":"Precis. Eng."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1016\/j.sna.2015.04.029","article-title":"Fabrication and characterisation of a novel smart suspension for micro-CMM probes","volume":"232","author":"Alblalaihid","year":"2015","journal-title":"Sens. Actuators A Phys."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1016\/j.precisioneng.2015.08.004","article-title":"Variable stiffness probing systems for micro-coordinate measuring machines","volume":"43","author":"Alblalaihid","year":"2016","journal-title":"Precis. Eng."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1068","DOI":"10.2514\/3.21506","article-title":"Precision position control of piezoelectric actuators using charge feedback","volume":"18","author":"Main","year":"1995","journal-title":"J. Guid. Control Dyn."},{"key":"ref_14","unstructured":"Goldfarb, M., and Celanovic, N. (1996, January 22\u201328). Behavioral implications of piezoelectric stack actuators for control of micromanipulation. Proceedings of the IEEE International Conference on Robotics and Automation, Minneapolis, MN, USA."},{"key":"ref_15","unstructured":"Physik Instrumente. P-611.Z Piezo Z Stage. Available online: http:\/\/www.physikinstrumente.com\/download\/PI_Datasheet_P-611_Z_20150122.pdf."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1016\/j.sna.2009.01.017","article-title":"The effect of relative humidity, temperature and electrical field on leakage currents in piezo-ceramic actuators under dc bias","volume":"151","author":"Lipscomb","year":"2009","journal-title":"Sens. Actuators A Phys."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1109\/JMEMS.2009.2036584","article-title":"CMOS-MEMS Capacitive Humidity Sensor","volume":"19","author":"Lazarus","year":"2010","journal-title":"J. Microelectromech. Syst."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"2380","DOI":"10.1088\/0957-0233\/17\/9\/002","article-title":"Development of a coordinate measuring machine (CMM) touch probe using a multi-axis force sensor","volume":"17","author":"Kihwan","year":"2006","journal-title":"Meas. Sci. Technol."},{"key":"ref_19","unstructured":"Bos, E.J.C. (2008). Tactile 3D Probing System for Measuring MEMS with Nanometer Uncertainty. [Ph.D. Thesis, Eindhoven University of Technology]."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1299\/jamdsm.5.70","article-title":"An Open-Loop Positioning Method for Reduction of Influence of Nonlinearities in Piezoelectric Actuator","volume":"5","author":"Henmi","year":"2011","journal-title":"J. Adv. Mech. Des. Syst. Manuf."},{"key":"ref_21","unstructured":"Kinnell, P., Alblalaihid, K., and Lawes, S. Variable Stiffness Micro-Scale Tactile Probing System. Figshare. Available online: https:\/\/dx.doi.org\/10.17028\/rd.lboro.2061846."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/4\/492\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:21:56Z","timestamp":1760210516000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/4\/492"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,4,8]]},"references-count":21,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2016,4]]}},"alternative-id":["s16040492"],"URL":"https:\/\/doi.org\/10.3390\/s16040492","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,4,8]]}}}