{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,18]],"date-time":"2025-12-18T14:03:14Z","timestamp":1766066594327,"version":"build-2065373602"},"reference-count":18,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2016,5,26]],"date-time":"2016-05-26T00:00:00Z","timestamp":1464220800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The radial artery pulse is one of the major diagnostic indices used clinically in both Eastern and Western medicine. One of the prominent methods for measuring the radial artery pulse is the piezoresistive sensor array. Independence among channels and an appropriate sensor arrangement are important for effectively assessing the spatial-temporal information of the pulse. This study developed a circular-type seven-channel piezoresistive sensor array using face-down bonding (FDB) as one of the sensor combination methods. The three-layered housing structure that included independent pressure sensor units using the FDB method not only enabled elimination of the crosstalk among channels, but also allowed various array patterns to be created for effective pulse measurement. The sensors were arranged in a circular-type arrangement such that they could estimate the direction of the radial artery and precisely measure the pulse wave. The performance of the fabricated sensor array was validated by evaluating the sensor sensitivity per channel, and the possibility of estimating the blood vessel direction was demonstrated through a radial artery pulse simulator. We expect the proposed sensor to allow accurate extraction of the pulse indices for pulse diagnosis.<\/jats:p>","DOI":"10.3390\/s16060768","type":"journal-article","created":{"date-parts":[[2016,5,26]],"date-time":"2016-05-26T12:13:20Z","timestamp":1464264800000},"page":"768","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse"],"prefix":"10.3390","volume":"16","author":[{"given":"Min-Ho","family":"Jun","sequence":"first","affiliation":[{"name":"KM Fundamental Research Division, Korea Institute of Oriental Medicine (KIOM), Daejeon 305-811, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Young-Min","family":"Kim","sequence":"additional","affiliation":[{"name":"KM Fundamental Research Division, Korea Institute of Oriental Medicine (KIOM), Daejeon 305-811, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jang-Han","family":"Bae","sequence":"additional","affiliation":[{"name":"KM Fundamental Research Division, Korea Institute of Oriental Medicine (KIOM), Daejeon 305-811, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chang","family":"Jung","sequence":"additional","affiliation":[{"name":"KM Fundamental Research Division, Korea Institute of Oriental Medicine (KIOM), Daejeon 305-811, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jung-Hee","family":"Cho","sequence":"additional","affiliation":[{"name":"KM Fundamental Research Division, Korea Institute of Oriental Medicine (KIOM), Daejeon 305-811, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Young","family":"Jeon","sequence":"additional","affiliation":[{"name":"KM Fundamental Research Division, Korea Institute of Oriental Medicine (KIOM), Daejeon 305-811, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2016,5,26]]},"reference":[{"key":"ref_1","unstructured":"Nichols, W.W., and O\u2019Rourke, M.F. (2005). McDonald\u2019s Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles, Hodder Arnold. [5th ed.]."},{"key":"ref_2","unstructured":"Westerhof, N., Stergiopulos, N., and Noble, M.I.M. (2010). Snapshots of Hemodynamics: An Aid for Clinical Research and Graduate Education, Springer Science & Business Media. [2nd ed.]."},{"key":"ref_3","first-page":"1381","article-title":"Analysis of physical quantification of pulse types by pulse diagnosis","volume":"21","author":"Ryu","year":"2007","journal-title":"Korean J. Oriental Physiol. Pathol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"3S","DOI":"10.1016\/j.amjhyper.2004.10.009","article-title":"Clinical measurement of arterial stiffness obtained from noninvasive pressure waveforms","volume":"18","author":"Nichols","year":"2005","journal-title":"Am. J. Hypertens."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"11S","DOI":"10.1016\/j.amjhyper.2004.10.010","article-title":"Radial augmentation index: A useful and easily obtainable parameter for vascular aging","volume":"18","author":"Kohara","year":"2005","journal-title":"Am. J. Hypertens."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1161\/01.CIR.0000105767.94169.E3","article-title":"Arterial stiffness, wave reflections, and the risk of coronary artery disease","volume":"109","author":"Weber","year":"2004","journal-title":"Circulation"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Jeon, Y.J., Kim, J.U., Lee, H.J., Ryu, H.H., Lee, Y.J., and Kim, J.Y. (2011). A clinical study of the pulse wave characteristics at the three pulse diagnosis positions of chon, gwan and cheok. Evid. Based Complement. Altern. Med.","DOI":"10.1093\/ecam\/nep150"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.imr.2013.01.003","article-title":"Development of pulse diagnostic devices in Korea","volume":"2","author":"Kim","year":"2013","journal-title":"Integr. Med. Res."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1007\/s10665-012-9555-z","article-title":"Physical determining factors of the arterial pulse waveform: Theoretical analysis and calculation using the 1-D formulation","volume":"77","author":"Alastruey","year":"2012","journal-title":"J. Eng. Math."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1109\/JBHI.2014.2369821","article-title":"Comparison of Three Different Types of Wrist Pulse Signals by Their Physical Meanings and Diagnosis Performance","volume":"20","author":"Zuo","year":"2016","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"064702","DOI":"10.1063\/1.2783979","article-title":"Analysis of transverse wave as a propagation mode for the pressure pulse in large arteries","volume":"102","author":"Wang","year":"2007","journal-title":"J. Appl. Phys."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Bae, J.H., Jeon, Y.J., Kim, J.Y., and Kim, J.U. (2013). New assessment model of pulse depth based on sensor displacement in pulse diagnostic devices. Evid. Based Complement. Altern. Med.","DOI":"10.1155\/2013\/938641"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1186\/1475-925X-9-6","article-title":"Quantitative analysis of sensor for pressure waveform measurement","volume":"9","author":"Liu","year":"2010","journal-title":"Biomed. Eng. Online"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1784","DOI":"10.3390\/s110201784","article-title":"Measurement of blood pressure using an arterial pulsimeter equipped with a Hall device","volume":"11","author":"Lee","year":"2011","journal-title":"Sensors"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"745127","DOI":"10.1155\/2012\/745127","article-title":"Temporal and spatial properties of arterial pulsation measurement using pressure sensor array","volume":"2012","author":"Hu","year":"2012","journal-title":"Evid. Based Complement. Altern. Med."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"611","DOI":"10.3390\/s130100611","article-title":"Development of a radial pulse tonometric (RPT) sensor with a temperature compensation mechanism","volume":"13","author":"Yoo","year":"2013","journal-title":"Sensors"},{"key":"ref_17","first-page":"563958","article-title":"Novel diagnostic model for the deficient and excess pulse qualities","volume":"2012","author":"Kim","year":"2012","journal-title":"Evid. Based Complement. Altern. Med."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"813427","DOI":"10.1155\/2011\/813427","article-title":"Novel diagnostic algorithm for the floating and sunken pulse qualities and its clinical test","volume":"2011","author":"Kim","year":"2011","journal-title":"Evid. Based Complement. Altern. Med."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/6\/768\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:24:33Z","timestamp":1760210673000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/6\/768"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,5,26]]},"references-count":18,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2016,6]]}},"alternative-id":["s16060768"],"URL":"https:\/\/doi.org\/10.3390\/s16060768","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2016,5,26]]}}}