{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:19:28Z","timestamp":1760242768080,"version":"build-2065373602"},"reference-count":30,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2016,6,8]],"date-time":"2016-06-08T00:00:00Z","timestamp":1465344000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"the National Science Foundation of China","award":["No. 61171056, 61503346, 91336110"],"award-info":[{"award-number":["No. 61171056, 61503346, 91336110"]}]},{"name":"the China Postdoctoral Science Foundation","award":["No.2011M500544"],"award-info":[{"award-number":["No.2011M500544"]}]},{"name":"the Foundation of Key Laboratory","award":["9140C1204021008"],"award-info":[{"award-number":["9140C1204021008"]}]},{"DOI":"10.13039\/501100012166","name":"National Basic Research Program","doi-asserted-by":"publisher","award":["973 Program, under grant: 2010CB327601"],"award-info":[{"award-number":["973 Program, under grant: 2010CB327601"]}],"id":[{"id":"10.13039\/501100012166","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Despite its extreme significance, dynamic linearity measurement for high-g accelerometers has not been discussed experimentally in previous research. In this study, we developed a novel method using a dual-warhead Hopkinson bar to measure the dynamic linearity of a high-g acceleration sensor with a laser interference impact experiment. First, we theoretically determined that dynamic linearity is a performance indicator that can be used to assess the quality merits of high-g accelerometers and is the basis of the frequency response. We also found that the dynamic linearity of the dual-warhead Hopkinson bar without an accelerometer is 2.5% experimentally. Further, we verify that dynamic linearity of the accelerometer is 3.88% after calibrating the Hopkinson bar with the accelerometer. The results confirm the reliability and feasibility of measuring dynamic linearity for high-g accelerometers using this method.<\/jats:p>","DOI":"10.3390\/s16060840","type":"journal-article","created":{"date-parts":[[2016,6,8]],"date-time":"2016-06-08T11:26:26Z","timestamp":1465385186000},"page":"840","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["The Development of a Dual-Warhead Impact System for Dynamic Linearity Measurement of a High-g Micro-Electro-Mechanical-Systems (MEMS) Accelerometer"],"prefix":"10.3390","volume":"16","author":[{"given":"Yunbo","family":"Shi","sequence":"first","affiliation":[{"name":"Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030000, Shanxi, China"},{"name":"Key Laboratory of Instrumentation Science &amp; Dynamic Measurement, Ministry of Education, North University of China, Taiyuan 030000, Shanxi, China"}]},{"given":"Zhicai","family":"Yang","sequence":"additional","affiliation":[{"name":"Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030000, Shanxi, China"},{"name":"Key Laboratory of Instrumentation Science &amp; Dynamic Measurement, Ministry of Education, North University of China, Taiyuan 030000, Shanxi, China"}]},{"given":"Zongmin","family":"Ma","sequence":"additional","affiliation":[{"name":"Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030000, Shanxi, China"},{"name":"Key Laboratory of Instrumentation Science &amp; Dynamic Measurement, Ministry of Education, North University of China, Taiyuan 030000, Shanxi, China"}]},{"given":"Huiliang","family":"Cao","sequence":"additional","affiliation":[{"name":"Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030000, Shanxi, China"},{"name":"Key Laboratory of Instrumentation Science &amp; Dynamic Measurement, Ministry of Education, North University of China, Taiyuan 030000, Shanxi, China"}]},{"given":"Zhiwei","family":"Kou","sequence":"additional","affiliation":[{"name":"Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030000, Shanxi, China"},{"name":"Key Laboratory of Instrumentation Science &amp; Dynamic Measurement, Ministry of Education, North University of China, Taiyuan 030000, Shanxi, China"}]},{"given":"Dan","family":"Zhi","sequence":"additional","affiliation":[{"name":"Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030000, Shanxi, China"},{"name":"Key Laboratory of Instrumentation Science &amp; Dynamic Measurement, Ministry of Education, North University of China, Taiyuan 030000, Shanxi, China"}]},{"given":"Yanxiang","family":"Chen","sequence":"additional","affiliation":[{"name":"Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030000, Shanxi, China"},{"name":"Key Laboratory of Instrumentation Science &amp; Dynamic Measurement, Ministry of Education, North University of China, Taiyuan 030000, Shanxi, China"}]},{"given":"Hengzhen","family":"Feng","sequence":"additional","affiliation":[{"name":"Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030000, Shanxi, China"},{"name":"Key Laboratory of Instrumentation Science &amp; Dynamic Measurement, Ministry of Education, North University of China, Taiyuan 030000, Shanxi, China"}]},{"given":"Jun","family":"Liu","sequence":"additional","affiliation":[{"name":"Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030000, Shanxi, China"},{"name":"Key Laboratory of Instrumentation Science &amp; Dynamic Measurement, Ministry of Education, North University of China, Taiyuan 030000, Shanxi, China"}]}],"member":"1968","published-online":{"date-parts":[[2016,6,8]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.sna.2011.09.004","article-title":"Experimental study on the package of high-g accelerometer","volume":"173","author":"Liu","year":"2012","journal-title":"Sens. Actuators A"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1007\/s12206-013-0133-8","article-title":"Design, fabrication and experiment of a MEMS piezoresistive high-g accelerometer","volume":"27","author":"Zhao","year":"2013","journal-title":"J. Mech. Sci. Technol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/S0924-4247(02)00436-3","article-title":"Simulation, fabrication and testing of bulk micromachined 6H-SiC high-g piezoresistive accelerometers","volume":"104","author":"Atwell","year":"2003","journal-title":"Sens. Actuators A"},{"key":"ref_4","first-page":"33","article-title":"The Use of a Beryllium Hopkinson Bar to Characterize a Piezoresistive Accelerometer in Shock Environments","volume":"39","author":"Bateman","year":"1996","journal-title":"J. Inst. Environ. Sci."},{"key":"ref_5","unstructured":"Bateman, V.I., Leisher, W.B., Brown, F.A., and Davie, N.T. (1991, January 29\u201331). Calibration of a Hopkinson Bar with Transfer Standard. Proceedings of the 62nd Shock and Vibration Symposium, Springfield, VA, USA."},{"key":"ref_6","unstructured":"Umeda, A. (2003). Method and Device for Measuring Dynamic Linearity of Acceleration Sensor. (US20050160785), U.S. Patent."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"495","DOI":"10.3233\/JAE-131668","article-title":"Investigation of vacuum packaged MEMS gyroscope architec-ture\u2019s temperature robustness","volume":"41","author":"Cao","year":"2013","journal-title":"Int. J. Appl. Electromagn. Mech."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1155\/2006\/793564","article-title":"A Monolithic High-g SOI-MEMS Accelerometer for measuring Projectile Launch and Flight Accelerations","volume":"13","author":"Davis","year":"2006","journal-title":"Shock Vib."},{"key":"ref_9","first-page":"14","article-title":"Proven Sensor Performance for Emerging Shock Environments","volume":"48","author":"Bateman","year":"2014","journal-title":"Sound Vib."},{"key":"ref_10","unstructured":"Bateman, V.I. (2012, January 4\u20138). \u201cISO 16063-22 Amendment,\u201d-Part 22. Proceedings of the SAVIAC 83rd Shock and Vibration Symposium, New Orleas, LA, USA."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"15","DOI":"10.16879\/jkca.2015.15.2.015","article-title":"A Comparative Analysis of Motion Performance, Physical Activity, and Exercise Fatigue Degree during Inflatable Kayak and Hard Shall Kayak Sailing","volume":"15","author":"Lee","year":"2013","journal-title":"Off. J. Korean Assoc. Certif. Exerc. Prof."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1750","DOI":"10.1016\/j.microrel.2005.07.088","article-title":"Failure analysis issues in microelectromechanical systems","volume":"45","author":"Walraven","year":"2005","journal-title":"Microelectron. Reliab."},{"key":"ref_13","unstructured":"Umeda, A. (2006). Dynamic Matrix Sensitivity Measuring Instrument for Inertial Sensors, and Measuring Method Therefor. (WO 2004097433 A1)."},{"key":"ref_14","first-page":"63","article-title":"Accelerometer Calibration with the Hopkinson Pressure Bar","volume":"49","author":"Brow","year":"1963","journal-title":"Instr. Soc. Am. Prepr."},{"key":"ref_15","first-page":"52","article-title":"Transient Method of Calibrating a Piezoelectric Accelerometer for the High g-level Range","volume":"93","author":"Cannon","year":"1971","journal-title":"Am. Soc. Mech. Eng."},{"key":"ref_16","first-page":"352","article-title":"A Critical Study of the Hopkinson Pressure Bar, Philosophical Transactions","volume":"240","author":"Davies","year":"1948","journal-title":"Philos. Trans. R. Soc. Lond. A"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Wang, Y., Fan, J.B., Xu, P., and Zu, J. (2008). Shock calibration of the high-g triaxial accelerometer. IEEE Int. Conf. Instrum. Meas. Technol., 741\u2013745.","DOI":"10.1109\/IMTC.2008.4547135"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1016\/j.sna.2007.10.032","article-title":"High-performance mono-lithic triaxial piezoresistive shock accelerometers","volume":"141","author":"Dong","year":"2008","journal-title":"Sens. Actuators A"},{"key":"ref_19","unstructured":"Wang, L.L. (2005). Foundation of Stress Waves, National Defence Industry Press."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1016\/j.matdes.2004.08.021","article-title":"Finite-element simulation of wave propagation and dispersion in Hopkinson bar test","volume":"27","author":"Ramiez","year":"2006","journal-title":"Mater. Des."},{"key":"ref_21","unstructured":"Zukas, J.A. (1987). Impact Dynamics, Weapon Industry Press."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/0924-4247(95)00981-7","article-title":"Fabrication and characterization of high g-force, silicon piezoresistive accelerometers","volume":"48","author":"Ning","year":"1995","journal-title":"Sens. Actuators A"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/0924-4247(92)80181-2","article-title":"Analysis on twin-mass structure for a piezoresistive accelerometer","volume":"34","author":"Shaoqun","year":"1992","journal-title":"Sens. Actuators A"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Wang, Y., Fan, J.B., Xu, P., Zu, J., and Zhang, Z. (2008, January 12\u201315). Shock calibration of the high-g triaxial accelerometer. Proceedings of the Instrumentation and Measurement Technology Conference, Victoria, BC, Canada.","DOI":"10.1109\/IMTC.2008.4547135"},{"key":"ref_25","unstructured":"Li, Q.F. (2008). Research of The Shock Calibration with Laser-interferometry for High G Accelerometers. [Master\u2019s Thesis, North University of China]."},{"key":"ref_26","first-page":"68","article-title":"Shock sensor calibration for high-g value based on Hopkinson bar","volume":"8","author":"Xia","year":"2009","journal-title":"Electron. Des. Eng."},{"key":"ref_27","first-page":"11","article-title":"Shock calibration of a high-g piezoresistive microaccelerometer","volume":"10","author":"Li","year":"2010","journal-title":"Sens. World"},{"key":"ref_28","unstructured":"Hu, S.L. (2001). Laser Velocity Interferometry, National Defence Industry Press."},{"key":"ref_29","first-page":"34","article-title":"Primary Shock Calibration of Dynamic Performance of Differential Acceleration of Accelerometers with a Laser Interferometer","volume":"1","author":"Liang","year":"2005","journal-title":"Acta Metrol. Sin."},{"key":"ref_30","first-page":"78","article-title":"Shock calibration of piezoresistve high-g microaccelerometer","volume":"11","author":"Huan","year":"2003","journal-title":"J. Trans. Technol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/6\/840\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:25:10Z","timestamp":1760210710000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/6\/840"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,6,8]]},"references-count":30,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2016,6]]}},"alternative-id":["s16060840"],"URL":"https:\/\/doi.org\/10.3390\/s16060840","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2016,6,8]]}}}