{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T11:45:29Z","timestamp":1782474329893,"version":"3.54.5"},"reference-count":37,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2016,8,5]],"date-time":"2016-08-05T00:00:00Z","timestamp":1470355200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Studies show that the performance of soil water content monitoring (SWCM) sensors is affected by soil physical and chemical properties. However, the effect of organic matter on SWCM sensor responses remains less understood. Therefore, the objectives of this study are to (i) assess the effect of organic matter on the accuracy and precision of SWCM sensors using a commercially available soil water content monitoring sensor; and (ii) account for the organic matter effect on the sensor\u2019s accuracy. Sand columns with seven rates of oven-dried sawdust (2%, 4%, 6%, 8%, 10%, 12% and 18% v\/v, used as an organic matter amendment), thoroughly mixed with quartz sand, and a control without sawdust were prepared by packing quartz sand in two-liter glass containers. Sand was purposely chosen because of the absence of any organic matter or salinity, and also because sand has a relatively low cation exchange capacity that will not interfere with the treatment effect of the current work. Sensor readings (raw counts) were monitored at seven water content levels (0, 0.02, 0.04, 0.08, 0.12, 0.18, 0.24, and 0.30 cm3 cm\u22123) by uniformly adding the corresponding volumes of deionized water in addition to the oven-dry one. Sensor readings were significantly (p &lt; 0.05) affected by the organic matter level and water content. Sensor readings were strongly correlated with the organic matter level (R2 = 0.92). In addition, the default calibration equation underestimated the water content readings at the lower water content range (&lt;0.05 cm3 cm\u22123), while it overestimated the water content at the higher water content range (&gt;0.05 cm3 cm\u22123). A new polynomial calibration equation that uses raw count and organic matter content as covariates improved the accuracy of the sensor (RMSE = 0.01 cm3 cm\u22123). Overall, findings of this study highlight the need to account for the effect of soil organic matter content to improve the accuracy and precision of the tested sensor under different soils and environmental conditions.<\/jats:p>","DOI":"10.3390\/s16081239","type":"journal-article","created":{"date-parts":[[2016,8,5]],"date-time":"2016-08-05T10:10:24Z","timestamp":1470391824000},"page":"1239","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["Soil Water Content Sensor Response to Organic Matter Content under Laboratory Conditions"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9255-7564","authenticated-orcid":false,"given":"Ali","family":"Fares","sequence":"first","affiliation":[{"name":"College of Agriculture and Human Sciences, Prairie View A&amp;M University, Prairie View, TX 77446, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2453-2592","authenticated-orcid":false,"given":"Ripendra","family":"Awal","sequence":"additional","affiliation":[{"name":"College of Agriculture and Human Sciences, Prairie View A&amp;M University, Prairie View, TX 77446, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3480-3154","authenticated-orcid":false,"given":"Haimanote","family":"Bayabil","sequence":"additional","affiliation":[{"name":"College of Agriculture and Human Sciences, Prairie View A&amp;M University, Prairie View, TX 77446, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2016,8,5]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1016\/j.jhydrol.2013.11.018","article-title":"Importance of soil organic carbon on surface soil water content variability among agricultural fields","volume":"516","author":"Manns","year":"2014","journal-title":"J. Hydrol."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Polyakov, V., Fares, A., and Ryder, M.H. (2005). Calibration of a Capacitance System for Measuring Water Content of Tropical Soil. Vadose Zone J., 4.","DOI":"10.2136\/vzj2005.0028"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Provenzano, G., Rallo, G., and Ghazouani, H. (2015). Assessing field and laboratory calibration protocols for the diviner 2000 probe in a range of soils with different textures. J. Irrig. Drain. Eng., 142.","DOI":"10.1061\/(ASCE)IR.1943-4774.0000950"},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Vaz, C.M.P., Jones, S., Meding, M., and Tuller, M. (2013). Evaluation of Standard Calibration Functions for Eight Electromagnetic Soil Moisture Sensors. Vadose Zone J., 12.","DOI":"10.2136\/vzj2012.0160"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jhydrol.2014.02.051","article-title":"Soil moisture in the development of hydrological processes and its determination at different spatial scales","volume":"516","author":"Corradini","year":"2014","journal-title":"J. Hydrol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"358","DOI":"10.2136\/vzj2007.0143","article-title":"Soil Moisture Measurement for Ecological and Hydrological Watershed-Scale Observatories: A Review","volume":"7","author":"Robinson","year":"2008","journal-title":"Vadose. Zone J."},{"key":"ref_7","unstructured":"Campbell, C.S., Campbell, G.S., Cobos, D.R., and Bissey, L.L. Calibration and Evaluation of an Improved Low-Cost Soil Moisture Sensor. Available online: https:\/\/www. decagon.com."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"894","DOI":"10.2136\/sssaj2006.0420","article-title":"Temperature-Dependent Scaled Frequency: Improved Accuracy of Multisensor Capacitance Probes","volume":"71","author":"Fares","year":"2007","journal-title":"Soil Sci. Soc. Am."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/j.measurement.2014.04.007","article-title":"A critical review of soil moisture measurement","volume":"54","author":"Singh","year":"2014","journal-title":"Measurement"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/j.csi.2011.03.004","article-title":"A review of wireless sensors and networks\u2019 applications in agriculture","volume":"36","author":"Abbasi","year":"2014","journal-title":"Comput. Stand. Interfaces"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Cardenas-Lailhacar, B., and Dukes, M. (2015). Effect of Temperature and Salinity on the Precision and Accuracy of Landscape Irrigation Soil Moisture Sensor Systems. J. Irrig. Drain. Eng., 141.","DOI":"10.1061\/(ASCE)IR.1943-4774.0000847"},{"key":"ref_12","first-page":"1390","article-title":"Dual field calibration of capacitance and neutron soil water sensors in a shrinking-swelling clay soil","volume":"3","author":"Fares","year":"2004","journal-title":"Vadose. Zone J."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.jhydrol.2012.01.041","article-title":"Comparison of four soil moisture sensor types under field conditions in Switzerland","volume":"430\u2013431","author":"Mittelbach","year":"2012","journal-title":"J. Hydrol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1071\/SR15036","article-title":"Soil-specific calibration of capacitance sensors considering clay content and bulk density","volume":"54","author":"Parvin","year":"2016","journal-title":"Soil Res."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.scienta.2006.12.013","article-title":"Calibration and performance of moisture sensors in soilless substrates: ECH2O and Theta probes","volume":"112","author":"Nemali","year":"2007","journal-title":"Sci. Hortic."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1111\/j.1475-2743.2008.00154.x","article-title":"Comparison of three dielectric moisture sensors for measurement of water in saline sandy soil","volume":"24","author":"Inoue","year":"2008","journal-title":"Soil Use Manag."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"4858","DOI":"10.3390\/s110504858","article-title":"Improved Calibration Functions of Three Capacitance Probes for the Measurement of Soil Moisture in Tropical Soils","volume":"11","author":"Fares","year":"2011","journal-title":"Sensors"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1940","DOI":"10.2136\/sssaj2000.6461940x","article-title":"Soil material, temperature, and salinity effects on calibration of multisensor capacitance probes","volume":"64","author":"Baumhardt","year":"2000","journal-title":"Soil Sci. Soc. Am. J."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1071\/SR13009","article-title":"Soil texture and salinity effects on calibration of TDR300 dielectric moisture sensor","volume":"51","author":"Kargas","year":"2013","journal-title":"Soil Res."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1061\/(ASCE)IR.1943-4774.0000647","article-title":"Calibration of the 10HS Soil Moisture Sensor for Southwest Florida Agricultural Soils","volume":"139","author":"Spelman","year":"2013","journal-title":"J. Irrig. Drain. Eng."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/j.geoderma.2003.09.004","article-title":"Soil physical quality: Part I. Theory, effects of soil texture, density, and organic matter, and effects on root growth","volume":"120","author":"Dexter","year":"2004","journal-title":"Geoderma"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1016\/j.geoderma.2008.01.022","article-title":"Complexed organic matter controls soil physical properties","volume":"144","author":"Dexter","year":"2008","journal-title":"Geoderma"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1097\/SS.0b013e318182b063","article-title":"Response of selected soil physical and hydrologic properties to manure amendment rates, levels, and types","volume":"173","author":"Fares","year":"2008","journal-title":"Soil Sci."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"372","DOI":"10.4236\/ojss.2012.24044","article-title":"Effect of Organic Matter Amendment on Hydraulic and Pore Characteristics of a Clay Loam Soil","volume":"2","author":"Eusufzai","year":"2012","journal-title":"Open J. Soil Sci."},{"key":"ref_25","unstructured":"Cobos, D. Measurement Volume of Decagon Volumetric Water Content Sensors. Available online: http:\/\/manuals.decagon.com\/Application%20Notes\/14955_VWC%20Sensor%20Measurement%20Volumes_Web.pdf."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"39","DOI":"10.2166\/wcc.2015.025","article-title":"Irrigation water requirements for seed corn and coffee under potential climate change scenarios","volume":"7","author":"Fares","year":"2015","journal-title":"J. Water Clim. Chang."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1016\/S1002-0160(09)60153-3","article-title":"Adjusting Temperature and Salinity Effects on Single Capacitance Sensors","volume":"19","author":"Fares","year":"2009","journal-title":"Pedosphere"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.2136\/vzj2004.0138","article-title":"In Situ Comparison of Three Dielectric Soil Moisture Sensors in Drip Irrigated Sandy Soils","volume":"4","author":"Plauborg","year":"2005","journal-title":"Vadose Zone J."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Wu, B., Han, H., He, J., Zhang, J., Cui, L., Jia, Z., and Yang, W. (2014). Field-Specific Calibration and Evaluation of ECHO EC-5 Sensor for Sandy Soils. Soil Sci. Soc. Am. J., 78.","DOI":"10.2136\/sssaj2013.05.0209"},{"key":"ref_30","unstructured":"Decagon Devices product manual (2016). 10HS Soil Moisture Sensor, Decagon Devices. Inc.. Available online: http:\/\/manuals.decagon.com\/Manuals\/13508_10HS_Web.pdf."},{"key":"ref_31","unstructured":"R Development Core Team (2015). R: A Language and Environment for Statistical Computing, R Foundation for Statistical Computing."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1061\/(ASCE)IR.1943-4774.0000449","article-title":"Performance Analysis and Calibration of a New Low-Cost Capacitance Soil Moisture Sensor","volume":"138","author":"Kargas","year":"2012","journal-title":"J. Irrig. Drain. Eng."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/j.jhydrol.2014.01.026","article-title":"Soil moisture at local scale: Measurements and simulations","volume":"516","author":"Romano","year":"2014","journal-title":"J. Hydrol."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/S0016-7061(03)00094-6","article-title":"Effect of soil organic carbon on soil water retention","volume":"116","author":"Rawls","year":"2003","journal-title":"Geoderma"},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Fares, A., Safeeq, M., Awal, R., Fares, S., and Dogan, A. (2016). Effect of Temperature Hysteresis and Intra-Sensor Variability on Single Capacitance Soil Moisture Sensors in an Oxisol. Vadose. Zone J., 15.","DOI":"10.2136\/vzj2015.07.0098"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"548","DOI":"10.3390\/s7040548","article-title":"Simulated effects of soil temperature and salinity on capacitance sensor measurements","volume":"7","author":"Schwank","year":"2007","journal-title":"Sensors"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1061\/(ASCE)IR.1943-4774.0000418","article-title":"Comparison of laboratory and field calibration of a soil-moisture capacitance probe for various soils","volume":"138","author":"Kinzli","year":"2011","journal-title":"J. Irrig. Drain. Eng."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/8\/1239\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:27:52Z","timestamp":1760210872000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/8\/1239"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,8,5]]},"references-count":37,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2016,8]]}},"alternative-id":["s16081239"],"URL":"https:\/\/doi.org\/10.3390\/s16081239","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,8,5]]}}}