{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T05:40:16Z","timestamp":1776231616884,"version":"3.50.1"},"reference-count":31,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2016,8,22]],"date-time":"2016-08-22T00:00:00Z","timestamp":1471824000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100012336","name":"Major State Basic Research Development Program of China","doi-asserted-by":"publisher","award":["2015CB057704"],"award-info":[{"award-number":["2015CB057704"]}],"id":[{"id":"10.13039\/501100012336","id-type":"DOI","asserted-by":"publisher"}]},{"name":"National Nature Science Foundation of China","award":["51208061"],"award-info":[{"award-number":["51208061"]}]},{"name":"National Nature Science Foundation of China","award":["51278084"],"award-info":[{"award-number":["51278084"]}]},{"name":"National Nature Science Foundation of China","award":["51478080"],"award-info":[{"award-number":["51478080"]}]},{"name":"National Nature Science Foundation of China","award":["51421064"],"award-info":[{"award-number":["51421064"]}]},{"name":"Hunan Province Innovation Open Fund Project of China","award":["12K077"],"award-info":[{"award-number":["12K077"]}]},{"name":"Changsha University of Science and Technology Civil Engineering Innovation Project of China","award":["15ZDXK11"],"award-info":[{"award-number":["15ZDXK11"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A post-tensioning tendon duct filled with grout can effectively prevent corrosion of the reinforcement, maintain bonding behavior between the reinforcement and concrete, and enhance the load bearing capacity of concrete structures. In practice, grouting of the post-tensioning tendon ducts always causes quality problems, which may reduce structural integrity and service life, and even cause accidents. However, monitoring of the grouting compactness is still a challenge due to the invisibility of the grout in the duct during the grouting process. This paper presents a stress wave-based active sensing approach using piezoceramic transducers to monitor the grouting compactness in real time. A segment of a commercial tendon duct was used as research object in this study. One lead zirconate titanate (PZT) piezoceramic transducer with marble protection, called a smart aggregate (SA), was bonded on the tendon and installed in the tendon duct. Two PZT patch sensors were mounted on the top outside surface of the duct, and one PZT patch sensor was bonded on the bottom outside surface of the tendon duct. In the active sensing approach, the SA was used as an actuator to generate a stress wave and the PZT sensors were utilized to detect the wave response. Cement or grout in the duct functions as a wave conduit, which can propagate the stress wave. If the cement or grout is not fully filled in the tendon duct, the top PZT sensors cannot receive much stress wave energy. The experimental procedures simulated four stages during the grout pouring process, which includes empty status, half grouting, 90% grouting, and full grouting of the duct. Experimental results show that the bottom PZT sensor can detect the signal when the grout level increases towards 50%, when a conduit between the SA and PZT sensor is formed. The top PZT sensors cannot receive any signal until the grout process is completely finished. The wavelet packet-based energy analysis was adopted in this research to compute the total signal energy received by PZT sensors. Experimental results show that the energy levels of the PZT sensors can reflect the degree of grouting compactness in the duct. The proposed method has the potential to be implemented to monitor the tendon duct grouting compactness of the reinforced concrete structures with post tensioning.<\/jats:p>","DOI":"10.3390\/s16081343","type":"journal-article","created":{"date-parts":[[2016,8,22]],"date-time":"2016-08-22T10:40:33Z","timestamp":1471862433000},"page":"1343","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":75,"title":["Monitoring of Grouting Compactness in a Post-Tensioning Tendon Duct Using Piezoceramic Transducers"],"prefix":"10.3390","volume":"16","author":[{"given":"Tianyong","family":"Jiang","sequence":"first","affiliation":[{"name":"College of Civil Engineering and Architecture, Changsha University of Science and Technology, Changsha 410114, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9577-4540","authenticated-orcid":false,"given":"Qingzhao","family":"Kong","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, University of Houston, Houston, TX 77004, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenxi","family":"Wang","sequence":"additional","affiliation":[{"name":"College of Civil Engineering, Hunan University, Changsha 410082, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3044-2630","authenticated-orcid":false,"given":"Linsheng","family":"Huo","sequence":"additional","affiliation":[{"name":"School of Civil Engineering, Dalian University of Technology, Dalian 116024, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gangbing","family":"Song","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, University of Houston, Houston, TX 77004, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2016,8,22]]},"reference":[{"key":"ref_1","first-page":"411","article-title":"Experimental study of nondestructive testing for grouting quality in prestressed concrete T-beam","volume":"19","author":"Yang","year":"2006","journal-title":"J. Vib. Eng."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2376","DOI":"10.1016\/j.conbuildmat.2010.05.010","article-title":"Case studies on ungrouted tendon-duct in prestressed concrete models by SIBIE","volume":"24","author":"Yamada","year":"2010","journal-title":"Constr. Build. Mater."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/j.ndteint.2014.08.007","article-title":"Inhomogeneity reconstructions in tendon ducts via boundary integral equations","volume":"68","author":"Yaman","year":"2014","journal-title":"NDT E Int."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1016\/j.conbuildmat.2006.04.009","article-title":"Indentifying voids in plastic ducts in post-tensioning prestressed concrete members by resonant frenquency of impact-echo, SIBIE and tomography","volume":"21","author":"Muldoon","year":"2007","journal-title":"Constr. Build. Mater."},{"key":"ref_5","first-page":"73","article-title":"Experimental research on detection of duct grouting quality of prestressed corrugated pipe with ultrasonic","volume":"2","author":"Wang","year":"2015","journal-title":"Bridge Tunn. Constr. Mach."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/S0963-8695(01)00007-X","article-title":"Ultrasonic imaging of concrete members using an array system","volume":"34","author":"Krause","year":"2001","journal-title":"NDT E Int."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1061\/(ASCE)0899-1561(2003)15:3(235)","article-title":"Ultrasonic imaging of concrete elements using reconstruction by synthetic aperture focusing technique","volume":"15","author":"Schickert","year":"2003","journal-title":"J. Mater. Civ. Eng."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1061\/(ASCE)0899-1561(2003)15:3(287)","article-title":"Non-destructive evaluation of concrete infrastructure with ground penetrating radar","volume":"15","author":"Maierhofer","year":"2003","journal-title":"J. Mater. Civ. Eng."},{"key":"ref_9","unstructured":"Bungey, J.H., Millard, S.G., and Shaw, M.R. (1997, January 8). Radar assessment of post-tensioned concrete. Proceedings of the 7th Internetional Conference on Structural Faults and Repair, Edinburgh, UK."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"327","DOI":"10.3390\/s8010327","article-title":"Sensitivity of PZT impedance sensors for damage detection of concrete structures","volume":"8","author":"Yang","year":"2008","journal-title":"Sensors"},{"key":"ref_11","unstructured":"Xu, B., Wang, Y., Dyke, S.J., and Huang, T. (2014, January 27\u201329). Cracking monitoring of RC joints under cyclic loadings based on wavelet packet analysis on embedded PZT measurements. Proceedings of the 14th ASCE International Conference on Engineering, Science, Construction and Operations in Challenging Environments, St. Louis, MO, USA."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"087001","DOI":"10.1088\/0964-1726\/22\/8\/087001","article-title":"Proof-of-concept Study of Monitoring Bolt Connection Status using a Piezoelectric based Active Sensing Method","volume":"22","author":"Wang","year":"2013","journal-title":"Smart Mater. Struct."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"639","DOI":"10.3390\/s16050639","article-title":"Damage Detection Based on Power Dissipation Measured with PZT Sensors through the Combination of Electro-Mechanical Impedances and Guided Waves","volume":"16","author":"Sevillano","year":"2016","journal-title":"Sensors"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"997","DOI":"10.12989\/sss.2015.15.4.997","article-title":"Detection of flexural damage stages for RC beams using piezoelectric sensors (PZT)","volume":"15","author":"Karayannis","year":"2015","journal-title":"Smart Struct. Syst."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.conbuildmat.2015.12.019","article-title":"Experimental damage evaluation of reinforced concrete steel bars using piezoelectric sensors","volume":"105","author":"Karayannis","year":"2016","journal-title":"Constr. Build. Mater."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1016\/j.engstruct.2016.02.014","article-title":"Investigation of a new experimental method for damage assessment of RC beams failing in shear using piezoelectric transducers","volume":"114","author":"Voutetaki","year":"2016","journal-title":"Eng. Struct."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.1080\/15732479.2013.831908","article-title":"Damage detection in concrete structures using a simultaneously activated multi-mode PZT active sensing system: numerical modelling","volume":"10","author":"Providakis","year":"2014","journal-title":"Struct. Infrastruct. Eng."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"085021","DOI":"10.1088\/0964-1726\/25\/8\/085021","article-title":"Non-destructive concrete strength evaluation using smart piezoelectric transducer\u2013a comparative study","volume":"25","author":"Lim","year":"2016","journal-title":"Smart Mater. Struct."},{"key":"ref_19","first-page":"1","article-title":"Applications of smart piezoelectric materials in a wireless admittance monitoring system (WiAMS) to Structures\u2013Tests in RC elements","volume":"5","author":"Chalioris","year":"2016","journal-title":"Case Stud. Constr. Mater."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1088\/0964-1726\/16\/2\/026","article-title":"An overheight vehicle-bridge collision monitoring system using piezoelectric transducer","volume":"16","author":"Song","year":"2007","journal-title":"Smart Mater. Struct."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1088\/0964-1726\/16\/4\/003","article-title":"Concrete structural health monitoring using embedded piezoceramic transducers","volume":"16","author":"Song","year":"2007","journal-title":"Smart Mater. Struct."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"033001","DOI":"10.1088\/0964-1726\/17\/3\/033001","article-title":"Smart aggregate: multi-functional sensors for concrete structures\u2013a tutorial and review","volume":"17","author":"Song","year":"2008","journal-title":"Smart Mater. Struct."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1061\/(ASCE)ST.1943-541X.0000632","article-title":"Active debonding detection for large rectangular CFSTs based on wavelet packet energy spectrum with piezoceramics","volume":"139","author":"Xu","year":"2013","journal-title":"ASCE J. Struct. Eng."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.ymssp.2011.07.029","article-title":"Active interface debonding detection of a concrete-filled steel tube with PZT techniques using wavelet packet analysis","volume":"36","author":"Xu","year":"2013","journal-title":"Mech. Syst. Signal Process."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1177\/1475921706057978","article-title":"Debond detection using embedded piezoelectric elements in reinforced concrete structure\u2013part I: Experiment","volume":"5","author":"Wu","year":"2006","journal-title":"Struct. Health Monit."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1177\/1475921706057979","article-title":"Debond detection using embedded piezoelectric elements in reinforced concrete structure\u2013part II: Analysis and Algorithm","volume":"5","author":"Wu","year":"2006","journal-title":"Struct. Health Monit."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1088\/0964-1726\/24\/11\/115039","article-title":"Bond slip detection of steel plate and concrete beams using smart aggregates","volume":"24","author":"Qin","year":"2015","journal-title":"Smart Mater. Struct."},{"key":"ref_28","first-page":"373","article-title":"Damage evaluation in shear-critical reinforced concrete beam using piezoelectric transducers as smart aggregates","volume":"1","author":"Chalioris","year":"2015","journal-title":"Open Eng."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1837","DOI":"10.1088\/0964-1726\/15\/6\/038","article-title":"Concrete early-age strength monitoring using embedded piezoelectric transducers","volume":"15","author":"Gu","year":"2006","journal-title":"Smart Mater. Struct."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"631715","DOI":"10.1155\/2013\/631715","article-title":"Feasibility Study on Crack Detection of Pipelines Using Piezoceramic Transducers","volume":"2013","author":"Du","year":"2013","journal-title":"Int. J. Distrib. Sens. Netw."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"06014001","DOI":"10.1061\/(ASCE)CR.1943-5495.0000066","article-title":"Monitoring the Soil Freeze-Thaw Process Using Piezoceramic-Based Smart Aggregate","volume":"28","author":"Kong","year":"2014","journal-title":"J. Cold Reg. Eng."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/8\/1343\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:28:55Z","timestamp":1760210935000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/8\/1343"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,8,22]]},"references-count":31,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2016,8]]}},"alternative-id":["s16081343"],"URL":"https:\/\/doi.org\/10.3390\/s16081343","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,8,22]]}}}