{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,24]],"date-time":"2026-01-24T00:09:03Z","timestamp":1769213343772,"version":"3.49.0"},"reference-count":18,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2016,9,8]],"date-time":"2016-09-08T00:00:00Z","timestamp":1473292800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Microwave sensors in medical environments play a significant role due to the contact-less and non-invasive sensing mechanism to determine dielectric properties of tissue. In this work, a theranostic sensor based on Split Ring Resonators (SRRs) is presented that provides two operation modes to detect and treat tumor cells, exemplary in the liver. For the detection mode, resonance frequency changes due to abnormalities are evaluated, and in the treatment mode, microwave ablation is performed. The planar sensor structure can be integrated into a needle like a surgery tool that evokes challenges concerning size limitations and biocompatibility. To meet the size requirements and provide a reasonable operating frequency, properties of oval shaped SRRs are investigated. By elongating the radius of the SRR in one direction, the resonance frequency can be decreased significantly compared to circular SRR by a factor of two below 12 GHz. In order to validate the detection and treatment characteristics of the sensor, full wave simulations and measurements are examined. Clear resonance shifts are detected for loading the sensor structures with phantoms mimicking healthy and malignant tissue. For treatment mode evaluation, ex vivo beef liver tissue was ablated leading to a lesion zone 1.2 cm \u00d7 1 cm \u00d7 0.3 cm with a three minute exposure of maximum 2.1 W.<\/jats:p>","DOI":"10.3390\/s16091450","type":"journal-article","created":{"date-parts":[[2016,9,8]],"date-time":"2016-09-08T10:08:36Z","timestamp":1473329316000},"page":"1450","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Planar Microwave Sensor for Theranostic Therapy of Organic Tissue Based on Oval Split Ring Resonators"],"prefix":"10.3390","volume":"16","author":[{"given":"Carolin","family":"Reimann","sequence":"first","affiliation":[{"name":"Institute for Microwave Engineering and Photonics, Technische Universit\u00e4t Darmstadt, Merckstr. 25, Darmstadt 64283, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Margarita","family":"Puentes","sequence":"additional","affiliation":[{"name":"Institute for Microwave Engineering and Photonics, Technische Universit\u00e4t Darmstadt, Merckstr. 25, Darmstadt 64283, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthias","family":"Maasch","sequence":"additional","affiliation":[{"name":"Terahertz Sensors Group, Technische Universit\u00e4t Darmstadt, Merckstr. 25, Darmstadt 64283, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frank","family":"H\u00fcbner","sequence":"additional","affiliation":[{"name":"Institute of Diagnostic and Interventional Radiology, Goethe University, Theodor-Stern-Kai 7, Frankfurt am Main 60590, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Babak","family":"Bazrafshan","sequence":"additional","affiliation":[{"name":"Institute of Diagnostic and Interventional Radiology, Goethe University, Theodor-Stern-Kai 7, Frankfurt am Main 60590, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Vogl","sequence":"additional","affiliation":[{"name":"Institute of Diagnostic and Interventional Radiology, Goethe University, Theodor-Stern-Kai 7, Frankfurt am Main 60590, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Damm","sequence":"additional","affiliation":[{"name":"Terahertz Sensors Group, Technische Universit\u00e4t Darmstadt, Merckstr. 25, Darmstadt 64283, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rolf","family":"Jakoby","sequence":"additional","affiliation":[{"name":"Institute for Microwave Engineering and Photonics, Technische Universit\u00e4t Darmstadt, Merckstr. 25, Darmstadt 64283, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2016,9,8]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1667","DOI":"10.1109\/TBME.2015.2432137","article-title":"On the Opportunities and Challenges in Microwave Medical Sensing and Imaging","volume":"62","author":"Chandra","year":"2015","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1109\/MPUL.2011.942603","article-title":"Thermal tumor ablation in clinical use","volume":"2","author":"Brace","year":"2011","journal-title":"Pulse IEEE"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Reimann, C., Puentes, M., Sch\u00fc\u00dfler, M., and Jakoby, R. (2016, January 14\u201316). Design and Realization of a Microwave Applicator for Diagnosis and Thermal Ablation Treatment of Cancerous Tissue. Procedings of the 10th German Microwave Conference, Bochum, Germany.","DOI":"10.1109\/GEMIC.2016.7461584"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1109\/PROC.1980.11589","article-title":"RF - field interactions with biological systems: Electrical properties and biophysical mechanisms","volume":"68","author":"Schwan","year":"1980","journal-title":"Proc. IEEE"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.1109\/TMTT.2005.845211","article-title":"Equivalent-circuit models for split-ring resonators and complementary split-ring resonators coupled to planar transmission lines","volume":"53","author":"Baena","year":"2005","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_6","unstructured":"Marqu\u00e9s, R., Mart\u00edn, F., and Sorolla, M. (2011). Metamaterials with Negative Parameters: Theory, Design and Microwave Applications, John Wiley & Sons."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"144440","DOI":"10.1103\/PhysRevB.65.144440","article-title":"Role of bianisotropy in negative permeability and left-handed metamaterials","volume":"65","author":"Medina","year":"2002","journal-title":"Phys. Rev. B"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"149","DOI":"10.6028\/bulletin.083","article-title":"On the self inductance of circles","volume":"4","author":"Rosa","year":"1908","journal-title":"Bull. Bur. Stand."},{"key":"ref_9","unstructured":"Bronstein, I.N., Semendjajew, K.A., Musiol, G., and M\u00fchlig, H. (2005). Taschenbuch der Mathematik, Verlag Harri Deutsch."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2271","DOI":"10.1088\/0031-9155\/41\/11\/003","article-title":"The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues","volume":"41","author":"Gabriel","year":"1996","journal-title":"Phys. Med. Biol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"4707","DOI":"10.1088\/0031-9155\/52\/15\/022","article-title":"Dielectric properties of human normal, malignant and cirrhotic liver tissue: in vivo and ex vivo measurements from 0.5 to 20 GHz using a precision open-ended coaxial probe","volume":"52","author":"Lazebnik","year":"2007","journal-title":"Phys. Med. Biol."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Chen, L., Ong, C., Neo, C., Varadan, V., and Varadan, V. (2004). Microwave Electronics Measurement and Materials Characterization, John Wiley & Sons, Ltd.","DOI":"10.1002\/0470020466"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1152\/jappl.1948.1.2.93","article-title":"Analysis of tissue and arterial blood temperatures in the resting human forearm","volume":"1","author":"Pennes","year":"1948","journal-title":"J. Appl. Physiol."},{"key":"ref_14","unstructured":"Moros, E. (2012). Physics oF Thermal Therapy: Fundamentals and Clinical Applications, CRC Press."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"4245","DOI":"10.1088\/0031-9155\/50\/18\/001","article-title":"Tissue-mimicking phantom materials for narrowband and ultrawideband microwave applications","volume":"50","author":"Lazebnik","year":"2005","journal-title":"Phys. Med. Biol."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Puentes, M., Bashir, F., Schussler, M., and Jakoby, R. (September, January 28). Dual mode microwave tool for dielectric analysis and thermal ablation treatment of organic tissue. Proceedings of the 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), San Diego, CA, USA.","DOI":"10.1109\/EMBC.2012.6346850"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Puentes, M., Schussler, M., Damm, C., and Jakoby, R. (2014, January 6\u20139). Evolution of a microwave instrument for analysis and thermal ablation of organic tissue. Proceedings of the 2014 44th European Microwave Conference (EuMC), Rome, Italy.","DOI":"10.1109\/EuMC.2014.6986425"},{"key":"ref_18","unstructured":"Puentes, M. (2014). Planar Metamaterial Based Microwave Sensor Arrays for Biomedical Analysis and Treatment, Springer. Chapter 6."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/9\/1450\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:30:22Z","timestamp":1760211022000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/9\/1450"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,9,8]]},"references-count":18,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2016,9]]}},"alternative-id":["s16091450"],"URL":"https:\/\/doi.org\/10.3390\/s16091450","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,9,8]]}}}