{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T03:10:30Z","timestamp":1785294630625,"version":"3.55.0"},"reference-count":43,"publisher":"MDPI AG","issue":"10","license":[{"start":{"date-parts":[[2016,9,28]],"date-time":"2016-09-28T00:00:00Z","timestamp":1475020800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>An application of spectral domain optical coherence tomography (SD-OCT) was demonstrated for a fast industrial inspection of an optical thin film panel. An optical thin film sample similar to a liquid crystal display (LCD) panel was examined. Two identical SD-OCT systems were utilized for parallel scanning of a complete sample in half time. Dual OCT inspection heads were utilized for transverse (fast) scanning, while a stable linear motorized translational stage was used for lateral (slow) scanning. The cross-sectional and volumetric images of an optical thin film sample were acquired to detect the defects in glass and other layers that are difficult to observe using visual inspection methods. The rapid inspection enabled by this setup led to the early detection of product defects on the manufacturing line, resulting in a significant improvement in the quality assurance of industrial products.<\/jats:p>","DOI":"10.3390\/s16101598","type":"journal-article","created":{"date-parts":[[2016,9,28]],"date-time":"2016-09-28T10:56:13Z","timestamp":1475060173000},"page":"1598","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":54,"title":["Fast Industrial Inspection of Optical Thin Film Using Optical Coherence Tomography"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4488-8860","authenticated-orcid":false,"given":"Muhammad","family":"Shirazi","sequence":"first","affiliation":[{"name":"School of Electronics Engineering, College of IT Engineering, Kyungpook National University, 80 Daehak-ro, Bukgu, Daegu 41566, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kibeom","family":"Park","sequence":"additional","affiliation":[{"name":"School of Electronics Engineering, College of IT Engineering, Kyungpook National University, 80 Daehak-ro, Bukgu, Daegu 41566, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruchire","family":"Wijesinghe","sequence":"additional","affiliation":[{"name":"School of Electronics Engineering, College of IT Engineering, Kyungpook National University, 80 Daehak-ro, Bukgu, Daegu 41566, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyosang","family":"Jeong","sequence":"additional","affiliation":[{"name":"Oz-tec Co. Ltd., Office 901, IT Convergence Industrial Building, 47 Gyeongdae-ro, 17-gil, Bukgu, Daegu 41566, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sangyeob","family":"Han","sequence":"additional","affiliation":[{"name":"Oz-tec Co. Ltd., Office 901, IT Convergence Industrial Building, 47 Gyeongdae-ro, 17-gil, Bukgu, Daegu 41566, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pilun","family":"Kim","sequence":"additional","affiliation":[{"name":"Oz-tec Co. Ltd., Office 901, IT Convergence Industrial Building, 47 Gyeongdae-ro, 17-gil, Bukgu, Daegu 41566, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mansik","family":"Jeon","sequence":"additional","affiliation":[{"name":"School of Electronics Engineering, College of IT Engineering, Kyungpook National University, 80 Daehak-ro, Bukgu, Daegu 41566, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeehyun","family":"Kim","sequence":"additional","affiliation":[{"name":"School of Electronics Engineering, College of IT Engineering, Kyungpook National University, 80 Daehak-ro, Bukgu, Daegu 41566, Korea"},{"name":"Oz-tec Co. Ltd., Office 901, IT Convergence Industrial Building, 47 Gyeongdae-ro, 17-gil, Bukgu, Daegu 41566, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2016,9,28]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/0262-8856(95)01035-1","article-title":"Future directions in industrial machine vision: A case study of semiconductor manufacturing applications","volume":"14","author":"Rao","year":"1996","journal-title":"Image Vis. Comput."},{"key":"ref_2","unstructured":"Kim, J.-H., Ahn, S., Jeon, J.W., and Byun, J.-E. (2001, January 12\u201316). A high-speed high-resolution vision system for the inspection of TFT LCD. 2001. Proceedings of the IEEE International Symposium on Industrial Electronics (ISIE 2001), Pusan, Korea."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1007\/s00170-003-1832-6","article-title":"Automatic defect inspection for lcds using singular value decomposition","volume":"25","author":"Lu","year":"2005","journal-title":"Int. J. Adv. Manuf. Technol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0957-4174(98)00079-7","article-title":"Building a rule-based machine-vision system for defect inspection on apple sorting and packing lines","volume":"16","author":"Wen","year":"1999","journal-title":"Expert Syst. Appl."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1006\/rtim.2001.0231","article-title":"Real-time vision-based system for textile fabric inspection","volume":"7","author":"Stojanovic","year":"2001","journal-title":"Real-Time Imaging"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1006\/rtim.1998.0153","article-title":"Real-time defect inspection of textured surfaces","volume":"6","author":"Baykut","year":"2000","journal-title":"Real-Time Imaging"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.displa.2008.03.006","article-title":"Evaluation of TFT-LCD defects based on human visual perception","volume":"30","author":"Park","year":"2009","journal-title":"Displays"},{"key":"ref_8","first-page":"2371","article-title":"Automatic detection of region-mura defect in TFT-LCD","volume":"E87-D","author":"Lee","year":"2004","journal-title":"IEICE Trans. Inf. Syst."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Gladden, L.F. (1997). Process tomography: Principles, techniques and applications. Meas. Sci. Technol., 8.","DOI":"10.1088\/0957-0233\/8\/4\/021"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1016\/S0168-583X(02)01689-0","article-title":"X-ray micro-tomography an attractive characterisation technique in materials science","volume":"200","author":"Salvo","year":"2003","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. B Beam Interact. Mater. Atoms."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1178","DOI":"10.1126\/science.1957169","article-title":"Optical coherence tomography","volume":"254","author":"Huang","year":"1991","journal-title":"Science"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1038\/86589","article-title":"Ultrahigh-resolution ophthalmic optical coherence tomography","volume":"7","author":"Drexler","year":"2001","journal-title":"Nat. Med."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"6727","DOI":"10.1364\/OL.39.006727","article-title":"Dual spectrometer system with spectral compounding for 1-\u03bcm optical coherence tomography in vivo","volume":"39","author":"Cui","year":"2014","journal-title":"Opt. Lett."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/j.ajo.2014.12.004","article-title":"Diagnostic capability of peripapillary retinal thickness in glaucoma using 3d volume scans","volume":"159","author":"Simavli","year":"2014","journal-title":"Am. J. Ophthalmol."},{"key":"ref_15","first-page":"1626","article-title":"Fiber-based polarization-sensitive swept-source oct of the human retina at 1 \u03bcm","volume":"55","author":"Braaf","year":"2014","journal-title":"Investig. Ophtalmol. Vis. Sci."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1109\/TBME.2010.2096816","article-title":"Handheld optical coherence tomography scanner for primary care diagnostics","volume":"58","author":"Jung","year":"2011","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"030502","DOI":"10.1117\/1.JBO.19.3.030502","article-title":"Stimulated penetrating keratoplasty using real-time virtual intraoperative surgical optical coherence tomography","volume":"19","author":"Lee","year":"2014","journal-title":"J. Biomed. Opt."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.jdermsci.2005.07.006","article-title":"Applications of optical coherence tomography in dermatology","volume":"40","author":"Gambichler","year":"2005","journal-title":"J. Dermatol. Sci."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"2950","DOI":"10.1364\/BOE.5.002950","article-title":"Automated assessment of the remineralization of artificial enamel lesions with polarization-sensitive optical coherence tomography","volume":"5","author":"Lee","year":"2014","journal-title":"Biomed. Opt. Express"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"8985","DOI":"10.1364\/OE.22.008985","article-title":"In vivo imaging of middle-ear and inner-ear microstructures of a mouse guided by SD-OCT combined with a surgical microscope","volume":"22","author":"Cho","year":"2014","journal-title":"Opt. Express"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"036009","DOI":"10.1117\/1.JBO.20.3.036009","article-title":"Evaluation of the usefulness of three-dimensional optical coherence tomography in a guinea pig model of endolymphatic hydrops induced by surgical obliteration of the endolymphatic duct","volume":"20","author":"Cho","year":"2015","journal-title":"J. Biomed. Opt."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"328","DOI":"10.3346\/jkms.2015.30.3.328","article-title":"Optical coherence tomography for the diagnosis and evaluation of human otitis media","volume":"30","author":"Cho","year":"2015","journal-title":"J. Korean Med. Sci."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Kut, C., Chaichana, K.L., Xi, J., Raza, S.M., Ye, X., McVeigh, E.R., Rodriguez, F.J., Qui\u00f1ones-Hinojosa, A., and Li, X. (2015). Detection of human brain cancer infiltration ex vivo and in vivo using quantitative optical coherence tomography. Sci. Transl. Med., 7.","DOI":"10.1126\/scitranslmed.3010611"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"9467","DOI":"10.3390\/s111009467","article-title":"Optical sensing method for screening disease in melon seeds by using optical coherence tomography","volume":"11","author":"Lee","year":"2011","journal-title":"Sensors"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1093734","DOI":"10.1155\/2016\/1093734","article-title":"In vivo monitoring on growth and spread of gray leaf spot disease in capsicum annuum leaf using spectral domain optical coherence tomography","volume":"2016","author":"Ravichandran","year":"2016","journal-title":"J. Spectrosc."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1007\/s13580-012-0071-x","article-title":"Application of optical coherence tomography to detect cucumber green mottle mosaic virus (CGMMV) infected cucumber seed","volume":"53","author":"Lee","year":"2012","journal-title":"Hortic. Environ. Biotechnol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1361","DOI":"10.1038\/nbt892","article-title":"Optical coherence tomography for ultrahigh resolution in vivo imaging","volume":"21","author":"Fujimoto","year":"2003","journal-title":"Nat. Biotechnol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"S1465","DOI":"10.3233\/BME-151445","article-title":"Lateral resolution enhancement using programmable phase modulator in optical coherence tomography","volume":"26","author":"Shirazi","year":"2015","journal-title":"Bio-Med. Mater. Eng."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"2354","DOI":"10.3938\/jkps.55.2354","article-title":"Optimization for axial resolution, depth range, and sensitivity of spectral domain optical coherence tomography at 1.3 microm","volume":"55","author":"Lee","year":"2009","journal-title":"J. Korean Phys. Soc."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1016\/j.optlaseng.2014.12.013","article-title":"Quantitative assessment of touch-screen panel by nondestructive inspection with three-dimensional real-time display optical coherence tomography","volume":"68","author":"Cho","year":"2015","journal-title":"Opt. Lasers Eng."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"6420","DOI":"10.1364\/OE.19.006420","article-title":"Multimodal analysis of pearls and pearl treatments by using optical coherence tomography and fluorescence spectroscopy","volume":"19","author":"Ju","year":"2011","journal-title":"Opt. Express"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"316","DOI":"10.3807\/JOSK.2010.14.4.316","article-title":"Counterfeit detection using characterization of safety feature on banknote with full-field optical coherence tomography","volume":"14","author":"Choi","year":"2010","journal-title":"J. Opt. Soc. Korea"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/j.displa.2011.04.002","article-title":"Nondestructive defect inspection for LCDs using optical coherence tomography","volume":"32","author":"Kim","year":"2011","journal-title":"Displays"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1007\/s00340-007-2743-2","article-title":"Beyond biomedicine: A review of alternative applications and developments for optical coherence tomography","volume":"88","author":"Stifter","year":"2007","journal-title":"Appl. Phys. B"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.optcom.2014.12.016","article-title":"Ultrawide-field parallel spectral domain optical coherence tomography for nondestructive inspection of glass","volume":"341","author":"Chen","year":"2015","journal-title":"Opt. Commun."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1364\/OL.22.000061","article-title":"Subsurface defect detection in ceramics by high-speed high-resolution optical coherent tomography","volume":"22","author":"Bashkansky","year":"1997","journal-title":"Opt. Lett."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1364\/OE.2.000540","article-title":"Subsurface defect detection in materials using optical coherence tomography","volume":"2","author":"Duncan","year":"1998","journal-title":"Opt. Express"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"10395","DOI":"10.3390\/s120810395","article-title":"Non-destructive inspection methods for leds using real-time displaying optical coherence tomography","volume":"12","author":"Cho","year":"2012","journal-title":"Sensors"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"106001","DOI":"10.1117\/1.JBO.17.10.106001","article-title":"Three-beam spectral-domain optical coherence tomography for retinal imaging","volume":"17","author":"Suehira","year":"2012","journal-title":"J. Biomed. Opt."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1158","DOI":"10.1364\/AO.50.001158","article-title":"Full-range k-domain linearization in spectral-domain optical coherence tomography","volume":"50","author":"Jeon","year":"2011","journal-title":"Appl. Opt."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"386","DOI":"10.3807\/JOSK.2011.15.4.386","article-title":"Simple spectral calibration method and its application using an index array for swept source optical coherence tomography","volume":"15","author":"Jung","year":"2011","journal-title":"J. Opt. Soc. Korea"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"14148","DOI":"10.1364\/OE.23.014148","article-title":"Demonstration of tolerance to dispersion of master\/slave interferometry","volume":"23","author":"Bradu","year":"2015","journal-title":"Opt. Express"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"6920","DOI":"10.3390\/s120606920","article-title":"Ultra-fast displaying spectral domain optical doppler tomography system using a graphics processing unit","volume":"12","author":"Jeong","year":"2012","journal-title":"Sensors"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/10\/1598\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T19:31:58Z","timestamp":1760211118000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/16\/10\/1598"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,9,28]]},"references-count":43,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2016,10]]}},"alternative-id":["s16101598"],"URL":"https:\/\/doi.org\/10.3390\/s16101598","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,9,28]]}}}